Whirlpool WED8300SB2 Owner's manual

Category
Electric laundry dryers
Type
Owner's manual

This manual is also suitable for

ELECTRONIC
ELECTRICDRYER
For questions about features, operation/pen%rmance, parts,
accessories or service, call: 1-800-253-1301
or visit our website at... www.wbidpooLcom
Table of Contents .................................................... 2
W10151580A
TABLEOFCONTENTS
DRYER SAFETY .............................................................................. 2
INSTALLATION INSTRUCTIONS .................................................. 3
Tools and Parts ............................................................................ 3
Optional Pedestal ......................................................................... 4
Location Requirements ............................................................... 4
Electrical Requirements ............................................................... 6
Electrical Connection ................................................................... 8
Venting Requirements ................................................................ 13
Plan Vent System ....................................................................... 14
Install Vent System ..................................................................... 15
Install Leveling Legs ................................................................... 15
Connect Vent .............................................................................. 15
Level Dryer ................................................................................. 15
Reverse Door Swing .................................................................. 16
Complete Installation ................................................................. 17
DRYER USE .................................................................................. 18
Starting Your Dryer..................................................................... 18
Stopping or Restarting Your Dryer ............................................ 19
Lock Controls ............................................................................. 19
Drying and Cycle Tips ................................................................ 19
Status Lights ............................................................................... 19
Cycles ......................................................................................... 20
Additional Features .................................................................... 21
Changing Cycles, Options and Modifiers .................................. 21
Drying Rack Option .................................................................... 21
DRYER CARE ................................................................................ 22
Cleaning the Dryer Location ....................................................... 22
Cleaning the Lint Screen ............................................................ 22
Cleaning the Dryer Interior ......................................................... 23
Removing Accumulated Lint ...................................................... 23
Vacation and Moving Care ......................................................... 23
TROUBLESHOOTING .................................................................. 24
ASSISTANCE OR SERVICE ......................................................... 26
ACCESSORIES ............................................................................. 26
WARRANTY .................................................................................. 28
DRYERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
Read all instructions before using the dryer.
Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry-
cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or
explode.
Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
Do not reach into the dryer if the drum is moving.
Do not install or store the dryer where it will be exposed
to the weather.
Do not tamper with controls.
Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair
instructions that you understand and have the skills to
carry out.
Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
Clean lint screen before or after each load.
Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
SAVE THESE INSTRUCTIONS
INSTALLATIONINSTRUCTIONS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Flat-blade screwdriver Vent clamps
#2 Phillips screwdriver Caulking gun and
compound (for installing
Adjustable wrench that new exhaust vent)
opens to 1" (2.5 cm) or
hex-head socket wrench Tin snips (new vent
(for adjusting dryer feet) installations)
Wire stripper (direct wire 1/4"nut driver or socket
installations) wrench (recommended)
Level Tape measure
Parts supplied
Remove parts packages from dryer drum. Check that all parts are
included.
Parts package.
1
4 Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a
pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
For close-clearance installations between 28.65" (72.77 cm)
and 34.15" (86.74 cm), see "Plan Vent System" section for
venting requirements.
I_-- s4.15"-_'1
(86.74 cm)
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the "Assistance
or Service" section.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated
120/240 volt minimum. The cord should be type SRD or
SRDT and be at least 4 ft (1.22 m) long. The wires that
connect to the dryer must end in ring terminals or spade
terminals with upturned ends.
A UL listed strain relief.
Areyouplacingthedryeronapedestal?Youhavetheoptionof
purchasingpedestalsofdifferentheightsseparatelyforthisdryer.
Youmayselecta10"(25.4cm)pedestalora15.5"(39.4cm)
pedestalwithashelfandbindividers.Thesepedestalswilladdto
thetotalheightofthedryerforatotalheightofapproximately46"
(116.8cm)or51.5"(130.8cm),respectively.
Foragarageinstallation,youwillneedtoplacethedryeratleast
18"(46cm)abovethefloor.
Optional pedestal (15.5" [39.4 cm] model shown)
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section.
Pedestal Color Part Number
Height
10" (25.4 cm) White WHP1000SQ
15.5" (39.4 cm) with White WHP1500SQ
shelf and bin dividers
Drying Rack
To order a drying rack, call the dealer from whom you purchased
your dryer or refer to the "Assistance or Service" section. Ask for
Part Number 8563738. For more information, see "Drying Rack
Option."
Stack Kit
Are you planning to stack your DUET SPORT TM washer and
dryer? To do so, you will need to purchase a Stack Kit.
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section. Ask for Part Number
8572546.
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If you are using a power cord, a grounded electrical outlet
located within 2 ft (61 cm) of either side of the dryer. See
"Electrical Requirements."
A sturdy floor to support the total dryer weight of 127 Ibs
(57.6 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If using a pedestal, you will
need 18" (46 cm) to the bottom of the dryer.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Installation clearances
Thelocation must be large enoughto allow the dryer door to
open fully.
Dryer Dimensions
36"
(91,4 cm)
!
!
27"
(68.6 cm)
501/2"
(128.27 cm)
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0" (0 cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
-- 2"*
i'"1"1'''°m'
36"rein
-,ilI I1 11II
1"* _ _'_27"--•-)_ _:-- 1"*
(2.5 crn) (68 6 crn) (2.5 crn)
*Required spacing
Closet installation - Dryer only
__'_ 48 in.2.
(310 c,i,,:
24 in.2 .
(155crn2)
11"*_28.6s"--_1s"**l
{2.5crn) (72.77crn)(12.7crn)
A
+
3"*
-- (7.6 crn)
+
A. Side view - closet or confined area
B. Closet door with vents
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
I olo
1,,-_tl_- 2T'--_ll_-- 1" 1".1I_-- 28.65"--)-Is"**l
(2.5 cm) (68.6 crn) {2.5 cm) {2.5 crn) {72.77 cm) (12.7 crn)
A B
A.Recessed area
B.Side view - closet or confined area
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for cabinet
installation
" T'* (17.8 cm)
cm) 5"** 28.65" 1"*
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
,I
1" 27" 1"
(12.7 crn) (72,77 crn) (2.5 cm) (2.5 cm)(68.6 crn) (2,8 crn)
* Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for recessed or
closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
46 in? *
{310 cm 2)
T
o
+
24 in. 2 *
(188crn2)
*Required spacing
5"* -_.
(12.7cm)
8"* (;.2 crn)
t
72"
(182.9 crn)
L
(2.8 cm) 88.6 cm
*Required spacing
Mobile home - additional installation requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
It is your responsibility
Tocontact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
Tosupply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here,
[] If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection" in the "Electrical Connection" section.
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor (white wire)
within the dryer. Ifthe dryer is installed with a 4-wire electrical
supply connection, the neutral ground wire must be removed
from the external ground conductor screw (green screw), and
secured under the neutral terminal (center or white wire) of
the terminal block. When the neutral ground wire is secured
under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
[] A UL listed 30-amp power supply cord, rated
120/240 volt minimum. The cord should be type SRD or
SRDT and be at least 4 ft (1.22 m) long. The wires that
connect to the dryer must end in ring terminals or spade
terminals with upturned ends.
[] A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper
wires and match a 4-wire receptacle of NEMA Type 14-30R. The
ground wire (ground conductor) may be either green or bare. The
neutral conductor must be identified by a white cover.
If your outlet looks like this:
3-wire receptacle (10-30t:?)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper
wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
[] Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum).
[] At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
3,
B_
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw
Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws enough to hold the two clamp sections together.
;f-_- ....................................A
{
L i,. .................D
-°iV
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief. The strain relief should have a tight fit with
the dryer cabinet and be in a horizontal position. Do not
further tighten strain relief screws at this point.
4.
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any
screws from a %" (1.9 cm) UL listed strain relief (UL
marking on strain relief). Put the threaded section of the
strain relief through the hole below the terminal block
opening. Reaching inside the terminal block opening,
screw the removable conduit connector onto the strain
relief threads.
A
B
.......... C
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be
in a horizontal position. Tighten strain relief screw against
the direct wire cable.
Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has: And you will be Go to Section
connecting to:
4-wire receptacle A UL listed, 120/ 4-wire connection:
(NEMA Type 14-30R) 240-volt Power supply cord
minimum,
30-amp, dryer
power supply
cord*
4-wire direct A fused 4-wire connection:
disconnect or Direct Wire
circuit breakerbox*
(12.7 cm)
3-wire receptacle A UL listed, 120/
(NEMA type 10-30R) 240-volt
(_ minimum,
30-amp, dryer
power supply
cord*
3-wire connection:
Power supply cord
3-wire direct A fused 3-wire connection:
disconnect or Direct Wire
circuit breaker
box*
*If local codes do not permit the connection of a cabinet-ground
conductor to the neutral wire, go to "Optional 3-wire
connection" section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
A
C D E G
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E.Spade terminals with upturned ends
F. 3A,,(1.9 cm) UL Iisted strain relief
G. Ring terminals
1. Remove center silver-colored terminal block screw.
2=
Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center,
silver-colored terminal block screw. Tighten screw.
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 11/2'' (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires into a hook shape.
3=
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw.
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4,,(1.9 cm) UL listed strain relief
Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1.
2.
Remove center silver-colored terminal block screw.
Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked
end (hook facing right) of the neutral wire (white or center
wire) of direct wire cable under the center screw of the
terminal block. Squeeze hooked ends together. Tighten
screw.
4.
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. ,_" (1.9 cm) UL listed strain relief
D. Center silver-colored terminal block screw
E.Neutral ground wire
E Neutral wire (white or center wire)
Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7.
You have completed your electrical connection. Now go to
"Venting Requirements."
E
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw.
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL listed strain relief
10
3.
Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
A
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable
C. 3/4"(1.9 cm) UL listed strain relief
D. Center silver-colored terminal block screw
E. Neutral ground wire
E Neutral wire (white or center wire)
4. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!I !!
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
"Venting Requirements."
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
A ......
C G F
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with up turned ends
E, _" (1.9 cm) UL Iisted strain relief
F. Ring terminals
G. Neutral (white or center wire)
1. Loosen or remove center silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the
terminal block. Tighten screw.
E
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL listed strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
"Venting Requirements."
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
11
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1=
2.
Loosen or remove center silver-colored terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten
screw.
3=
A.External ground conductor screw
B.Neutralground wire
C.Center silver-colored terminal block screw
D.Neutral wire (white or center wire)
EL_" (1.9cm) UL Iisted strain relief
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
"Venting Requirements."
Optional 3-wire connection
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.
3=
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
EL_" (!.9 cm) UL Iisted strain relief
E Grounding path determined by a qualified electrician
Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Connect a separate copper ground wire from the external
ground conductor screw to an adequate ground.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
12
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFF Mventing products are recommended.
4" (10.2cm) heavymetal exhaust vent
DURASAFF Mvent products can be purchased from your
dealer or by calling Whirlpool Parts and Accessories. For
more information, see the "Assistance or Service" section.
Rigid metal vent
For best drying performance, rigid metal vents are
recommended.
Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Clamps
Good Better
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
B
1_4,,--_" I
(10.2 cm)
A. Louvered hood style
B.Box hood style
The angled hood style (shown here) is acceptable.
4"
(10.2 cm)__
(6.4 cm)
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
13
Choose your exhaust installation type
A
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
E Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations
Fire Hazard
Cover unused exhaust holes with the following kit:
279818 (white)
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.
A B
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option
with pedestal installations)
C
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
T-%;#
ly
, _ X& _-
A B
A. Over-the-top installation (also available with one
offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. Please see the
"Assistance or Service" section to order.
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm)
mismatch
Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest number of elbows and
turns.
When using elbows or making turns, allow as much room as
possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
14
Determine vent length and elbows needed for best
drying performance
Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
Number of Type of Box or Angled
90° turns vent Iouvered hoods
or elbows hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
Flexible metal 31 ft (9.4 m) 23 ft (7 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
Flexible metal 27 ft (8.2 m) 19 ft (5.8 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
Flexible metal 25 ft (7.6 m) 17 ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Flexible metal 23 ft (7 m) 15 ft (4.6 m)
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Determine vent path" in "Plan Vent System." Avoid 90°
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer (not the console panel).
Gently lay the dryer on the cardboard. See illustration.
3.
4.
5.
Examine the leveling legs. Find the diamond marking.
Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Check that the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible
gas line.
4. Once the exhaust vent connection is made, remove the
corner posts and cardboard.
Check the levelness of the dryer. Check levelness first side to
side, then front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
15
You can change your door swing from a right-side opening to a
left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space
to protect the surface.
Remove the door assembly
1. Remove the 4 screws that hold the door hinge on the front
panel of the dryer.
®
2=
3.
A. Dryer front panel
B. Door assembly
Lay the door assembly on a flat, protected surface with the
inside (inner door assembly) facing up.
Remove the 6 Phillips head screws to release the outer door
assembly from the inner door assembly, as indicated below.
See illustration. It is important that you remove only the
6 indicated screws.
4. Lift the inner door assembly off the outer door assembly.
5. Disengage locking tabs by rotating inner ring clockwise. See
illustration.
Reverse hinge
1. Use a small flat-blade screwdriver to remove 2 plug strips
from the inner door. Slide the head of the screwdriver under
the plugs, being certain not to scratch the inner door surface.
Lift up.
2=
Remove hinge cover.
A ...................(__
3=
A. Door hinge
B. Plug strips
C. Hinge cover
Remove the 4 screws that attach to the inner door hinge and
move the hinge to the other side. Reinstall the 4 screws.
®
A. Door hinge
4. Reinstall plug strips on opposite side of the inner door.
5. Check for fingerprints on the glass. Clean glass if necessary.
6. Place the inner door assembly inside the outer door
assembly. To fit correctly, the inner door assembly edge fits
completely inside the outer door assembly edge.
A. Inner ring
B. Outer ring
6. Turn inner ring 180 ° and lock tabs into place.
16
7. Reassemble the inner and outer door assemblies with the
6 screws.
Reverse the strike
1. Use a small flat-blade screwdriver to remove plug strip from
the dryer door opening. Slide the head of the screwdriver
under the plugs, being certain not to scratch the dryer
surface. Lift up.
2. Remove the strike.
3. Insert strike and plug strip on the opposite side.
A
A.Plug strip (cannot be seenfrom this angle)
B. Door strike
Reinstall the door
1. Reattach door to dryer front panel with the 4 screws.
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check the dryer's final location. Be sure the vent is not
crushed or kinked.
5. Check that the dryer is level. See "Level Dryer."
6. For power supply cord installation, plug into an outlet. For
direct wire installation, reconnect power.
7. Remove the blue protective film on the console and any tape
remaining on the dryer.
8. Read "Dryer Use."
9. Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
10. Select a Timed Dry heated cycle, and start the dryer. Do not
select the Air Only modifier.
If the dryer will not start, check the following:
Controls are set in a running or "On" position.
Start button has been pushed firmly.
Dryer is plugged into an outlet and/or electrical supply
is connected.
Household fuse is intact and tight, or circuit breaker has
not tripped.
Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the
dryer door and feel for heat. If you feel heat, cancel cycle and
close the door.
If you do not feel heat, turn off the dryer and check the
following:
There may be 2 household fuses or circuit breakers for
the dryer. Check that both fuses are intact and tight, or
that both circuit breakers have not tripped. If there is still
no heat, contact a qualified technician.
NOTE: You may notice a burning odor when the dryer is first
heated. This odor is common when the heating element is first
used. The odor will go away.
@
\
A. Dryer front panel
B. Door assembly
2. Check for fingerprints on the glass. Clean the glass if
necessary.
3. Close door and check that it latches securely.
17
DRYERUSE
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not dry anything that has ever had anything
flammable on it (even after washing).
Failure to follow these instructions can result in death,
explosion, or fire.
Fire Hazard
No washer can completely remove oil.
Do not dry anything that has ever had any type of oil on
it (including cooking oils).
Items containing foam, rubber, or plastic must be dried
on a clothesline or by using an Air Cycle.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, electric shock, or injury to
persons, read the IMPORTANT SAFETY INSTRUCTIONS before
operating this appliance.
Follow these basic steps to start your dryer. Please refer to
specific sections of this manual for more detailed information.
f. Clean lint screen before each load. See "Cleaning the Lint
Screen."
2. Place laundry into dryer and shut door.
3. Press POWER.
4.
Point the dial to an Auto or Manual Cycle. The preset settings
for Auto or Manual Cycles will illuminate. The estimated (auto
cycle) or actual (manual) cycle time (in minutes) will show in
the display.
NOTE: A preset time is displayed when an automatic cycle is
selected. During the first few minutes of the drying process,
the cycle time may automatically vary from the preset time
based on the size and fabric type of the load. Toward the end
of the drying process, the estimated time display will adjust
again, showing the final drying time.
To use an Auto Cycle
Select DRYNESS to adjust how dry you want the load.
The time displayed is an estimated length of the cycle
based on the Dryness selected. As the cycle runs, the
control senses the dryness of the load and adjusts the
time automatically for the selected dryness level.
NOTE: Time is not adjustable for Automatic Cycles. Pressing
the Timing Up or Down buttons will cause a triple beep,
indicating that the time cannot be changed.
To make changes to the Dryness and/or Options during
an Auto Cycle:
Press PAUSE/CANCEL once.
Adjust Dryness and/or Options.
NOTE: Dryness level selections can be made only while
using Auto Cycles. Selecting More Dry, Normal or Less
Dry automatically adjusts the sensed time needed.
MOREDRY
NORMAL
Select an Auto Cycle. Auto cycles will default to the last
dryness setting used for that cycle.
DRYNESS
AutoCycles
18
5=
6.
7.
Auto Dry cycles take the guesswork out of drying time
and enhance fabric care. The amount of time that is
displayed is the estimated time remaining in the cycle.
To use a Manual Cycle
Point the dial to a Manual Cycle.
Press TIMING Up or Down until the desired drying time is
displayed. Tap TIMING Up or Down, and the time will
change by 1-minute intervals. Press and hold TIMING Up
or Down, and the time will change by 5-minute intervals.
NOTE: The Timing feature can be used only with Manual
Cycles.
rIMING
Press TEMP ADJUST until the desired temperature
illuminates.
To make changes to Time, Temperature, WRINKLE
SHIELD TM feature and Cycle Signal during a Manual
Cycle:
Press PAUSE/CANCEL once.
Adjust theTime, Temperature, WRINKLE SHIELD TM
feature and End of Cycle Signal.
(OPTIONAL STEP) If desired, select WRINKLE SHIELD TM
feature. For more details, see "WRINKLE SHIELD TM Feature"
in "Additional Features."
(OPTIONAL STEP) The Cycle Signal is preset to ON. If
desired, you may turn the Cycle Signal OFR
Press and hold START for approximately 1 second until dryer
starts. Be sure the door is closed.
If you do not press Start within 5 minutes of selecting a
cycle, the dryer automatically shuts off.
To pause/stop the dryer at any time
Open the door or press PAUSE/CANCEL once.
To restart the dryer
Close the door. Press and hold START until dryer starts.
To cancel your dryer at any time
Press PAUSE/CANCEL twice.
NOTE: Drying will continue from where the cycle was interrupted
if you close the door and press Start within 5 minutes. Ifthe cycle
is interrupted for more than 5 minutes, the dryer will shut off.
Select new cycle settings before restarting the dryer.
This feature allows you to lock your settings to avoid unintended
use of the dryer. You can also use the control lock feature to
avoid unintended cycle or option changes during dryer operation.
To enable the control lock feature:
Press and hold END OF CYCLE SIGNAL button for 3 seconds.
The Lock/Unlock Control icon lights up, and a single beep tone is
heard. To unlock, press and hold END OF CYCLE SIGNAL button
for 3 seconds. The indicator light turns off.
Select the correct cycle and dryness level or temperature for your
load. If an Auto Cycle is running, the display shows the estimated
cycle time when your dryer is automatically sensing the dryness
level of your load. If a Manual Cycle is running, the display shows
the exact number of minutes remaining in the cycle.
Cool Down tumbles the load without heat during the last few
minutes of all cycles. Cool Down makes the loads easier to
handle and reduces wrinkling. The length of the Cool Down
depends on the load size and dryness level.
Drying tips
Follow care label directions when they are available.
If desired, add a fabric softener sheet. Follow package
instructions.
Remove the load from the dryer as soon as tumbling stops to
reduce wrinkling. This is especially important for permanent
press, knits and synthetic fabrics.
Avoid drying heavy work clothes with lighter fabrics. This
could cause overdrying of lighter fabrics, leading to increased
shrinkage or wrinkling.
Cycle tips
Dry most loads using the preset cycle settings.
Refer to the Auto or Manual Preset Cycle Settings chart (in
the "Cycles" section) for a guide to drying various loads.
Drying temperature and Dryness are preset when you
choose an Auto Cycle. You can choose a different
dryness level, depending on your load by pressing the
DRYNESS button to select MORE DRY or LESS DRY.
If you wish to adjust the cycle length of a Manual Cycle,
you must press TIMING Up or Down. Adjust the
temperature of a Manual Cycle by pressing TEMP
ADJUST until the desired temperature is selected.
NOTE: You cannot choose a Dryness Level with Manual
Cycles.
You may follow the progress of your dryer with the drying Status
indicator lights.
SENSING/
WET_/
DAMP:/
COOLDOWN
CYCLECOMPLETE;i_
WRINKLESHIELD
Sensing
When a cycle is first turned on, the SENSING light illuminates
until a wet item is detected.
In an Auto Cycle, if a wet item has not been detected within
5 minutes, the Sensing light will turn off.
In a Manual Cycle, if a wet item is not detected within
5 minutes, the Sensing light will turn off and the Damp light
will turn on.
Wet
The WET light will turn on when a wet item has been detected in
the dryer. The Wet light will remain on until:
The damp dry point is reached in an Auto or Manual Cycle.
Damp
The DAMP light indicates that the load has reached the damp dry
level.
Cool Down
The COOL DOWN light illuminates during the cool down part of
the cycle. Laundry is cooling down for ease in handling.
Cycle Complete
This light illuminates when a drying cycle is finished. Ifthe
WRINKLE SHIELD TM feature has been selected, the WRINKLE
SHIELD TM feature indicator light will also be illuminated.
The Cycle Complete light turns off 1hour after the end of a drying
cycle (including the WRINKLE SHIELD TM cycle of 90 minutes),
when Pause/Cancel is pressed, or when the door is opened.
19
WRINKLE SHIELD TM Feature
The WRINKLE SHIELD TM feature light illuminates when this
option is selected. This indicator stays on with the Cycle
Complete light.
Indicator lights
Other indicator lights on the control panel show when Cycle,
Temp Adjust, and End of Cycle settings are selected.
Select the drying cycle that matches the type of load you are
drying. See Auto Preset or Manual Preset Cycle Settings charts.
c/_u
DELICATE
SUPER/ _ __TOUCH
DEUCAT /
DAMP_ \\ _\ _ QUICK
0R, \\ D,Y
_TIMED
\ _ ,DRY
AUTO MANUAL
Cycle control knob
Auto Cycles
Auto Cycles allow you to match the cycle to the load you are
drying. See the following Auto Preset Cycle Settings chart. Each
cycle dries certain fabrics at the recommended temperature. A
sensor detects the moisture in the load and automatically adjusts
the drying time for optimal drying.
Heavy Duty
Use this cycle to get High heat for heavyweight mixed loads,
cotton towels or jeans.
Normal
Use this cycle to get Medium heat for drying mixed loads and
sturdy fabrics such as work clothes.
Casual
Use this cycle to get Low heat for drying no-iron fabrics such as
sport shirts, casual business clothes and permanent press
blends.
Delicate
Use this cycle to get Low heat for drying synthetic fabrics,
washable knit fabrics and no-iron finishes.
Super Delicate
Use this cycle to get Extra Low heat to gently dry items such as
lingerie, exercise wear or sheer curtains.
Damp Dry
Use this cycle to dry items to a damp level using Low heat, or to
dry items that do not require an entire drying cycle. Damp dry
items such as jeans (to avoid stiffness) or cotton clothing (to
make ironing easier). The temperature setting on this cycle
cannot be adjusted. Items will have different levels of dampness.
At the end of this cycle, clothes will be damp.
Auto Preset Cycle Settings
Auto Cycles Temp. Time*
Load Type (Minutes)
HEAVY DUTY High 40
Heavyweight mixed loads,
cotton towels, jeans
NORMAL Medium 35
Mixed loads, corduroys, work
clothes, sheets
CASUAL Low 35
Permanent press, synthetics
DELICATE Low 30
Lightweight items, blouses,
synthetics
SUPER DELICATE Extra Low 25
Lingerie
DAMP DRY Low 20
Clothes to come out suitable
for ironing
*Estimated Time with Auto DRYNESS (Normal) setting.
Time will vary depending on load type and load size.
Manual Cycles
Use Manual Cycles to select a specific amount of drying time and
a drying temperature. When a Manual Cycle is selected, the
ESTIMATED TIME REMAINING display shows the actual time
remaining in your cycle. You can change the actual time in the
cycle by pressing TIMING Up or Down.
Timed Dry
Use this cycle to complete drying if items are still damp after an
Auto Cycle. Timed Dry is also useful for drying heavyweight and
bulky items such as bedspreads and work clothes.
Quick Dry
Use this cycle for drying small loads or loads that need a short
drying time.
Touch Up
Use this setting to help smooth out wrinkles from such items as
clothes packed in a suitcase or items wrinkled from being left in
the dryer too long.
Manual Preset Cycle Settings
Manual Cycles Temp. Default Time
Load Type (Minutes)
TIMED DRY High* 40
Heavyweight, bulky items,
bedspreads, work clothes
QUICK DRY Medium 27
Small loads
TOUCH UP Medium 20
Helps smooth out wrinkles
*The Timed Dry cycle will default to the last temperature used for
Timed Dry.
2O
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Whirlpool WED8300SB2 Owner's manual