Halsey Taylor 4430BF_FTN Owner's manual

Type
Owner's manual
PAGE 1
98646C (Rev. C - 12/12)
4430BF FOUNTAIN
4430BF Fountains are among the easiest to install Fountains on the market today.
To assure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference.
Owners Manual
Models 4430BF3, 4430BF2 & 4430BF1
Floor Mounted Tri-Level Bottle Filling Tubular Fountain
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
INSTALLER
MODEL
4430BF3
MODEL
4430BF2UM
MODEL
4430BF1L
PAGE 298646C (Rev. C - 12/12)
4430BF FOUNTAIN
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL ( 8" X 10" )
C = REMOVABLE BOTTOM COVER
8"
203mm
30"
762mm
37"
940mm
14 9/16"
371mm
3"
76mm
10"
254mm
O
27"
686mm
19"
483mm
57"
1448mm
64"
1626mm
3"
76mm
22 1/8"
562mm
19"
483mm
44"
1118mm
14 9/16"
371mm
3"
76mm
52 1/8"
1324mm
32 1/8"
816mm
14 9/16"
371mm
O
12"
305mm
B.C.
O
14"
356mm
O
1/2"
13mm
HOLES (6 PL)
48"
1219mm
A
7 15/16"
201mm
B
B
C
C
1-1/2"
DRAIN
4430BF3
FINISHED FLOOR
PAGE 3
98646C (Rev. C - 12/12)
4430BF FOUNTAIN
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL ( 8" X 10" )
C = REMOVABLE BOTTOM COVER
4430BF2ML
8"
203mm
30"
762mm
10"
254mm
O
37"
940mm
14 9/16"
371mm
3"
76mm
27"
686mm
19"
483mm
40 5/16"
1023mm
41 9/16"
1056mm
ORIFICE
HEIGHT
22 1/8"
562mm
19"
483mm
7 15/16"
201mm
3"
76mm
32 1/8"
816mm
14 9/16"
371mm
52 1/8"
1324mm
57"
1448mm
O
14"
356mm
O
12"
305mm
B.C.
O
1/2"
13mm
HOLES (6 PL)
48"
1219mm
1-1/2"
DRAIN
B
B
A
C
C
ACTUAL PRODUCT CONFIGURATION MAY VARY BASED ON MODEL ORDERED.
FINISHED FLOOR
PAGE 498646C (Rev. C - 12/12)
4430BF FOUNTAIN
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL ( 8" X 10" )
C = REMOVABLE BOTTOM COVER
4430BF1U
8"
203mm
30"
762mm
44"
1118mm
14 9/16"
371mm
3"
76mm
10"
254mm
O
64"
1626mm
27"
686mm
33 5/16"
846mm
22 1/8"
562mm
28 7/16"
723mm
7 15/16"
201mm
19"
483mm
19"
483mm
34 7/16"
875mm
ORIFICE
HEIGHT
29 3/4"
756mm
ORIFICE
HEIGHT
O
14"
356mm
O
12"
305mm
B.C.
O
1/2"
13mm
HOLES (6 PL)
48"
1219mm
1-1/2"
DRAIN
B
B
A
C
C
ACTUAL PRODUCT CONFIGURATION MAY VARY BASED ON MODEL ORDERED.
FINISHED FLOOR
PAGE 5
98646C (Rev. C - 12/12)
4430BF FOUNTAIN
1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be
capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply. (Valve not furnished)
4. Locate and install fountain using 3/8" minimum screws or bolts, (Screws or bolts not furnished).
5. Prior to installing the bottle filler to the center mounting position of fountain, insert drain pipe (Item #10) by positioning the short end of
drain pipe through mounting plate of bottle filler. Install bottle filler to fountain and secure with supplied hardware.
6. Prior to installing the bottle to the arm mount of fountain, insert the drain pipe (Item #11) into the arm tunnel and adjust drain to lean to
the left side of the arm when facing the button. Install bottle filler to arm being sure drain tube is above mounting plate of filler.
Secure filler to fountain with supplied hardware.
7. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler.
Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately
3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS DAMAGE TO THE O-RINGS MAY
RESULT.
8. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" IPS. Contractor to supply waste trap and service stop valve in
accordance with local code.
9. Connect water supply and fountain drain. Connect drain waste "Tee" to fountain drain tubes. Connect outlet of "Tee" to drainage
system. Water connection and drain must comply with local codes.
10. Turn on water supply and check all connections for leaks. Threaded drain fittings may require thread sealer to create a leak free
connection. Apply thread sealer to threaded connection fittings only, not the slip connection fittings.
CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water
supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures lower than
20 psig or higher than 105 psig is not covered by warranty.
11. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being con
nected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment
problems.
FIG. 1
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
FIG. 2
Actuation of Quick Connect Water Fittings:
Fountain is provided with lead-free connectors which utilize an
o-ring water seal. To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while pulling on the
tubing.(see Fig.2) To insert tubing, push tube straight into fitting
until it reaches a positive stop, approximately 3/4".
TROUBLE SHOOTING AND MAINTENANCE
STREAM HEIGHT ADJUSTMENT:
Stream height is factory set at 35 PSI. If supply
pressure varies greatly from this, insert a small straight
bladed screwdriver through the access hole in the
center of the push button and turn the adjustment
screw. Clockwise adjustment will raise the stream and
counterclockwise adjustment will lower the stream. For
best adjustment, the stream should be approximately
1 1/2" above the top of the bubbler . (See Fig. 3)
FIG. 3
PAGE 698646C (Rev. C - 12/12)
4430BF FOUNTAIN
24
1
23
12
24
20
13 or 16
18 & 25
12
14 & 24
23
5
15
19
22
4
22
15
15
23
20
6
13 or 16
12
1
15
10
1
4
15
21
3
6
24
23
24
17
13 or 16
26
23
23
24
9
2
21
15 & 24
19 & 23
4
24
20
11
9
5
15
15
PAGE 7
98646C (Rev. C - 12/12)
4430BF FOUNTAIN
PRINTED IN U.S.A.
ITEM NO. PART NO.
ITEMIZED PARTS LIST
DESCRIPTION
8
7
5
8
8
FIG. 4
15
24
12
See Fig. 4
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.260.6640
28467C
28955C
40551C
45464C
45832C
45833C
45734C
55996C
66346C
66815C
66816C
98118C
98530C
98532C
98677C
98678C
98679C
98680C
98681C
98682C
98683C
98684C
98685C
98686C
P05031
45931C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Basin
Cover - Round Plate
Tailpipe
Drain Plug 1-1/2"
Access Panel
Bottom Cover
Drain Tube
In - Line Strainer
Drain Tube
Tube - Drain
Tube - Drain (Arm Only)
Bubbler Assembly
Kit - Regulator W/Spring
Kit - "O" Rings and Fittings
Kit - Gasket
Kit - 1.0 GPM Regulator (BF Only)
Kit - Nozzle
Kit - Aerator
Kit - Bottle Filler Trim
Kit - Push Button
Kit - Plastic Drain
Kit - 90° Plastic Drain
Kit - 4400 Series Hardware
Kit - Bottle Filler Waterway
Aerator
Outdoor Bottle Filler Drain Plug
PAGE 898646C (Rev. C - 12/12)
4430BF FOUNTAIN
THIS PAGE WAS LEFT INTENTIONALLY BLANK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Halsey Taylor 4430BF_FTN Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI