Pump failures are often caused by debris in the cooling system. Before installing replacement pump, be certain
to thoroughly ush the entire cooling system. When replacing pump, also replace canister screen supplied with
this kit. Canister is located at the rear of machine.
CC-11 PUMP REPLACEMENT
FILTER SCREEN P/N 0558011905
KIT P/N 0558007485
Use only ESAB recommended coolant.
CAUTION
0558011902 09/2012
Replace screen inside canister. Rotate as shown.