STANDARD SPECIFICATIONS:
• Thermostatic wax element maintains the outlet
temperature to ±3.6ºF
• Must also order Multi-Choice
®
Universal rough
separately (R10000)
• Back-to-back installation capability
• Lever volume control handle; temperature adjustment dial
• Graphics indicate hot/cold temperature adjustment
• Field adjustable to limit rotation into hot water zone
• 2.5 gpm @ 80 psi for standard models and 1.75 gpm @ 80 psi
for models with -WE suffix
• Tub port maximum flow rate 8.6 gpm @ 60 psi
with R10000-UNBX
• All parts are replaceable from the front of the valve
• Adjusts for up to 1" wall thickness
• Available extension kit (RP75136) adds up to 1 3/8"
installation depth
• Shower arm overall horizontal length = 16" (406 mm),
including threaded ends
T17T053-
5 19/32"
(142 mm)
Face of plasterguard
should be flush with
finish wall line
Inlet
TUB AND SHOWER
FAUCET TRIM
Vero
®
Bath Collection
TempAssure
®
Thermostatic
Valve Only Trim (T17T053 Series)
Shower Only Trim (T17T253 & T17T253-WE Series)
Tub/Shower Trim (T17T453 & T17T453-WE Series)
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue
models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or
www.deltafaucet.com for finish options and product availability.
DSP-B-T17T053 Rev. J
2 3/4" (70mm)
Designate Proper Finish Suffix
8" (203 mm)
min.
18" (457 mm)
max.
As
Desired
2"
(51 mm)
Square
7 3/32"
(180 mm)
6 1/2"
(165 mm)
RP53419 (Pull-Up Diverter)
RP62955 (2.5 GPM)
RP91363 (1.75 GPM)
Touch-Clean
®
Raincan
= Adjustable H
2
Okinetic
Spray (AH
2
O)
= Soft Full Spray (SF)
= Shampoo Rinsing Spray (SR)
= Shampoo Rinsing
Spray
w/Massage (SRM)
=
Full Spray w/Massage (FSM)
= High-Efficiency Spray (HE)
= Crossing Full Spray (CF)
= Crossing Full Spray w/Massage (CFM)
= Fast Massage (FM)
= Soft Drench w/Full Spray (SDF)
= Soft Rain Spray (SRS)
= Soft Drench Spray (SD)
= Pause (P)
= Full Body Spray (FB)
= Adjustable Full Spray (AF)
SR
CF
CFM
HE
SDF
AF
SRM
SF
FB
SD
P
FSM
FM
= Massage Spray (M)
M
= Slow Massage (SM)
SM
= H
2
Okinetic
Spray (H
2
O)
= H
2
Okinetic
Spray w/Massage (H
2
OM)
H
2
O
H
2
OM
= Soft Drench Spray w/Massage (SDM)
SDM
AH
2
O
SRS
Full Spray
3"
(76 mm)
8 21/32"
(220 mm)
5 45/64"
(145 mm)
RP75136 Available Extension Kit
T17T453-
T17T453-WE
T17T253-
T17T253-WE
COMPLIES WITH:
ASME A112.18.1 / CSA B125.1
Indicates compliance to
ICC/ANSI A117.1 - Valve control only
• EPA
WaterSense
®
(WE models only)
Delta Faucet Company
55 E. 111th Street, Indianapolis, IN 46280
350 South Edgeware Road, St. Thomas, ON N5P 4L1
© 2018 Delta Faucet Company
SHOWER HEAD(S)
POMME(S) DE DOUCHE
CABEZA(S) DE REGADERA
SHOWER HEAD(S)
POMME(S) DE DOUCHE
CABEZA(S) DE REGADERA
SHOWER HEAD(S)
POMME(S) DE DOUCHE
CABEZA(S) DE REGADERA
WARRANTY
Parts and Finish - Lifetime limited warranty; or for
commercial purchasers, 10 years for multi-family
residential (apartments and condominiums) and
5 years for all other commercial uses, in each case
from the date of purchase.
Electronic Parts and Batteries (if applicable) - 5
years from the date of purchase; or for commercial
purchasers, 1 year from the date of purchase. No
warranty is provided on batteries.
FEATURES:
TempAssure
®
17T thermostatic valve cartridge
  • Page 1 1

Delta Faucet T17T453-CZ-WE Specification

Type
Specification

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI