IBA ibaPDA-Interface-Oracle Owner's manual

Category
Database software
Type
Owner's manual
ibaPDA-Interface-Oracle
Write/read access to databases
Manual
Issue 1.3
Measurement Systems for Industry and Energy
www.iba-ag.com
2
Manufacturer
iba AG
Koenigswarterstr. 44
90762 Fuerth
Germany
Contacts
Main oce +49 911 97282-0
Fax +49 911 97282-33
Support +49 911 97282-14
Engineering +49 911 97282-13
Web www.iba-ag.com
Unless explicitly stated to the contrary, it is not permied to pass on or copy this document, nor
to make use of its contents or disclose its contents. Infringements are liable for compensaon.
© iba AG 2021, All rights reserved.
The content of this publicaon has been checked for compliance with the described hardware
and soware. Nevertheless, discrepancies cannot be ruled out, and we do not provide guaran-
tee for complete conformity. However, the informaon furnished in this publicaon is updated
regularly. Required correcons are contained in the following regulaons or can be downloaded
on the Internet.
The current version is available for download on our web site www.iba-ag.com.
Version Date Revision - Chapter / Page Author Version SW
1.3 09-2023 Installaon of client not necessary, GUI new rm 8.0.0
Windows® and SQL Server® are brands and registered trademarks of Microso Corporaon. Or-
acle® and MySQL are registered trademarks of Oracle and/or its partners.
Other product and company names menoned in this manual can be labels or registered trade-
marks of the corresponding owners.
3
1.3 3
ibaPDA-Interface-Oracle Contents
Contents
1 About this Manual ............................................................................................................4
1.1 Target group and previous knowledge ..................................................................... 4
1.2 Notaons .................................................................................................................. 4
1.3 Used symbols ............................................................................................. ...............5
2 System requirements ........................................................................................................6
3 SQL database interface ......................................................................................................7
3.1 General informaon ................................................................................................. 7
3.2 Comparison to the DB/cloud data storage ............................................................... 8
3.3 System Topologies .................................................................................................... 8
3.4 Basic procedure ........................................................................................................ 9
4 ConguraonandengineeringibaPDA ............................................................................ 10
4.1 Interface sengs .................................................................................................... 10
4.2 Create a database connecon ................................................................................ 12
4.2.1 Oracle DB connecon .............................................................................................13
4.2.1.1 Basic conguraon .............................................................................................. 14
4.2.1.2 TNS conguraon ................................................................................................ 14
4.3 SQL modules ........................................................................................................... 16
4.3.1 Add SQL module ..................................................................................................... 16
4.3.2 General module sengs ......................................................................................... 17
4.3.3 Buer ...................................................................................................................... 19
4.4 SQL statements ............................................................................................ ........... 22
4.4.1 Test SQL statements................................................................................................ 23
4.4.2 Link SQL queries with input signals ........................................................................ 24
4.4.3 Use parameters ...................................................................................................... 26
5 Diagnoscs ......................................................................................................................28
5.1 License .................................................................................................................... 28
5.2 Visibility of the interface .. ....................................................................................... 28
5.3 Log les ............................................................................................ .......................29
5.4 Connecon diagnoscs with PING .......................................................................... 30
5.5 Diagnosc modules ................................................................................................31
6 Support and contact ........................................................................................................ 36
4 1.3
About this manual ibaPDA-Interface-Oracle
1 About this manual
This document describes the funcon and applicaon of the soware interface
ibaPDA-Interface-Oracle.
This documentaon is a supplement to the ibaPDA manual. Informaon about all the other
characteriscs and funcons of ibaPDA can be found in the ibaPDA manual or in the online help.
1.1 Targetgroupandpreviousknowledge
This documentaon addresses qualied professionals, who are familiar with handling electrical
and electronic modules as well as communicaon and measurement technology. A person is
regarded as a professional if he/she is capable of assessing the work assigned to him/her and
recognizing possible risks on the basis of his/her specialist training, knowledge and experience
and knowledge of the standard regulaons.
This documentaon in parcular addresses persons, who are concerned with the conguraon,
test, commissioning or maintenance of supported databases, cloud or cluster storage technolo-
gy. For the handling of ibaPDA-Interface-Oracle the following basic knowledge is required and/
or useful:
■ Basic knowledge of ibaPDA
■ Basic knowledge of databases, cloud or cluster storage technology
■ Applicaon of SQL statements
1.2 Notaons
In this manual, the following notaons are used:
Acon Notaon
Menu command Menu Logic diagram
Calling the menu command Step 1 – Step 2 – Step 3 – Step x
Example:
Select the menu Logic diagram – Add – New funcon
block.
Keys <Key name>
Example: <Alt>; <F1>
Press the keys simultaneously <Key name> + <Key name>
Example: <Alt> + <Ctrl>
Buons <Key name>
Example: <OK>; <Cancel>
Filenames, paths Filename, Path
Example: Test.docx
5
1.3 5
ibaPDA-Interface-Oracle About this manual
1.3 Used symbols
If safety instrucons or other notes are used in this manual, they mean:
Danger!
Thenon-observanceofthissafetyinformaonmayresultinanimminentrisk
ofdeathorsevereinjury:
■ Observe the specied measures.
Warning!
Thenon-observanceofthissafetyinformaonmayresultinapotenalriskof
deathorsevereinjury!
■ Observe the specied measures.
Cauon!
Thenon-observanceofthissafetyinformaonmayresultinapotenalriskof
injuryormaterialdamage!
■ Observe the specied measures
Note
A note species special requirements or acons to be observed.
Tip
Tip or example as a helpful note or insider p to make the work a lile bit easier.
Otherdocumentaon
Reference to addional documentaon or further reading.
6 1.3
System requirements ibaPDA-Interface-Oracle
2 System requirements
The following system requirements are required to use the SQL interface to a database of the
Oracle type:
■ ibaPDA v8.0.0 or higher
■ License for ibaPDA-Interface-Oracle
For further requirements for the used computer hardware and the supported operang sys-
tems, refer to the ibaPDA documentaon.
Licenseinformaon
Order no. Product name Descripon
31.001113 ibaPDA-Interface-Oracle Extension license for an ibaPDA system for
reading from and wring to databases of the
Oracle type. License for 8 SQL modules ac-
cording to 8 SQL statements.
31.101113 one-step-up-Interface-Oracle Extension license for addional 8 SQL mod-
ules. Max. 3 permissible (32 SQL modules
total)
7
1.3 7
ibaPDA-Interface-Oracle System requirements
3 SQL database interface
3.1 Generalinformaon
The SQL interface of ibaPDA forms the basis for a series of database interfaces via which ibaPDA
can read data both from databases as well as write data in databases.
sing the SQL interface you congure and manage the connecons to one or more databases.
You can congure one or more connecons per database. All DB connecons can be used simul-
taneously. The databases can be of the same or dierent types.
Database systems of dierent vendors are supported:
■ Maria DB
■ MySQL
■ Oracle
■ PostgreSQL
■ SAP HANA1)
■ SQL Server
The data exchange with the databases occurs via corresponding SQL modules, which are cong-
ured according to the specic database type.
The data is accessed with SQL statements.
■ Input direcon (read)
For the reading access, custom SQL queries (e.g. SELECT) are used and their results are
mapped to input signals in ibaPDA.
In the queries, you an oponally use parameters, which are assigned to the signals, in order
to change the queries dynamically during the ongoing acquision
■ Output direcon (write)
SQL commands (e.g. UPDATE, INSERT) are used for wring access in order to write data
from ibaPDA into the database.
In the statements, you can oponally use parameters, which are assigned to the signals, in
order to write signal actual values.
You can execute queries and commands cyclically or triggered.
1) DB client installaon ".NET data provider" required on ibaPDA server
8
8 1.3
SQL database interface ibaPDA-Interface-Oracle
3.2 ComparisontotheDB/clouddatastorage
In addion to quick measured values that are acquired via other interfaces, the SQL interface
serves mainly to acquire addional data about a process, a plant or a product or to output
current values, operang statuses or calculated values to a database. The access may occur by
request or cyclically, whereby you must always take the response me of the database into con-
sideraon.
The corresponding data storage (e.g. ibaPDA-Data-Store-SQL-Server, ibaPDA-Data-Sto-
re-SQL-Oracle etc.) is to be used for faster connuous data wring in databases or cloud sys-
tems.
SQL interfaces and DB data storage support the same database types so that you can choose.
SQL interface DB/cloud data storage
■ Conguraon in the I/O manager
(read/write)
■ Conguraon as data storage
(write only)
■ Access to any exisng custom table/view is
possible
■ The user must provide tables, e.g. by SQL
statements
■ Fix table structure, specied by the data
storage prole
■ Table is automacally generated by
ibaPDA.
■ Cyclical/triggered reading with custom SQL
queries
■ Cyclical/triggered inserng or updang
with custom SQL commands
■ Connuous/triggered wring of signal
trends as me series data
■ Reading the signal trends from the data-
base with SQL trend queries in ibaAnalyzer
■ Reading the signal trends from the data-
base with ibaDaVIS
Table 1: Dierences between SQL interface and DB/cloud data storage
3.3 SystemTopologies
The connecons between databases and ibaPDA can be established via standard Ethernet inter-
faces of the computer.
Note
If highly cyclical accesses or very large data volumes are expected, it is recom-
mended to implement TCP/IP communicaon on a separate network segment in
order to rule out a mutual interference by other network components, such as
PLC systems.
1.3 9
ibaPDA-Interface-Oracle SQL database interface
3.4 Basicprocedure
1. Check whether addional soware and/or licenses of the database manufacturer are re-
quired for the planned database connecon.
2. If necessary, install the required soware on the ibaPDA computer, e.g. the soware "ADO.
NET Data Provider" for SAP HANA connecons.
3. In ibaPDA, open the I/O Manager, Inputs tab, and congure one or more database connec-
ons on the SQL interface.
See ì Create a database connecon, page 12
For database queries (read access)
1. Under the SQL interface on the Inputs tab, add a module SQL query and select one of the
previously congured database connecons for the module.
2. Formulate an SQL statement for the database query with or without parameters.
3. If you use parameters: Assign the corresponding analog and/or digital signals to the parame-
ters whose values you want to use for the query.
4. Congure the analog and/or digital input signals.
Fordatabasecommands(writeaccess)
1. Under the SQL interface on the Outputs tab, add a module SQL command and select one of
the previously congured database connecons for the module.
2. Formulate an SQL statement as an SQL command with or without parameters.
3. If you use parameters: Assign the corresponding analog and/or digital signals to the parame-
ters whose values you want to write in the database.
Cauon
ThenetworkandDBcanbeoverloadedbyhighlycyclicalDBaccessesand/
orverylargedatavolumes.IntheSQLstatements,anySQLcommandscanbe
usedandthereforecausedamage(e.g."deletetable","dropdatabase",etc.).
Therefore...
■ Only have qualied users create/change SQL statements (→ user manage-
ment, security administraon).
■ Involve your DB administrator for quesons about conguring the SQL state-
ments. For example, the DB user used in ibaPDA for the DB connecon should
only have the rights that are actually required.
■ Set an appropriate update me (as short as necessary, as long as possible).
■ Assess and test the results of your SQL statement.
10 1.3
SQL database interface ibaPDA-Interface-Oracle
4 ConguraonandengineeringibaPDA
The engineering for ibaPDA is described in the following. If all system requirements are fullled,
ibaPDA displays the SQL database interface in the interface tree of the I/O Manager.
Note
The SQL interface is visible as soon as one of the SQL interface licenses (SQL
Server, Oracle, PostgreSQL, MySQL, SAP HANA) is available on the license con-
tainer (dongle or so license). Even if only one database type is licensed, all sup-
ported DB types appear in the SQL interface conguraon. Nevertheless, you can
only use the licensed type for data acquision.
4.1 Interfacesengs
The interface has the following funcons and conguraon opons.
Setallvaluestozerowhentheconnecontoadatabaseislost
If this opon is enabled, all signal values in the modules are set to zero as soon as the connec-
on is lost. ibaPDA regularly aempts to restore the database connecon unl it either suc-
ceeds or the acquision stops.
If this opon is disabled, ibaPDA keeps the last values in memory when the connecon is lost.
Note
It may take some me unl the signal values are set to zero. A longer response
me of a database, even in the range of several seconds, is not necessarily an
indicaon of an interrupted connecon.
Startacquisionevenifadatabaseisnotaccessible
If this opon is enabled, the acquision starts even if one or more of the congured databases
are not accessible. A warning is prompted in the validaon dialog, not an error. If the system
11
1.3 11
ibaPDA-Interface-Oracle Conguraon and engineering ibaPDA
was started without a connecon to a database, ibaPDA periodically tries to connect to the da-
tabase.
DBconnecons
This area displays the congured database connecons. Each database connecon is clearly
idened with an ID number, the database type and the connected database. You can use the
buons to create, edit and delete database connecons. The coming chapters describe the con-
guraon of the database connecons.
<Openlogle>
If connecons to controllers have been established, all connecon specic acons are recorded
in a text le. Using this buon, you can open and check this le. In the le system on the hard
disk, you nd the log les of the ibaPDA server (…\ProgramData\iba\ibaPDA\Log).
The le name of the current log le is InterfaceLog.txt; the name of the archived log
les is InterfaceLog_yyyy_mm_dd_hh_mm_ss.txt.
<Resetstascs>
Click this buon to reset the calculated mes and error counters in the table to 0.
Tablewithconneconstascs
The boom area of the dialog contains a table for the purpose of connecon diagnoscs. Stas-
cal informaon, such as counter values and mes, are displayed for each congured SQL mod-
ule.
Note
Due to the nature of relaonal databases, error counters may increment more
slowly than success counters. Note this when diagnosing connecon problems.
Column Meaning
Module Name of the SQL module (query and command modules)
Statements Processed: Number of executed SQL statements
Error: Number of SQL statements where failures occurred. Either SQL state-
ments failed (database responds with error) or statements could not be
executed, because the database was not accessible and the buer was full.
An empty result for a statement is not considered an error.
Rows Max: The highest number of rows that was returned since the last start of
acquision or the last reset of the counter aer a statement.
Last: The number of rows that was returned aer the last statement.
Response me Time values for the duraon between the execuon of the SQL statement
and the conrmaon of the execuon by the database.
Min, Max, Avg: These values relate to the executed statements since the
start of the acquision or the last stascs reset.
Last: Response me of the last executed statement.
Table 2: Columns of the connecon diagnoscs
12 1.3
Conguraon and engineering ibaPDA ibaPDA-Interface-Oracle
4.2 Createadatabaseconnecon
Before you can exchange data with a database, you must rst congure a connecon.
1. Select the interface SQL Database in the interface tree and click on the buon <Create
new>.
2. Select the desired database type.
The lower part of the dialog changes depending on which type you select.
3. In the lower part of the dialog, enter the informaon about the database or select it (e.g. DB
server, database name, authencaon method, possibly user name and password).
You can nd more details in the next chapter.
By specifying this informaon, a name is automacally generated for this connecon and dis-
played in the eld Connecon name (user name@database). You can overwrite the name.
In the case of mulple connecons to the same type, you can disnguish the connecon using
this name. In addion, you select the DB connecon later using this name during the module
conguraon.
The connecon name is displayed in the table with the DB connecons in the DB name column.
You can edit DB connecons at any me once they have been created by selecng the respec-
ve connecon in the table and clicking on the <Edit> buon.
Use the <Remove> buon to delete the selected DB connecon.
Note
If a database connecon is to be deleted that is already assigned to one or more
modules, a warning appears.
Since SQL modules are linked to a DB connecon in the SQL interface, you must
make sure that the modules do not lose their reference to the connecon. Oth-
erwise the SQL statements will have no eect.
1.3 13
ibaPDA-Interface-Oracle Conguraon and engineering ibaPDA
4.2.1 OracleDBconnecon
Databasetype
In the drop-down menu, select your database type. Here it is Oracle.
Timeout
Here you can specify a value for the meout in seconds for establishing the connecon. If the
me set here is exceeded, ibaPDA aborts the connecon aempt and displays an error mes-
sage.
Note that once the connecon is made, each command sent to the database has an addional
meout, which can be set by the applicaon that makes use of it. There is no generic congura-
on for the command meout.
Conneconname
This line contains the name of the database connecon. The name is automacally formed and
entered according to the scheme username@database as soon as you have lled in the elds
below. You can also overwrite the connecon name.
You can use this name to idenfy the database connecon in the overview table at the interface
level. The connecon name is there in the DB name column.
Oracledatabaseconnecon
You have 2 possibilies to congure a connecon to the Oracle database. The establishment of
a connecon to an Oracle server or cluster makes the dierence.
■ Basic conguraon, details see chapter ì Basic conguraon, page 14
■ TNS conguraon, details see chapter ì TNS conguraon, page 14
In both cases you’ll have to authencate yourself:
Username/Password
Enter here the required login data for the database. If necessary, inquire the correct data from
your DB administrator.
These elds are only available if the opon OS-Authencaon is disabled.
14 1.3
Conguraon and engineering ibaPDA ibaPDA-Interface-Oracle
UseOSauthencaon
If you enable this opon, the user account with which the ibaPDA server is running on is used.
This is normally the system account. Please check with your DB administrator whether this
method is appropriate or not.
<Testconnecon>
ibaPDA checks the access to the selected database on the set DB server. If the connecon is suc-
cessful, the message includes the version of the database.
4.2.1.1 Basicconguraon
When using basic conguraon, ibaPDA can connect to one Oracle server. A failover cluster can
not be congured with these sengs.
The following sengs are necessary:
Serveraddress
IP address or DNS name of the Oracle server.
Port
TCP port through which the Oracle server communicates.
Servicename/SID
Name of the Oracle service, as congured in the Oracle server.
UseSIDinsteadofServicename
In some rare cases SID might need to be used. Please refer to the Oracle documentaon for the
dierence between SID and service name.
4.2.1.2 TNSconguraon
Conguraon with TNS allows the use of a failover cluster instead of a single server congura-
on for the Oracle database.
TNS name or content
For TNS conguraon, use one of the following possibilies:
1.3 15
ibaPDA-Interface-Oracle Conguraon and engineering ibaPDA
1.Enterthenameofaconneconthatisavailableinthe"tnsnames.ora"leintheOraclecli-
ent directory.
Note that the client directory is the directory where the Oracle client dll that is congured in
machine.cong is located. ODP.NET searches for the le tnsnames.ora in the following
order:
■ First in the Oracle client directory. That is a parent directory of the directory where the
Oracle.ManagedDataAccess.dll is located. Mulple clients can be installed, but
only one ODP.NET installaon can be congured machine wide, in machine.cong.
■ Then in the current directory, the directory form where the applicaon is started. For exam-
ple in the ibaPDA server directory
(C:\Program Files (x86)\iba\ibaPDA\Server).
2.Enteracompleteseconlikeitcanbefoundina"tnsnames.ora"le.
Example:
(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)
(HOST=192.168.99.101)(PORT=1521)))(CONNECT_DATA=(SERVER=
DEDICATED)(SERVICE_NAME=xe)))
Enter the complete secon in one line. This entry has the advantage that ibaPDA can run while
an upgrade of the Oracle server is being performed. ODP.NET reads tnsnames.ora only
once. If the content of the le changes, you only need to add the changed part of the le to the
Oracle conguraon in the ibaPDA client and apply the new conguraon.
Pathtotnsnames.ora
If an Oracle client is already installed on the computer, the appropriate tnsnames.ora le
can be searched for. Addionally, you can specify the path to the le or select it via the browser
buon. A manually selected path to tnsnames.ora can be set as default via the gear buon.
If the le does not exist, a suitable le must be created or provided by the Oracle Admin. Save
the le on your computer and specify the path to it.
If you specify the complete contents of the tnsnames.ora le in the rst line (TNS name
or content), then the Path eld can remain empty. If you specify only the TNS name, you must
specify the path to the complete le.
Automacsearch
The search is rst done in the registry key TNS_ADMIN. There you can enter the reference to
tnsnames.ora as admin.
If the le is found there, then the search is done in the default directory for an Oracle client. If
the le is also found there, then the ibaPDA server directory is searched.
If tnsnames.ora is found, then the path is also shown in the Path eld.
If you overwrite the path manually, then the entered path is valid.
If no tnsnames.ora le is found via the automac search, then an error message appears
with a dialog, in which you can select the le.
16 1.3
Conguraon and engineering ibaPDA ibaPDA-Interface-Oracle
4.3 SQL modules
For the SQL modules under the SQL interface, there are input modules and output modules.
An SQL module is either a reading module with an SQL query or a wring module with an SQL
command. That is why the terms SQL query module and SQL command module are used in the
following text as well.
A module cannot be both simultaneously. That is why there is also no SQL module that can be
seen simultaneously in the I/O Manager on both tabs Inputs and Outputs.
However, the modules are very similar in their structure and components.
The following applies to all SQL modules:
■ The SQL modules have a reference to a database connecon in the SQL interface.
■ The SQL modules contain an SQL statement (query or command).
■ The SQL modules oer an assignment table for parameters used in the SQL statements.
■ The SQL modules can work cyclically or triggered.
4.3.1 Add SQL module
1. Click on the blue command Click to add module… located under each data interface in the
Inputs or Outputs tab.
2. Select the desired module type in the dialog box and assign a name via the input eld if re-
quired.
3. Conrm the selecon with <OK>.
Table 3: Add an SQL query module (le) or SQL command module (right)
1.3 17
ibaPDA-Interface-Oracle Conguraon and engineering ibaPDA
4.3.2 Generalmodulesengs
Table 4: General module sengs for input modules (le) and output modules (right)
Basicsengs
ModuleType(informaononly)
Indicates the type of the current module.
Locked
You can lock a module to avoid unintenonal or unauthorized changing of the module sengs.
Enabled
Enable the module to record signals.
Name
You can enter a name for the module here.
Module No.
This internal reference number of the module determines the order of the modules in the signal
tree of ibaPDA client and ibaAnalyzer.
Timebase
All signals of the module are sampled on this mebase.
Usenameasprex
This opon puts the module name in front of the signal names.
Module structure (only input modules)
No.ofanalogsignals/digitalsignals
Dene the number of congurable analog and digital signals in the signal tables. The default
value is 32 for each. The maximum value is 1000. The signal tables are adjusted accordingly.
Trigger
Updateme
You can use the update me in milliseconds to determine the following:
18 1.3
Conguraon and engineering ibaPDA ibaPDA-Interface-Oracle
■ In Cyclic send mode: execuon interval of the SQL statements
■ In the On change and On trigger mode: dead me aer execung a statement
Send mode
Set here when to execute the SQL statements (queries and commands).
■ Cyclic: The SQL statement is executed cyclically at the set update me.
■ On change: When selecng this mode, the line Trigger signal appears. Aer a triggering, all
other triggering value changes are ignored unl the update me has expired. Only then can
the SQL statement be executed again.
■ On trigger: When selecng this mode, the line Trigger signal appears. Aer a triggering, all
other triggering triggers are ignored unl the update me has expired. Only then can the SQL
statement be executed again.
Triggersignal(forOnchangeorOntriggersendmode)
In the On change send mode: You can select any analog or digital signal here to serve as the
trigger. In case of a change to the signal value, the SQL statement is executed.
In the On trigger send mode: You can select any digital signal here to serve as the trigger. In case
of a rising edge of the signal, the SQL statement is executed.
Queuesize
The queue serves as a buer for SQL statements in the following cases:
■ The database connecon is interrupted.
■ The execuon of an SQL statement takes long while new SQL statements are already trig-
gered in ibaPDA before the execuon has been nished.
Use the queue size to determine how many SQL statements are intermediately stored as a maxi-
mum. If this number is exceeded, the oldest SQL statements are deleted.
■ With input modules, the queue is 1 by default:
Since the results of an SQL query are mapped to signals, in most cases it is not useful to catch
up on queries that were not executed due to an interrupted connecon. The SQL queries
buered in the queue would then be executed in quick succession and the results transmit-
ted to the signals. With the queue size 1, only the last triggered SQL query is always kept
available.
■ With output modules, the queue size is 1000 by default:
Producon data, for example, can be wrien via SQL commands. It is important here that
these are also buered and made up for in case of a connecon breakdown.
1.3 19
ibaPDA-Interface-Oracle Conguraon and engineering ibaPDA
Commandmeout
By seng the command meout, you determine the maximum me for a statement to be exe-
cuted. If the query or command is not completed before the command meout has elapsed, the
execuon is aborted. The default sengs of query and command dier:
■ SQL query: 5 s
■ SQL command: 30 s
4.3.3 Buer
In output direcon the interface uses a memory buer and addionally a le buer that can be
enabled oponally.
Data to be sent to the target system always passes through the internal ibaPDA memory buer.
If the connecon to the target system exists, the data is sent there immediately. If the connec-
on is lost, or the data cannot be sent out fast enough, the data is temporarily stored in the
memory buer. The memory buer is located in the RAM of the ibaPDA computer and is there-
fore limited and volale. If, for example, the acquision is restarted, the buered data will be
lost. If the memory buer grows beyond the congured size during ongoing acquision, the old-
est values are deleted and thus lost.
To improve this, a le buer can addionally be enabled, which can buer much larger amounts
of data. The data is stored in les in a directory on a local drive of the ibaPDA computer. When
the le buer is enabled, data is transferred from the overowing memory buer to the le buf-
fer. If the acquision is stopped or restarted (e.g. by applying a modied I/O conguraon), data
that may be in the memory buer at this me is also transferred to the le buer.
Aer reconnecng to the target system, the oldest data is always sent rst. Newer values are
added to the buer in the meanme. If there is sll buered data in the le buer when the
acquision is started, it will be handled and processed in the same way.
In terms of SQL statements this means that the statements are buered according to the con-
guraon which was valid at the me of buering. If you change the SQL statement during an
ongoing buering (change and apply in the I/O Manager), the system will sll execute the old
statements as generated at the me of buering aer the connecon has been reestablished.
You congure the buering on the Buer tab in the Outputs secon of the SQL interface.
20 1.3
Conguraon and engineering ibaPDA ibaPDA-Interface-Oracle
Memorybuer
The memory buer is always enabled. You cannot deacvate it because data to be transmied
always passes through the buer before being forwarded to the target system.
Maximumsize
Enter here the maximum total size for items buered in memory. If the maximum size is exceed-
ed, there are 2 opons:
■ When le buering is disabled, the oldest item in memory is deleted (and is lost forever).
■ When le buering is enabled, the oldest part of the buer memory is moved to a buer le.
Periodicallypersistmemorybuerevery…s
You can only enable this opon if le buering is enabled. If the opon is enabled, the enre
memory buer is periodically swapped to a buer le.
Enter a duraon aer which the memory buer is periodically stored. It must be between 10 s
and 600 s.
With this opon you can ensure that as lile data as possible is lost in case of a system failure.
Currentmemoryconguraon
Display of the approximate me period that can be temporarily stored in the memory buer
with the congured sengs. Specicaon in d.hh:mm:ss.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

IBA ibaPDA-Interface-Oracle Owner's manual

Category
Database software
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI