Danfoss GBC Ball Valve - 45 bar for CO2 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Danfoss GBC Ball Valve - 45 bar for CO2 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DKRCC.PI.FB0.C2.02 / 520H8640 © Danfoss A/S (AC-MCI / sw), 2014-08
Installation guide
Shut-o ball valve for R744 (45 bar/650 psi)
Type GBC 6s to GBC 42s
009R9507
009R9507
Danfoss
9G218.10
Temperature range: -40 – 150 °C / -40 – 300 °F
Max. working pressure (PS/MWP):
45 bar/650 psi
Remove cap and access cap (if present)
OPEN position
CLOSED position
Danfoss
9G162.13
Danfoss
9G144.12
Danfoss
9G145.12
Refrigerant: R744 (CO
2
)
Opening valve
Single-ow
1
2
Valve size
Max. Torque
Nm ft-lbs
6s - 22s 7 5.2
28s 17 12.6
35s 20 14.8
42s 34 25.2
Warning: Only authorized persons are allowed to operate this valve, as closing can cause
build-up of excessive pressure in the system.
Applicable to all common non-ammable refrigerants, excluding R717 andto noncorrosive
gases/liquids dependent on sealing material compatibility.
The design pressure shall not be less than the value outlined in Section 9.2 of ANSI/
ASHRAE 15 for the refrigerant used in the system.
Danfoss
9G219.10
Component
to be insulated
2 DKRCC.PI.FB0.C2.02 / 520H8640 © Danfoss A/S (AC-MCI / sw), 2014-08
Tighten cap
Tighten the cap with approx. torque
Install Schrader valve
and cap (if present)
4
5
Brazing
Danfoss
9G156.14
Min. 5% Ag
3
Danfoss
9G207
Danfoss
9G207
Max. 150°C
(300°F)
Danfoss
9G207
Danfoss
9G209.10
Fully open
Fully closed
Valve size
Max. Torque
Nm ft-lbs
6s - 22s 15 11.0
28s - 35s 20 14.8
42s 32 23.6
Install Schrader valve
with approx. torque
0.3 Nm / 0.2 ft-lbs
/