Bryant FMU Product information

Type
Product information

This manual is also suitable for

Bryant FMU is a fan coil unit designed to provide heating and cooling for residential and commercial spaces. It features an ECM motor for energy efficiency and quiet operation, and a variety of wiring diagrams to suit different applications. The FMU can be used in both cased and uncased models, and is compatible with a variety of thermostats. Here are some of the key features and capabilities of the Bryant FMU:

  • Energy efficiency: The ECM motor is designed to save energy while providing consistent airflow.
  • Quiet operation: The ECM motor also operates quietly, making the FMU a good choice for noise-sensitive areas.

Bryant FMU is a fan coil unit designed to provide heating and cooling for residential and commercial spaces. It features an ECM motor for energy efficiency and quiet operation, and a variety of wiring diagrams to suit different applications. The FMU can be used in both cased and uncased models, and is compatible with a variety of thermostats. Here are some of the key features and capabilities of the Bryant FMU:

  • Energy efficiency: The ECM motor is designed to save energy while providing consistent airflow.
  • Quiet operation: The ECM motor also operates quietly, making the FMU a good choice for noise-sensitive areas.
496 03 8101 00 1/15/18
Specifications subject to change without notice.
WIRING DIAGRAM MANUAL
Horizontal Fan Coil
FMC4Z, FMU4Z, FMC4X, FMU4X
DANGER, WARNING, CAUTION, and
NOTE
The signal words DANGER, WARNING,
CAUTION, and NOTE are used to identify levels of
hazard seriousness. The signal word DANGER is
only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION,
and NOTE will be used on product labels and
throughout this manual and other manuals that may
apply to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
Signal Words in Manuals
The signal word WARNING is used throughout this
manual in the following manner:
The signal word CAUTION is used throughout this
manual in the following manner:
Signal Words on Product Labeling
Signal words are used in combination with colors
and/or pictures on product labels.
WARNING
Safety Labeling and Signal Words
!
!
CAUTION
WARNING
TABLE OF CONTENTS
FMC4Z, FMU4Z 11/2 ton Wiring Diagram, ECM Motor 2....
FMC4Z, FMU4Z 2 ton Wiring Diagram, ECM Motor 3.......
FMC4Z, FMU4Z 21/2 ton Wiring Diagram, ECM Motor 4....
FMC4Z, FMU4Z 3 ton Wiring Diagram, ECM Motor 5.......
FMC4X, FMU4X, PSC Motor 6...........................
EHK3 Wiring Diagram 7.................................
Thermostat Wiring Diagrams 8...........................
UNCASED MODELS
FMU4Z1800A1 FMU4X1800A1................
FMU4Z2400A1 FMU4X2400A1................
FMU4Z3000A1 FMU4X3000A1................
FMU4Z3600A1 FMU4X3600A1................
CASED MODELS
FMC4Z1800A1 FMC4X1800A1................
FMC4Z2400A1 FMC4X2400A1................
FMC4Z3000A1 FMC4X3000A1................
FMC4Z3600A1 FMC4X3600A1................
!
WARNING
DEATH, PERSONAL INJURY, AND/OR PROPERTY
DAMAGE HAZARD
Failure to carefully read and follow this warning
could result in equipment malfunction, property
damage, personal injury and/or death.
Installation or repairs made by unqualified per-
sons could result in equipment malfunction, prop-
erty damage, personal injury and/or death.
The information contained in this manual is in-
tended for use by a qualified service technician fa-
miliar with safety procedures and equipped with
the proper tools and test instruments.
Installation must conform with local building
codes and with the National Electrical Code
NFPA70 current edition or Canadian Electrical
Code Part 1 CSA C.22.1.
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 2
Specifications subject to change without notice.
FMU4Z, FMC4Z 11/2 ton Wiring Diagram, ECM Motor
A180006
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 3
Specifications subject to change without notice.
FMU4Z, FMC4Z 2 ton Wiring Diagram, ECM Motor
A180007
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 4
Specifications subject to change without notice.
FMU4Z, FMC4Z 21/2 ton Wiring Diagram, ECM Motor
A180008
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 5
Specifications subject to change without notice.
FMU4Z, FMC4Z 3 ton Wiring Diagram, ECM Motor
A180009
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 6
Specifications subject to change without notice.
FMU4X, FMC4X Wiring Diagram, PSC Motor
A170311
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 7
Specifications subject to change without notice.
EHK3 Wiring Diagram
A170312
WIRING DIAGRAM MANUAL Apartment Fan Coil: FMU4, FMC4
496 03 8101 00 8
Specifications subject to change without notice.
Thermostat Wiring Diagrams
Heat Pump with Electric Heater
A180010
BRN
BRN
H/P without Electric Heater
A180011
BRN
BRN
A/C System
A180013
BRN
Copyright 2018 CAC/BDP
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Bryant FMU Product information

Type
Product information
This manual is also suitable for

Bryant FMU is a fan coil unit designed to provide heating and cooling for residential and commercial spaces. It features an ECM motor for energy efficiency and quiet operation, and a variety of wiring diagrams to suit different applications. The FMU can be used in both cased and uncased models, and is compatible with a variety of thermostats. Here are some of the key features and capabilities of the Bryant FMU:

  • Energy efficiency: The ECM motor is designed to save energy while providing consistent airflow.
  • Quiet operation: The ECM motor also operates quietly, making the FMU a good choice for noise-sensitive areas.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI