Pulsar AWZ05121 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Pulsar AWZ05121 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AWZ 05121
v.1.1
AWZ 12V/1A/5x0,5A Linear power supply unit for CCTV
EN
Edition: 2 from the August 22, 2011
Supercedes edition: 1 from the 2
nd
February 2011
2
Features of the power supply unit:
five outputs protected independently by fuses
total output current: 1A
Safety equipment:
o SCP short-circuit protection
output voltage adjustment 11÷15V
o OLP overload protection
LED optical signalisation
o OHP overheat protection
o OVP overvoltage protection
o Surge protection
o Against sabotage
CONTENTS:
1. Technical description.
1.1. General description.
1.2. Block diagram
1.3. Description of elements and power supply connectors
1.4. Technical parameters
2. Installation.
2.1. Requirements
2.2. Installation procedure
3. Indication of power supply operation.
3.1. Optical signaling
4. Service and operation.
4.1. Short-circuit protection
4.2. Overload protection
4.3 Maintenance
1. Technical description.
1.1. General description.
Buffer power supply unit is designed for the supply of equipment requiring the stabilized voltage of 12V DC
(11,0V÷15,0V DC) and the total output current of 1.0A.
Information about types:
Model Description
AWZ05122
12V/DC stabilized linear power supply unit with five independent
outputs, protected by fuses or PTC. The total current capacity
2A@12V, with output voltage adjustment. Metal casing IP20 with a
space for a LED signalization panel.
AWZ09123
12V/DC stabilized linear power supply unit with nine independent
outputs, protected by fuse elements or polymer fuses PTC. The total
current capacity 3A@12V, with output voltage adjustment. Metal
casing IP20 with a space for a LED signalization panel.
3
1
.2. Block diagram (fig.1).
Fig.1. Block diagram of the power-supply unit.
1.3
. Description of elements and power supply connectors (tab.1, tab.2, fig.2).
Table 1.
Element no
[Fig. 2]
Description
[1]
L1, L2, L 3, L4, L5 optical signaling of outputs status
~AC~ AC supply signaling (only PCB)
[2] F1, F2, F3, F4, F5 fuses in the output circuit (DC)
[3] P1 voltage adjustment, output voltage adjustment
[4] OUTPUTS of power supply unit connector (Tab.2)
[5] F fuse in the power supply circuit (230V AC)
[6]
L-N power-supply connector 230V AC, PE protection connector
[7]
TAMPER micro-switch (contacts) of the anti-sabotage protection (NC)
[8]
Jumper of the change in PTC/fuse-element safety device type:
Tab.1. Power-supply unit elements.
Table 2.
[4] Description of power-supply unit outputs
+O1,+O2,+O3, +O4,
+O5
Supply output DC: +U
- (x3) Supply output DC: -U (GND, common terminal)
~AC~ Supply input AC
Tab.2. Power supply unit output terminals.
4
Fig.2. The view of the power-supply unit.
5
1.4. Technical parameters:
- electrical parameters (tab.3)
- mechanical parameters (tab.4)
- operation safety (tab.5)
- operation parameters (tab.6)
Electrical parameters (tab. 3).
Supply voltage 230V AC (-15%/+10%)
Supply frequency 50Hz (47÷53Hz)
PSU power P 12W max.
Current consumption 0.15A/230V
Output voltage 12,0V DC nom.
Output voltage setting, escalation and keeping
time
40ms/70ms/20ms
Voltage setting range 11,0V÷15,0V DC (-5%/+5%), 1x P1 adjustment
Output current 5x 0,2A for fuses F500 mA, ΣI= 1,0A max (total, uninterrupted)
Short-circuit protection SCP
5x F 500mA fuses (damage, fuse-element replacement required)
or PTC 500mA - set by jumper
Overload protection OLP
110% ÷ 150% of power supply - limitation with the PTC automatic
fuse, reset requires disconnecting load or supply for about 1 min.
Overvoltage protection OVP >17V (-/+ 5%)
Surge protection Varistors
TAMPER output indicating the opening of
the power supply casing
- micro-switch, NC contacts (closed casing, mounted on
foundation), 0.5A@50V DC (max)
Optical indication:
diodes L1÷L5 (green)
diode AC (red, on PCB of supply unit)
- outputs status +O1…+O5:
normal status = lights
failure status= does not light
- supply status AC:
normal status = lights
failure status= does not light
Fuse F
Fuse F1÷F5
T 200mA/250V
F 500mA/ 250V
Mechanical parameters (tab. 4).
Casing dimensions 175 x 185 x 88 (170 x 180 x 80) (WxHxD)
Fixation 145 x 174 x Φ 6 WxH
Net/gross weight 1,6/1,7 kg
Casing color RAL 9003
Closing Cheese screw: at the front of the casing
Connectors Supply 230V AC: Φ0,63-2,05 (AWG 22-12)
DC outputs: Φ0,51- 2,05 (AWG 24-12)
Notes The casing is distant from the assembly surface so that cables can be installed
convection cooling
Operation safety
(tab.5).
Protection class PN-EN 60950-1:2004 I (first)
Protection grade PN-EN 60529: 2002 (U) IP20
Electrical strength of insulation:
- between input (network) circuit and output circuits of power-supply (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Operation parameters
(tab.6).
Operation temperature -10ºC...+40ºC
Storage temperature +5ºC...+40ºC
Relative humidity 30%...90%, without condensation
Vibrations during operation Unacceptable
Impulse waves during operation Unacceptable
Direct isolation Unacceptable
Vibrations and impulse waves during transport According to PN-83/T-42106
6
2.
Installation
.
2.1 Requirements.
The buffer power-supply shall be mounted by the qualified installer having appropriate (required and necessary
for a given country) permissions and qualifications for connecting (operating) 230V AC installations and low-voltage
installations. The device shall be mounted in closed rooms, according to the environment class II, of the normal air
humidity (RH=90% max. without condensation) and the temperature within the range from -10°C to +40°C. The power-
supply shall operate in a vertical position so that free and convectional air flow through ventilating holes of the casing is
guaranteed.
Before installation is started, the balance of the power-supply load shall be performed. During the normal
operation, the sum of currents collected by receivers shall not exceed I=1A (P=12W max.). It is acceptable to
change values of fuses to other than original, if not all outputs of power supply are used and Pmax is not
exceeded.
As the power-supply is designed for a continuous operation and is not equipped with a power-switch, therefore
an appropriate overload protection in the power supply circuit shall be guaranteed. Moreover, the user shall be informed
about the method of isolation of the power supply from the power voltage (usually through assignment and marking of
an appropriate fuse in the fuse-box). The electrical system shall be made in accordance with valid standards and
regulations.
2.2 Installation procedure.
1. Before installation is started, the voltage in the 230V power-supply circuit shall be isolated.
2. The power-supply shall be mounted in a selected location and connection cords shall be lead.
3. Remove the power fuse protecting the power supply circuit.
4. The power cables (~230VAC) shall be connected to L-N terminals of the power supply. The earth conductor shall be
connected to the terminal marked by the earth symbol . The connection shall be made by means of a three-core cable
(with a yellow and green PE protection cable). The power cables shall be lead to appropriate terminals of the connection
board through bushing.
The circuit of the shock protection shall be performed with a particular care, i.e. the yellow and green
protection wire of the power cable shall be connected from one side to the terminal marked by the symbol of
in the casing of the power-supply. Operation of the power-supply without the properly made and fully
operational circuit of the shock protection is UNACCEPTABLE!. It can result in failure of devices and electric
shock.
5. Connect the conductors of consumers to: +O1 -…..+O5 - (maintaining polarization).
6. As there are significant voltage drops at the resistance of power cables of receivers during installation, it is possible to
adjust a voltage value by P1 potentiometer (11,0V÷15,0V DC).
7. Insert the fuse into the power supply circuit and switch on power.
8. Check the optical signaling of the power supply.
9. After installation is completed and operation of the power-supply is checked, the casing can be closed.
3. Power supply unit operation indication.
The power-supply is equipped with the optical signaling of operation modes. Voltage at the outputs of the power
supply is indicated by lighting of green LEDs at the front panel of the device.
3.1 Optical signaling (fig.3.)
Green LEDs L1….L5 indicate the power-supply mode at outputs: +O1…..+O5.
If power supply is lost at an output (fuse blow), a correspondent LED stops lighting
(L1 for +O1, L2 for +O2 etc.).
The red LED AC indicates supply status at power supply unit input. In case of supply loss at input (lack of
230V AC, F failure) the diode stops lighting.
7
Fig.3. The view of LED panel.
4.
Service and operation
.
4.1 Procedure in case of short-circuit (activation of SCP) of the power supply output.
Outputs of the O1÷O5 power supply are protected against short-circuits with fuse-element safety device (inserts)
or PTC. In case of damaging fuse-element safety device it is necessary to exchange the fuse (compliant with the
original).
If PTC polymer fuses protection was chosen, then automatic disconnection of the output voltage was signalled by
switching off the green diode. It is then necessary to disconnect the load from the power supply output for the period of
about 1 min.
It is acceptable to change values of fuses to other than original, if not all outputs of power supply are used
and Pmax is not exceeded.
4.2 Procedure in case of overload (activation of OLP) of the power-supply.
The main output of the power supply unit is equipped with the PTC polymer fuse assisted protection. If the load
of the PSU exceeds 1A (load 110% ÷ 150% @25ºC of the PSU power), the output voltage is automatically disconnected
and this is indicated by all diodes going off. The voltage at the output may be restored by disconnecting the output load
or 230V AC supply for the period of about one minute.
4.3 Maintenance.
All maintenance operations can be performed after the power supply is disconnected from the power network. As
for the power supply, it is not necessary to perform any special maintenance operations, but if the power supply interior
is significantly dusty, it shall be vacuum-cleaned by compressed air. In case of fuse replacement, the spare parts shall be
the same as original ones.
8
WEEE MARK
The waste electric and electronic products do not mix with general household
waste. There are separate collection system for used electric and electronic
products in accordance with legislation under the WEEE Directive and is
effective only with EU.
GENERAL WARRANTY CONDITIONS
1. Pulsar K. Bogusz Sp.j. (manufacturer) grants a two-year quality warranty for the equipment, starting from the date of purchase
placed on the purchase order.
2. Should such purchase order be missing when the claim is submitted, the three-year guarantee period is counted from the date
of the manufacturing of the device.
3. The warranty includes free-of-charge repairing or replacing with a functional equivalent (the selection is made by the
manufacturer) of the malfunctioning device, due to reasons attributable to the manufacturer, including manufacturing and
material defects, unless such defects have been reported beyond the warranty period (item 1 and 2).
4. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the
manufacturer.
5. The warranty applies to complete equipment, including the type of defect specified in writing, using a properly filled warranty
claim.
6. Should the claim be accepted, the manufacturer is obliged to render warranty repairs, as soon as possible, however not later
that within 14 days from the delivering of the equipment to the service centre of the manufacturer.
7. The repair period mentioned in item 5 may be prolonged, if there is no technical capability to carry out the repairs, and in the
case that the equipment has been accepted conditionally, due to the failing of the warranty terms by the claimant.
8. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.
9. The warranty does not cover the defects of the equipment, resulting from:
- reasons beyond the manufacturer's control,
- mechanical damage,
- improper storage and transport,
- use that violates the operation manual or equipment application,
- random events, including lightning discharges, failures of power networks, fire, flooding, high temperatures and chemical
agents,
- improper installation and configuration (at variance with the rules set forth in the manual),
10. Each confirmation of structural modifications or repairs, carried out beyond the service centre of the manufacturer, or any
modification of serial numbers or warranty labels, results in the loss of the rights resulting from the warranty.
11. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the
wholesale prices suggested by the manufacturer on the day of purchase.
12. The manufacturer shall not be responsible for the defects that resulted from the damaging, malfunctioning or inability to
operate the equipment, particularly, if such defects are the result of failing to abide by the recommendations and requirements
contained in the manual, or the use of the equipment.
Pulsar K.Bogusz Sp.j.
Siedlec 150,
32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
http:// www.pulsar.pl
/