Mi-T-M HHB Series Owner's manual

Category
High-pressure cleaners
Type
Owner's manual

This manual is also suitable for

Operator's Manual 1
©Copyright 2006 Form #37-0890-E/F/S-030514
CAUTION
RISK OF INJURY!
READ MANUAL BEFORE OPERATING!
This manual is an important part of the pressure washer and must
remain with the unit when you sell or rent it!
OPERATOR'S MANUAL FOR
HHB and HHS-SERIES
HOT WATER
PRESSURE WASHERS
2 Operator's Manual
TABLE OF CONTENTS
INTRODUCTION .......................................................................................................................3
IMPORTANT SAFETY INSTRUCTIONS .............................................................................. 4-7
RISK OF ELECTRIC SHOCK OR ELECTROCUTION .................................................4
RISK OF EXPLOSION OR FIRE ..................................................................................5
RISK OF ASPHYXIATION ...........................................................................................5
RISK OF INJECTION OR SEVERE CUTTING INJURY ...............................................6
RISK OF BURNS ..........................................................................................................6
RISK OF BURSTING ....................................................................................................6
RISK FROM MOVING PARTS ......................................................................................6
RISK OF BODILY INJURY ............................................................................................7
FEATURES ........................................................................................................................... 8-9
INSTALLATION & PREPARATION .................................................................................. 10-13
ATTIRE .......................................................................................................................10
SETUP ........................................................................................................................10
OPTIONAL STACK ADAPTER-VENTILATION INSTRUCTIONS ...............................10
POWER CORD CONNECTION ..................................................................................11
BURNER FUEL TANK ................................................................................................11
ADJUSTABLE PRESSURE DUAL LANCE .................................................................12
DUAL LANCE CONNECTION ....................................................................................12
WATER SUPPLY .........................................................................................................12
UNLOADER ................................................................................................................12
THERMAL RELIEF VALVE .........................................................................................13
PRE-START INSPECTION PROCEDURES ...............................................................13
OPERATING INSTRUCTIONS ......................................................................................... 14-17
FLUSHING THE SYSTEM ..........................................................................................14
START-UP/COLD WATER OPERATION ....................................................................14
HOT WATER OPERATION .........................................................................................14
OPTIONAL STEAM OPERATION ...............................................................................15
CLEANING WITH DETERGENTS ..............................................................................16
SHUTDOWN ...............................................................................................................17
OPTIONS ....................................................................................................................17
STORAGE & MAINTENANCE .......................................................................................... 18-21
MAINTENANCE CHART .............................................................................................18
DAILY ..........................................................................................................................19
3 MONTHS .................................................................................................................20
6 MONTHS .................................................................................................................21
12 MONTHS ...............................................................................................................21
SEASONAL-WINTERIZING ........................................................................................21
TROUBLESHOOTING ...................................................................................................... 22-24
STATEMENT OF WARRANTY ...............................................................................................25
Warning: This product contains lead, a
chemical known to the State of California
to cause birth defects or other reproductive
harm.
Wash your hands after handling this product.
Operator's Manual 3
INTRODUCTION
Congratulations on the purchase of your new HHS-Series hot water pressure washer! You can be assured your hot
water pressure washer was constructed and designed with quality and performance in mind. Each component has been
rigorously tested to ensure the highest level of acceptance.
This operator's manual was compiled for your benet. By reading and following the simple safety, installation, operation,
maintenance and troubleshooting steps described in this manual, you will receive years of trouble free operation from
your new hot water pressure washer. The contents of this manual are based on the latest product information available
at the time of publication. The manufacturer reserves the right to make changes in price, color, materials, equipment,
specications or models at any time without notice.
! IMPORTANT !
These paragraphs are surrounded by a "SAFETY ALERT BOX". This box is used to designate and
emphasize Safety Warnings that must be followed when operating this pressure washer.
Accompanying the Safety Warnings are "signal words" which designate the degree or level
of hazard seriousness. The "signal words" used in this manual are as follows:
DANGER: Indicates an imminently hazardous situation which, if not avoided, WILL
result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, COULD
result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided MAY
result in minor or moderate injury.
The symbols set to the left of this paragraph are "Safety Alert Symbols". These symbols
are used to call attention to items or procedures that could be dangerous to you or other
persons using this equipment.
ALWAYS PROVIDE A COPY OF THIS MANUAL TO ANYONE USING THIS EQUIPMENT. READ
ALL INSTRUCTIONS BEFORE OPERATING THIS PRESSURE WASHER AND ESPECIALLY
POINT OUT THE "SAFETY WARNINGS" TO PREVENT THE POSSIBILITY OF PERSONAL
INJURY TO THE OPERATOR.
Once the unit has been uncrated, immediately write in the serial number of your unit in the space provided below.
SERIAL NUMBER_________________________________
Inspect for signs of obvious or concealed freight damage. If damage does exist, le a claim with the transportation
company immediately. Be sure that all damaged parts are replaced and that the mechanical and electrical problems
are corrected prior to operation of the unit. If you require service, contact your customer service.
Please have the following information available for all service calls:
1. Model Number
2. Serial Number
3. Date and Place of Purchase
4 Operator's Manual
IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using this product, basic precautions should always be observed, including the following:
READ ALL SAFETY WARNINGS BEFORE USING PRESSURE WASHER
POTENTIAL CONSEQUENCE
PREVENTION
Serious injury or death could occur if
the pressure washer is not properly
grounded. Your pressure washer
is powered by electricity and may
cause electric shock or electrocution
if not used properly.
Electrical shock may occur from
electrical cord.
Electrical shock may occur if
pressure washer is not operated
properly.
Serious injury or death may occur if
electrical repairs are attempted by
unqualied persons.
This product must be grounded. Make sure
the pressure washer is equipped with a GFCI
built into the power supply cord. If this is not
available, the pressure washer must be plugged
into a receptacle that is protected by a GFCI.
Disconnect when not in use.
If your unit is equipped with a GFCI, DO
NOT drop the GFCI as damage could
result. If the GFCI is accidentally dropped,
be certain to test the GFCI before using
to ensure it is working properly. (Follow
instructions on GFCI for test procedures.)
Always be certain the unit is receiving proper
voltage. Before plugging the unit into a
compatible power source, be certain the
switch is in the "OFF" position. Disconnect
when not in use.
Do not modify the electrical plug. If it will not
t the outlet, have a proper outlet installed by
a qualied electrician. Do not use any type
of adapter.
Check power cord for signs of crushing, cutting
or heat damage. If replacement of plug or
cord is needed, use only identical replacement
parts.
Do not use extension cords with this pressure
washer.
Keep all connections dry and off the ground.
Do not allow electrical cords to lay in water or
in such a position where water could come
in contact with them. Do not touch plug with
wet hands.
Do not pull on the electrical cord to disconnect
from the outlet.
DO NOT direct spray on or into electrical
installations of any kind! This includes electrical
outlets, light bulbs, fuse boxes, transformers,
the unit itself, etc.
DO NOT allow metal components of the
pressure washer to come in contact with live
electrical components.
Never operate the pressure washer with safety
guards/covers removed or damaged.
Any electrical wiring or repairs performed on this
pressure washer should be done by Authorized
Service Personnel in accordance with National
and Local electrical codes.
Before opening any electrical enclosure, always
shut off the pressure washer, relieve pressure
and unplug the pressure washer from the power
source. Allow the pressure washer to cool
down. Never assume the pressure washer is
safe to work on just because it is not operating.
It could restart at any time! Service in a clean,
dry, at area.
RISK OF
ELECTRIC SHOCK
OR
ELECTROCUTION
HAZARD
Operator's Manual 5
POTENTIAL CONSEQUENCE
PREVENTION
IMPORTANT SAFETY INSTRUCTIONS
READ ALL SAFETY WARNINGS BEFORE USING PRESSURE WASHER
RISK OF
EXPLOSION OR FIRE
Serious injury or death may occur
from normal sparks in the multiple
ignition sources or burner exhaust.
Serious injury or death may occur as
a result of improper fueling.
Serious injury or death may occur
if system safety's are not properly
maintained.
Always operate pressure washer in a well
ventilated area free of ammable vapors,
combustible dust, gases or other combustible
materials.
Do not store the pressure washer near an
open ame or any equipment such as a stove,
furnace, water heater, etc., which utilizes a pilot
light or sparking device.
Do not use this pressure washer to spray
ammable material!
Do not smoke while lling burner fuel tank.
Never ll the burner fuel tank while the pressure
washer is running or hot. Allow to cool two
minutes before refueling.
Do not refuel in a poorly ventilated area.
Always refuel slowly to avoid the possibility of
spilled fuel which may cause a risk of re.
Burner Fuel Tank:
Use No. 1 or No. 2 fuel oil/diesel or
kerosene.
Do not use gasoline, crankcase drainings or
oil containing gasoline or solvents.
Do not operate the unit if fuel is spilled. Wipe
the pressure washer clean and move it away
from the spill. Avoid creating any ignition until
the fuel has evaporated.
This pressure washer has a Safety Relief
device which should never be altered, modied,
removed or made inoperative. If the device
fails, replace immediately with only genuine
manufacturer replacement part.
HAZARD
Serious injury or death may occur
from inhaling burner exhaust or
dangerous vapors.
Never operate this pressure washer in an
enclosed area. Always make certain there
is adequate ventilation (fresh outside air) for
breathing and combustion. This will prevent
the build up of dangerous carbon monoxide
gases. Beware of poorly ventilated areas, or
areas with exhaust fans which can cause poor
air exchange.
Follow all safety instructions provided with the
materials you are spraying. Use of a respirator
may be required when working with some
materials. Do not use this pressure washer
to dispense hazardous detergents.
RISK OF
ASPHYXIATION
6 Operator's Manual
RISK OF BURNS
RISK FROM MOVING PARTS
Serious injury may occur from touching
the heat exchanger. This area can
remain hot for some time after the
pressure washer is shutdown.
Serious injury may occur from a
pressure washer malfunction or
exploding accessories if incorrect
system components, attachments or
accessories are used.
Serious injury or death may occur
if attempting to start the pressure
washer when the unit pumping system
is frozen.
Serious injury may occur to the
operator from moving parts on the
pressure washer.
Never make adjustments to the factory set
pressures.
Never exceed manufacturers maximum allowable
pressure rating of attachments.
Do not allow any hoses to make contact with heat
exchanger to prevent the possibility of bursting.
Avoid dragging the hoses over abrasive surfaces
such as cement.
Use only manufacturer recommended repair parts
for your pressure washer.
In freezing temperatures, the unit must always be
warm enough to ensure there is no ice formation
in the pump. Do not start the pressure washer if
it has been transported in an open or underheated
vehicle without rst allowing the unit pumping
system to thaw.
RISK OF BURSTING
Do not operate the unit without all protective
covers in place.
Follow the maintenance instructions specied in
the manual.
Never make adjustments to the unit while it is
connected to the power source.
Never allow any part of your body to contact the
heat exchanger.
Do not leave unit unattended after shutdown until
it is completely cooled down as described in the
"SHUTDOWN" procedures listed on page 18 of
this manual.
POTENTIAL CONSEQUENCE
PREVENTION
IMPORTANT SAFETY INSTRUCTIONS
READ ALL SAFETY WARNINGS BEFORE USING PRESSURE WASHER
Serious injury or death could occur
from high pressure spray penetrating
the skin.
Keep clear of nozzle and spray! Never put your hand,
ngers or body directly over the spray nozzle.
Never point the high pressure discharge spray at
yourself or anyone else.
This product is to be used only by trained operators.
Close supervision is necessary when used near
children.
Always keep operating area clear of all persons.
DO NOT allow children to operate this unit.
SEEK EMERGENCY MEDICAL CARE if the spray
appears to have penetrated the skin! DO NOT
TREAT AS A SIMPLE CUT!!
High pressure hoses and fuel lines should be
inspected daily for signs of wear. If evidence of
failure exists, promptly replace all suspect hoses
and fuel lines to prevent the possibility of injury
from the high pressure spray. If a hose or tting is
leaking, NEVER PLACE YOUR HAND DIRECTLY
ON THE LEAK.
NEVER operate the gun with the trigger wired in
the open position. To prevent accidental discharge,
the trigger gun should be securely locked when not
in use.
Before removing the spray nozzle or servicing the
unit, ALWAYS shut off the unit and trigger the gun
to release trapped pressure. (Even after you shut
off the unit, there is high pressure water left in the
pump, hose and gun until you release it by triggering
the gun.)
RISK OF INJECTION
OR
SEVERE CUTTING INJURY
HAZARD
Operator's Manual 7
RISK OF BODILY INJURY
IMPORTANT SAFETY INSTRUCTIONS
READ ALL SAFETY WARNINGS BEFORE USING PRESSURE WASHER
Serious injury or death may occur
from detergents contacting the skin.
Serious injury can occur from loose
debris being propelled at a high speed
from the spray gun.
Injury may occur if the operator loses
his balance caused by the thrust of
water traveling through the spray
nozzle.
Injury may occur from the pressure
washer.
SEEK EMERGENCY MEDICAL CARE if you are
using cleaning agents and the spray appears to
have penetrated the skin! DO NOT TREAT AS
A SIMPLE CUT! Be prepared to tell a physician
exactly what kind of detergents you were using by
reading the Material Safety Data Sheet (MSDS)
provided with your detergent.
Never use any solvents or highly corrosive detergents
or acid type cleaners with this pressure washer.
Protective equipment such as rubber suits, gloves
and respirators are advisable, especially when using
cleaning detergents.
Keep all detergents out of the reach of children!
ALWAYS wear protective goggles when operating
the unit to shield the eyes from ying debris and
detergents.
DO NOT direct spray toward fragile materials such
as glass because shattering could occur.
This pressure washer is equipped with an Auto
start/stop feature, the unit will shutdown until
the gun is triggered. To prevent accidental high
pressure discharge, do not leave unit unattended
while in this mode.
Stay alert-watch what you are doing. Do not operate
the unit when fatigued or under the inuence of
alcohol or drugs.
NEVER squeeze the trigger unless securely
braced.
DO NOT overreach or stand on unstable support.
Wet surfaces can be slippery, wear protective foot
gear and keep good footing and balance at all
times.
NEVER trigger the gun while on a ladder or roof.
ALWAYS hold on rmly to the gun/lance assembly
when starting and operating the unit. Failure to do so
can cause the lance to fall and whip dangerously.
Know how to stop the pressure washer and bleed
pressures quickly. Be thoroughly familiar with
controls.
DO NOT leave pressurized unit unattended. Shut off
the pressure washer and release trapped pressure
before leaving.
DO NOT operate the unit if you see any fuel, oil or
water leaks from the machine. DO NOT resume
operation until the unit has been inspected and
repaired by a qualied service person.
Place unit in a clean, dry, at area for servicing.
Before servicing the unit: turn the unit off, relieve
the water pressure from the trigger gun, and allow
the unit to cool down. Service in clean, dry, at area.
Engage the brake to prevent unit from moving.
Do not move the unit by pulling on the hose.
POTENTIAL CONSEQUENCE
PREVENTION
!SAVE THESE INSTRUCTIONS!
HAZARD
Operator's Manual 9
FEATURES LISTING
1. Flat Free Wheels
2. Brake
3. Access Panel
4. Wand Holder
5. Water Inlet
6. Water Float Tank
7. Push/Pull Handle w/Rubber Grip
8. Stack Adapter Kit (Optional)
9. Heat Exchanger Exhaust
10. Burner Air Adjustment
11. Fuel Filter/Water Separator
12. Protective Cage for Fuel Tank & Burner
13. Pump Motor
14. High Pressure Pump
15. Pressure Switch-Burner Control
16. Unloader
17. Water Outlet
18. Safety Relief Valve
19. Detergent Strainer
20. Decal-Data Plate
21. Power Cord (w/GFCI on 1002/1003 & 2004-1E2G)
22. Burner Fuel Tank
23. Control Panel
24. Switch-Pump
25. Switch-Burner
26. Switch-Main
27. Adjustable Thermostat
28. Water Strainer
29. Detergent Metering Valve
30. High Pressure Hose
31. Trigger Gun
32. Trigger Safety Lock
33. Insulated Lance
34. Adjustable Pressure Dual Lance
35. High Pressure Nozzle
SPECIFIC UNIT INFORMATION
FRAME: Solid steel axles, push/pull handle with rubber grip.
PORTABILITY: Four pneumatic tires for easy mobility.
FINISH: Powder coated chassis with stainless steel heat exchanger.
HIGH PRESSURE HOSE: 3/8" x 50'.
TRIGGER GUN ASSEMBLY: Trigger controlled, safety lockoff,
insulated lance.
DUAL LANCE: Insulated, with adjustable pressure.
10 Operator's Manual
SETUP:
1. This unit should only be placed on a level surface to ensure proper lubrication
for the water pump while operating. NEVER spray water directly on the
unit.
2. Do not use unit in an area:
a. with insufcient ventilation.
b. where there is a combustible cealing, unless suitable stack venting is
installed.
c. where there is evidence of oil or fuel leaks.
d. where ammable gas vapors may be present.
3. Be certain to engage the brake to prevent the unit from moving while
operating. Allow sufcient clearances around unit for accessibility.
4. Do not allow the unit to be exposed to rain, snow or freezing temperatures.
If any part of the unit becomes frozen, excessive pressure may build up in
the unit which could cause it to burst resulting in possible serious injury to
the operator or bystanders.
5. Pump oil level should be checked before each use. Make certain the oil is
on the "Full" mark on the dipstick or in the center of the oil sight glass. If
the level appears to be low, ll with SAE20 or 30 non-detergent pump oil.
ATTIRE:
Proper attire is essential to your safety. It is advised to utilize whatever means
necessary to protect eyes, ears, and skin. Additional safety attire (such as
respiratory mask) may be required when using detergent cleaning agents with
this washer.
OPTIONAL STACK ADAPTER – VENTILATION INSTRUCTIONS
1. Installation of this unit, in an indoor or enclosed environment, should be
performed by a qualied HVAC technician. Additionally, venting must
conform to all local, state, and federal codes. Refer to NFPA 31 and CAN/
CSA B139-M91, where applicable.
2. Exhaust gases must not be vented into a wall, a ceiling, or a concealed
space of a building.
3. 8” ue pipe must be used to match the size of the stack adapter accessory.
The ue pipe should be kept as short as possible and be installed so that it
has a continuous rise to the chimney. Elbows must be kept to an absolute
minimum to maintain the forced air draft in the system and ensure good
burn quality.
4. If the unit is being installed in an enclosed room, an adequate air supply
must be provided to burner by installing openings near the oor. These
openings should be at least one square inch per 1000 BTU input of the
machine. Also, a ventilation opening must be installed near the ceiling.
This opening should be at least the same size as the supply opening near
the oor. Refer to NFPA 31 and CAN/CSA B139-M91, where applicable.
5. If the burner is located in a tightly constructed building where there is
inadequate outside air inltration, outside combustion air must be supplied by
some other means. One method to accomplish this is through a permanent
opening, or openings, in an exterior wall. The total free area of the opening(s)
must not be less than one square inch per 5,000 BTU input. All appliances
must be taken into consideration. Refer to NFPA 31 and CAN/CSA B139-
M91, where applicable.
INSTALLATION & PREPARATION
WARNING
RISK OF ASPHYXIATION!
USE THIS PRODUCT ONLY IN
WELL VENTILATED AREAS! THE
EXHAUST CONTAINS CARBON
MONOXIDE, A POISONOUS,
ODORLESS AND INVISIBLE
GAS. BREATHING THIS GAS
CAN CAUSE SERIOUS INJURY,
ILLNESS & POSSIBLE DEATH.
DANGER
RISK OF EXPLOSION OR FIRE!
DO NOT PLACE UNIT IN AN
AREA WHERE FLAMMABLE
GAS VAPORS MAY BE PRESENT.
A SPARK COULD CAUSE AN
EXPLOSION OR FIRE!
RISK OF UNIT BURSTING!
DO NOT STORE/OPERATE UNIT
IN FREEZING ENVIRONMENTS!
Operator's Manual 11
WARNING
RISK OF EXPLOSION OR FIRE!
ALWAYS STORE FUEL AWAY
FROM THE WASHER WHILE THE
UNIT IS RUNNING OR HOT.
INSTALLATION & PREPARATION
POWER CORD CONNECTION:
1. Make certain both switch are in the "OFF" position.
2. Ensure electrical supply is identical to the specications listed on the
pressure washer data plate.
3. GROUNDING INSTRUCTIONS: This product must be grounded. If
it should malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock.
This product is equipped with a cord having an equipment-grounding
conductor. The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local codes and
ordinances.
4. DANGER: Improper connection of the equipment-grounding conductor
can result in a risk of electrocution. Check with a qualied electrician or
service personnel if you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug - if it will not t the outlet, have a proper
outlet installed by a qualied electrician. Do not use any type of adaptor
with this product.
5. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION:
a. SINGLE PHASE: If this pressure washer is provided with a Ground
Fault Circuit Interrupter (GFCI) built into the plug or the power supply
cord, test the GFCI each time it is plugged into an outlet according
to instructions on the GFCI. DO NOT use the pressure washer if
the test fails! The GFCI provides additional protection from the risk
of electric shock. Should replacement of the plug or cord become
necessary, use only identical replacement parts that include GFCI
protection.
b. SINGLE PHASE: If this pressure washer is not provided with a GFCI,
this pressure washer should only be connected to a receptacle that
is protected by a Ground Fault Circuit Interrupter (GFCI) to comply
with the National Electric Code (NFPA 70) and to provide additional
protection from the risk of electric shock.
c. THREE PHASE: These pressure washers are not provided with
GFCI protection.
6. EXTENSION CORDS: THE MANUFACTURER DOES NOT
RECOMMEND THE USE OF EXTENSION CORDS! If use of an
extension cord is unavoidable, it must be plugged into a GFCI found in
circuit boxes or protected receptacles. When using an extension cord,
consult a qualied electrician to determine the proper wire gauge needed
for the length of the extension cord.
SINGLE PHASE: Use only 3-wire extension cords that have 3-prong
grounding-type plugs and 3-pole cord connectors that accept the plug
from the product.
THREE PHASE: Use only 4 wire extension cords that have 4-prong grounding
type plugs and 4-pole cord connectors that accept the plug from the
product.
Use only extension cords that are intended for outdoor use. These
extension cords are identied by a marking "Acceptable for use with
outdoor appliances; store indoors while not in use." Use only extension
cords having an electrical rating not less than the rating of the product.
Do not use damaged extension cords. Examine extension cord before
using and replace if damaged. Do not abuse extension cord and do
not pull on any cord to disconnect. Keep cord away from heat and
sharp edges. Always connect or disconnect the extension cord from
the receptacle before connecting or disconnecting the product from the
extension cord.
7. Ensure the area between the pressure washer cord and outlet is kept
dry.
8. Insert the male plug into a grounded AC outlet. DO NOT use an adapter
OR remove the grounding plug!!
BURNER FUEL TANK:
1. Review "Risk of Explosion or Fire" pg. 5, before fueling.
2. Locate the Safety Decals on your unit and heed their warnings.
3. Fill the burner fuel tank with good quality, clean No. 1 or No. 2 fuel oil/
diesel or kerosene. Do not use gasoline!
DANGER
RISK OF ELECTROCUTION!
THIS UNIT MUST BE CONNECTED
TO A PROPERLY GROUNDED
OUTLET. DO NOT USE AN
ADAPTER OR REMOVE THE
THIRD GROUNDING PRONG.
WARNING
RISK OF ELECTROCUTION!
TO REDUCE THE RISK OF
ELECTROCUTION, KEEP ALL
CONNECTIONS DRY AND OFF
THE GROUND. DO NOT TOUCH
PLUG WITH WET HANDS.
DANGER
RISK OF FIRE!
-DO NOT SMOKE WHILE
FUELING!
-DO NOT FILL THE FUEL TANK
WHILE UNIT IS RUNNING OR
HOT. ALLOW UNIT TO COOL
FOR TWO MINUTES BEFORE
REFUELING.
-DO NOT FILL FUEL TANK TO
POINT OF OVERFLOWING.
12 Operator's Manual
INSTALLATION & PREPARATION
ADJUSTABLE PRESSURE DUAL LANCE:
This unit features an Adjustable Pressure Dual Lance which allows the user to
select a high or low pressure "fan" spray. Simply rotate the adjustable grip on
the dual lance to achieve the desired pressure selection.
1. Selection of high pressure can be achieved by turning the adjustable grip
on the Dual Lance assembly counterclockwise as shown in the gure
below.
2. Selection of low pressure can be achieved by turning the adjustable grip on
the Dual Lance clockwise as shown in the gure below.
DUAL LANCE CONNECTION:
1. Be certain the trigger gun is locked in the "OFF" position.
2. Connect the dual lance assembly to the trigger gun assembly at this time (if
applicable). Be certain the connection is securely tightened.
WARNING
RISK OF INJECTION CAUSING
SEVERE INJURY!
-THE TRIGGER GUN SHOULD
ALWAYS BE LOCKED IN THE OFF
POSITION WHEN NOT IN USE!
-NEVER LOOK DIRECTLY AT
THE NOZZLE UNLESS IT IS
DISCONNECTED FROM THE
TRIGGER GUN/DUAL LANCE
ASSEMBLY!
A
A
WATER SUPPLY:
1. Select a water supply hose which is a quality grade of garden hose measuring
at least 3/4" ID and no longer than 50 feet.
2. Ensure the water strainers (A) are clean and free of any obstructions.
Periodic cleaning of the water strainer will help prevent pump problems.
As a strainer becomes obstructed, it restricts proper ow of water to the
pump. This can result in cavitation which will cause premature failure of
pump packings. Remove strainer screens (A), clean or replace.
3. Connect one end of the water supply hose to the water inlet of the unit.
Connect the other end of the hose to your pressurized water supply.
NOTE: If there is a high mineral content in your water, it is recommended that
a water softener be used to prevent the possibility of excessive scale
build up inside the heat exchanger coil.
4. Follow the incoming water requirements listed below:
a. Water pressure must be between a minimum of 20 pounds per square
inch (PSI) and a maximum of 125 PSI.
b. Incoming GPM must be approximately one gallon more than the outgoing
GPM stated on the pressure washer nameplate. (You can check GPM
by timing how long it takes to ll a 5 gallon container.)
c. Incoming water temperature must not exceed 125°F. Excessive pump
damage may result if the water temperature exceeds this acceptable
level.
5. Never allow the unit to operate without the incoming water line attached and
the water supply completely turned on.
UNLOADER:
The unloader has been preset at the factory.
Operator's Manual 13
INSTALLATION & PREPARATION
END OF PREPARATION INSTRUCTIONS
THERMAL RELIEF VALVE:
To ensure the water temperature does not exceed acceptable levels, never allow
the pressure washer to operate in the bypass mode (with the unit running and
the trigger closed) for more than ve minutes.
A "thermal relief valve" has been added to this unit to protect the pump. This valve
will open and release water if the water temperature in the pump has exceeded
140° F. This will allow fresh, cool water to enter the system, therefore preventing
premature failure of pump packings.
PRE-START INSPECTION PROCEDURES:
Before starting the unit, perform the following procedures:
1. Inspect the electrical cords for cuts. If a cut is found, DO NOT TOUCH OR
USE CORD! Replace cord before starting unit.
2. Check the oil level in the pump.
3. Inspect the water inlet strainer. Clean or replace if necessary. See "Water
Supply", #2, pg 12.
4. Check all hose connections to ensure they are securely tightened.
5. Inspect for system water leaks, oil leaks and fuel leaks. If a fuel leak is
found, DO NOT START UNIT! See "Risk of Explosion or Fire", pg. 5. Be
sure that all damaged parts are replaced and that the mechanical problems
are corrected prior to operation of the unit. If you require service, contact
Customer Service.
6. Inspect high pressure hoses for kinking, cuts and leaks. If a cut or leak
is found, DO NOT USE HOSE! Replace hose before starting unit. See
"Risk of Injection or Severe Cutting Injury", pg. 6. Be sure that all damaged
parts are replaced and that the mechanical problems are corrected prior to
operation of the unit. If you require service, contact Customer Service.
WARNING
THE FOLLOWING PAGES CONTAIN OPERATING AND
MAINTENANCE INSTRUCTIONS.
DO NOT ATTEMPT TO OPERATE THIS PRESSURE
WASHER UNTIL YOU HAVE READ AND UNDERSTOOD
ALL SAFETY PRECAUTIONS AND INSTRUCTIONS
LISTED IN THIS MANUAL.
INCORRECT OPERATION OF THIS UNIT CAN CAUSE
SERIOUS INJURY!!
DO NOT ALTER OR MODIFY THIS EQUIPMENT
IN ANY MANNER!
14 Operator's Manual
CAUTION
RISK OF DAMAGE.
DO NOT ALLOW SPRAY PATTERN
TO REMAIN ON A FIXED AREA
FOR AN EXTENDED PERIOD OF
TIME. POSSIBLE DAMAGE MAY
OCCUR TO THE AREA.
DANGER
RISK OF INJECTION CAUSING
SEVERE INJURY!
-KEEP CLEAR OF NOZZLE! NEVER
PLACE HAND OR FINGERS IN
FRONT OF NOZZLE!
-DO NOT DIRECT DISCHARGE
STREAM AT PEOPLE OR PETS!
-THIS PRODUCT IS TO BE
USED ONLY BY TRAINED
OPERATORS.
-AUTO START/STOP FEATURE
WILL SHUTDOWN THE
PRESSURE WASHER UNTIL GUN
IS TRIGGERED. TO PREVENT
ACCIDENTAL HIGH PRESSURE
DISCHARGE, DO NOT LEAVE
UNIT UNATTENDED WHILE IN
THIS MODE.
OPERATING INSTRUCTIONS
FLUSHING THE SYSTEM:
This unit has a steel coil which, after setting, will cause the water remaining in
the coil from the previous usage to turn brown or black. This water must be
ushed from the system before start-up. This procedure should be performed
without the high pressure hose, gun and dual lance assembly installed.
1. Turn on the water supply.
2. Move the pump switch to the "ON" position. Low pressure water will begin
owing from the water outlet. This allows the unit to ush any particles from
the system. The unit is ushed when the water is clear.
3. Once the system is ushed, move the pump switch to the "OFF" position
and connect the high pressure hose to the water outlet of the unit.
4. Connect the trigger gun and dual lance assembly to the high
pressure hose.
START-UP/COLD WATER OPERATION:
1. Refer to the "Safety Warnings" pgs. 4-7 before starting the unit.
2. Locate the Safety Decals on your unit and heed their warnings.
3. Ensure that the switch is in the "OFF" position.
4. Pointing the trigger gun in a safe direction, unlock the trigger gun and
squeeze the trigger. Brace yourself for possible gun kickback when the
pump starts.
5. Move power switch to the "ON" position.
6. Move the pump switch to the "ON" position.
7. Once the unit has started, perform the following procedures with the gun
open:
a. Inspect for system water leaks, oil leaks and fuel leaks.
If a leak is found, TURN UNIT OFF IMMEDIATELY! Be sure that all
damaged parts are replaced and that the mechanical problems are
corrected prior to operation of the unit. If you require service, contact
Customer Service.
b. Inspect high pressure hoses for kinking, cuts and leaks.
If a cut or leak is found, DO NOT TOUCH HOSE AT LEAK!!! TURN UNIT
OFF IMMEDIATELY! Replace hose before starting the unit. See "Risk
of Injection or Severe Cutting Injury" pg. 6. Be sure that all damaged
parts are replaced and that the mechanical problems are corrected
prior to operation of the unit. If you require service, contact Customer
Service.
8. At this point, the unit is operating as a cold water pressure washer. Trigger
the gun several times and try adjusting the water pressure by rotating the
grip on the dual lance. NEVER place hand or ngers in front of the nozzle
or look directly into the nozzle! High pressure water creates a risk of severe
injury!
9. Do not allow unit to operate in bypass mode (with trigger closed) for more
than ve minutes without triggering the gun. Failure to follow this simple
rule can cause premature failure of pump packings, resulting in costly pump
repair.
NOTE: This unit may be equipped with an Auto Start/Stop feature, the pressure
washer will shutdown if the gun is not triggered after a designated
amount of time. The pressure washer will start again once the gun
is triggered. The Auto Start/Stop feature is preset at the factory for
shutdown at 90 seconds. It can be adjusted by an Authorized Service
Technician to shutdown from no usage after a minimum of 3 seconds
to a maximum of 5 minutes.
10. Your pressure washer can deliver high pressure spray and a variety of
spray patterns using cold water. If you wish to use the Hot Water, Steam
application or Cleaning with Detergents, observe the following procedures.
HOT WATER OPERATION:
1. Follow the steps 1-9 outlined for Start-up / Cold Water Operation.
2. Move the burner switch to the “ON” position and the adjustable thermostat
clockwise to the desired setting.
3. Recheck the system for fuel leaks. If a fuel leak is found, TURN UNIT OFF
IMMEDIATELY! See “Risk of Explosion or Fire”, pg. 5.
NOTE: Upon initial start-up, water will begin turning hot in approximately 20
seconds and will reach maximum temperature in approximately 2-1/2
minutes providing the trigger remains squeezed. The burner will not
re when the trigger is released.
At this point, the unit will operate as a hot water pressure washer. Be extremely
cautious when adjusting the pressure and controlling the trigger gun/dual lance
assembly to avoid the possibility of burns.
WARNING
RISK OF BURN!
THE WATER TEMPERATURE
COULD BECOME VERY HOT
DURING HOT WATER/STEAM
OPERATION. BE CAUTIOUS
WHEN ADJUSTING PRESSURE
OR CONTROLLING THE TRIGGER
GUN/DUAL LANCE ASSEMBLY.
CAUTION
RISK OF UNIT DAMAGE.
BE CERTAIN THE HOSE, GUN
& DUAL LANCE ASSY. ARE
NOT CONNECTED TO THE
UNIT WHILE FLUSHING THE
SYSTEM. FLUSHING ALLOWS
MINERAL DEPOSITS TO BE
RELEASED FROM THE SYSTEM
WHICH WOULD OBSTRUCT
OR DAMAGE THE GUN AND
NOZZLE ASSEMBLY RESULTING
IN COSTLY REPAIRS.
Operator's Manual 15
OPERATING INSTRUCTIONS
WARNING
RISK OF BURN!
THE WATER TEMPERATURE
COULD BECOME VERY HOT
DURING HOT WATER/STEAM
OPERATION. BE CAUTIOUS
WHEN ADJUSTING PRESSURE
OR CONTROLLING THE TRIGGER
GUN/LANCE ASSEMBLY.
TIME DELAY SHUTDOWN OR AUTO START/STOP CHOICE (HHS ONLY):
This unit is equipped with Time Delay Shutdown and Auto Start/Stop. To
switch between Auto Start/Stop and Time Delay Shutdown, see below.
BLK / 104
From Wiring Diagram
Time Delay Shutdown
Auto Start/Stop
250° STEAM OPTION (HX-0172, HX-0174 AND HX-0176):
1. Install Steam Nozzle.
2. Follow steps 1-9 of Start-up / Cold-Water Operation.
3. Recheck the system for water leaks and fuel leaks. If a leak is found, TURN
UNIT OFF IMMEDIATELY!
4. Turn adjustable thermostat clockwise to maximum setting. If a lower
thermostat setting is desired, it is normal for the burner to cycle (re
intermittently) while spraying. (Note: Adjustable thermostat is a high limit
device and does not regulate temperature.)
NOTE: Upon initial start-up, water will begin turning hot in approximately 20
seconds and will reach steam temperature in approximately 5 minutes
providing the trigger remains squeezed. The burner will not re when
the trigger is released.
At this point, the unit will operate as a steam pressure washer. Be extremely
cautious when adjusting the pressure and controlling the trigger gun/dual lance
assembly to avoid the possibility of burns.
OPTIONAL STEAM OPERATION (HHS ONLY):
16 Operator's Manual
CLEANING WITH DETERGENTS:
NOTE: This feature is designed for use with mild detergents only. Since the
cleaning solution travels through various parts of the pressure washer,
do not use corrosives as they will cause extensive damage as well as
pose a considerable safety hazard.
1. Refer to "Risk of Bodily Injury/Detergents" pg. 7. Be certain to wear protective
safety attire as stated on pg. 10.
2. Prepare detergent solution according to label directions. (Never pump acids,
alkalines, abrasive uids or solvents through the unit. Due to the unknown
and often corrosive characteristics of many detergents commonly used in
the pressure washer cleaning industry, it is recommended to use only mild
detergents with this unit.)
3. Fully immerse the strainer end of the clear vinyl detergent hose into the
detergent solution.
4. Adjust the amount of detergent desired by turning the detergent metering
valve [shown at right] completely counterclockwise to set at maximum siphon
rate.
5. To apply solution; unlock the trigger gun and squeeze the trigger. In a few
moments a detergent/water mixture will exit the nozzle. Start spraying the
lower portion of the surface being cleaned and move up, using long overlapping
strokes. Applying from the bottom up helps avoid streaking. Allow to soak
briey. Avoid working on hot surfaces or in direct sunlight to minimize the
chances of the detergent drying, which may result in damaging surfaces.
Be certain to apply cleaning solution to a small section at a time.
6. To rinse; lock the trigger gun in the "OFF" position. Turn the detergent
metering valve to the "OFF" position. Unlock the trigger gun and spray. It
will take about 30 seconds to purge all detergent from the line. For best
rinsing results, start at the top and work down.
7. Siphon a gallon of water through the detergent injection system after each
use. This prevents the possibility of corrosion or detergent residue causing
mechanical problems during the next use.
OPERATING INSTRUCTIONS
--- HHB-303-0E1A MACHINES ONLY -- NOT CSA APPROVED
MACHINE!! ---
STEAM OPERATION:
1. Follow steps 1-7 of Start-up / Cold-Water Operation.
2. Move switch to burner position.
3. Recheck the system for water leaks and fuel leaks. If a leak is found,
TURN UNIT OFF IMMEDIATELY! See "Risk of Explosion or Fire, pg.
5)
NOTE: Upon initial start-up, water will begin turning hot in approximately
20 seconds and will reach steam temperature in approximately 5
minutes providing the trigger remains squeezed. The burner will
not re when the trigger is released.
At this point, the unit will operate as a steam pressure washer. Be extremely
cautious when adjusting the pressure and controlling the trigger gun/dual
lance assembly to avoid the possibility of burns.
Operator's Manual 17
DANGER
RISK OF INJECTION CAUSING
SEVERE INJURY!
-AUTO START/STOP FEATURE
WILL SHUTDOWN THE PRESSURE
WASHER UNTIL THE GUN IS
TRIGGERED. TOTAL SHUTDOWN
REQUIRES ALL THE SWITCHES
TO BE MOVED TO THE OFF
POSITION.
-TO PREVENT ACCIDENTAL HIGH
PRESSURE DISCHARGE, DO NOT
LEAVE UNIT UNATTENDED UNTIL
ALL THE SWITCHES ARE IN THE
OFF POSITION.
OPERATING INSTRUCTIONS
SHUTDOWN:
1. Move the burner switch to the "OFF" position. Pump will remain on.
2. Squeeze the trigger and discharge the water for a period of three minutes
to cool the heat exchanger and high pressure hose. (Insufcient cool
down period of the high pressure hose will cause excessive wear and
eventual rupturing of the hose.)
3. Move the switch to the "OFF" position. (Auto Start/Stop Option will shut
the unit down, but total shutdown requires switch to be moved to the
"OFF" position.)
4. Move power switch to "OFF" position for complete shutdown.
5. Turn off the water supply and trigger the gun momentarily to relieve
trapped pressure.
6. Disconnect and drain the high pressure hose, gun, and dual lance. Wipe
the unit clean store in a non-freezing environment.
STEAM - 250°F (HX-0172/HX-0174/HX-0176):
The 250°F steam option provides wet steam output from the unit. Using the
included steam nozzle, 250°F steam is obtained. The sizing of the steam
nozzle is critical to proper operation of the option.
OPTIONS (HHS ONLY):
18 Operator's Manual
MAINTENANCE CHART
PROCEDURE DAILY 3 MONTHS 6 MONTHS 9 MONTHS 12 MONTHS
Inspect electrical cord X
Test GFCI (according to instructions
on GFCI).
X
Check water pump oil level X
Oil leak visual inspection X
Fuel leak visual inspection X
Water leak visual inspection X
Hose visual inspection X
Water strainer inspection X
High pressure nozzle inspection X
Fuel lter/water sep. inspection X
Change water pump oil ** X X X X
Replace high pressure nozzle*** X X X X
Inspect belt X X X X
Check burner air adjustment X X X X
Test water pressure* X X X X
Test water temperature* X X X X
Replace fuel lter X X
Test fuel pressure* X
Delime coil**** X
Test voltage and amp draw* X
Inspect fuel pump lter* X
Check burner electrodes* X
Replace fuel nozzle* X
* Should be performed by an authorized service technician.
** The pump oil must be changed after the rst 50 hours of operation and every 500 hours or 3 months, whichever
comes rst.
*** High pressure nozzle should be replaced whenever pressure is less than 85%.
**** Scale build up will vary with mineral content in the water and amount of usage. Deliming can range from weekly
to yearly maintenance.
STORAGE & MAINTENANCE
Operator's Manual 19
STORAGE & MAINTENANCE
MAINTENANCE-DAILY:
INSPECT ELECTRICAL CORD: Detach unit from power source and
inspect electrical cords to ensure they are free of cuts. If a cut is
found, replace cord before operating unit.
TEST GFCI: If applicable, test the GFCI. Testing varies according to
the specic GFCI. Follow the instructions given on the GFCI for
correct procedures.
CHECK WATER PUMP OIL LEVEL: Make certain the oil is on the "FULL"
mark on the dipstick or in the center of the oil sight glass. If the oil
appears to be low, ll with SAE20 or 30 non-detergent pump oil.
OIL LEAK INSPECTION: If a leak is found, promptly eliminate any
leaks found in the pumping system. Be sure that all damaged parts
are replaced and that the mechanical problems are corrected prior
to operation of the unit. If you require service, contact Customer
Service.
FUEL LEAK INSPECTION: If a fuel leak is found, turn unit off immediately!
See "Risk of Explosion or Fire", pg. 5. Be sure that all damaged parts
are replaced and that the mechanical problems are corrected prior
to operation of the unit. If you require service, contact Customer
Service.
WATER LEAK INSPECTION: If a leak is found, promptly eliminate any
leaks found in the pumping system by removing suspect parts, applying
thread sealant to the threads and reinstalling. If using teon tape, be
certain no tape gets inside any plumbing to prevent the possibility of
a plugged spray nozzle. Be sure that all damaged parts are replaced
and that the mechanical problems are corrected prior to operation of
the unit. If you require service, contact Customer Service.
HOSE INSPECTION: Inspect high pressure hoses for kinking, cuts
and leaks. If a cut or leak is found, DO NOT USE HOSE! Replace
hose before starting unit. See "Risk of Injection or Severe Cutting
Injury", pg. 6. Be sure that all damaged parts are replaced and that
the mechanical problems are corrected prior to operation of the unit.
If you require service, contact Customer Service.
WATER STRAINER INSPECTION: Ensure the water strainers (A) are
clean and free of any obstructions. Periodic cleaning of the water
strainer will help prevent pump problems. As a strainer becomes
obstructed, it restricts proper ow of water to the pump. This can result
in cavitation which will cause premature failure of pump packings.
Remove strainer screens (A), clean or replace.
QUICK COUPLERS INSPECTION: There are o-ring seals inside the
couplers which will deteriorate. To replace, simply install a replacement
o-ring to correct the leak. (Additional o-rings can be purchased from
your dealer.)
HIGH PRESSURE NOZZLE: Inspect high pressure nozzle for wear or
obstructions. Clean or replace if necessary.
FUEL FILTER/WATER SEPARATOR: Inspect bowl on fuel lter/water
separator for water accumulation. If water exists, unscrew drain
valve on bowl to drain water, then close.
A
A
20 Operator's Manual
MAINTENANCE-EVERY 3 MONTHS:
CHANGE WATER PUMP OIL: Ensure unit is off and unplugged. Change
the pump oil after the rst 50 hours of operation. After initial change,
every 3 months or 500 hour intervals are recommended. If oil appears
dirty or milky, changes may be required in greater frequency. Use
SAE20 or 30 non-detergent pump oil and ll only to the center of the
oil sight glass. DO NOT overll.
REPLACE HIGH PRESSURE NOZZLE: Water ow through the spray
nozzle will erode the orice, making it larger, resulting in a pressure
loss. Nozzles should be replaced whenever pressure is less than
85% of the maximum. The frequency of replacement will depend
upon such variables as mineral content in the water and number of
hours the nozzle is used.
BELT INSPECTION: Ensure unit is off and unplugged. Open the access
panel by unscrewing the two side knobs that secure the panel in place.
Slide the motor/pump assembly out. Inspect the v-belt for wear and
tightness. If the v-belt needs to be replaced or tightened, follow the
procedures listed below.
Replacement:
1. Loosen the four pump mounting bolts (A).
2. Loosen the two alignment nuts approximately one inch on the
alignment bolts (B1 & B2).
3. Slide the pump toward the motor to loosen belts.
4. Remove and replace belt.
Tighten: (If v-belt was not replaced, you will need to loosen the nuts
on the alignment bolts B1 and B2 before proceeding.)
1. Tighten B2 alignment bolt. The pump will shift to the left until
there is tension on the belt. Then tighten B2 nut.
2. Tighten B1 alignment bolt, until sheaves are straight. (Use a
straightedge for alignment.)
3. Push on the v-belt to check belt deection for tension. There
should be 1/4" to 1/2" deection for correct tension.
4. If sheaves are straight and tension is correct, tighten B1 nut and
the four pump mounting bolts (A).
5. If tension is not correct, repeat steps 6 and 7 until correct alignment
and tension is achieved. Tighten the four mounting bolts (A) when
completed.
6. Loosen B2 nut, tighten B2 bolt, tighten B2 nut.
7. Loosen B1 nut, tighten B1 bolt, tighten B1 nut.
BURNER AIR ADJUSTMENT: The air shutter has been factory preset for
proper operation between sea level and 2000 feet elevation at standard
conditions (60°F ambient water and air temperatures). In colder
temperatures or higher altitudes, it may be necessary to adjust the
air supply to the combustion chamber. This adjustment will maximize
burner efciency and avoid inefcient operation or excessive sooting
of the heat exchanger coil. A smoke spot test is recommended during
any air shutter and band adjustment. If you do not have the equipment
to perform a smoke spot test, follow the procedures listed below.
1. The machine must be running and the burner ON.
2. Loosen the Locking Screw (#3 at left) on the shutter.
3. Check for smoke from the heat exchanger exhaust. If smoke is
not present, slowly close the Air Shutter (#1 at left) by moving the
dial counterclockwise to a lower number. Continue moving the
dial until smoke appears.
4. Record this setting.
5. Open Air Shutter (#1 at left) two increments. Example: If Air
Shutter was set at 2, move it to 4.
6. Slowly trigger the gun on and off. This will cause the burner to
turn on and off. Look for a smoke puff when the burner ignites.
7. Repeat steps 5 and 6 until a smoke puff is noticed. Record the
Air Shutter Setting.
8. The difference between the recorded settings in steps 4 and 7
is the combustion window. Set the dial 1/2 way between these
settings.
NOTE: If you are unable to detect a setting on either step 3 or 7, more or less
air may be needed to achieve a proper combustion window. Loosen
the Bolt (#4 at left) and open the Air Band (#2 at left) in 1/4" increments.
Repeat steps 3-8 until proper combustion window is achieved.
TEST WATER & FUEL PRESSURE: These procedures should be
performed by an authorized service technician.
TEST WATER TEMPERATURE: This procedure should be performed by
an authorized service technician.
STORAGE & MAINTENANCE
Operator's Manual 21
MAINTENANCE-EVERY 6 MONTHS:
REPLACE FUEL FILTER: Follow the instructions specied on the fuel lter
for correct procedures.
MAINTENANCE-EVERY 12 MONTHS:
DELIME COIL: A loss in pressure may signify that the coil needs to be
delimed. Do this procedure on a periodic basis.
1. Mix non-caustic deliming powder/solution in oat tank according to
package directions.
2. Remove the nozzle from the wand. Place a nylon stocking over the
wand assembly to collect debris, then place the wand assembly into
the oat tank.
3. Turn the switch to the "Pump" position. Water will circulate throughout
the system and back into the oat tank. Allow circulation to continue
for 2-4 hours.
4. Turn the switch to the "Off" position. Drain and clean the oat tank.
Remove nylon stocking and clean wand assembly.
5. Flush the entire system with clean, fresh water, then replace nozzle
into wand assembly.
6. Dispose of deliming solution according to local, state and national
regulations.
TEST VOLTAGE & AMP DRAW: Use a volt meter and amp meter to test
the machine for correct voltage and amperage. If you do not have these
instruments or do not know how to use them, this procedure should be
performed by an authorized service technician.
INSPECT FUEL PUMP INTERNAL FILTER: This procedure should be
performed by an authorized service technician.
CHECK BURNER ELECTRODES: This procedure should be performed
by an authorized service technician.
REPLACE FUEL NOZZLE: This procedure should be performed by an
authorized service technician.
CLEAN FUEL PICKUP INLET SCREEN: This procedure should be performed
by an authorized service technician.
MAINTENANCE-SEASONAL:
WINTERIZING: For storage and transportation purposes in subfreezing ambient
temperatures, it will be necessary to winterize this unit. This unit must be
protected to the lowest incurred temperature for the following reasons:
1. If any part of the pumping system becomes frozen; excessive pressure
may build up in the unit which could cause the unit to burst resulting in
possible serious injury to the operator or bystanders.
2. The pumping system in this unit may be permanently damaged if frozen.
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below
32°F, you can protect your unit by following one of the procedures listed
below.
AIR BLOWOUT:
1. Remove the nozzle from the wand assembly. Squeeze the trigger until
water ceases to exit the wand assembly.
2. Connect an air tting from an air hose to the strainer tting in the oat
tank.
3. Run compressed air into the system to remove all water from the
system.
ANTIFREEZE SOLUTION:
1. Pour a 50/50 mixture of antifreeze and water into the oat tank.
2. Place the detergent strainer into 100% antifreeze solution
3. Turn the switch to the "Pump" position. Allow antifreeze to siphon
throughout the system until antifreeze solution exits the outlet. (To
ensure the coil is winterized, antifreeze solution must exit the outlet.
Add more 50/50 mixture to the oat tank if necessary.)
STORAGE & MAINTENANCE
WARNING
RISK OF UNIT BURSTING.
DO NOT STORE / OPERATE
UNIT IN A FREEZING
ENVIRONMENT!
32˚F 0˚C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Mi-T-M HHB Series Owner's manual

Category
High-pressure cleaners
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI