Tripp Lite AG-0044 Owner's manual

Category
Power distribution units (PDUs)
Type
Owner's manual
1
Warranty
Registration:
register online today for a
chance to win a FREE Tripp Lite
product—www.tripplite.com/warranty
Owner’s Manual
Single-Phase 0U Switched
Power Distribution Units with
Individual Outlet Current Metering
PDUMVR20NET • PDUMVR30NET • PDUMVR30HVNET
(AG-0044) (AG-0045) (AG-0046)
Important Safety Instructions 2
Installation 3
Digital Load Meter 8
Features 9
Configuration and Operation 11
Service 11
Warranty and Warranty Registration 12
Español 13
Français 25
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2013 Tripp Lite. All rights reserved.
13-02-027-933161-revB.indb 1 2/7/2013 1:19:07 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during
the installation, operation, and storage of this product. Failure to heed these
instructions and warnings may affect the product warranty.
• Provideadequateprotectionagainstexcesscurrents,shortcircuitsandgroundfaultsin
accordancewithlocalandnationalelectricalcodes,suchasNECintheU.S.
• ThemainssocketoutletthatsuppliesthePDUshouldbenearthePDUandeasilyaccessible.
• OperatethePDUatindoortemperaturesbetween32°Fand104°F(between0°Cand40°C)
only.
• Neverattempttoinstallelectricalequipmentduringathunderstorm
•ThePDUprovidesconvenientmultipleoutlets,butitDOESNOTprovidesurgeorlinenoise
protectionforconnectedequipment.
•ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfromexcess
moisture,temperatureextremes,conductivecontaminants,dustordirectsunlight.
•DonotconnectthePDUtoanungroundedoutletortoextensioncordsoradaptersthat
eliminate the connection to ground.
•ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmustnotexceed
the individual outlet’s load rating.
•ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceedthe
maximumloadratingforthePDU.
•DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-serviceable
parts inside.
•DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
•DonotattempttousethePDUifanypartofitbecomesdamaged.
•DonotattempttomountthePDUtoaninsecureorunstablesurface.
•Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentortosignicantly
affectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthe
presenceofaammableanestheticmixturewithair,oxygenornitrousoxide.
13-02-027-933161-revB.indb 2 2/7/2013 1:19:07 PM
1-2
1-1
1-3 1-4
3
Installation
Mounting the PDU
Note: The illustrations may differ somewhat from your PDU model. Regardless of configuration, the user must
determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed
for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting
configurations may vary. Screws for attaching the mounting brackets and cord retention shelf to the PDU are
included. Use only the screws supplied by the manufacturer, or their exact equivalent.
IfinstallingthePDUinarackthathasbutton-mountslots,youonlyneedtoperformstepsfor
toollessmounting(step
1-1
).Ifyourrackdoesnothavebutton-mountslots,proceedtostep
1-2
.
Toolless Mounting
1-1
 Attachtheincludedmountingbuttons
tothePDU.PositionthePDUasdesired
intherackenclosure,alignthebuttons
withtherackmountingslots,andslide
thePDUintoposition.
Note: To install the PDU with its outlets facing the rear
of the rack, use the included PDUMVROTATEBRKT
accessory. This V-shaped bracket provides a mounting
button on one leg of the V and a button- mount slot on
the other, effectively repositioning the mounting buttons.
See Features section for image.
Regular Mounting
1-2
 Attachthemountingbracketstothe
PDU.
1-3
 (Optional)Attachthecordretention
bracket(s)tothePDU.
1-4
 AttachthePDUtoaverticalrailin
yourrackorrackenclosure.(Usethe
mounting hardware that came with your
rackorrackenclosuretoattachthe
mountingbracketstotherail.)
PDUMVR30HVNETShown
13-02-027-933161-revB.indb 3 2/7/2013 1:19:11 PM
A
4
Connecting the PDU
2-1
Connect the input plug to your facility’s
compatibleACpowersource.
2-2
 Allmodelscontain2banksofoutput
receptacles.
• PDUMVR20NETandPDUMVR30NET
contain2banksof125-15/20R
receptacles(24total).
• PDUMVR30HVNETcontains2banks
of 10 C13 and 2 C19 receptacles
(24total).
Connectyourequipment’sinputplugs
totheappropriateoutletsonthePDU.
OntheSwitchedmodels,theLEDnear
each outlet illuminates when the outlet
isreadytodistributeliveACpower.
Note: It is recommended that you do not
connect a live load to the PDU. If the load
you intend to connect has an ON/OFF
switch, please turn the switch to OFF prior to
connection.
2-3
 (Optional)Ifyouattachedthecord
retentionbracket(s),tieeachequipment
powercordtotheretentionbracket.
Attach each cord to the retention shelf
byloopingthecordandsecuringitwith
oneoftheincludedcableties
A
.Make
sureeachcordcanbeunpluggedfrom
thePDUwithoutremovingthecabletie.
Installation
Networking the PDU
Note: The MAC address of the PDU (a 12-digit string in this format: 000667xxxxxx) is printed on a label
attached to the PDU enclosure.
Ifyournetwork’sDHCPserverwillassignadynamicIPaddresstothePDUautomatically,go
toStep
3-1
.IfyouwillassignastaticIPaddresstothePDUmanually,gotoStep
4-1
. If you
areuncertainwhichmethodtouse,contactyournetworkadministratorforassistancebefore
continuing the installation process.
Dynamic IP Address Assignment
3-1
Connect PDU to Network: While the
PDUispowered,connectastandard
EthernetpatchcabletotheRJ-45
EthernetportonthePDU.
Note: This port is not compatible with PoE
(Power over Ethernet) applications. The PDU
will attempt to obtain an IP address via DHCP.
This may take as long as several minutes,
depending on your network environment.
SomeModelsWillVary.
PDUMVR30HVNETShown
PDUMVR30HVNETShown
13-02-027-933161-revB.indb 4 2/7/2013 1:19:13 PM
242322212019181716151413
CONFIGACCY
STATUS
LINK
RESET
ENVIROSENSE
121110987654321
5
Installation
Dynamic IP Address Assignment
3-2
Discover IP Address: ContactyournetworkadministratortodeterminewhichdynamicIP
addresshasbeenassignedtothePDUbytheDHCPserver.ThePDUcanbeidentiedon
theDHCPserverbyreferringtoitsMACaddress.(TheMACaddressisa12-digitstringin
thisformat:000667xxxxxx.RefertotheMACaddresslabelattachedtothePDU.)Youmay
wishtorequestalong-termleaseperiodfortheIPaddress,dependingonyourapplication.
AfteryouhavediscoveredtheIPaddress,skipSteps
4-1
through
4-6
and proceed directly
toStep
5-1
.
3-3
Alternate Method:PressandholdtheSelectOutletbuttonontheDigitalLoadMeter
(seepage8)for4secondstodisplaytheIPaddress.Thedefaultisnoaddressassigned.
Ifthisisthecase,“noaddress”willdisplayoneletteratatime.IfthereisanIPAddress
programmed,theaddresswilldisplay1digitatatimewithdashes(-)representingdotsor
periods(.).
Static IP Address Assignment
4-1
Determine IP Information:BeforeassigningastaticIPaddress,you’llneedtoknowthe
IPaddress,gatewayaddressandsubnetmask.Ifyoudonothavethisinformation,contact
yournetworkadministratorforassistance.
4-2
Congure Terminal Emulation Program: OpenaVT100-compatibleterminalemulation
program(suchastheHyperTerminalprogrambundledwithMicrosoft
®
Windows
®
)on
acomputerwithanavailableDB9serialport.(Anotebookcomputermaybethemost
convenientchoice.)SettheterminalemulationprogramtousetheCOMportthat
correspondstothecomputer’sDB9serialport.Specifytheparametersrequiredto
communicatewiththePDUterminalinterface:
Bitspersecond: 9600 Stopbits: 1
Databits: 8 FlowControl: None
Parity: None
Iftheterminalemulationprogramsupportsmultipleemulationmodes,youmayalsoneed
tospecifyVT100emulation.
4-3
Connect PDU to Computer: Use
theRJ-45toDB9congurationcable
(partnumber73-1243)includedwith
thePDUtoconnectthePDUtothe
computer. The connector at one end of
thecableattachestotheCONFIGRJ-45
portonthePDU.TheDB9connectorat
theotherendofthecableconnectsto
the computer’s serial port.
4-4
Press SNMP Reset Button: Usinga
smalltoolorpaperclip,pressthereset
buttonfor3secondstorebootthe
PDU’snetworkcard.Rebootingthe
networkcardwillnoterasenetwork
settings or interrupt AC power.
13-02-027-933161-revB.indb 5 2/7/2013 1:19:14 PM
6
Installation
Static IP Address Assignment
4-5
Congure PDU in Terminal Mode: Afterabriefpause,aninitializationpageshould
appearintheterminalemulationprogram.Pressanykeyonthekeyboardwithin5seconds
tochangethePDUsettings.
Note: If the 5-second period has elapsed, you can reboot the PDU by:
1. Using a small tool or paper clip to press the recessed Reset button on the PDU for 3 seconds.
2. Pressing any key during, or after, the boot process. This will prompt for a login name and password.
The default user name and password for this process are both “localadmin.” After logging in, type
“reboot” to initiate the card reboot.
Press A to Accept the settings, or M to Modify? M
Enter the root password: *********
Reset configuration and root password to default values. (Y/N)? N
Network Settings
FollowthepromptstocongureIPv4andIPv6addresssettings.Thedefaultterminalmode
passwordisTrippLite.SampleIPsettingsareshown—supplyyourownIPinformationwhenyou
congureyourcard.
ETHERNET INTERFACE SETTINGS:
Obtain IPv4 settings automatically using DHCP for Ethernet interface? [Y]
IP address? [10.1.0.165]
Subnet mask? [255.0.0.0]
Gateway address? [10.0.0.1]
Enable DHCPv6 for the Ethernet interface? [Y]
Enable static IPv6 for the Ethernet interface? [N]
IPv6 address? [2001:DB8::1:58:4F43:4849:544C]
Network prefix length? [64]
DNS server? [10.0.0.8]
This card’s host name? [poweralert-061033462177]
This card’s domain? [tlsoftwaredev.local]
13-02-027-933161-revB.indb 6 2/7/2013 1:19:14 PM
A
B
7
Installation
Network Connection
5-1
Connect PDU to Network: While the
PDUispowered,connectastandard
EthernetpatchcabletotheRJ-45
EthernetportonthePDU.
Note: This port is not compatible with PoE
(Power over Ethernet) applications.
5-2
Access PDU with Web Browser: After
anIPaddresshasbeenassignedto
thePDU,attempttoaccessitwitha
Webbrowserthatsupportsframes,
formsandJava™.OpenaWebbrowser
onacomputerconnectedtotheLAN
andentertheIPaddressassigned
tothePDU.Youshouldbeprompted
for a password
A
. The user name is
“localadmin”andthedefaultpassword
is“localadmin”.Afteryouentertheuser
nameandpassword,thePowerAlert
status page
B
will appear in the
browserwindow.Formoreinformation
aboutcongurationandoperationofthe
PDUviathePowerAlertinterface,refer
totheSNMPWEBCARDUser’sGuide,
includedontheCD-ROMbundledwith
thePDU.
Note for Network Management System
Users Only: Two MIB files - Tripplite.mib
and RFC1628.mib - must be loaded on
each Network Management Station that
will monitor the PDU via SNMP. The files are
provided on the CD-ROM included in the
product package.
Enable SNTP? [Y]
Enable FTP? [Y]
Port number? [21]
Enable HTTP? [Y]
Port number? [80]
Enable HTTPS? [Y]
Port number? [443]
Enable Telnet Menu? [Y]
Port number? [23]
Enable Telnet Programs? [Y]
Port number? [5214]
Enable SSH Menu? [Y]
Port number? [22]
Enable SSH Programs? [Y]
Port number? [2112]
Enable SNMP? [Y]
Port number? [161]
Enable SNMPv1? [Y]
Enable SNMPv2c? [Y]
Enable SNMPv3? [Y]
Youcanalsochangetherootpassword,real-timeclockandothersettings.(TrippLite
recommends against changing the default settings unless you are an advanced user with a
specicpurpose.)Afteryouhavenishedenteringsettings,thePDUwillsavechangestomemory
andreboot(thismaytakeseveralminutes).AfterthePDUreboots,theinitializationpageshould
displaythenewstaticIPsettings.
4-6
Remove Serial Cable:RemovetheserialcablefromthePDUandproceedtoStep
5-1
.
Network Service Configuration
ThefollowingpromptsconguretheconnectionmethodsthattheSNMPWEBCARDwillaccept.
13-02-027-933161-revB.indb 7 2/7/2013 1:19:15 PM
UP
DOWN
A
E
B
C
D
8
Digital Load Meter
1
Select Bank Button:Thisbutton
A
canbepressedtoshowtotalcurrentfor
eachbank.Pressingthisbuttononce
will display the total current for all of the
Bank1outlets,locatednearesttothe
inputcord.TheLEDforBank1
D
will
illuminateandthetotalcurrentforBank
1outletswilldisplayinampsintheLED
Amps display
C
.Pressingthisbutton
A
a second time will produce the same
resultsforBank2.Pressingthebuttona
thirdtimewilldisplaytotalPDUcurrent
andbothBank1andBank2LEDswill
light.Pressingthebuttonadditional
times will repeat the cycle.
Ifyoupressandholdthisbuttonfor
4seconds,thenumbersintheLED
Amps display
C
will flip for mounting
versatility.Theunitcanbemountedwith
thepowercordfacingthetoporbottom
whilestillbeingabletoreadthedisplay.
2
Select Outlet Button: Thisbutton
B
canbepressedtoshowthecurrentforeach
individualoutlet.TheLEDlocatednexttotheselectedoutletandtheLEDfortheBank
towhichtheoutletbelongs(
D
or
E
)willashwhenthetotalcurrentforthatoutletis
displayed(inamps)ontheLoadMeterDisplay
C
.
Pressingthisbuttonasecondtimewillproducethesameresultsforoutlet2,pressinga
third time for outlet 3 and so on through all the outlets.
Ifyoupressandholdthisbutton
B
for4secondsyoucandisplaytheIPAddressassigned
totheunitintheLEDAmpsdisplay
C
. The default is no address assigned. If this is the
case,“no address”willdisplay,oneletteratatime.IfthereisanIPAddressprogrammed,
theaddresswilldisplay1digitatatimewithdashes(-)representingdotsorperiods(.).
13-02-027-933161-revB.indb 8 2/7/2013 1:19:16 PM
9
Features
Outlets: Duringnormaloperation,theoutletsdistributeACpowerto
connectedequipment.
Outlet LED: Oncetheunitispowered-on,eachoutletindividuallyramps
upandeachoutletLEDwillilluminatewhentheassociatedoutletisready
todistributeliveACpower.
IEC-60320-C13
IEC-60320-C19 5-15/20R
Circuit Breaker (select models): Eachbankhasitsownbreakerlabeled
Bank1andBank2.Iftheconnectedequipmentloadexceedsthe
MaximumLoadRatingforthatbankofthePDU,thecircuitbreakerwill
trip.
Circuit Breaker (Select Models): Iftheconnectedequipmentload
exceedstheMaximumLoadRatingofthePDU,thecircuitbreakerwill
trip.Disconnectexcessequipmentandallowthebreakertocoolbefore
depressingtheplungertoresetthebreaker.
Cord Retention Bracket:Providessecureattachmentpointsfor
connectedequipmentcords.
Mounting Buttons:Comepre-installedonthebacksideofthePDUand
are used for toolless mounting. Note: Four additional mounting buttons
are included for alternate rack styles.
PDUMVROTATEBRKT Mounting Accessory: UsetheseV-shaped
bracketstomountthePDUwithitsoutletsfacingtherearoftherack.
Ground Screw: Usethistoconnectanyequipmentthatrequiresa
chassis ground.
13-02-027-933161-revB.indb 9 2/7/2013 1:19:18 PM
CONFIG
A B
ACCY
10
RJ-45 Conguration Port: Usethisporttoprovideadirectterminal
connectiontoacomputerwithaterminalemulationprogram.AnRJ-45
cableisincludedwiththePDU.Ifyouneedareplacementcable,visit
www.tripplite.com for ordering information.
RJ-45 ACCY Port: Reserved for future use.
Ethernet Port: UsethisRJ-45jacktoconnectthePDUtothenetwork
withastandardEthernetpatchcable.TheLinkLED
A
andStatusLED
B
indicateseveraloperatingconditions,asshowninthetablebelow.This
port is not compatible with PoE (Power Over Ethernet) applications.
NetworkOperatingConditions
A
Link LED Color
Off NoNetworkConnection
FlashingAmber 100MbpsNetworkConnection
FlashingGreen 10MbpsNetworkConnection
B
Status LED Color
Off CardNotInitialized
SteadyorFlashingGreen CardInitializedandOperational
SteadyAmber Error-CardNotInitialized
Features
Mounting Brackets: UsethesebracketstomountthePDU.
SNMP Reset Button: Presstheresetbuttonwithasmalltoolorpaper
clipfor3secondstorebootthePDU’snetworkcard.Rebootingthe
networkcardwillnoterasenetworksettingsorinterruptACpower.
PS/2 Port: UsethisporttoconnectaTrippLiteENVIROSENSE
environmental sensor to provide remote temperature/humidity monitoring
andadrycontactinterfacetocontrolandmonitoralarm,securityand
telecomdevices.Visitwww.tripplite.comfororderinginformation.Note:
Do not connect a keyboard or mouse to this port.
13-02-027-933161-revB.indb 10 2/7/2013 1:19:20 PM
A
B
11
Configuration and Operation
Service
Remote Monitoring and Control
ThePDUprovidesremotemonitoring
A
,
outlet control
B
andmoreviaWebbrowser,
telnetandSNMP-basedNetworkManagement
Systems.Formoreinformationabout
congurationandoperationofthePDUvia
thePowerAlertWebbrowserinterface,referto
theSNMPWEBCARDUser’sGuide,includedon
theCD-ROMbundledwiththePDU.
YourTrippLiteproductiscoveredbythewarrantydescribedinthismanual.AvarietyofExtended
WarrantyandOn-SiteServiceProgramsarealsoavailablefromTrippLite.Formoreinformation
onservice,visitwww.tripplite.com/support.Beforereturningyourproductforservice,followthese
steps:
1. Review the installation and operation procedures in this manual to insure that the service
problemdoesnotoriginatefromamisreadingoftheinstructions.
2. Iftheproblemcontinues,donotcontactorreturntheproducttothedealer.Instead,visit
www.tripplite.com/support.
3. Iftheproblemrequiresservice,visitwww.tripplite.com/supportandclicktheProduct
Returnslink.FromhereyoucanrequestaReturnedMaterialAuthorization(RMA)number,
whichisrequiredforservice.Thissimpleon-lineformwillaskforyourunit’smodeland
serialnumbers,alongwithothergeneralpurchaserinformation.TheRMAnumber,along
withshippinginstructionswillbeemailedtoyou.Anydamages(direct,indirect,special
orconsequential)totheproductincurredduringshipmenttoTrippLiteoranauthorized
TrippLiteservicecenterisnotcoveredunderwarranty.ProductsshippedtoTrippLiteoran
authorizedTrippLiteservicecentermusthavetransportationchargesprepaid.MarktheRMA
numberontheoutsideofthepackage.Iftheproductiswithinitswarrantyperiod,enclose
a copy of your sales receipt. Return the product for service using an insured carrier to the
addressgiventoyouwhenyourequesttheRMA.
13-02-027-933161-revB.indb 11 2/7/2013 1:19:20 PM
12
Warranty and Warranty Registration
2- YEAR LIMITED WARRANTY
Sellerwarrantsthisproduct,ifusedinaccordancewithallapplicableinstructions,tobefreefromoriginaldefects
inmaterialandworkmanshipforaperiodof2yearsfromthedateofinitialpurchase.Iftheproductshould
provedefectiveinmaterialorworkmanshipwithinthatperiod,Sellerwillrepairorreplacetheproduct,initssole
discretion.ServiceunderthisWarrantycanonlybeobtainedbyyourdeliveringorshippingtheproduct(withall
shippingordeliverychargesprepaid)to:TrippLite,1111W.35thStreet,Chicago,IL60609USA.Sellerwillpay
returnshippingcharges.Visitwww.tripplite.com/supportbeforesendinganyequipmentbackforrepair.
THISWARRANTYDOESNOTAPPLYTONORMALWEARORTODAMAGERESULTINGFROMACCIDENT,MISUSE,
ABUSEORNEGLECT.SELLERMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYEXPRESSLY
SETFORTHHEREIN.EXCEPTTOTHEEXTENTPROHIBITEDBYAPPLICABLELAW,ALLIMPLIEDWARRANTIES,
INCLUDINGALLWARRANTIESOFMERCHANTABILITYORFITNESS,ARELIMITEDINDURATIONTOTHE
WARRANTYPERIODSETFORTHABOVE;ANDTHISWARRANTYEXPRESSLYEXCLUDESALLINCIDENTALAND
CONSEQUENTIALDAMAGES.(Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,
andsomestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sotheabove
limitationsorexclusionsmaynotapplytoyou.ThisWarrantygivesyouspeciclegalrights,andyoumayhave
otherrightswhichvaryfromjurisdictiontojurisdiction).
WARNING:Theindividualusershouldtakecaretodeterminepriortousewhetherthisdeviceissuitable,adequate
orsafefortheuseintended.Sinceindividualapplicationsaresubjecttogreatvariation,themanufacturermakes
norepresentationorwarrantyastothesuitabilityortnessofthesedevicesforanyspecicapplication.
WARRANTY REGISTRATION
Visitwww.tripplite.com/warrantytodaytoregisterthewarrantyforyournewTrippLiteproduct.You’llbe
automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*
*Nopurchasenecessary.Voidwhereprohibited.Somerestrictionsapply.Seewebsitefordetails.
FCC Notice, Class A
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)
Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,
including interference that may cause undesired operation.
Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuant
topart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful
interferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,uses,
andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstruction
manual,maycauseharmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidential
areaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterference
athisownexpense.Theusermustuseshieldedcablesandconnectorswiththisequipment.Anychangesor
modicationstothisequipmentnotexpresslyapprovedby
TrippLitecouldvoidtheuser’sauthoritytooperatethisequipment.
Regulatory Compliance Identication Numbers
Forthepurposeofregulatorycompliancecerticationsandidentication,yourTrippLiteproducthasbeenassigned
auniqueseriesnumber.Theseriesnumbercanbefoundontheproductnameplatelabel,alongwithallrequired
approvalmarkingsandinformation.Whenrequestingcomplianceinformationforthisproduct,alwaysrefertothe
seriesnumber.Theseriesnumbershouldnotbeconfusedwiththemarkingnameormodelnumberoftheproduct.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
UndertheWasteElectricalandElectronicEquipment(WEEE)Directiveandimplementingregulations,when
customersbuynewelectricalandelectronicequipmentfromTrippLitetheyareentitledto:
• Sendoldequipmentforrecyclingonaone-for-one,like-for-likebasis(thisvariesdependingonthecountry)
• Sendthenewequipmentbackforrecyclingwhenthisultimatelybecomeswaste
ThepolicyofTrippLiteisoneofcontinuousimprovement.Specicationsaresubjecttochangewithoutnotice.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
13-02-027-933161-revB.indb 12 2/7/2013 1:19:21 PM
13
Manual del propietario
Unidades de Distribución de Energía
Monofásicas controlables de 0U
con Medición Individual de Corriente
de Salida
PDUMVR20NET • PDUMVR30NET • PDUMVR30HVNET
(AG-0044) (AG-0045) (AG-0046)
Instrucciones de seguridad importantes 14
Instalación 15
Medidor de carga digital 20
Características 21
Configuración y funcionamiento 23
Mantenimiento 23
Garantía 24
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2013 Tripp Lite. Todos los derechos reservados.
English 1
Français 25
13-02-027-933161-revB.indb 13 2/7/2013 1:19:22 PM
18
Instalación
Parámetros de Red
SigalasindicacionesparacongurarlosparámetrosdedirecciónIPv4eIPv6.Lacontraseña
predeterminadadelmododeterminalesTrippLite.SemuestranparámetrosdemuestradeIP—
suministresupropiainformacióndeIPcuandoconguresuterjeta.
PARÁMETROS DE INTERFAZ DE ETHERNET:
Obtain IPv4 settings automatically using DHCP for Ethernet interface? [Y]
IP address? [10.1.0.165]
Subnet mask? [255.0.0.0]
Gateway address? [10.0.0.1]
Enable DHCPv6 for the Ethernet interface? [Y]
Enable static IPv6 for the Ethernet interface? [N]
IPv6 address? [2001:DB8::1:58:4F43:4849:544C]
Network prefix length? [64]
DNS server? [10.0.0.8]
This card’s host name? [poweralert-061033462177]
This card’s domain? [tlsoftwaredev.local]
Asignación de dirección IP estática
4-5
Congure la PDU en Modo terminal: Luegodeunabrevepausa,apareceráunapágina
deinicializaciónenelprogramadeemulacióndeterminal.Presionecualquiertecladel
tecladoenunlapsode5segundosparacambiarlaconguracióndelaPDU.
Nota: Si ha transcurrido el período de 5 segundos, usted puede reiniciar el PDU mediante:
1. Utilizando una herramienta pequeña o clip para papel para oprimir por 3 segundos el botón de
reestablecer empotrado en el PDU.
2. Presionando cualquier tecla durante o después del proceso de arranque. Esto solicitará un nombre
de ingreso y una contraseña. El nombre y contraseña predeterminados de usuario para este proceso
son ambos “localadmin.” Después de ingresar, escriba “reboot” para iniciar el rearranque de la tarjeta.
¿Presione A para Aceptar la configuración, o M para modificar? M
Ingrese la contraseña raíz: *********
Restablezca la configuración y la contraseña raíz a los valores predeterminados (S/N)? N
13-02-027-933161-revB.indb 18 2/7/2013 1:19:29 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Tripp Lite AG-0044 Owner's manual

Category
Power distribution units (PDUs)
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI