Haier HWF05XC5 User manual

Category
Split-system air conditioners
Type
User manual
0010551959
SPEED
POWER
HI
ONOFF
LOW
1
2
3
4
10
9
8
7
65
MIN
COOL
MAX
COOL
FAN ONLY
Wait 3 Minutes Before
Restarting
HWR05XC7
1
2
14-16
17-18
6-7
8-11
8
8-11
12-16
13
13
18-19
20
3
4
Test power plug before each use:
1. Press ìreset ìbutton.
2 . Press ìtest ìbutton, unit should trip.
3. Press ìresetî button again for use .
Do not use if above test fail.
In the event this device trips , the cause of the malfunction is to
be corrected before further use of the device .
Important:
5
2. MODE Set Switch
2-way
airflow
control
panel
easy
access
filters
SPEED
POWER
HI
ONOFF
LOW
1
2
3
4
10
9
8
7
65
MIN
COOL
MAX
COOL
FAN ONLY
Wait 3 Minutes Before
Restarting
MODEL: HWF05XC5
6
2-way
airflow
control
panel
easy
access
filters
2. fan Speed
TIME OFF
TIME ON
FAN
POWER
ON/OFF
COOL
HI SPEED
LOW SPEED
MODEL: HWR05XC5
Pressing the Fan Speed button of remote
control between High and Low speed.
7
SPEED
POWER
HI
ON
OFF
LOW
1
2
3
4
10
9
8
7
65
MIN
COOL
MAX
COOL
FAN ONLY
Wait 3 Minutes Before
Restarting
MODEL: HWF05XC5
8
Also when you shut off the air conditioner wait for 3 minutes
before turning it on again.
POWER Turns air conditioner off.
SPEED "LOW" Low speed fan operation with cooling or not.
SPEED "HI" High speed fan operation with cooling or not.
This automatically controls the temperature of indoor air. Turn the knob
so that arrow points to the cooler marks for more moderate cooling.
Normal Fan
1. Turn the SPEED mode switch to the "HI" or the "LOW" setting.
2. Set the thermostat control to the temperature mark "FAN ONLY".
Normal cooling
1. Turn the SPEED mode switch to the "HI" or the "LOW" setting.
2. Set the thermostat control to the desire temperature (the mid-point
is a good starting position).
If the room temperature is not satisfactory after a reasonable time, adjust
the control to a warmer setting, as appropriate.
Maximum cooling
1. Turn the SPEED mode switch to the "HI" setting
2. Set the thermostat control to the MAX COOL temperature mark.
Quieter operation
1. Turn the SPEED mode switch to the "LOW" setting.
2. Set the thermostat control as needed.
CAUTION:
1
2
3
9
TIME OFF
TIME ON
FAN
POWER
ON/OFF
COOL
HI SPEED
LOW SPEED
MODEL: HWR05XC5
TEMP/TIME
MODE SPEED TIMER
ON/OFF
1
2
3
4
5
1
Control Panel
10
1. ON/OFF
To turn set ON, press the button. To turn set OFF, press the button again.
2. TIMER
Press TIMER button, for each press, TIMER mode will changes as follows:
TIMER ON
TIMER OFF CANCEL
3. FAN
Pressing the FAN button changes between LOW and HIGH SPEED.
4. MODE
Every time you press this button, it will change between COOL and FAN.
5. TEMP./TIME
Used to set temperature and time.
11
12
window seal gasket
short screws 13/32"
wood screws 31/32"
window seal gasket
short screws 13/32"
wood screws 31/32"
Model: HWR05XC5
Model: HWF05XC5
toprail
13
ìCR2025ì battery
Remote
control
TEMP/TIME
MODE SPEED TIMER
ON/OFF
toprail
HWF05XC5,HWR05XC5
Insert the side curtains into the
top and bottom rails of the air
conditioner. Fasten the curtains
to the unit with 8 short screws
13/32".
Install top rail with 3 short
screws13/32".
ASSEMBLE
CURTAINS/TOP RAIL
11
7
16
17
5
16
13
13
32
1
31
32
11
5
8
11
13
16
34
7
16
20
15
32
14
SPEED
POWER
HI
ONOFF
LOW
1
2
3
4
10
9
8
7
65
MIN
COOL
MAX
COOL
FAN ONLY
Wait 3 Minutes Before
Restarting
1. This unit is designed for installation in standard double hung windows
with actual opening widths of 21
to 35 . The upper and lower sash
must open sufficiently to allow a clear vertical opening of 12
from the
bottom of the sash to the window stool.
2. If storm window presents interference, fasten a 2
wide wood strip(not
included) (OUTER SILL) to the inner window sill across the full width of
the sill. The wood strip should be thick enough to raise the height of
the window sill so that the unit can be installed without interference by
the storm window frame (STORM WINDOW FRAME) or wood strip
(OUTDOORS) to help condensation to drain properly to the outside.
3. Install a second wood strip (approximately 6
long by 3/2 wide and
same thickness as first strip) in the center of the outer sill flush against
the back off the inner sill. This will raise basepan angle .
4. If the distance between STORM WINDOW FRAME and WOOD STRIP
MOUNTED ON TOP OF INNER SILL is more than 1
, two of wood
strip are not necessary.
INNER
SILL
OUTER
SILL
I
N
D
O
O
R
S
O
U
T
D
O
O
R
S
WOOD STRIP
MOUNTED ON
TOP OF INNER SILL
WOOD STRIP
FOR BASEPAN
ANGLE
STORM
WINDOW FRAME
1 MAX.
3/4 CLEARANCE
I
N
D
O
O
R
S
O
U
T
D
O
O
R
S
INNER
SILL
OUTER
SILL
LOCATING UNIT IN
WINDOW
Open the window and mark center line on the
center of the inner sill.
CENTER LINE
INNER SILL
INDOOR SIDE
ATTACH BASEPAN
ANGLE
CENTER LINE
SHORT SCREW13/32"
INNER SILL
OUTER SILL
SHORT SIDE
BASEPAN ANGLE
7,5
7,5
OUTSIDE
INSIDE
Install the basepan angle behind the inner window sill, with
the short side of basepan angle as shown. Use the 2 short
screws13/32" provided.
The basepan angle helps to hold unit securely in place.
Be sure to place basepan angle edge flush against back
of inner sill.
2
15
INSTALL THE AIR CONDITIONER
IN THE WINDOW
Carefully lift the air conditioner and slide it into the open
window. Make sure the bottom guide of the air conditioner
drops into the notches of the basepan angle.
While steadying the air conditioner ,carefully bring the
window sash down behind the upper guide of the air
conditioner.
INSTALL THE SEAL GASKET
AND SASH LOCK
Extend the side curtains to fill the
window opening using 4 wood screws
31/32" to secure them.
Cut the seal gasket to the window
width. Stuff the sash seal between the
glass and the window to prevent air
and insects from getting into the room.
Fasten the basepan angle, using a
short screw13/32".
WINDOW SEAL GASKET
BASEPAN ANGLE
SHORT SCREW13/32"
WOOD SCREW31/32"
WINDOW FRAME
UPPER GUIDE
BOTTOM GUIDE
BASEPAN ANGLE
ABOUT 1/4
16
Always use a soft cloth dampened with water or mild soap
and water solution to wipe the front of the cabinet.
To clean the front panels or the cabinet DO NOT use harsh
chemicals, abrasives, ammonia, chlorine, bleach, concentrated
detergents, solvents or metal scouring pads.
DO NOT use your air conditioner without the air filter in place.
Always unplug your air conditioner before cleaning.
The air filter behind the inlet grille should be checked and cleaned at least once
every 2 weeks (or as necessary) to maintain optimal performance of the air
conditioner.
How to remove the air filter
1. The grille may be opened from the top for easy maintenance after installation.
2. Open the inlet grille by pulling off the exposed door on the top of the unit(based
on the installation).
3. Pull the tab slightly to release the filter. Pull the filter in the same direction as
the opening.
4. Clean the filter with warm, soapy water. The water should be below 40
o
C(104
o
F).
5. Rinse off and gently shake off excess water from the filter. Let it dry before
replacing it.
17
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Haier HWF05XC5 User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI