ENERMAX Triathlor User manual

Category
Power supply units
Type
User manual
The serial number label or warranty seal is defaced, modified or removed.
Feb. 2012
ETL300AWT
ETL350AWT
AC Input Voltage
AC Input Current
100-240VAC, 50-60Hz
5 - 2.5A 5 - 2.5A
DC OUTPUT
3.3V
5V
12V
-12V
5Vsb
Total Power
16A
14A
22A
0.3A
2.5A
16A
14A
26A
0.3A
2.5A
Rated
Combined
Rated
Combined
90W 90W
264W
3.6W
12.5W
300W
312A
3.6W
12.5W
350W
PROTECTION CIRCUIT
DC Rail
3.3V
5V
12V
Activated when output power > 110 ~150% of rated max load.
ENVIRONMENT
Operation ambient : 0~40
o
C (for full rated output)
Storage ambient : -20~70
o
C
Operation: 20% to 90% relative humidity, non-condensing
Storage: 5% to 95% relative humidity, non-condensing
OTHERS
One 12cm twist bearing fan, speed auto controlled.
150(w) x 86(h) x 140(d) mm
Around 2kg
CE / GOST
Over Voltage Protection
Over Power Protection
OVP trigger range
4.5V
7.0V
15.6V
> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25
o
C ambient
(MIL-HDBK-217F standard)
Temperature
Humidity
MTBF
Cooling
Dimension
Weight
Safety/ EMC
20+4P
20+4P
20+4P
20+4P
20+4P
20+4
20+4
20+4
20+4P
0+4P
20+4
20+4P
Web Site hp://www.enermaxjapan.com