LD0.MNSPTOC2 Negative-sequence overcurrent
protection for machines (2).....................................................19
LD0.MPTTR1 Thermal overload protection for motors (1)..... 20
LD0.MVGAPC1 Move (8 pcs) (1)........................................... 20
LD0.PHIPTOC1 Three-phase non-directional overcurrent
protection, instantaneous stage (1)........................................ 21
LD0.PHLPTOC1 Three-phase non-directional
overcurrent protection, low stage (1)......................................21
LD0.PREVPTOC1 Phase reversal protection (1)...................22
LD0.RESCMMXU1 Residual current measurement (1)......... 22
LD0.STTPMSU1 Motor start-up supervision (1).....................22
LD0.TCSSCBR1 Trip circuit supervision (1).......................... 23
LD0.TCSSCBR2 Trip circuit supervision (2).......................... 23
LD0.TRPPTRC1 Master trip (1)............................................. 23
LD0.TRPPTRC2 Master trip (2)............................................. 23
LD0.XGGIO100 Physical I/O states (PSM card X100)...........24
LD0.XGGIO120 Physical I/O states (AIM card X120)............ 24
Unmapped indications................................................................. 25
All premapped three-phase protection function stages,
start and operate/phase-dependent objects added................25
Common data 2......................................................................25
DR.RDRE1 Disturbance recorder signals.............................. 26
LD0.IL1TCTR1 Three-phase CT supervision (1)................... 27
LD0.RCHLCCH1 Ethernet supervision (1)............................. 27
LD0.RESTCTR1 Io CT supervision (1).................................. 27
Registers.......................................................................................... 27
Premapped registers................................................................... 28
Active parameter setting group read and write.......................28
Control structure 1..................................................................28
Control structure 2..................................................................28
Control structure 3..................................................................29
Control structure 4..................................................................29
Control structure 5..................................................................29
Control structure 6..................................................................29
Control structure 7..................................................................30
Control structure 8..................................................................30
Device ID string...................................................................... 30
Event record structure............................................................ 30
Fault record structure header................................................. 34
Fault record data.................................................................... 35
IED real-time clock (in local time mode), read and write
(synchronize)..........................................................................39
IED real-time clock (in UTC time mode), read and write
(synchronize)..........................................................................39
Table of contents
2 REM611
Point List Manual