SCAN 1010 Series Assembly And Instruction Manual

Category
Stoves
Type
Assembly And Instruction Manual
SCAN A/S - DK-5492 VISSENBJERG
Scan 1010 Series
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of pleasure
with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Product registration number
Please indicate the product registration number at any enquiry
ASSEMBLY- AND INSTRUCTIONS MANUAL
UK
2
Table of contents
Technical data ........................................................................................................ 3
Installation
Safety
Technical data and dimensions
Dimension sketch
Type plate
Product registration number
Additional accessories
Loose parts
Assembly .................................................................................................................. 8
Remove packaging
Positioning your wood-burning stove
Load bearing foundation
Distances to combustible floor.
Distance to furniture
Radiance distance to combustible objects
Distances to combustible floor.
Storage of flammable material
Carrying capacity
Distance to flammable materials, shown with insulated flue pipe
Distance to flammable materials, shown with un-insulated flue pipe
Distance to firewall
Mounting with plinth
Mounting of the wall bracket
Burn chamber
Existing chimney and pre-fabricated element chimney
Connection between stove and steel chimney
Requirements for chimney
Connection with 90° elbow pipe
Fresh air intake
Closed combustion system
Instruction for use ............................................................................................. 20
CB technique
Primary air
Secondary air
Baffle plates
Indicator for control of air supply
Instructions for heating ................................................................................... 21
Lighting
Handling fuel
Maintenance ........................................................................................................ 23
Troubleshooting .................................................................................................. 24
Defra ....................................................................................................................... 25
CONTENTS
3
Installation
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able to
recommend a qualified fitter in your area. For information on Scan Dealers, please go to http://scan.dk.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to
inspect and authorize the installation.
The house owner is responsible for ensuring that all necessary national, European and local safety measures are observed during installation and
fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
Safety
Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The
same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary
for the operation and safety of the stove are dismantled or removed.
WARNING
This product contains very strong magnets.
When separating and putting together the magnets, we recommend that you let them glide on (or from) one another. In this way you avoid
squeezing your fingers and damaging the coating of the magnets.
Electronic components should be kept at a safe distance from the magnets to avoid them being influenced or damaged by the magnetic field
(pacemakers, hearing aids, computers, watches, measuring instruments, floppy discs, credit cards, mobile phones etc.).
TECHNICAL DATA
4
Test in compliance with EN 13229
Scan 1010 Technical data Unit
CO Emission at 13% O
2
0,1 %
CO Emission at 13% O
2
1246 mg/Nm
3
Dust @ 13% O
2
12 mg/Nm
3
No
x
@ 13% O
2
41 mg/Nm
3
Efficiency 82 %
Energy efficiency index
109,9
Energy efficiency class
A+
Nominel output 7 kW
Chimney temperature EN 13229 220 °C
Temperature in connecting piece 264 °C
Amount of smoke 7,4 g/sek
Sub-pressure EN 13229 12 Pa
Recommended sub-pressure in connecting piece 16 - 18 Pa
Required combustion air supply 19,8 Nm
3
/h
Fuel Wood
Fuel consumption 2,2 kg/h
Amount of fuel 1,7 kg
Technical data and dimensions
Materials: ................................ Steel plate, galvanised sheet,
Vermicolite, Chamotte, Robax glass
Surface treatment: .......................................................................... Senotherm
Max. wood length: ..................................................................................... 50 cm
Weight Scan 1010: .....................................................................approx 135 kg
Weight big box:...............................................................................approx 32 kg
Weight little box:............................................................................approx 20 kg
Connecting piece internal diameter: .............................................. 144 mm
Connecting piece external diameter: .............................................. 148
mm
Approval type: ................................................................ Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other
words, you should let the fire die down until only the embers are left,
before refuelling.
The Scan 1010 was build in compliance with the homologized product
type specified in the Assembly- and Instructions Manual provided
with the product.
The DoP declaration of performance is available from scan.dk
Please note:
You get the best use of the stove by using a
”top-down lighting”, see page 21.
TECHNICAL DATA
5
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010005.idw
91010005
målskitse Scan 1010
13-04-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
479
649
324,5 D
5
7
2
143 D
9
3
F
9
9
,
5
A
5
6
4
,
5
C
799
399 B
5
7
2
5
6
5
C
399 D
1
8
8
B
2
9
1
B
324,5 B
5
TECHNICAL DATA
Dimension sketch Scan 1010
A Centre rear outlet
B Top outlet
C Height to the beginning of the
connecting piece at top outlet
D Centre of fresh air intake bottom
F Fresh air intake at the back of the stove
6
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010008.idw
91010008
Mål ovn, base, sokkel
20-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
1
0
5
7
2
2
8
1
1
0
9
9
7
2
649
324,5 B
1
8
8
B
2
9
1
B
2
5
0
F
4
9
3
F
8
7
3
A
479
9
6
5
C
324,5 D
143 D
TECHNICAL DATA
Dimension sketch Scan 1010
A Centre rear outlet
B Top outlet
C Height to the beginning of the
connecting piece at top outlet
D Centre of fresh air intake bottom
F Fresh air intake at the back of the stove
4
7
9
6
4
9
2
8
1
4
1
1
3
1
9
109
6
4
9
4
1
1
109
4
7
9
6
4
9
2
8
1
4
7
9
2
8
1
3
1
9
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010034.idw
91010034
vægbeslag løse
12-08-2016
mbp
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010033.idw
91010033
Friskluft skjuler
12-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
7
TECHNINIAI DUOMENYS
TECHNICAL DATA
Large wall bracket
Small wall bracket
Large module
- is not to be
used under the
stove!
Small module
Cover for
fresh air inlet
Large module
with fresh air
inlet and heat
shield.
Large plinth
Small plinth
Additional accessories
8
XX00000
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010003.idw
91010003
Ovn bag
23-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010010.idw
91010010
indpakning
24-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
Scan 1010
Freestanding room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010600
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Back: 150 mm - Front: 1400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
TECHNICAL DATA/ASSEMBLY
Type plates
All Scan wood-burning stoves are fitted with a type plate, that speci-
fies the approval standards and the distance to flammable materials.
The type plate is located at the back of the stove.
Product registration number
All wood-burning stoves are provided with a product registration
number.
The product registration number is located at the back of the stove.
Please make a note of this number on the front page as you will
always have to state it when contacting your dealer or Scan A/S.
Type plate
Product
registration
number
Loose parts
Glove
Connecting piece
Gasket for connecting piece
Screws for connecting piece 5 x 12 mm
Connecting piece for fresh air inlet
Screws for connecting piece/fresh air 4 x 10 mm
Decor ring for top outlet
• Screw M5x6 (UK)
Additional accessories
Large/small module
Large/small plinth
Large/small wall bracket
Protection glass for large/small module
Magnets
Cover for fresh air inlet
Small floor plate (glass or steel)
Large floor plate (glass or steel)
Disposal of packaging
Your Scan stove may come supplied with the following packaging:
Wood packaging:
The wood packaging can be reused and after final use can be incine-
rated as a CO2 neutral product or sent for recycling.
Flamingotop:
Send for recycling or waste disposal.
Foam:
Send for recycling or waste disposal.
Plastic bags:
Send for recycling or waste disposal.
Stretch film/plastic film:
Send for recycling or waste disposal.
9
Scan 1010
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064049.idw
90064049
Brændbar + uisoleret røgrør - Scan 64 uden sideglas
23-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
150
350
340
595
100
363
628
100
3
2
4
Min. 400 mm
Min. 1400 mm
Min.
140 mm
Min.
140 mm
Positioning your wood-burning stove
The wood-burning stove must be set up so that the stove itself, the
flue pipe, and the chimney can all be cleaned.
Load bearing underlay
All of the products in our portfolio are classified as light-duty firepla-
ces; in most cases, there is no need to reinforce the floor, so that you
can typically use the normal floor.
However, you should make sure that the load bearing underlay can
bear the weight of the wood-burning stove and that of the chimney.
Distance to furniture: 1400 mm
But please check to avoid furniture or other furnishings being dried
out due to being too close to the stove.
All national and local requirements concerning safety distances for
wood burning stoves must be respected.
If you connect the stove to a steel chimney, the safety distances of
the steel chimney must also be respected.
Radiance distance to combustible objects out-
side the modules.
Distances to combustible floor.
Remember to place a floor plate.
ASSEMBLY
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010013.idw
91010013
opbevaring af brænde
30-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
10
Max
MAX
* * *
*
*
* *
*
*
*
*
* *
** *
*
*
= 10 mm
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010043.idw
91010043
moduler
16-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
Max
MAX
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010043.idw
91010043
moduler
16-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
285 285
KGKG
Storage of flammable material
You can store wood under
the stove in the module
with heat shield and fresh
air inlet.
ASSEMBLY
Carrying capacity
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064049.idw
90064049
Brændbar + uisoleret røgrør - Scan 64 uden sideglas
23-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
150
350
340
595
100
363
628
100
3
2
4
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064049.idw
90064049
Brændbar + uisoleret røgrør - Scan 64 uden sideglas
23-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
150
350
340
595
100
363
628
100
3
2
4
50
50
50
50
500
400
150
50
11
Distance to flammable materials, shown with insulated flue pipe*
Distance to flammable materials, shown with un-insulated flue pipe*
The distances presuppose the use of an insulated flue pipe with min. 30 insulation all the way to the stove.
Parallel rear wall installation
Parallel rear wall installation
45° Corner installation
45° Corner installation
ASSEMBLY
Scan 1010
Scan 1010
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010051.idw
91010051
Scan 1010 - Montage røgstuds i topafgang
12-02-2018
ken
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
1000
1000
1000
0
0
0
12
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
350
1000
0
1000
300
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010051.idw
91010051
Scan 1010 - Montage røgstuds i topafgang
12-02-2018
ken
Scan 1010
VÆGT:
AREAL:
N/A
N/A
A
C
D
B
Distance to firewall*
110 mm brick or other material with a corresponding insulation ability.
The indicated distances are valid for insulated as well as un-insulated smoke pipes.
Flammable material
Firewall
ASSEMBLY
* All national and local requirements concerning safety distances for wood burning stoves must be respected.
Scan 1010
Connecting piece
The insert is prepared for a top flue outlet from the factory.
The flue connection piece (A), gasket for the flue connection piece (B), screws (C) and cover ring (D)
can be found in the stove’s combustion chamber.
13
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010018.idw
91010018
expl. tegning
08-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010019.idw
91010019
Emb afbræk
10-06-2016
hms
Scan 1010
VÆGT:
AREAL:
0,04 kg
20656 mm^2
DIM.:
Scan A/S
A
A
A
B
C
D
D
E
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010014.idw
91010014
sokkel magnet
31-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010015.idw
91010015
justering af sokkel
08-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
A ( 0,40 : 1 )
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010039.idw
91010039
indstil ben
23-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
1.
3.
2.
First mount the module with fresh air inlet on the plinth and then the stove. Place the magnets on the
next modules before mounting them.
Please follow the order below A, B, C, D, and E.
It is important to adjust the plinths before mounting the modules.
Press the two distance triangles out of the packing. These are used for the proper
mounting of the magnets. The magnets are to be found inside the plinth at the delivery.
Mounting with plinth
ASSEMBLY
ccc
14
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010020.idw
91010020
vægbeslag
13-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010029.idw
91010029
afmont. af dæksler
21-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010027.idw
91010027
Varmeskjold afmont.
20-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
Scan 1010 Wall
Wall mounted room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Front: 1400 mm - Bottom: 400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
Scan 1010 Wall
Wall mounted room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Front: 1400 mm - Bottom: 400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
A
C
E
D
B
F
B
1.
2.
Scan 1010 Wall
Wall mounted room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Front: 1400 mm - Bottom: 400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010048.idw
91010048
røgstuds
06-10-2016
hms
Scan 1010
VÆGT:
AREAL:
0,61 kg
69343 mm^2
DIM.:
Scan A/S
Mounting of the wall bracket
First dismount the heat shield at the rear. The heat shield is not used on the wall model.
Pull the stove out of the module. Mount the fittings (A) at the top and the two adjustment fittings (B) at the bottom. If you want a rear outlet,
the cover plate (C) on the back of the stove must be removed and placed in the top outlet. Fit the connecting piece with the supplied gasket and
screws (D). The cover plate (E) at the rear of the module must also be removed. Place the type plate (F).
Mount the fittings in the same way on the other modules.
Is not to be
used on the wall
model.
Please note
that the delivered type plate must
be placed on the stove after dis-
mounting the heat shield.
ASSEMBLY
Content:
Small wall bracket + number plate
Content:
Large wall bracket + number plate
Place the delivered
type plate.
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010032.idw
91010032
Ophængs mål
08-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
118,6
109
99,3
291
291
835
98,1
270
gulv
15
Min. 400 mm
Min. 874 mm
91± 2 mm
Wall-hung model
Installation must be planned and executed in accordance with natio-
nal and local building regulations.
The stove must only be fitted to a non-flammable wall. There must be
no form of flammable component in the wall. In the case of thin walls,
nor must there be any behind the wall. The load-bearing capacity of
the wall must be checked under all circumstances.
To ensure correct installation we recommend that a building expert
be commissioned to plan and outline the installation with a view to
subsequent approval.
For wall installation we recommend using the wall brackets supplied.
If a chimney is installed on top of a wall-hung model, the chimney
must be fully self-supporting. It must not rest on the wood-burning
stove. There must be a distance of at least 6 mm between the first
section and the flange on the flue collar. Please consult a specialist.
Scan A/S disclaims all liability for the installation of wall-hung
wood-burning stoves.
Dimensional drawings of the wall brackets
Combustible floor
ASSEMBLY
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010022.idw
91010022
opboring af beslag
14-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010031.idw
91010031
væg step by step
28-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
91±2
mm
1
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010030.idw
91010030
vægbeslag justering
28-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
3
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010023.idw
91010023
justerskive
14-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
2
4
A
B
C
16
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010045.idw
91010045
indikatorplade
19-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010045.idw
91010045
indikatorplade
19-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
The smoke pipe should be lead 9 1±2
mm out of the wall in order for it to
fit on the stove’s connecting piece.
See dimensional drawing.
1) Drill the holes with the drilling template (a)
2) Replace the drilling template (a) with the
adjustment template (b)
3) Can be adjusted up and down. Use a spirit level.
4) Mount the module (A) on the wall fitting.
Place the stove (B). Put on the indicator plate (C).
Mounting of the wall bracket
ASSEMBLY
17
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010042.idw
91010042
opstilling med knærør
25-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010046.idw
91010046
ovn med 90 gr røgrør
21-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1001\91001011.idw
91001011
Brændkammerforing, eksploderet
18-04-2012
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
Existing chimney and pre-fabricated element
chimney
If you intend to connect your stove to an existing chimney, it makes
sense to contact an authorised Scan dealer, or a local chimney sweep
for advice. These experts will also let you know if your flue needs
renovating.
When connecting a pre-fabricated element chimney, follow the
manufacturer’s connection instructions for the relevant chimney
type.
Connection between stove and steel chimney
Your Scan dealer, or local chimney sweep, can advise you on choosing
a make and type of steel chimney. This ensures that the chimney
will match your wood-burning stove. As a general rule, the length of
the flue should not be less than 3,5 m measured from the top of the
wood-burning stove.
Some weather or installation conditions might require another
length.
Choosing the wrong length or diameter of steel chimney could impair
functionality.
Always observe the chimney vendor‘s instructions precisely.
Requirements for chimney
The chimney must be labelled T400 and G for soot testing.
Connection with 90° elbow pipe
If you intend to use an elbow pipe with the Scan 1010 we recommend
the use of a curved elbow pipe to improve the draft.
If you are connecting your stove using a sharp elbow bend, the clea-
nout door should be in the vertical section, such that the horizontal
part can be cleaned through it.
Curved elbow pipe
Sharp elbow pipe
Baffle plate
in steel
Baffle plate
in vermicu-
lite
Combustion chamber lining
ASSEMBLY
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1001\91001041.idw
91001041
Nederste røgvenderplade
15-05-2012
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1001\91001041.idw
91001041
Nederste røgvenderplade
15-05-2012
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
18
1.
2.
3.
5.
6.
7.
8.4.
Place the bottom stones with the inclined edge
turning to the rear and downwards.
Place the log guard against the front of the
insert.
The rear burn chamber plates must be mounted
so that the holes of the plates are placed preci-
sely over the tertiary holes of the insert.
Mount the lower baffle plate. The baffle plate
must be supported by the rear plates.
Mount the pins and put
the plate in place.
Burn chamber
Note that the baffle plates are made of porous, ceramic material, and can break. Exercise care when working.
Mount the rear plates. The side plates keep the
rear plates in place, so that these do not fall over.
Mount the left burn chamber plate.
Mount the right burn chamber plate.
ASSEMBLY
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010038.idw
91010038
friskstuds bag
18-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010036.idw
91010036
Frisklfuft bund
18-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
19
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010003.idw
91010003
Ovn bag
23-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010037.idw
91010037
dækplade friskluft
18-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
Fresh air intake
In a well-insulated house, the air used up by the burning process has to
be replaced. This particularly applies to houses with mechanical ven-
tilation. There are different ways of making sure that an air exchange
takes place. The most important thing is to ensure that there is a sup-
ply of air to the room where the wood stove is located. The external
wall vent must be located as close to the wood stove as possible, and
you must be able to close it when you are not using the wood stove.
Beware that the valve in the outer wall cannot be covered by accident!
National and local building regulations must be followed with regard
to the connection of fresh-air intake.
Closed combustion system
You should use the closed combustion system for the wood-burning
stove if you live in a newly-built, airtight home. Outside air for com-
bustion is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when
the stove is not in use.
Minimum Ø100 mm ventilation pipe, maximum length: 6 m with
a maximum of one bend
The connecting piece for external combustion air is to be found in the
packaging.
If the external combustion air is connected at the rear, the dis-
mounted plate must be mounted on the hole for external air in the
bottom of the stove.
NOTE: if the stove has a fresh air connexion or closed combustion,
the ventilation pipe must be open, when the stove is in use!
Mounting of external air supply
Dismount the cover plate behind or below the casette
Mount the Ø100 sleeve.
Mounting of external air supply
on the rear of the cassette.
Dismount the cover plate at the rear and mount it in the bottom.
Mounting of external air supply
on the bottom of the cassette.
Mount the Ø100 sleeve.
Ø100 sleeve
Ø100 sleeve
External combustion
air on the bottom of
the cassette
External air
supply on the
rear of the cas-
sette
ASSEMBLY
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010004.idw
91010004
CB teknik
18-03-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
20
0% - 100%
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010047.idw
91010047
indikator luft
21-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
0% - 100%
Baffle plate
CB-technique
Primary air
Secondary air
Primary air
Log guard
Secondary air
Adjustment of air supply
CB-technique (Clean Burning)
The wood-burning stove is equipped with CB technology. In order
to ensure an optimal combustion of released gases under the inci-
neration process, air will pass through a specially developed canal
system. The heated air is led into the combustion chamber through
the small holes at the rear of the burn chamber. This airflow is driven
by the combustion rate and thus cannot be regulated.
Primary air
The primary air regulation mechanism is used for lighting the fire, or
to boost the burning process when you put wood on. The primary air
vent can be 0 - 30% open if you use hard wood fuel such as oak and
beech. You can close the primary air vent if you use soft wood such
as birch or pine for fuel.
Settings for normal load: 0 - 30%
Secondary air
Secondary air is pre-heated and fed indirectly to the fire. At the
same time, the secondary airflow cleans the glass pane to avoid soot
build-up. If you over-restrict the secondary airflow, soot can build up
on the glass pane. The secondary airflow determines the heat output
from your wood stove.
Settings for normal load: 50 - 70%
Baffle plates
The baffle plates are located in the upper part of the combustion
chamber. The plates hold back smoke, making sure it stays inside
the combustion chamber for a longer time before escaping through
the chimney. This reduces the smoke gas temperature as the gases
have more time to dissipate heat to the wood-burning stove. The
baffle plates must be removed for sweeping; see „Maintaining your
wood-burning stove“. Note that the baffle plates are made of porous,
ceramic material, and can break. Exercise care when working. The
baffle plates are subject to wear and tear, and are not covered by
the warranty.
INSTRUCTIONS FOR HEATING
ASSEMBLY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

SCAN 1010 Series Assembly And Instruction Manual

Category
Stoves
Type
Assembly And Instruction Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages