Whenselected,moneyheldinescrowfor30minuteswithoutfurtherescrow
orcycleactivitywillbecleared.
00 NotSelected"OFF."
CE Selected"ON."
PressDEI_ICATES&KNITSkeypadonceforthisselection.
PressWOOI.ENSkeypadoncetoadvancetonextcode.
r.800r.
800
TOP SPIN SPEEDRPM
This can be selected from the following spin speeds: 600 rpm, 750 rpm,
800 rpm, 1000 (displays as 999) rpm.
Step between speeds by pressing PERMANENT PRESS.
Currently set for 800 rpm.
PressWOOLENS keypad once to advance to next code.
U.00 U. PENNY INCREMENT OFFSET
00 This represents the penny increment price offset used in
Generation 2 (Enhanced Debit) PR models. Choose from 0-4 pennies by
pressing the PERMANENT PRESS keypad.
Press WOOI.ENS keypad once to advance to next code.
A1.00 A1. PREWASH LENGTH
00 This is the number of minutes of PREWASH.
Choose 0 to disable the prewash or select between 2 and 7 minutes by
pressing the PERMANENT PRESS keypad.
Press WOOI_ENS keypad once to advance to next code.
A2.03 A2. FINAL SPIN LENGTH
03 This is the number of minutes of final high speed spin. Choose from
3-8 minutes by pressing the PERMANENT PRESS keypad.
Press WOOI.ENS keypad once to advance to next code.
If cycle counter (90C) is selected, the following is true:
100 Represents the number of cycles in HUNDREDS
200 Represents the number of cycles in ONES
Total = 225 cycles
This is "VIEW ONI.Y" and cannot be cleared.
1 02 = 200
2 25 = 25
Press WOOI.ENS keypad once to advance to next code.
If money counter (1.0C or 1.C0) is selected, the following is true:
300 Number of dollars in HUNDREDS
400 Number of dollars in ONES
500 Number of CENTS.
3 01 = 100
4 68 = 68
5 75 = 75
Total =$168.75
END of SETUP PROCEDURES.
EXIT FROM SETUP MODE
PI]) Models: Reinstall access door.
PR Modem: Remove power, open console, reinsert plug into AA1, close console, and apply
power.
To enter the "Washer Diagnostic Mode," first enter "Start Operating Setup." Then press and
hold the DEI_ICATES & KNITS key for 1 second while in any of the setup codes one through
six, anytime a diagnostic code is present, or while dAS displays if operating with Maytag Data
Acquisition setup.
On entry to diagnostic mode the entire display will flash, a cycle in process is canceled,
money in escrow is cleared, and diagnostic codes are cleared. If a diagnostic code persists, it
must be corrected before the following cycle options are permitted.
There are five possible ways to initiate cycle activity from diagnostic mode as follows:
1. Clean Washer cycle - With the entire display flashing, this cycle is started by pressing the
BRIGHTS keypad.
Use the Clean Washer cycle once a month to keep the inside of your washer fresh and
clean. This cycle uses a higher water level. Use with AFFRESH r_ washer cleaner tablet or
liquid chlorine bleach to thoroughly clean the inside of your washing machine. This cycle
should not be interrupted. See "Cleaning Your Washer."
IMPORTANT: Do not place garments or other items in the washer during the Clean
Washer cycle. Use this cycle with an empty wash drum.
2. Cycle Credit - With the entire display flashing, a cycle may be credited by pressing the
PERMANENT PRESS keypad (CC will display). When the service mode is exited "SEI.ECT
CYCI E" will be displayed unless the end-of-cycle door opening is required.
3. Manual I_oad Test Cycle - With the entire display flashing, this cycle is started by pressing
the WHITES keypad. This cycle provides more typical full length fills, tumbles, drains and
actuator dispenser movement allowing for a more thorough analysis of the washer
operation, including pressure switch behavior.
4. Quick Spin Cycle - With the entire display flashing, this cycle is started by pressing the
COl_ORS keypad. This cycle provides a method to quickly drain and spin (remove water
from the washer) if desired.
5. History Overview Test Cycle - With the entire display flashing, this cycle is started by
pressing the WOOI_ENS keypad. This cycle provides a quick verification that the cold and
hot water valves, dispensers, and pump motor are working and actuator dispenser
movement. It also includes drain and spin operations.
Pressing the DELICATES & KNITS keypad will exit diagnostic mode and cancel a diagnostic
cycle in process.
16