PRINTED IN UNITED STATES OF AMERICA
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5707
fax: 775-689-5976
www.wellsbloomfield.com
SERVICE INSTRUCTIONS
SOLENOID VALVE RETROFIT KIT NUMBERS
84571 84572 84575 84574
86606 86644 86650
600
Wrench p/n 86660 is designed to allow easy removal of
the braided faucet hose from the plastic solenoid valve.
FOR REMOVING BRAIDED HOSE:
IMPORTANT: Shut-off water supply to brewer before
removing faucet hose.
1. Slide the 7/16" end of the wrench between the valve
body and the white ring on the extreme end of the
metal hose fitting.
2. Pressure on the white ring toward the metal ferrule
releases the clinch ring, allowing the hose to be
easily slid off of the solenoid bypass outlet.
3. Reinstall hose by pressing end of hose onto bypass
outlet until it is fully seated.
FOR REMOVING FLARE FITTING
1. Slide the 5/8" end of the wrench over the flats on the
inlet fitting of the valve.
2. Hold the wrench to prevent the inlet fitting from
turning while installing or removing the inlet water
supply flare nut.
P/N 86660 BRAIDED HOSE WRENCH
p/n 76661 Rev. A ECN-13394
I
600 080211 cps
1 of 1
7/16” for
BRAIDED HOSE
5/8” for
VALVE FITTING
WHITE
CLINCH
RING
BYPASS
OUTLET
WRENCH
#86660
SLIDE WRENCH BETWEEN
VALVE AND CLINCH RING.
PRESS CLINCH RING TOWARD
METAL FITTING TO RELEASE.
WRENCH
CLINCH RING
METAL
HOSE
FITTING
VALVE