FCI Home Appliances ECCB 36” User manual

Type
User manual
Installation Manual
for Cooktops Built-in Electric
Models
ECCB 30”
ECCB 36”
TCCB 30”
TCCB 36”
ENGLISH: Before you begin, read these instructions completely and carefully. Page 3 and 4
IMPORTANT FOR OWNER: Save these instructions for the local electrical inspector use. Leave this manual with owner for future
reference.
FRENCH: Avant de commencer, lisez complètement et soigneusement ces instructions. Page 15 et 16
IMPORTANT POUR LE PROPRIETAIRE : Gardez ces instructions pour une utilisation d’inspection électrique locale. Le
propriétaire doit garder ce manuel pour de futures références..
ESPAÑOL: Antes de empezar lea atenta y completamente estas instrucciones. Pagina 27 y 28
IMPORTANTE PARA EL PROPIETARIO: Guarde estas instrucciones para el uso del inspector eléctrico local. Deje este manual
al propietario para futuras referencias.
The contents are subject to change without notice
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
3
Table of Contents
Page
Special Warnings.............................................................. 4
Product Dimensions and Cutout Requirements............. 5
Important Preparation Suggestions..................................... 7
Cooktop Installation.......................................................... 8
Electrical Connections.................................................... 12
General information........................................................... 12
3-Wire branch circuit......................................................... 13
4-Wire branch circuit......................................................... 13
Pay attention to these symbols present in this
manual
DANGER
You can be killed or seriously injured if you don't
IMMEDIATELY follow instructions.
WARNING
This is the safety alert symbol. This symbol
alerts you to potential hazards that can kill or
hurt you and others.
You can be killed or seriously injured if you
don't follow these instructions.
READ AND SAVE THESE INSTRUCTIONS.
To installer:
Leave these instructions with the appliance.
To customer:
Retain these instructions for future reference.
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result in
personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
4
WARNING
Special Warnings
Please read all instructions before using this appliance
Proper installation is your responsibility. Have a
qualified technician install this cooktop.
Important:
Observe all governing codes and ordinances.
Write down the model and serial numbers before
installing the cook top. Both numbers are on the
serial rating plate located on bottom of cooktop
box.
Before Starting Installation
WARNING
It is the customer's responsibility to contact a
qualified electrical installer. To assure that the
electrical installation is Adequate and in
conformity with national electrical code:
ANSI/NFPA 70-latest edition** or CSA standards
C22.1-94, Canadian Electrical Code, part No.0-
M91 - latest edition*** and all local codes and
ordinances.
Copies of the standards listed may be obtained from:
** National Fire Protection Association One Batterymarch Park
Quincy, Massachusetts 02269
*** CSA International 8501 East Pleasant Valley Rd. Cleveland,
OH 44131-5575
To eliminate the risk of burns by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If he
cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects
horizontally a minimum of 5" (12,7 cm) beyond the
bottom of cabinet.
Cooktop Installed over Oven Installation
Only certain specified cooktop and oven models are
approved for cooktop over oven installations.
Cooktops approved for this type of installation will
have an approval label located on the outside of the
burner box. If you do not find this label, contact your
dealer to confirm that cooktop is approved. The label
on the bottom of your cooktop lists the cooktop and
oven combinations that are approved for this type of
installation. Refer to oven manufacturer's Installation
Instructions for approval for built-under use and
proper cut-out dimensions.
INST 022
1-1/2” (4 cm) min
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
5
Product Dimensions and Cutout Requirements
Figure 1. Touch control
Figure 2. Energy regulator
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
6
Figure 3. Cutout dimensions and requirements
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
7
CUTOUT
WIDTH
A B C D E F G
30”
(76.2cm)
28-1/2”
(72.4 cm)
29”
(73.7 cm)
19-1/4”
(49.0 cm)
19-5/8”
(49.8 cm)
30”
(76.2 cm) min
36”
(91.4 cm)
33-7/8”
(86 cm)
34-9/16”
(87.8 cm)
19-1/4”
(49.0 cm)
19-5/8”
(49.8 cm)
36”
(91.4 cm) min
18” (45.7 cm)
min
Height from
countertop to
nearest
cabinet on
either side of
unit
30” (76.2 cm)
min.
(see note*)
Clearance from
countertop to
unprotected
overhead
surface
2” (5 cm) min
Clearance from
cutout to side
wall on the left
and right of the
unit
13” (33 cm)
Depth of
unprotected
overhead
cabinets
IMPORTANT
Under the cooktop it is necessary to install a partition,
spaced at least 15 mm. from the bottom of the
appliance as shown in figure 3. If an oven or another
appliance is built in under the cooktop, this partition
isn't necessary but in any case keep this clearance
* NOTE
24” (61 cm) min. clearance if bottom of wood or metal cabinets is
protected by not less than 1/4“ (0.6 cm) flame retardant millboard
covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm)
stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper.
30”(76.2 cm) min. clearance between top of cooking platform and bottom
of unprotected wood or metal cabinet
Important Preparation Suggestions
1. Chamfer all exposed edges of decorative laminate
to prevent damage from chipping.
2. Radius corners of cutout and file to Insure
smooth edges and prevent corner cracking.
Recommend 1/4“or 3/8“diameter drill In each
corner.
3. Rough edges, inside corners which have not been
rounded and forced fits can contribute to cracking
of the countertop laminate.
This cooktop has been designed with wide
tolerances of cut-out to cover possible
replacement with other brands. We recommend to
that you consider the minimum dimension of cut-
out size In the case of new Installation.
Some cut out sizes for possible replacements:
Dim.
Inches cm
30"
29" x 19-5/8” 73,7 x 49,8
36"
34-9/16" x 19-5/8” 87,8 x 49,8
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
8
Cooktop Installation
WARNING
Excessive Weight Hazard
Use two or more people to move and install
cooktop.
Failure to do so can result in back or other injury.
Cut Hazard
Beware of sharp edges. Use the polystyrene ends
when carrying the product. Failure to use caution
could result in minor injury or cuts.
Always consult the countertop manufacturer for
specific instructions.
Ensure the countertop is square and level and
ensure no structural members interfere with space
requirements.
Prepare the cut-out according to the instructions
(see cut-out dimensions).
Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand heat
(up to 200 °F / 93 °C).
Figure 4. Tools you will need
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
9
Step 1
Remove packaging materials and literature package
from the cooktop before beginning installation.
Remove Installation Manual from literature pack and
read them carefully before you begin.
Figure 5. Parts
Step 2
Place a towel or table cloth onto the counter top. Lay
the cooktop upside down onto the protected surface.
Figure 6.
Step 3
A foam tape is provided to seal the cooktop edges to
the countertop.
Apply tape approximately 1/16" (1.5 mm) from the
glass edge to the underside of the cooktop glass. Use
tape around the entire glass perimeter. Cut off excess
where tape ends butt.
Figure 7.
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
10
Step 4
Four clamp brackets are provided to clamp the
cooktop to the countertop. The bracket may be
installed before the cooktop is placed into the cutout.
Install the clamp brackets as shown on the front and
back of the box then rotate brackets so that they do
not extend beyond edge of burner box bottom.
Tighten screws just enough to hold brackets in place
when cooktop is put into cutout.
Figure 8.
Step 5
Insert the cooktop centered into the cutout opening.
Make sure the front edge of the counter top is parallel
to the cooktop. Make final check that all required
clearances are met.
Figure 9.
Step 6
Loosen the screws, rotate the brackets so that they
extend beyond edge of the burner box. Tighten
screws securely.
Figure 10.
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
11
Figure 11.
Figure 12.
WARNING
THE CONDUIT IS 3 FEET LONG
The junction box, must be located where it will
allow considerable slack in the conduit for
serviceability.
Important:
For solid surface material installations such as
Surel™ and Corian
®
, consult with solid surface
manufacturer. Apply heat reflective tape such as
Scotch® Aluminum Foil Tape #425 or #427
around the cutout so that it folds over on the top
and sides.
Do not wrap the tape underneath the cooktop.
Be sure the tape extends beyond the outermost
flange of the cooktop. All corners should be
covered with tape.
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
12
Electrical Connections
DANGER
Disconnect power before servicing the
product. Failure to do so could result in death
or electrical shock.
General information
This cooktop does not require a neutral connection. If
the cooktop is to be completely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Figure 13. Location of serial tag
Connect with copper wire only
If the house has aluminum wiring, follow the
procedure below:
1. Connect the aluminum wiring to the copper wire
by using special connectors designed and
Underwriters Laboratories-listed for joining copper
to aluminum. Follow the electrical connector
manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with
local codes and industry- accepted wiring
practices.
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly to junction box. Do not
cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
WARNING
Improper connection of aluminum house wiring to
the copper leads can result in a serious problem.
Model Power
Required
power
supply
Minimum
supply wire
size
30”
TCCB 33052/**
TCCB 33053/**
TCCB 33066/**
TCCB 33067/**
ECCB 33050/**
ECCB 33051/**
ECCB 33070/**
ECCB 33071/**
6.7 kW
240 V 28 A
60 Hz
No.
10AWG
TCCB 33656/**
TCCB 33657/**
TCCB 33668/**
TCCB 33669/**
7.6 kW
240 V 32 A
60 Hz
No.
10AWG
36”
ECCB 33654/**
ECCB 33655/**
ECCB 33674/**
ECCB 33675/**
9.4 kW
240 V 39 A
60 Hz
No.
10AWG
*Digits identifying color cooktop
National Fire Protection Association
Batter/march Park Quincy, Massachusetts 02269
A three-wire, single phase, 240 volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the
electrical wiring and hookup be accomplished by a
competent electrician.
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
13
Recommended Minimum
kW Rating on
serial plate
Circuit protection
in amperes
Wire size
(AWG)
0-4.8
20 12
4.9-6.9
30 10
7.0-9.9
40 8
10.0-11.9
50 8
12.0-14.9
60 6
Be sure your appliance is properly installed and
grounded by a qualified technician. Ask your
dealer to recommend a qualified technician or an
authorized repair service. This cooktop does not
require a neutral connection. If the cooktop Is to
be completely enclosed In a cabinet, feed the
cooktop cable through the opening in the cabinet.
Make the electrical connection following the
appropriate steps for your installation.
This appliance is manufactured with a green ground
wire connected to the cooktop chassis. After making
sure that the power has been turned off, connect the
flexible conduit from the cooktop to the junction box
using a U.L. listed conduit connector. Figures 14 and
15 and the instructions provided below present the
most common way of connecting the cooktops. Your
local codes and ordinances, of course, take
precedence over these instructions. Complete
electrical connections according to local codes and
ordinances
DANGER
Risk of Electric Shock, frame grounded to
neutral of appliance through a link.
Grounding through the neutral conductor is prohibited
for new branch-circuit installations (1996 NEC);
mobile homes; and recreational vehicles, or in an area
where local codes prohibit grounding through the
neutral conductor.
3-Wire branch circuit
Where local codes allow the connection of ground
wire from the cooktop to the branch circuit neutral wire
(gray or white colored wire) proceed as follows (see
figure 14).
1. If local codes permit, connect the green GROUND
wire from the cooktop to the branch circuit neutral
wire (gray or white colored wire).
2. Connect the red and black leads from the cooktop
to the corresponding leads in the junction box.
Figure 14.
4-Wire branch circuit
Refer to figure 15:
1. Connect the green ground wire from the cooktop
to the ground wire in the junction box (bare or
green colored wire).
2. Connect the red and black leads from the cooktop
to the corresponding leads in the junction box.
3. Connect the white wire from the cooktop to the
neutral (gray or white) wire in the junction box.
4. Terminate and insulate the neutral (gray or white
colored wire) in the junction box.
Figure 15.
Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
14
Notes
FCI Home Appliances, LLC
2340 s. Arlington Heights Rd.,
Suite 420
Arlington Heights, IL 60005
09FX1840 – 01/07
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

FCI Home Appliances ECCB 36” User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI