MQ Multiquip MQ-YELLOW-SUBMARINE Operating instructions

Type
Operating instructions
OPERATION AND PARTS MANUAL
Revision #1 (03/22/10)
YELLOW SUBMARINE
SUBMERSIBLE PUMP
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
To find the latest revision of this
publication, visit our website at:
www.multiquip.com
PAGE 2 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
TABLE OF CONTENTS
NOTE
Specification and
part number are
subject to change
without notice.
MQ Yellow Submarine
Submersible Pump
Table Of Contents ................................................... 2
Parts Ordering Procedures ..................................... 3
Safety Information ................................................ 4-7
Specifications .......................................................... 8
General Information ................................................ 9
Components.......................................................... 10
Operation ......................................................... 11-12
Troubleshooting/Cable .......................................... 13
Pump Assy. ....................................................... 14-15
Terms And Conditions Of Sale — Parts ................ 16
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 3
PARTS ORDERING PROCEDURES
www.multiquip.com
Ordering parts has never been easier!
Choose from three easy options:
WE ACCEPT ALL MAJOR CREDIT CARDS!
When ordering parts, please supply:
R Dealer Account Number
R Dealer Name and Address
R Shipping Address (if different than billing address)
R Return Fax Number
R Applicable Model Number
R Quantity, Part Number and Description of Each Part
R Specify Preferred Method of Shipment:
UPS/Fed Ex DHL
N Priority One Tr uck
N Ground
N Next Day
N Second/Third Day
If you have an MQ Account, to obtain a Username
and Password, E-mail us at: parts@multiquip.
com.
To obtain an MQ Account, contact you
r
District Sales Manager for more information.
Order via Internet (Dealers Only):
Order parts on-line using Multiquip’s SmartEquip website!
N View Parts Diagrams
N Order Parts
N Print Specification Information
Note: Discounts Are Subject To Change
Goto www.multiquip.com and click on
Order Parts
to log in and save!
Use the internet and qualify for a 5% Discount
on Standard orders for all orders which include
complete part numbers.*
Order via Fax (Dealers Only):
All customers are welcome to order parts via Fax.
Domestic (US) Customers dial:
1-800-6-PARTS-7 (800-672-7877)
Fax your order in and qualify for a 2% Discount
on Standard orders for all orders which include
complete part numbers.*
Order via Phone:
Domestic (US) Dealers Call:
1-800-427-1244
Best Deal!
International Customers should contact
their local Multiquip Representatives for
Parts Ordering information.
Non-Dealer Customers:
Contact your local Multiquip Dealer for
parts or call 800-427-1244 for help in
locating a dealer near you.
Note: Discounts Are Subject To Change
Effective:
January 1
st
, 2006
NOTICE
All orders are treated as Standard Orders and will
ship the same day if received prior to 3PM PST.
PAGE 4 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
SAFETY INFORMATION
Do not operate or service the equipment before reading
the entire manual. Safety precautions should be followed
at all times when operating this equipment.
Failure to read and understand the safety
messages and operating instructions could
result in injury to yourself and others.
SAFETY MESSAGES
The four safety messages shown below will inform you
about potential hazards that could injure you or others. The
safety messages specifically address the level of exposure
to the operator and are preceded by one of four words:
DANGER, WARNING, CAUTION or NOTICE.
SAFETY SYMBOLS
DANGER
Indicates a hazardous situation which, if not avoided,
WILL result in DEATH or SERIOUS INJURY.
WARNING
Indicates a hazardous situation which, if not avoided,
COULD result in DEATH or SERIOUS INJURY.
CAUTION
Indicates a hazardous situation which, if not avoided,
COULD result in MINOR or MODERATE INJURY.
NOTICE
Addresses practices not related to personal injury.
Potential hazards associated with the operation of this
equipment will be referenced with hazard symbols which
may appear throughout this manual in conjunction with
safety messages.
Rotating parts hazards
Symbol Safety Hazard
Electric shock hazards
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 5
GENERAL SAFETY
CAUTION
NEVER operate this equipment without proper protective
clothing, shatterproof glasses, respiratory protection,
hearing protection, steel-toed boots and other protective
devices required by the job or city and state regulations.
Avoid wearing jewelry or loose fitting clothes that may
snag on the controls or moving parts as this can cause
serious injury.
NEVER operate this equipment when not
feeling well due to fatigue, illness or when
under medication.
NEVER operate this equipment under the
influence of drugs or alcohol.
ALWAYS clear the work area of any debris, tools, etc.
that would constitute a hazard while the equipment is
in operation.
No one other than the operator is to be in the working
area when the equipment is in operation.
DO NOT use the equipment for any purpose other than
its intended purposes or applications.
NOTICE
This equipment should only be operated by trained and
qualified personnel 18 years of age and older.
Whenever necessary, replace nameplate, operation and
safety decals when they become difficult read.
Manufacturer does not assume responsibility for any
accident due to equipment modifications. Unauthorized
equipment modification will void all warranties.
NEVER use accessories or attachments that are not
recommended by Multiquip for this equipment. Damage
to the equipment and/or injury to user may result.
ALWAYS know the location of the nearest
fire extinguisher.
ALWAYS know the location of the nearest
first aid kit.
ALWAYS know the location of the nearest phone or keep
a phone on the job site. Also, know the phone numbers
of the nearest ambulance, doctor and fire department.
This information will be invaluable in the case of an
emergency.
SAFETY INFORMATION
PAGE 6 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
SAFETY INFORMATION
PUMP SAFETY
DANGER
NEVER operate the equipment in an explosive
atmosphere or near combustible materials. An
explosion or fire could result causing severe
bodily harm or even death.
NEVER use pump for swimming pool dewatering applications.
This can result in electrical shock or electrocution.
WARNING
Accidental starting can cause severe injury
or death. ALWAYS place the ON/OFF
switch in the OFF position.
DO NOT place hands or fingers inside
pump when pump is running.
NEVER disconnect any emergency or
safety devices. These devices are intended for operator
safety. Disconnection of these devices can cause severe
injury, bodily harm or even death. Disconnection of any
of these devices will void all warranties.
CAUTION
DO NOT restrict the flow of the discharge hose as it may
cause overheating.
Be careful of discharge whipping under pressure.
NOTICE
ALWAYS place the pump in an upright position on a
platform before using. The platform will prevent the pump
frowm burrowing itself on soft sand or mud.
NEVER operate pump on its side.
DO NOT allow up to freeze in water.
NEVER leave an open pump chamber unattended.
ALWAYS keep the machine in proper running condition.
DO NOT attempt to thaw-out a frozen pump by using
a torch or other source of flame. Application of heat in
this manner may heat the oil in the seal cavity above the
critical point, causing pump damage.
DO NOT pump water greater than 104º F.
DO NOT pump liquids containing acid or alkali.
ALWAYS check strainer before pumping. Make sure
strainer is not clogged. Remove any large objects, dirt
or debris from the strainer to prevent clogging.
ALWAYS use a large basket strainer when pumping
water that contains large debris.
ALWAYS flush pump (clean) after use when pumping
water concentrated with heavy debris. It is very important
to always flush the pump before turning it off to prevent
clogging.
Fix damage to machine and replace any broken parts
immediately.
ALWAYS store equipment properly when it is not being
used. Equipment should be stored in a clean, dry location
out of the reach of children and unauthorized personnel.
NEVER lubricate components or attempt service on a
running machine.
ALWAYS allow the machine a proper amount of time to
cool before servicing.
Keep machine in proper running condition.
ELECTRICAL SAFETY
DANGER
The electrical voltage required to operate
pump can cause severe injury or even death
through physical contact with live circuits.
ALWAYS disconnect electrical power from
pump before performing maintenance on
pump.
NOTICE
ALWAYS
make certain that the voltage supplied to the
pump is correct. Always read the pump’s nameplate to
determine what the power requirements are.
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 7
Power Cord/Cable Safety
DANGER
NEVER let power cords or cables lay in water.
NEVER use damaged or worn cables or cords. Inspect
for cuts in the insulation.
NEVER grab or touch a live power
cord or cable with wet hands. The
possibility exists of electrical shock,
electrocution or death.
Make sure power cables are securely connected to the
motor's output receptacles. Incorrect connections may
cause electrical shock and damage to the motor.
WARNING
NEVER attempt to use the power cord as a lifting or
lowering device for the pump.
NOTICE
ALWAYS make certain that proper power or extension
cord has been selected for the job. See Cable Selection
Chart in this manual.
Grounding Safety
DANGER
ALWAYS make sure pump is grounded.
ALWAYS make sure that electrical circuits are properly
grounded to a suitable earth ground (ground rod) per
the National Electrical Code (NEC) and local codes
before operating generator. Severe injury or death by
electrocution can result from operating an ungrounded
motor.
NEVER use gas piping as an electrical ground.
LIFTING SAFETY
CAUTION
When raising or lowering of the pump is required, always
attach an adequate rope or lifting device to the correct
lifting point (handle) on the pump.
NOTICE
DO NOT lift machine to unnecessary heights.
NEVER lift the equipment while the engine is running.
TRANSPORTING SAFETY
NOTICE
ALWAYS shutdown pump before transporting.
ALWAYS tie down equipment during transport by
securing the equipment with rope.
ENVIRONMENTAL SAFETY
NOTICE
Dispose of hazardous waste properly.
Examples of potentially hazardous waste
are used motor oil, fuel and fuel filters.
DO NOT use food or plastic containers to dispose of
hazardous waste.
DO NOT pour waste, oil or fuel directly onto the ground,
down a drain or into any water source.
SAFETY INFORMATION
PAGE 8 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
SPECIFICATIONS
1. Motor Rotation – Upon start-up, the pump "kicks" in the opposite direction of motor rotation. The correct rotation is
counterclockwise (CCW) as viewed from the impeller end of the pump.
Table 1. Specifications
Model
Yellow Submarine
Type
Submersible Pump
Impeller
Plastic
Suction & Discharge Size
1.25 in. (31.75 mm)
Maximum Pumping Capacity
33 gallons/minute
(125 liters/minute)
Discharge Height
Above Pumping Level
5 ft (1.5 meters) 1,800 gallons/hr (6,814 liters)
10 ft (3.0 meters) 1,320 gallons/hr (4,997 liters)
15 ft (4.5 meters) 720 gallons/hr (2,725 liters)
20 ft (6.0 meters) 120 gallons/hr (454 liters)
Power
0.25 HP (0.37kw)
Voltage Phase
1Ø 115V
Starting Amps
11.5
Running Amps
2.3
Thermal Overlaod Protection
YES
Rotation
CCW
Power Cable Length
9.0 ft. (274 cm.)
Dimensions (Dia x Height)
6-1/4 in. (15.9 cm.) x 9.5 in. (24 cm.)
Dry Net Weight (Shipping)
8.5 lbs. (3.85 Kg.)
Dry Net Weight
6.0 lbs. 2.72 Kg.)
MQ YELLOW SUB. PUMP — SAFETY MESSAGE ALERT SYMBOLS
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 9
GENERAL INFORMATION
Introduction
The
MQ Model Yellow Submarine
submersible pumps is
designed to pump water and is used for the draining (dewatering)
of flooded rooms, drains and fill tanks, power fountains and
waterfalls swimming pool covers, and flat roofs.
A plastic impeller is attached to the output shaft of a 1/4 HP
electric motor which provides adequate power for general
purpose pumping. This submersible pump is supplied complete
with an electric power cable, and a discharge port located at the
top of the pump which accepts a 1-1/4-inch hose. For greater
versatility, the 1-1/4-inch NPT discharge port is equipped with a
garden hose adapter
This pump is ideal for portability because of its light weight and
carrying handle. In addition this pump will pump dry to 1/8-inch.
Built in overload protection protect the electric motor from
overheating.
The pump when in use, should be installed as free standing
(upright position) on its strainer base. A 1-1/4-inch discharge
hose (not supplied) should be connected to the discharge port
located on top of the pump. The discharge hose should be
adequately supported to avoid stress on the pump.
For maximum water flow, the discharge hose should be kept as
short as possible, and with minimum elevation above the pump.
Remember as the length and/or height of the discharge hose is
increased, the flow of water will be reduced. Also any reduction
in the hose size, and any fittings such as valves or outlet nozzles,
will restrict the water flow.
To avoid back-siphonage when the pump is switched off, ensure
that the end of the discharge hose is installed above the water
level at the final discharge point.
When the pump is switched off, the water remaining in the hose
will run back through the pump. This can be avoided by placing
a non-return valve in the hose nearest the pump.
NEVER use this submersible pump to pump flammable liquids
or operate in a explosive or flammable environment.
Avoid using this pump in conditions where mud, grit, silt or other
debris are present. These conditions could cause blockage and
cause excessive pump wear.
DO NOT install the pump directly into an area where there is a
heavy build-up of mud, grit, silt or debris. If this condition is present,
install the pump on a platform before operating.
This pump must always be positioned on a platform in an upright
position. NEVER operate the pump by a suspended rope. To
prevent large solids from entering the pump, install a wire mesh
screen or similar barrier around the pump.
If the pump was used to pump water containing mud, silt, use
clean water to flush out the pump after each use.
DO NOT allow the pump to run dry, as this will damage the
pump. During maintenance, dry running is permissible but only
for a few seconds.
NEVER lift the pump by its electrical power cord. ALWAYS lift
the pump by its carrying handle or attached a rope to carrying
handle.
A fully submerged pump in liquid will not freeze, unless the liquid
freezes. DO NOT allow a partially submerged pump to freeze.
The expansion of water freezing in the volute may crack the
pump, causing expensive repairs. If there is any danger of the
pump being subjected to freezing temperatures, Lift the pump
from water and allow it to drain thoroughly.
If the pump jams or the pump rotor locks for any reason,
disconnect the pump from the power source immediately.
Allowing the pump motor to cycle ON and OFF under an overload
condition can burn out the motor.
When replacement of nuts and bolts is required, use only
recommended parts as referenced in the parts section of this
manual. This pump uses
metric
threads. DO NOT use English
measurement threads.
PAGE 10 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
COMPONENTS
Figures 1 shows the location of the basic components, for the
MQ YELLOW SUBMARINE submersible pump. Listed below is
a brief explanation of each component.
1. Strainer Base – This strainer base is made of stainless
steel which is resistant to hardware corrosion. DO NOT
pump large objects or debris with this pump. This pump is
for pumping water only. For dewatering purposes, always
place the strainer base on a platform.
2. Volute/Impeller – Impellers are constructed of high-chrome
ductile iron to minimizes wear and prolong service life.
3. Electric Motor – This unit utilizes a single-phase, 115 V,
0.25 HP electric motor. Consult with a licenced electrician
before connecting motor to a power source. Observe all
city and local safety codes.
4. Discharge Port – Connect a 1-1/4-inch hose to this port.
Remember to adequately support the discharge hose to
avoid stress on the pump.
5. AC Power Cable – This unit is supplied with a 9.0 ft. (2.74
meters) AC power cable. Always check the cable for signs
of wear. NEVER! use a defective power cable. Replace the
cable immediately if the cable is worn or defective.
6. Carrying Handle – Always carry the submersible pump
by its handle. NEVER! carry the pump by its power cord.
Carrying or lifting the pump by the power cord, will cause
undue stress on the cord, and ultimately the cord will
become dislodged from the pump. See Table 3 for selecting
proper extension cord.
7. Thermal Overload Protection – This pump will require
the use of an external control box with a thermal overload
protection device that will shut down the motor in the event
of high operating temperatures. The motor will automatically
restart once the temperature returns to an acceptable
operating temperature.
8. Garden Hose Adapter – Connect a 3/4-inch diameter
garden hose to this adapter.
9. 3/4 NPT Fitting – Install this fitting into the discharge port
of the pump when using a 3/4-inch garden hose.
Figure 1. Submersible Pump Components
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 11
OPERATION
Operation
1. Attach a suitable lifting cable (rope) to the carrying handle
(Figure 2) on the pump and lower the pump into place. For
applications where there is an excessive amount of mud, grit
or silt, the use of a support platform is desirable. When
pumping water from swimming pool type applications where
there is little or no debris, the support platform is not required.
2. Make sure the pump is always placed in an upright position,
not tilted (Figure 3). Never position the pump directly on a soft,
loose bottom. Remember to attain maximum pumping ca-
pacity and prevent excessive wear, position the pump so it
will not burrow itself into sand or clay.
Figure 2. Submersible Pump Upright Position
(Correct)
Figure 3. Submersible Pump Upright Position
(Incorrect)
3. After the pump has been positioned correctly into place,
power can be applied to the pump's electric motor.
LIFTING
ROPE
1.25-INCH
DISCHARGE
HOSE
POWER
CORD
SUPPORT
PLATFORM
CARRYING
HANDLE
PAGE 12 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
4. NEVER! grab or touch a live power cord (Figure 4) with wet
hands, the possibility exists of
electrical shock
,
electrocu-
tion
and even
death
.
OPERATION
Figure 4. Power Cord (Wet Hands)
3. If all of the pump's electrical requirements have been met,
insert the power plug (Figure 5) on the pump into the power
source receptacle. Make sure the extension cord is of proper
size, see Table 3. It is
recommended
that the pump's power
cord be plugged into a
GFCI receptacle
to prevent the
possibility of
electrical shock
.
Pump Shut-Down/Clean-up
1. Remove the power from the pump by turning off the circuit
breaker or switch that provides power to the pump. Remem-
ber to make sure that hands are dry (not wet), and feet are not
standing in water when removing or disconnecting power
from the pump.
2. Using the lifting rope, lift the pump up from its current position.
Remove the discharge hose from the discharge port on the
pump.
3. If the pump was used to pump mud, grit or silt, flush vigorously
with clean water.
4. Remove the pump from the water. Wipe off any mud or debris
that might have attached itself to the pump.
5. Store pump in a clean dry place away from dirt and debris.
POWER
CORD
(POWER ON)
WET
HANDS
4. Wait a few seconds and water should begin to flow from the
discharge hose.
5. If water is not flowing from the discharge hose or not flowing
freely after a few minutes, remove the power from the pump
and check the system for leaks.
Figure 5. Connecting the Power
3-PRONG
PLUG
GFCI
RECEPTACLE
NEVER! grab or touch a live power cord. DO NOT stand in
water when connecting the pump's power cord into a voltage
source. The possibility exist of electrical shock, electrocution
and possibly
death!
DANGERDANGER
DANGERDANGER
DANGER
WARNINGWARNING
WARNINGWARNING
WARNING
NEVER
cut
or
remove
the ground prong from the pump's
AC power cord.
This pump is supplied with a grounding conductor and a
grounding-type attachment plug. To reduce the possibility
of electric shock, make certain that pump is connected only
to a properly grounded receptacle.
WARNINGWARNING
WARNINGWARNING
WARNING
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 13
TROUBLESHOOTING/CABLE
GNITOOHSELBUORTPMUP.2ELBAT
MOTPMYS MELBORPELBISSOP NOITULOS
tratSoTsliaFpmuP
?spma/egatlovtcerrocnI
ehtotdeilppusgniebsi)Ø1CAV511(egatlovreporptahtkcehC
tnerrucfotnuomaetauqedanasierehttahtkcehcoslA.pmu
p
.rekaerbtiucricecruosrewopkcehC.pmupehtnurot)spma(
?snoitcennoclacirtcelekcehC
.drocrewoptcepsnI
tiucricevitcefedroesufnwolB
?rekaerb
deppirtroesufnwolbfoesuackcehC.rekaerbtiucricroesufecalpeR
.rekaerbtiucric
?dekcolrellepmI
rellepmireporpmidnagniggolcrofkcehcdnadrocrewoptcennocsiD
.ecivednoitcetorpdaolrevokcehC.pmupgolcnU.ec
naraelc
?sgnidniwrotomteW
tsumecnatsisernoitalusnI.noitalusnirotomkcehcotretemitlumesU
elbmessasid,wolsiecnatsiserfI.smhoagem51yletamixorppaeb
.mehtyrdotsgnidniwekabdnarotompmup
pmupdnarotomevitcefeD
?sgniraeb
ecalpeR.sgniraebecalpernrowfi,raewgniraebevissecxerofkcehC
.evitcefedfirotom
lluFrevileDotsliaFpmuP
tuptuO
egrahcsiddetcirtserrodetsiwT
?esoh
.enilesohmorfgolcevomeR.deknik-nutalfesohyaL
?reniartspmupdeggolC .reniartsnaelC
?egatlovwoL
egatloV.dezigrenesipmupelihwegatlovkcehcotretemtlovaesU
nafI.)daoldnadaolon(ecruosrewopkcehC.%01±nihti
webtsum
gniyrrac-tnerrucetauqedasahtierusekam,desusidrocnoisnetxe
.htgnelderiuqerehtrofyticapac
?nrowrellepmI .rellepmiecalpeR
liOlaeSniretaW
?laeslacinahcemevitcefeD
.laeslacinahcemecalpeR
)noitarepOesahPelgniS,zH06(noitceleSelbaC.3elbaT
nitnerruC
serepmA
sttaWnIdaoLhtgneLelbaCelbawollAmumixaM
CAV511eriW01#eriW21#eriW41#eriW61#
5.2003.tf0001.tf006.tf
573.tf052
5006.tf005.tf003.tf002.tf521
5.7009.tf053.tf002.tf521.tf001
010021.tf052.tf051.tf001
510081.tf051.tf001.tf56
020042.t
f521.tf57.tf05
.egatlovwolmorftlusernacegamadtnempiuqE:NOITUAC
PAGE 14 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
PUMP ASSY.
4
1
2
3
5
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 15
PUMP ASSY.
NO. PART NO. PART NAME QTY. REMARKS
1 YS139495 CABLE 9 FT. 1
1 80000-002 CABLE 20 FT 1
2 YS137728 GARDEN HOSE ADAPTER 1
3 YS137727 FITTING, 3/4" NPT 1
4 YS020331 BUSHING YELLOW SUB 1
5 YS139492 STRAINER BASE 1
PUMP ASSY.
PAGE 16 — YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10)
Effective: February 22, 2006
TERMS AND CONDITIONS OF SALE — PARTS
PAYMENT TERMS
Terms of payment for parts are net 30 days.
FREIGHT POLICY
All parts orders will be shipped collect or
prepaid with the charges added to the invoice.
All shipments are F.O.B. point of origin.
Multiquip’s responsibility ceases when a
signed manifest has been obtained from the
carrier, and any claim for shortage or damage
must be settled between the consignee and
the carrier.
MINIMUM ORDER
The minimum charge for orders from Multiquip
is $15.00 net. Customers will be asked for
instructions regarding handling of orders not
meeting this requirement.
RETURNED GOODS POLICY
Return shipments will be accepted and
credit will be allowed, subject to the following
provisions:
A Returned Material Authorization 1.
must be approved by Multiquip prior to
shipment.
To obtain a Return Material Authorization, 2.
a list must be provided to Multiquip
Parts Sales that defines item numbers,
quantities, and descriptions of the items
to be returned.
The parts numbers and descriptions a.
must match the current parts price
list.
The list must be typed or computer b.
generated.
The list must state the reason(s) c.
for the return.
The list must reference the sales d.
order(s) or invoice(s) under
which the items were originally
purchased.
The list must include the name e.
and phone number of the person
requesting the RMA.
A copy of the Return Material Authorization 3.
must accompany the return shipment.
Freight is at the sender’s expense. All 4.
parts must be returned freight prepaid to
Multiquip’s designated receiving point.
Parts must be in new and resalable 5.
condition, in the original Multiquip
package (if any), and with Multiquip part
numbers clearly marked.
The following items are not returnable:6.
Obsolete parts. (If an item is in the a.
price book and shows as being
replaced by another item, it is
obsolete.)
Any parts with a limited shelf life b.
(such as gaskets, seals, “O” rings,
and other rubber parts) that were
purchased more than six months
prior to the return date.
Any line item with an extended c.
dealer net price of less than
$5.00.
Special order items.d.
Electrical components.e.
Paint, chemicals, and lubricants.f.
Decals and paper products.g.
Items purchased in kits.h.
The sender will be notified of any material 7.
received that is not acceptable.
Such material will be held for five 8.
working days from notification, pending
instructions. If a reply is not received
within five days, the material will be
returned to the sender at his expense.
Credit on returned parts will be issued 9.
at dealer net price at time of the original
purchase, less a 15% restocking
charge.
In cases where an item is accepted, for 10.
which the original purchase document
can not be determined, the price will be
based on the list price that was effective
twelve months prior to the RMA date.
Credit issued will be applied to future 11.
purchases only.
PRICING AND REBATES
Prices are subject to change without prior
notice. Price changes are effective on a
specific date and all orders received on or
after that date will be billed at the revised price.
Rebates for price declines and added charges
for price increases will not be made for stock
on hand at the time of any price change.
Multiquip reserves the right to quote and
sell direct to Government agencies, and to
Original Equipment Manufacturer accounts
who use our products as integral parts of their
own products.
SPECIAL EXPEDITING SERVICE
A $35.00 surcharge will be added to the
invoice for special handling including bus
shipments, insured parcel post or in cases
where Multiquip must personally deliver the
parts to the carrier.
LIMITATIONS OF SELLER’S LIABILITY
Multiquip shall not be liable hereunder for
damages in excess of the purchase price of
the item with respect to which damages are
claimed, and in no event shall Multiquip be
liable for loss of profit or good will or for any
other special, consequential or incidental
damages.
LIMITATION OF WARRANTIES
No warranties, express or implied, are
made in connection with the sale of parts or
trade accessories nor as to any engine not
manufactured by Multiquip. Such warranties
made in connection with the sale of new,
complete units are made exclusively by a
statement of warranty packaged with such
units, and Multiquip neither assumes nor
authorizes any person to assume for it
any other obligation or liability whatever in
connection with the sale of its products. Apart
from such written statement of warranty,
there are no warranties, express, implied or
statutory, which extend beyond the description
of the products on the face hereof.
Effective: February 22, 2006
TERMS AND CONDITIONS OF SALE — PARTS
YELLOW SUBMARINE PUMP — OPERATION AND PARTS MANUAL — REV. #1 (03/22/10) — PAGE 17
NOTES
OPERATION AND PARTS MANUAL
Your Local Dealer is:
HERE’S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL
NUMBER ON-HAND WHEN CALLING
©
COPYRIGHT 2010, MULTIQUIP INC.
Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property
of their respective owners and used with permission.
This manual
MUST accompany the equipment at all times. This manual is considered a permanent part of the equipment and should remain with the unit if resold.
The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in
this manual are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifications, design or the information published
in this publication at any time without notice and without incurring any obligations.
UNITED STATES
Multiquip Corporate Office MQ Parts Department
18910 Wilmington Ave.
Carson, CA 90746
Contact: mq@multiquip.com
Tel. (800) 421-1244
Fax (800) 537-3927
800-427-1244
310-537-3700
Fax: 800-672-7877
Fax: 310-637-3284
Mayco Parts Warranty Department
800-306-2926
310-537-3700
Fax: 800-672-7877
Fax: 310-637-3284
800-421-1244, Ext. 279
310-537-3700, Ext. 279
Fax: 310-537-1173
Service Department Technical Assistance
800-421-1244
310-537-3700
Fax: 310-537-4259 800-478-1244 Fax: 310-631-5032
MEXICO UNITED KINGDOM
MQ Cipsa Multiquip (UK) Limited Head Office
Carr. Fed. Mexico-Puebla KM 126.5
Momoxpan, Cholula, Puebla 72760 Mexico
Tel: (52) 222-225-9900
Fax: (52) 222-285-0420
Unit 2, Northpoint Industrial Estate,
Global Lane,
Dukinfield, Cheshire SK16 4UJ
Contact: sales@multiquip.co.uk
Tel: 0161 339 2223
Fax: 0161 339 3226
CANADA
Multiquip
4110 Industriel Boul.
Laval, Quebec, Canada H7L 6V3
Contact: jmartin@multiquip.com
Tel: (450) 625-2244
Tel: (877) 963-4411
Fax: (450) 625-8664
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

MQ Multiquip MQ-YELLOW-SUBMARINE Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI