1. Introducon .......1
1.1 Objecve
1.2 Specificaon
2. Safety .......2
2.1 Safety Regulaons
2.2 Electrical Safety & Shock
2.3 Ground Protecon
2.4 Environmental Condions
2.5 Cleaning
2.6 Usage Cauon
3. System Configuraon .......5
3.1 Tele-ECG Configuraon
3.2 Tele-ECG Machine
3.3 Electrode Placement
3.4 Applicaon For Mobile
3.5 Applicaon For Laptop
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
1
1. Introducon
1.1 Objecve
This user manual is intended to acquaint and assist the user with
Sanjeevani's ACE, a Tele-ECG system. User instrucons, warning and
cauon noces may carefully be noted for safe and effecve operaon
of the unit.
1.2 Specificaon
Principle
Bio-potenal sensing by surface electrodes.
Configuraon
Einthoven12 Leads, Simultaneous.
Input Impedance
> 10 MΩ
Gain (User Selectable)
1, 2, 3, 4, 6, 8 &12.
Frequency
(User Selectable)
0.05-150 Hz,
0.05/0.5-40Hz,
0.05/0.5-25Hz.
CMRR
> 90 dB
Connecvity
Mobile-Mobile via GPRS,
Mobile-PC Apps via internet.
Unit-Mobile/PC via Bluetooth.
Size
3.5”(L) x 2.5”(B) x 1.0”(H) inches.
Mode
Test/ECG.
Power Input
BL-5CB 800mAh 3.7V 3.0Wh (Li-ion) or BL-4C,
860mAh.
Weight
83 gms.
Sanjee
ElectroMedicals
ni
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
2
2. Safety
WARNING sign indicates a potenal hazard or unsafe pracce which, if
not avoided, can result in mortality or morbidity.
CAUTION sign indicates a potenal hazard or unsafe pracce which, if
not avoided, can result in minor personal injury or product/property
damage.
SANJEEVANI's ACE is baery operated. It does not lead to any harm or
discomfort to subject/paent. It has all the safety features provided by
IEC60601-1 Operator should however make sure that the baery .
charger is disconnected from the mains before using the ACE on the
subject/paent.
2.1 Safety Regulaon
In order to ensure correct use of machine without any risk, all
precauons and warnings should be carefully followed. Refraining
from this may cause damage to machine and can be risky to the
paent/operator.
To receive informaon on the service system and on prevenve
maintenance contracts, please contact Sanjeevani Electromedicals.
Before using the machine, the user must check the machine for proper
funcon. Parcular aenon must be paid to a visual check of LEDs.
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
3
The manufacturer and installaon personnel disclaim any
responsibility on the operaon in the following cases:
Ÿ ·Spare parts have not been replaced with original spare parts like
Baery, Charger & ECG Cable.
Ÿ ·The equipment is not used according to the safety regulaons.
Ÿ 2.2 Electrical Safety & Shock
Ÿ ·Check the mains supply before connecng the device for charging.
Ÿ ·Before connecng other accessories make sure that the power
supply is disconnected and usual precauons have been taken.
Ÿ During all service operaons that require the disconnecon from
electric power, pay maximum aenon to electric shock risks.
Ÿ WARNING: DO NOT USE THE DEVICE WHILE CHARGING.
Ÿ 2.3 Ground Protecon
Ÿ The electric system of the rooms where the device is charged
should comply with the safety regulaons.
Ÿ 2.4 Environmental Condions
Ÿ ·The temperature of the room for the perfect working of the
equipment is in the range of 15°C to 50° C.
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
4
Ÿ Humidity must be non-condensing and in the range of 10 % to 98 %.
Ÿ 2.5 Cleaning
Ÿ Stop the machine before any cleaning operaon.
Ÿ Clean using coon cloth and non-abrasive cleansers.
Ÿ Do not use organic solvents or agents containing any kind of
solvent. Do not use aerosols (sprays), as the cleanser must not in
any circumstance enter the device.
Ÿ To sterilize the surfaces, aldehyde-based soluons mixed with
water are recommended.
Ÿ 2.6 Usage Cauon
Ÿ Ensure that your android mobile/laptop is connected to the right
ACE device by verifying the Serial No.
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
5
3. System Configuraon
3.1 Tele-ECG Configuraon
Tele-ECG machine can be interfaced with the applicaon soware
installed on Mobile (android)/Laptop via Bluetooth.
3.2 Tele-ECG Machine
1
5
4
2
3
6
Bluetooth Indicator
(RED LED)
Reset Button
Power Button
ON/OFF Indicator
(LED)
Battery Charging
Charging Indicator (LED)
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
6
Refer Fig. (a), (b) & (c):
1. Bluetooth Indicator (LED) - Starts blinking once it is ready to
connect and turns OFF
once it gets connected.
2. Charging Indicator (LED) - Turns Red while charging & turns
Green when charged fully.
3. Baery Charging (USB Port)
4. ON/OFF Indicator (LED) - Turns Green when Power Buon is
pressed & held for 5 secs
and Red when baery is low.
5. Power Buon – For switching the device ON / OFF.
6. Reset Buon – If the device hangs then press Reset Buon with
pin.
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
7
3.3 Electrode Placement
12 lead ECG is recorded by placing 10
electrodes, comprising 6 chest electrodes
and 4 limb
electrodes as shown in following figure.
Six chest electrodes are numbered as V1 to V6.
They are posioned in specific posions on the
rib cage. V1and V2 are placed on the right and
le side of the sternum respecvely in the
fourth
inter-costal space. The posion for V4 is in the
5th inter-costal space, in line with the middle
of
the clavicle (mid-clavicular). V3 sits midway
between V2 and V4. V5 is placed in the 5 th
inter-
costal space in line with beginning of le axilla.
V6 is placed in the same intercostals space in
mid axillary line. Limb leads are placed on the
four extremies right arm (Red), le arm
(Yellow), right leg (Black) and le leg (Green).
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
8
3.4 Applicaon For Mobile
STEP 1: Press & Hold the Power Buon of the Tele-ECG Device ll the
ON/OFF LED turns
Green & Bluetooth LED starts blinking at constant rate.
STEP 2: Click on ACE Tele-ECG app in your mobile to get the following page.
Click here to load previously saved ECG.
Click here to take new ECG.
1 lead
3 leads
6 leads
12 leads
OK
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
9
STEP 3: Aer clicking on New, the applicaon will ask for Bluetooth
Connecvity.
STEP 4: Once the device gets connected via Bluetooth (verify serial
number of the device), the
12CH. TELE ECG wants to turn on Bluetooth.
Deny
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
10
STEP 5: Click on the OPTION to get the following options.
Mode: Two Modes are available, ECG & Test mode.
Select ECG mode to take new ECG OR Test mode to check proper
funconing of device.
Filter: Adjust the filter frequency range if required (By default it is set to 0-
150 Hz).
Gain: Adjust the gain if required (By default it is set to 6 equal to
convenonal gain of 1).
Back to Main Page: It will redirect you to first page
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
11
STEP 6: Aer selecng the Mode, Filter & Gain, click on START to get
the following screen (Test & ECG respecvely). You can stop
acquision aer 13 seconds by clicking STOP.
STEP 7: Select Generate Report by clicking on OPTION.
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
1
STEP 8: Proceed to Save the ECG Report by following the steps
ECG Report can be saved in Image/PDF/Text
You can protect the Report with password.
Fill in the Paent Details & click on Save.
Do you want to set password to pdf
file?
NO YES
Save Data as...
IMAGE
PDF
DATA IN TEXT FILE
OK
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
12
Insert Comment if required.
Click Yes to view Report.
3.5 Applicaon For Laptop
STEP 1. Turn on Bluetooth, Add ACE Tele-ECG & Pair it.
( Click on START Sengs Devices Turn on Bluetooth
Add Bluetooth or Other Devices Bluetooth, now following screen will
appear )
View Report?
NO YES
NO YES
Do you want to insert comment?
(Upto 155 characters)
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
USER MANUAL
13
STEP 2. Check the ports from Device Manager.
(Click on START Type Device Manager in search box Ports )
USER MANUAL
USER MANUAL
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
Sanjee
ElectroMedicals
ni
STEP 7. Fill in Paent Details, adjust the system seng accordingly and
click SAVE.
STEP 8. Lead Status will indicate if any of the lead is connected/not
connected. Red Indicates
lead not connected (reconnect the lead and proceed further) &
Green indicates lead connected.
15
USER MANUALUSER MANUALUSER MANUALUSER MANUAL
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
Sanjee
ElectroMedicals
ni
STEP 3. Open Tele-ECG App on Laptop.
STEP 4. Insert the port no. and connect.
STEP 5. Instrument connected successfully (Ensure that the Bluetooth
Red LED turns OFF in
Tele ECG device, else try with another port no.)
STEP 6. Click on SETTINGS.
14
USER MANUAL
Sanjee
ElectroMedicals
ni
Accurate, Connected, Easy.
www.sanjeevanielectromedicals.com
STEP 9. Click on START.
STEP 10. Click on STOP & then on REPORT (Minimum ACQ Time
to generate Report is 13s)
STEP 11. Print/Save ECG Report.
STEP 12.
You can send
this report to
the expert by
E-mail or
WhatsApp or
any other
media sharing
service for his
opinion.
16
Sanjee
ElectroMedicals
ni
WARRANTY CARD
SANJEEVANI ELECTROMEDICALS
(Technology by BARC)
MODEL NO. : TE17BT2
SERIAL NO. :
Dear Customer,
Thank You and Congratulaons on purchasng ACE TELE-ECG product.
This product is under warranty from any manufacturing defects for 12 months
from date of your purchase.
This warranty is valid only when,
1. The product has not been opened or tempered by any unauthorized person.
2. The warranty card duly signed and copy of invoice are presented with the
faulty unit.
3. The product has been installed, used and maintained strictly in accordance
with the instrucon manual.
Warranty does not apply for,
1. For any accessories other than the device
2. Use of parts/accesories not provided or supported by ACE TELE-ECG.
3. Damage resulng from accidental,mishandling or negligence on part of the
user and incorrect line voltage.
Consequenal Damage
Liability for consequenal loss or damage is neither accepted nor implied.
SANJEEVANI ELECTROMEDICALS
OFFICE-13, FIRST FLOOR,
LAKHANI PALMVIEW, PLOT NO. 12,
SECTOR 48,NERUL (W),
NAVI MUMBAI - 400706.
DEALER’S STAMP & ADDRESS
DATE OF PURCHASE
_ _ _ _ _ _ _ _ _ _ _ _ _
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

ACE Tele-ECG User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI