Christie Crimson WU25 Technical Reference

Type
Technical Reference

This manual is also suitable for

Christie Crimson WU25

The Christie Crimson WU25 is a high-performance 3DLP laser projector designed for large venues and demanding applications. With its powerful illumination system and advanced optical design, the Crimson WU25 delivers stunning visuals with exceptional brightness, color accuracy, and contrast.

Key features include:

  • True 4K resolution: Experience razor-sharp images and immersive viewing with 4096 x 2160 resolution.
  • High brightness: Delivering up to 27,000 lumens, the Crimson WU25 ensures vibrant and captivating projections even in well-lit environments.
  • Wide color gamut: The projector supports Rec. 2020 color space, providing a wider range of colors for lifelike and realistic visuals.

Christie Crimson WU25

The Christie Crimson WU25 is a high-performance 3DLP laser projector designed for large venues and demanding applications. With its powerful illumination system and advanced optical design, the Crimson WU25 delivers stunning visuals with exceptional brightness, color accuracy, and contrast.

Key features include:

  • True 4K resolution: Experience razor-sharp images and immersive viewing with 4096 x 2160 resolution.
  • High brightness: Delivering up to 27,000 lumens, the Crimson WU25 ensures vibrant and captivating projections even in well-lit environments.
  • Wide color gamut: The projector supports Rec. 2020 color space, providing a wider range of colors for lifelike and realistic visuals.
Technical Reference
020-102661-04
Crimson and Crimson Mirage
Status System
NOTICES
COPYRIGHT AND TRADEMARKS
Cop
yright
©
2020 Christie Digital Systems USA Inc. All rights reserved.
All brand names and product names are trademarks, registered trademarks or trade names of their respective holders.
GENERAL
Every effort has been made to ensure accuracy, however in some cases changes in the products or availability could occur which may not be reflected in this
document. Christie reserves the right to make changes to specifications at any time without notice. Performance specifications are typical, but may vary
depending on conditions beyond Christie's control such as maintenance of the product in proper working conditions. Performance specifications are based on
information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied
warranties of fitness for a particular purpose. Christie will not be liable for errors contained herein or for incidental or consequential damages in connection
with the performance or use of this material. Manufacturing facilities in Canada and China are ISO 9001 certified. Manufacturing facilities in Canada are also
ISO 14001 certified.
WARRANTY
Products are warranted under Christie’s standard limited warranty, the complete details of which are available by contacting your Christie dealer or Christie. In
addition to the other limitations that may be specified in Christie’s standard limited warranty and, to the extent relevant or applicable to your product, the
warranty does not cover:
a.
Problems or damage occurring during shipment, in either direction.
b.
Problems or damage caused by combination of a product with non-Christie equipment, such as distribution systems, cameras, DVD players, etc., or use
of a product with any non-Christie interface device.
c.
Problems or damage caused by misuse, improper power source, accident, fire, flood, lightning, earthquake, or other natural disaster.
d.
Problems or damage caused by improper installation/alignment, or by equipment modification, if by other than Christie service personnel or a Christie
authorized repair service provider.
e.
Use of third party product enclosures for environmental protection during outside use must be approved by Christie.
f.
Problems or damage caused by use of a product on a motion platform or other movable device where such product has not been designed, modified or
approved by Christie for such use.
g.
Except where the product is designed for outdoor use, problems or damage caused by use of the product outdoors unless such product is protected from
precipitation or other adverse weather or environmental conditions and the ambient temperature is within the recommended ambient temperature set
forth in the specifications for such product.
h.
Defects caused by normal wear and tear or otherwise due to normal aging of a product.
The warranty does not apply to any product where the serial number has been removed or obliterated. The warranty also does not apply to any product sold
by a reseller to an end user outside of the country where the reseller is located unless (i) Christie has an office in the country where the end user is located or
(ii) the required international warranty fee has been paid.
The warranty does not obligate Christie to provide any on site warranty service at the product site location.
PREVENTATIVE MAINTENANCE
Preventative maintenance is an important part of the continued and proper operation of your product. Failure to perform maintenance as required, and in
accordance with the maintenance schedule specified by Christie, will void the warranty.
REGULATORY
The product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the product is operated in a commercial environment. The product generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of the product in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at the user’s own expense. Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment
CAN ICES-3 (A) / NMB-3 (A)
기기는 업무용(A)으로 전자파적합등록을 기기이오니 판매자 또는 사용자는 이점을 주의하시기 바라며, 가정 외의 지역에서 사용하는 것을 목적으로 합니다.
ENVIRONMENTAL
The product is designed and manufactured with high-quality materials and components that can be recycled and reused. This symbol
means that electrical
and electronic equipment, at their end-of
-life, should be disposed of separately from regular waste. Please dispose of the product appropriately and according
to local regulations. In the European Union, there are separate collection systems for used electrical and electronic products. Please help us to conserve the
environment we live in!
Content
Crimson
status system..............................................4
Model name.......................................................4
Product documentation................................................4
Related documentation..............................................5
Status system states.................................................5
Configuration Group (SST+CONF?)........................................ 5
System Group (SST+SYST?)............................................ 6
Signal Group (SST+SIGN?)............................................ 12
Light Group (SST+LGHT?).............................................13
Version Group (SST+VERS?)........................................... 15
Cooling Group (SST+COOL?)........................................... 17
Temperature Group (SST+TEMP?)........................................20
Serial Group (SST+SERI?).............................................23
Crimson and Crimson Mirage Technical Reference–Status System 3
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Crimson status system
This guide contains information about the v
alues and fault conditions that can be reported by the
status system on Crimson devices.
The status system provides an overview of the device at the current point in time. It contains a
number of groups, which contain a set of status items. Each status item represents a component or
sub-component of the system. Obtain specific details regarding a warning or error for a status item
using the log system.
The numbers next to the status items in this guide correspond directly to the status item index within
each group.
Model name
Crimson HD25
Crimson WU25
Crimson HD31
Crimson WU31
Mirage HD25
Mirage WU25
Product documentation
For installation, setup, and user information, see the product documentation available on the Christie
Digital Systems USA Inc. website. Read all instructions before using or servicing this product.
Crimson HD25, Crimson WU25, Crimson HD31, Crimson WU31
1. Access the documentation from the Christie website:
Go to this URL:bit.ly/2nOplCa.
Scan the QR code using a QR code reader app on a smartphone or tablet.
2. On the product page, select the model and switch to the Downloads tab
.
Crimson and Crimson Mirage Technical Reference–Status System 4
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Mirage HD25, Mirage WU25
1. Access the documentation from the Christie website:
Go to this URL:bit.ly/2C6H4HZ.
Scan the QR code using a QR code reader app on a smartphone or tablet.
2. On the product page, select the model and switch to the Downloads tab
.
Related documentation
Additional information on the projector is available in the following documents.
Crimson and Mirage Installation and Setup Guide (P/N: 020-102647-XX)
Crimson and Mirage User Guide (P/N: 020-102649-XX)
Crimson and Mirage Product Safety Guide (P/N: 020-102648-XX)
Crimson and Mirage Specifications Guide (P/N: 020-102724-XX)
Crimson and Mirage Service Guide (P/N: 020-102733-XX)
Crimson and Mirage Serial Commands Guide (P/N: 020-102660-XX)
Status system states
The status system has three states to indicate the health of the device.
OK No known issue
Warning A problem with this item should be addressed.
Error A problem with this item prevents the projector from properly
displa
ying video or turning on the projector.
Configuration Group (SST+CONF?)
The Configur
ation Group provides values and fault conditions for configuration-related items in
Crimson.
# Status State Value Description
0 Projector Model <projector model> Displays the model for the Crimson
projector
.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 5
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Unknown Cannot retrieve the model information.
Jig Mode Reserved for engineering use.
1 Projector S/N <serial number> Displays the serial number of the
projector
.
Unknown The storage device containing the
information is inaccessible or the data on
the device is corrupted.
2 Output Resolution <horizontal>x<vertical> Displays the native output resolution of
the projector
.
3 Projector Build Date
<YYYY>/<MM>/<DD> Displays the build date of the projector.
Unknown The storage device containing the
information is inaccessible or the data on
the device is corrupted.
System Group (SST+SYST?)
The S
ystem Group provides values and fault conditions relating to the system and its health for
Crimson.
# Status State Value Description
0 Projector Hours <hours>:<minutes> Displays the total amount of time that
the projector has been on (including
w
arm up and cool down times).
This does not include the amount of time
required to cool down the electronics
when turning off the Keep Electronics on
in Standby option while the projector is
already in standby.
N/A Cannot retrieve or update the value.
1 Pitch/Roll <pitch value>/<roll
v
alue>
Provides the physical orientation of the
projector:
• A negative pitch means that the
projector is pointing down.
• A negative roll means the projector
is tilted counter clockwise as seen
from the rear.
Communication Fault Information is not available due to a
hardw
are fault.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 6
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
5
6
7
8
Lens Motor Horizontal-Axis
Lens Motor V
ertical-Axis
Lens Motor Zoom- Axis
Lens Motor Focus- Axis
Calibrating Currently calibrating the lens motor.
Calibrated The motor range has been properly
calibr
ated.
Unknown The status of the motor is unknown
because a problem occurred in the
upstream communication path.
Uncalibrated The range for the current lens has not
been determined and/or the reported
position on the axis ma
y be inaccurate.
Failed During reset or calibration, an error was
detected related to the motor and/or
sensor
.
9 Built-In Self Test
N/A The built-in self test has not been
ex
ecuted yet.
Passed The built-in self test completed
successfully
.
Failed The built-in self-test failed.
10 System ID Board OK The device has been properly detected
and initializ
ed.
Unknown The status of the device is unknown.
Communication Fault Cannot communicate with the device.
Invalid Data The information on the device is missing
or corrupted.
11 Housekeeping Board OK The device has been properly detected
and initializ
ed.
Unknown The status of the device is unknown.
Communication Fault The device failed to respond or provided
a bad response to a command while the
light source is on.
The projector remains on until AC power
is remo
ved, even if this warning
condition is fixed.
Detection Fault Cannot read the device hardware
information.
Initialization Fault Cannot properly initialize the device.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 7
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Communication Fault The device failed to respond or it
pro
vided a bad response to a command
while the projector is in standby mode.
12 Keypad Display
Auto Detect The projector is attempting to detect the
presence of the k
eypad display device.
Programming Programming the device with the correct
firm
ware.
OK The device has been properly detected
and initializ
ed.
Detection Fault Cannot detect the keypad display device.
Unexpected Behavior The device is not responding correctly.
Upgrade Failed The device failed to upgrade properly.
13 Power Supply OK The power supply has been properly
detected and initializ
ed.
Unknown The status of the power supply is
unknown due to an upstream
communication fault.
Fan Problem The power supply reports a fan failure
but no o
ver temperature shutdown or
high temperature alarm is reported.
Overtemperature The power supply reports a high
temper
ature alarm but reports no fan
failure.
Overtemperature/Fan
Problem
The power supply reports both a high
temper
ature alarm and a fan failure.
Communication Fault Communication either timed out or an
error occurred in the tr
ansmission/
reception of data.
Detection Fault Communication timed out at startup.
Overvoltage Detected The power supply reports an over
v
oltage shutdown condition.
Overcurrent Detected The power supply reports an over
current shutdown condition.
Overtemperature The power supply reports an over
temper
ature shudown.
Overtemperature/Fan
Problem
The power supply reports an over
temper
ature shutdown and fan failure.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 8
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Control Fault The power supply reports an internal
circuit failure.
AC Input Low The power supply reports the AC input is
too low for full power mode.
27 Power Supply Input Voltage Limited Mode The AC power cable is plugged into inlet
2.
Full Mode The AC power cable is plugged into inlet
1.
29 Lens ID Detected The lens was detected.
Unknown The communication path to the lens is
not working; therefore, the state is
unknown.
Not Detected Cannot detect the lens.
30 Main Control Board OK The main control board has been
initializ
ed at least once and is known to
be OK.
Unknown The main control board status is
unknown because it has not been
powered up y
et.
Initialization Fault Cannot successfully program the main
control board.
32 Power Supply Output Voltage <voltage>V Displays the output voltage reading
when the housek
eeping board (HKB) is
ready.
Unknown The status of this output is unknown
because the power supply cannot be
communicated with.
46 Status LED Board OK The status of the status LED board (SLB)
is OK.
Unknown Cannot determine the status of the
status LED board (SLB) because the
backpane (C4BP) is nonfunctional.
Communication Fault Cannot communicate with the status LED
board (SLB).
47 Side Panel NFCT OK The side panel near field communication
tag (NFCT) is OK.
Unknown The side panel near field communication
tag (NFCT) status is unknown because
the integr
ated keypad board (IKB) is
non-functional.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 9
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Not Detected Cannot write to or read from the side
panel near field communication tag
(NFCT).
48 Backplane OK The backplane has been properly
detected and initializ
ed.
Detection fault Cannot read the backplane hardware
information.
Initialization fault Cannot properly initiate the backplane.
Runtime fault The backplane experienced an
unreco
verable failure during runtime.
49 Image Processor
Off The image processor is in standby
without an
y cached errors or warnings.
OK The image processor has been properly
detected and initializ
ed.
Unknown Cannot determine the image processor
status due to an upstream issue.
Detection fault Cannot read the image processor
hardw
are information.
Initialization fault Cannot properly initialize the image
processor
.
Runtime fault The image processor experienced an
unreco
verable failure during runtime.
50
51
52
Formatter-Red
Formatter-Green
Formatter-Blue
Off The formatter is in standby without any
cached errors or w
arnings.
OK The formatter has been properly
detected and initializ
ed.
Unknown Cannot determine the formatter status
due to an upstream issue.
Power Bad The formatter detected an unexpected
power glitch and has started the process
of parking the DMD
. This is often
recoverable.
Detection Fault Cannot read the formatter hardware.
Initialization Fault Cannot properly initialize the formatter.
Runtime Fault The formatter experienced an
unreco
verable failure during runtime.
54
55
Option Card 1
Option Card 2
Off The option card is in standby without
an
y cached errors or warnings.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 10
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
OK The option card has been properly
detected and initializ
ed.
Not Present An option card is not installed in this
slot.
Unknown Cannot determine the option card status
due to an upstream issue.
Detection fault Cannot read the option card hardware
information.
Initialization fault Cannot properly initialize the option
card.
Runtime fault The option card experienced an
unreco
verable failure during runtime.
85 Color Sensor Board
OK The device has been properly detected
and initializ
ed.
Unknown The status of the device is unknown.
Communication Fault Cannot communicate with the device.
Detection Fault Cannot detect the color sensor board.
Initialization Fault Cannot properly initialize the color
sensor board.
113 Combine ID Board OK The device has been properly detected
and initializ
ed.
Unknown The status of the device is unknown.
Not Detected Cannot detect the device.
Initialization Fault Cannot initialize the device.
Communication Fault Cannot communicate with the device.
114 Combiner Driver OK The combiner has been properly
detected and oper
ating correctly.
N/A The status of the combiner is not
a
vailable.
Upgrading The combiner is in the process of a
firm
ware upgrade.
Do not turn off the projector while the
upgrade is occurring.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 11
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
The upgrade should not take longer than
one minute and occurs immediately
following a main system softw
are
upgrade.
Detection Fault Cannot detect the combiner.
Upgrade Failure Cannot upgrade the combiner firmware.
The projector will not turn on.
Signal Group (SST+SIGN?)
The Signal Group pro
vides values and fault conditions relating to the video signal status for Crimson.
# Status State Value Description
0
11
12
13
14
21
22
23
24
HDBaseT Input
Card 1 - Input 1
Card 1 - Input 2
Card 1 - Input 3
Card 1 - Input 4
Card 2 - Input 1
Card 2 - Input 2
Card 2 - Input 3
Card 2 - Input 4
Not Present Either the card is not present or the card
does not ha
ve a single input port.
<input type> (No Signal) No signal is detected.
Where <input t
ype> : {DP, HDMI, DVI,
3G-SDI}
<input type>, <active
window>@ <v
-sync rate>
(<status>)
Where
<input type> : {DP, HDMI, DVI, 3G-
SDI}
<active window> :
<columns>x<rows>
<v-sync rate> : the input frame rate,
in Hz (##.##Hz)
<status> : {“Master”, “No signal”,
“Inactive”, “Locked”}
<input type> <active window>
@ <v
-sync rate> (<status>)
Where
<input type> : {DP, HDMI, DVI, 3G-
SDI}
<active window> :
<columns>x<rows>
<v-sync rate> : the input frame rate,
in Hz (##.##Hz)
<status> : {“Unlocked”, “Out of
phase”}
50 Output Frequency
<rate>Hz Where <rate> : the output frame rate,
in Hertz
If the input frequency does not match
the output frequency
, Free Running @
XX.YYHz is displayed.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 12
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
N/A No video is being displayed.
51 Frame Locked N/A No video is being displayed or an
internal test pattern is being displa
yed.
Locked The output is locked to the selected
input(s).
Unlocked The output is not locked to the selected
input(s).
52 3D Sync N/A There is no 3D signal or 3D mode is set
to Off
.
Valid 3D Sync Detects a valid external 3D sync.
Internal 3D Sync The system is using the internal v-sync
signal because the video is configured as
a Dual-
Input. External sync is ignored.
Valid HDMI 3D Sync Properly detects the built-in HDMI 3D
sync signal.
Invalid 3D Sync (using internal
sync)
Detects an external 3D sync but it is not
lock
ed and/or in phase with the 3D video
signal(s). The system is using the
internal v-sync signal instead but may
have L/R swapped.
No 3D Sync (using internal sync) Cannot detect an external 3D sync. The
system is using the internal v
-sync
signal instead but may have L/R
swapped.
53 TSIC Connection
Alias IP: <IP address> Displays the IP address used to
communicate with the projector through
the SDV
oE network.
N/A Either the card is not present or is not
powered.
Light Group (SST+LGHT?)
The Light Group pro
vides values and fault conditions relating to the light source status for Crimson.
# Status State Value Description
0 Combiner State On The combiner is on.
Off The combiner is off.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 13
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Warming Up The combiner is in the process of turning
on.
Cooling Down The combiner is in the process of cooling
down.
Overtemperature The combiner has turned off due to the
thermal fuse being tripped.
Overcurrent Detected The combiner has turned off due to over
current protection.
Initialization Fault The combiner has turned off
unexpectedly during while the projector
is w
arming up/initializing..
Runtime Fault The combiner has turned off
unexpectedly while in the projector is
on.
1 Combiner Hours <hours>:<minutes> (h:m) Displays the total amount of time that
the combiner has been on.
Unknown The combiner hours are unknown
because the combiner cannot be
communicated with.
228
229
230
231
232
237
242
247
Diode current (Red1)
Diode current (R
ed2)
Diode current (Red3)
Diode current (Red4)
Diode current (Green
+Red A)
Diode current (Green
+Red B)
Diode current (Green
+Red C)
Diode Current (Blue)
<current>mA Displays the current being drawn by the
diode(s).
Unknown Cannot retrieve the value due to a
communication error with the combiner
firm
ware.
Off The diode(s) is currently off.
251 Combiner TEC Current <current>mA Displays the current being drawn by the
thermal electric cooler (TEC).
Unknown Cannot retrieve the value due to a
communication error with the combiner
firm
ware.
Off The thermal electric cooler (TEC) is not
running.
Detection Fault Cannot detect a current. It appears the
TEC connector is unplugged.
252 Combiner Phosphor
Wheel
<RPM>RPM Displays the phosphor wheel RPM.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 14
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Off The phosphor wheel is not spinning.
<RPM>RPM - Low RPM The combiner has shut down because
the phosphor wheel RPM is too low
.
253 Combiner Diffuser Wheel
<RPM>RPM Displays the diffuser wheel RPM.
Off The diffuser wheel is not spinning.
<RPM>RPM - Low RPM The combiner has shut down because
the diffuser wheel RPM is too low
.
254 Combiner
Communication
OK The combiner communication path is
good.
Communication Fault A communication failure has occurred
between one of the following:
The main software and the
combiner firmware
• The combiner fan board and the
driver board
• The combiner fan board and other
peripheral
Version Group (SST+VERS?)
The V
ersion Group provides values and fault conditions related to software and hardware versions for
Crimson.
# Status State Value Description
0 Main Control Board SW Version <version> Displays the software version
running on the main control
board.
Unknown Cannot determine the software
v
ersion information.
1 Main Control Board HW Version
<name>.<level>.<mod> <name> = Short name of the
board
<lev
el> = Version of the board
<mod> = Modification level of
the board
Detection Fault Cannot read the board type
information.
2 Backplane HW Version <name>.<level>.<mod> <name> = Short name of the
board
<lev
el> = Version of the board
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 15
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
<mod> = Modification level of
the board
This information is cached while
the projector is in standb
y.
N/A The backplane has never been
turned on or initializ
ed.
3 Image Processor HW Version
<name>.<level>.<mod> <name> = Short name of the
board
<lev
el> = Version of the board
<mod> = Modification level of
the board
This information is cached while
the projector is in standby.
N/A The image processor board has
nev
er been turned on or
initialized.
4
5
6
Formatter-Red HW Version
Formatter-Green HW Version
Formatter-Blue HW Version
<name>.<level>.<mod> <name> = Short name of the
board
<lev
el> = Version of the board
<mod> = Modification level of
the board
This information is cached while
the projector is in standby.
N/A The formatter has never been
turned on.
7
8
Option Card 1 HW Version
Option Card 2 HW V
ersion
<name>.<level>.<mod> <name> = Short name of the
board
<lev
el> = Version of the board
<mod> = Modification level of
the board
This information is cached while
the projector is in standby.
N/A The option card has never been
turned on or initializ
ed.
17 Power Supply HW Version
<hardware version>.<boot
v
ersion>.<main version>
<model>.<version>.<name>
<hardware version> = Hardware
version of power supply
<boot version> = Version of
power supply bootloader
<main version> = Version of
power supply main firmware
Unknown Cannot retrieve the hardware
v
ersion.
18 Housekeeping Board HW Version
<name>.<level>.<mod> <name> = Name of the board
(such as HKBC)
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 16
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
<level> = Hardware version of
the board
<mod> = Modification lev
el of
the board
Unknown Cannot retrieve the hardware
v
ersion.
19 Keypad Display HW Version
<name>.<level>.<mod> <name> = Name of the board
(such as IKB)
<lev
el> = Hardware version of
the board
<mod> = Modification level of
the board
Unknown The board is not ready yet so
the hardw
are version has not
been retrieved.
35 Combiner Driver HW Version
<version> Displays the hardware version of
the combiner fan.
Unknown Cannot retrieve the hardware
v
ersion.
56 Color Sensor Board HW Version
<version> Displays the hardware version of
the color sensor board.
Unknown Cannot retrieve the hardware
v
ersion.
60 Combiner Fan SW Version
<version> Displays the firmware version
running on the combiner fan
board.
Unknown Cannot retrieve the firmware
v
ersion.
61 Combiner Fan HW Version
<version> Displays the hardware version of
the combiner fan board.
Unknown Cannot retrieve the hardware
v
ersion.
Cooling Group (SST+COOL?)
The Cooling Group pro
vides values and fault conditions related to cooling and fans for Crimson.
# Status State Value Description
0
1
2
Intake A (Fan 1)
Intak
e B (Fan 2)
Intake C (Fan 3)
<tach> RPM Displays the current
tachometer reading.
Off Fan is off.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 17
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
Unknown The tachometer reading is
una
vailable.
Off - Overridden Fan is off. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Overridden Fan is on. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Low RPM Fan tachometer reading is
lower than the minimum
recommended speed.
F
or the low RPM threshold,
see Crimson and Mirage
Specifications Guide (P/N:
020-102724-XX).
5
9
Card Cage Intake (Fan 26)
Card Cage Exhaust (Fan 25)
<tach> RPM Displays the current
tachometer reading.
Off Fan is off.
Unknown The tachometer reading is
una
vailable.
<tach> RPM-Low RPM Fan tachometer reading is
lower than the minimum
recommended speed.
F
or the low RPM threshold,
see Crimson and Mirage
Specifications Guide (P/N:
020-102724-XX).
Off - Overridden Fan is off. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Overridden Fan is on. The fan speed
has been changed from its
default recommended
v
alue.
12 Liquid Cooling Flow Meter
<value> L/min Displays the amount of
liquid flowing past the
sensor
.
Off Liquid cooling is off.
Unknown The tachometer reading is
una
vailable.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 18
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
<value> L/min - Flow Impeded The flow reading is lower
than the minimum
recommended threshold.
F
or the low RPM threshold,
see Crimson and Mirage
Specifications Guide (P/N:
020-102724-XX).
13 Liquid Cooling Pump
<tach> RPM Displays the current
tachometer reading.
Off Fan is off.
Unknown The tachometer reading is
una
vailable.
<tach> RPM - Low RPM Fan tachometer reading is
lower than the minimum
recommended speed.
30
55
56
57
58
59
60
Intake D (Fan 4)
R
adiator A (Fan 5)
Radiator B (Fan 6)
Radiator C (Fan 7)
Radiator D (Fan 8)
Radiator E (Fan 9)
Radiator F (Fan 10)
<tach> RPM Displays the current
tachometer reading.
Off Fan is off.
Unknown The tachometer reading is
una
vailable.
Off - Overridden Fan is off. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Overridden Fan is on. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Low RPM Fan tachometer reading is
lower than the minimum
recommended speed.
F
or the low RPM threshold,
see Crimson and Mirage
Specifications Guide (P/N:
020-102724-XX).
101 Liquid Cooling Pump (Combiner)
<tach> RPM Displays the current
tachometer reading.
Off Fan is off.
Unknown The tachometer reading is
una
vailable.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 19
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
# Status State Value Description
<tach> RPM - Low RPM Fan tachometer reading is
lower than the minimum
recommended speed.
F
or the low RPM threshold,
see Crimson and Mirage
Specifications Guide (P/N:
020-102724-XX).
103
104
105
106
107
108
109
110
111
113
114
Exhaust A (Fan 17)
Exhaust B (Fan 18)
Exhaust C (Fan 19)
Phosphor Wheel Heatsink (Fan 16)
Light Engine Exhaust Blower (Fan 24)
Light Engine Exhaust A (Fan 11)
Light Engine Exhaust B (Fan 12)
Combiner Fan (P308)
Combiner Fan (P309)
Exhaust D (Fan 13)
Exhaust E (Fan 14)
<tach> RPM Displays the current
tachometer reading.
Off Fan is off.
Unknown The tachometer reading is
una
vailable.
Off - Overridden Fan is off. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Overridden Fan is on. The fan speed
has been changed from its
default recommended
v
alue.
<tach> RPM - Low RPM Fan tachometer reading is
lower than the minimum
recommended speed.
F
or the low RPM threshold,
see Crimson and Mirage
Specifications Guide (P/N:
020-102724-XX).
Temperature Group (SST+TEMP?)
The T
emperature Group provides values and fault conditions for temperature-related items in Crimson.
# Status State Value Description
2 Air Intake Temperature <value> °C Displays the current
temper
ature of the sensor.
Unknown Temperature reading is
una
vailable.
<value> °C - Low
T
emperature
Temperature is sitting inside
the warning band.
<value> °C - High
T
emperature
Temperature is sitting inside
the warning band.
<value> °C - Too Hot
(shutdown)
Temperature is exceeding the
error threshold.
Crimson status system
Crimson and Crimson Mirage Technical Reference–Status System 20
020-102661-04 R
ev. 1 (07-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Christie Crimson WU25 Technical Reference

Type
Technical Reference
This manual is also suitable for

Christie Crimson WU25

The Christie Crimson WU25 is a high-performance 3DLP laser projector designed for large venues and demanding applications. With its powerful illumination system and advanced optical design, the Crimson WU25 delivers stunning visuals with exceptional brightness, color accuracy, and contrast.

Key features include:

  • True 4K resolution: Experience razor-sharp images and immersive viewing with 4096 x 2160 resolution.
  • High brightness: Delivering up to 27,000 lumens, the Crimson WU25 ensures vibrant and captivating projections even in well-lit environments.
  • Wide color gamut: The projector supports Rec. 2020 color space, providing a wider range of colors for lifelike and realistic visuals.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI