Specifications
The specifications section on this page provide the ratings and other specifications for the Type TAV thermostatic
air vent.
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
Sizes
NPS 3/8, 1/2, 3/4 and 1/ DN 10, 15, 20 and 25
Connection
NPT and Socket weld
Maximum Operating Temperature(1)
650°F / 343°C
Maximum Operating Pressure(1)
650 psig / 44.8 barg
Maximum Allowable Temperature(1)
750°F / 400°C
Maximum Allowable Pressure(1)
650 psig / 44.8 barg
Materials of Construction
Body and Cover: Carbon steel, Stainless steel
Actuator: Welded Stainless steel
Valve and Seat: Hardened 416 Stainless steel
Principle of Operation
Thermal actuator is filled at its free length with a
liquid having a boiling point lower than water. As
assembled, valve is normally open. On startup, air
passes through vent. As air is eliminated, hot steam
reaches vent and the thermal actuator fill vaporizes
to a pressure higher than line pressure. This forces
the valve into seat orifice to prevent any further flow.
When the air collected increases, it takes heat from
the actuator, lowering internal pressure. Line pressure
will then compress thermal actuator to open valve
and discharge air. Valve lift automatically adjusts
to variations.
Installation
▲ WARNING
Personal injury, property damage,
equipment damage or leakage due to
escaping steam or bursting of pressure
containing parts may result if this
vent is over pressured or is installed
where service conditions could exceed
the limits given in the specifications
or where conditions exceed any
ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent
service conditions from exceeding
those limits.
Type TAV thermostatic air vent is installed on the
downstream side of steam trap.
Maintenance
The Type TAV thermostatic air vent is a sealed
unit making it maintenance free. It is composed of
corrosion resistant stainless steel components and
impingement plate with welded construction prevent
damage to actuator. No bolts, gaskets or adjustments
are necessary. Replacement traps cost less than
repair of more expensive in-line repairable vents.