PRODUCT MUST BE INSTALLED
ACCORDING TO ALL APPLICABLE
BUILDING AND LIFE SAFETY CODES
Black = Common
White = N.O. contact (Dry)
Red = N.C. contact (Dry)
Unused wires must be cut
such that no exposed wire
will touch any metallic surface
EXAMPLE WIRING DIAGRAM WITH N.O. MONITORING
Access
Control
System
X
4300
MONITOR
Black
White
Red
4300 WIRING DIAGRAM
INTERMITTENT / CONTINUOUS DUTY 12 / 24V DC
SOLENOID SPECIFICATION
SOLENOID AVAILABLE VOLTAGES
12V DC CONTINUOUS DUTY,
24V DC CONTINUOUS DUTY.
120V AC
LINE
VOLTAGE
4605 / 4606 -24V AC
40 VA TRANSFORMER
RED -
4603
2-AMP
RECTIFIER
RED -
BLACK (-)
4300
ELECTRIFIED DEADLATCH
WHITE (+)
ORANGE
BLUE
YELLOW
BROWN
12V DC
4300
4300
YELLOW
24V DC
ORANGE
BLUE
BROWN
Bevel
Tab
Fig. 4
Yoke
#8-32 x 5/16"
Truss Head Screw
Fig. 3
RHR BEVEL POSITION
LHR BEVEL POSITION
Fig. 5
Dim.
Depth
Inside Stile
wall
Fig. 1
Depth Dim.
3/16"
Hex Key
Mounting
Plate
Tube
Spacer
Fig. 2
FLAT FACE PLATE
NEUTRAL POSITION
Screwdriver
Remove
Bevel
Tabs
Fig. 6
RADIUS WEATHERSEAL
FACEPLATES ONLY
WIRES
BUNDLE
VOLTAGE
ADAPTOR CABLE
4300 SERIES
ELECTRIFIED DEADLATCH
Fig. 7
MONITORING (OPTIONAL)
MONITORED DEADLATCH CONTAINS AN INTERNALLY
MOUNTED SWITCH. THIS SWITCH IS ACTIVATED WHEN
THE DOOR IS IN CLOSE POSITION. ALL UNUSED LEADS
FROM THE MONITOR SWITCH MUST BE INSULATED.
Common contact - Black
Normally Open contact (N.O.) - White
Normally Closed contact (N.C.) - Red
Maximum switching current - 0.1 Amps @ 125 VAC
- LOOP THE WIRES BUNDLE FROM 4300
ELECTRIFIED 'S SOLENOID UNDER AND
AROUND ITS HOUSING AS SHOWN (Fig.7).
- EXTEND THE WIRES RUN FROM THE
POWER SOURCE AND THROUGH THE
STILE PREPARATION.
- CONNECT THE WIRE TO THE VOLTAGE
ADAPTOR CABLE.
- ATTACH VOLTAGE ADAPTOR CABLE
TO 4300 WIRES BUNDLE AS SHOWN.
SOLENOID WIRING DIAGRAM
Note: NOT intend to be a Rex switch.
Page of
2 2
INSTALLATION INSTRUCTIONS
Rev.
Appvd: MP
ECN: 11899
Date: 03/16/12
D
4300 SERIES ELECTRIFIED DEADLATCH