MDS-DTM-RTD SERIES
Battery Powered Benchtop Meter
Optional
For latest product manuals:
omegamanual.info
Shop online at
omega.com
®
Users Guide
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047 USA
Toll Free: 1-800-826-6342 TEL: (203) 359-1660
FAX: (203) 359-7700 e-mail: [email protected]
Canada: 976 Berar
Laval (Quebec), H7L 5A1, Canada
Toll-Free: 1-800-826-6342 TEL: (514) 856-6928
FAX: (514) 856-6886 e-mail: [email protected]
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico/ TEL: 001 (203) 359-1660 FAX: 001 (203) 359-7700
Latin America: e-mail: [email protected]
Servicing Asia:
China:: 1698 Yi Shan Road, Unit 102
Min Hang District
Shanghai, China 201103 P.R.C.
Hotline: 800 819 0559/400 619 0559
Servicing Europe:
Benelux: Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
FAX: +31 20 643 46 43 e-mail: [email protected]
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic
TEL: +420-59-6311899 FAX: +420-59-6311114
France: Toll-Free: 0800 541 038 TEL: 01 57 32 48 17
FAX: 01 57 32 48 18 e-mail: [email protected]
Germany/ Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany
Toll-Free: 0800 8266342 TEL: +49 (0) 7056 9398-0
FAX: +49 (0) 7056 9398-29 e-mail: [email protected]
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611
FAX: +44 (0) 161 777-6622 e-mail: [email protected]
OMEGAnet
®
Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European New
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
i
MDS-DTM-RTD Series
Benchtop Meter
TABLE OF
CONTENTS
Page
Section 1 - Introduction ....................................................................... 1-1
1.1 Precautions ................................................................................................ 1-1
1.2 Safety Warnings and IEC Symbols ......................................................... 1-2
1.3 General Description .................................................................................. 1-2
Section 2 - Hardware .......................................................................... 2-1
2.1 Unpacking and Inspection ...................................................................... 2-1
2.2 Included Items .......................................................................................... 2-1
2.3 DC Power and Battery Connection ........................................................ 2-1
2.3.1 Operation ..................................................................................... 2-1
2.3.2 Power Adaptor ............................................................................ 2-1
2.3.3 Battery Connection ..................................................................... 2-2
Section 3 - Installation and Wiring ....................................................... 3-1
3.1 General Meter Dimensions ...................................................................... 3-1
3.2 Front Panel with Overlay ......................................................................... 3-2
3.3 Rear Panel (Terminal Input, Analog Output, Alarm Output, Wireless) 3-2
3.4 Rear Panel (M8 Input, Analog Output, Alarm Output, Wireless) ..... 3-3
3.5 Rear Panel (M12 Input, Analog Output, Alarm Output, Wireless) .... 3-3
3.6 Rear Panel (Terminal Input, Analog Output, Alarm Output) ............ 3-4
3.7 Rear Panel (M8 Input, Analog Output, Alarm Output) ...................... 3-4
3.8 Rear Panel (M12 Input, Analog Output, Alarm Output) .....................3-5
3.9 Battery Installation/Replacement .......................................................... 3-6
3.10 Installing Wireless Antenna .................................................................. 3-6
3.11 Wiring (Sensor, Analog Output, Alarm Output) ................................ 3-7
Section 4 - Setup & Configuration ........................................................ 4-1
4.1 Getting Started .......................................................................................... 4-1
4.2 Software Utility ......................................................................................... 4-1
4.3 Software Installation ................................................................................ 4-1
4.4 Configuration ............................................................................................ 4-4
Section 5 - Display Features & Meter Operation .................................... 5-1
5.1 Display Features ....................................................................................... 5-1
5.2 Keypad Operation .................................................................................... 5-1
5.3 Button Operation ...................................................................................... 5-2
Section 6 - Optional Wireless Transmitter Operation ............................ 6-1
6.1 Introduction ............................................................................................... 6-1
6.2 RF Communication Basics ....................................................................... 6-1
6.3 Basic System Overview ............................................................................ 6-1
6.4 Transmit Rate vs. Battery Life ................................................................. 6-3
6.5 Wireless Transmitter Setup ...................................................................... 6-5
Section 7 - Maintenance ...................................................................... 7-1
7.1 Calibration ................................................................................................. 7-1
7.2 Cleaning .................................................................................................... 7-1
7.3 Fuse Replacement ..................................................................................... 7-1
ii
MDS-DTM-RTD Series
Benchtop Meter
TABLE OF
CONTENTS
Section 8 - Specifications ..................................................................... 8-1
8.1 General .................................................................................................... 8-1
8.2 Wireless Option ......................................................................................... 8-2
Section 9 - Approvals, Regulatory Compliance ..................................... 9-1
9.1 FCC (Domestic Use) ................................................................................. 9-1
List of Figures
Section Figure Description ............................................................... Page
Section 1 1-1 IEC Symbols ................................................................1-2
Table 1 MDS-DTM-RTD Series Benchtop Meter Versions .. 1-3
Section 3 3-1 General Meter Dimensions ...................................... 3-1
3-2 Front Panel Controls, Indicators ............................. 3-2
3-3 Rear Panel Connections (Terminal Input,
Analog Output, Alarm Output, Wireless) ............. 3-2
3-4 Rear Panel Connections (M8 Input,
Analog Output, Alarm Output, Wireless) ............. 3-3
3-5 Rear Panel Connections (M12 Input,
Analog Output, Alarm Output, Wireless) ............. 3-3
3-6 Rear Panel Connections (Terminal Input,
Analog Output, Alarm Output) .............................. 3-4
3-7 Rear Panel Connections (M8 Input,
Analog Output, Alarm Output) .............................. 3-4
3-8 Rear Panel Connections (M12 Input, Analog
Output, Alarm Output)............................................. 3-5
3-9 Battery Installation/Replacement .......................... 3-5
3-10 Wireless Antenna Installation ................................. 3-6
3-11 Wiring – Temperature Sensor .................................. 3-7
3-12 Wiring – M8 Connector ............................................ 3-7
3-13 Wiring – M12 Connector .......................................... 3-7
3-14 Wiring – Analog Output .......................................... 3-8
3-15 Wiring – Alarm .......................................................... 3-8
Section 4 4-1 Software - Welcome Screen ...................................... 4-1
4-2 Software – Installation Options Screen .................. 4-2
4-3 Software - Select Installation Folder Screen .......... 4-2
4-4 Software – License Agreement Screen ................... 4-3
4-5 Software – Installation Complete Screen ............... 4-3
4-6 USB Programming Cable ......................................... 4-4
4-7 USB Connector Location .......................................... 4-4
4-8 Launch Setup Utility Screen .................................... 4-5
4-9 Utility Program - Welcome Screen .......................... 4-5
4-10 Utility Program –
Connect To Digital Gauge Screen ........................... 4-6
4-11 Utility Program – Verify Connections Screen ....... 4-6
4-12 Utility Program – Establish Link Screen ................ 4-7
4-13 Utility Program – Choose Options Screen ............. 4-8
4-14 Analog Output Options Screen ............................. 4-10
4-15 Calibrations Options Screen
Skip Calibration Option .......................................... 4-12
iii
MDS-DTM-RTD Series
Benchtop Meter
LIST OF
FIGURES
List of Figures continued
Section Figure Description ............................................................... Page
4-16 Calibrations Options Screen
Skip to Next Option ................................................ 4-12
4-17 Send Settings To Digital Gauge Screen –
Finish Option ........................................................... 4-13
Section 5 5-1 Display Features ........................................................ 5-1
5-2 Keypad Operation ..................................................... 5-1
5-3 Menu Button Operation ........................................... 5-3
5-4 Front Keypad Set Button .......................................... 5-5
Section 6 6-1 Fresnel Zone ............................................................... 6-1
Table 2 MDS-DTM-RTD Battery Life – Wireless Mode ..... 6-4
iv
MDS-DTM-RTD Series
Benchtop Meter
LIST OF
FIGURES
Section 1 - Introduction
Please read this manual completely before installing and operating your
instrument. It’s important to read and follow all notes, cautions, warnings and
safety precautions before setting up, installing and operating this unit.
1.1 Precautions
• This device has not been designed, tested or approved for use in any medical
or nuclear applications.
• Never operate this device in flammable or explosive environments.
• Never operate with a power source other than the one recommended in this
manual.
• Never operate this device outside of the recommended use outlined in this
manual.
• Follow all safety precautions and operating instructions outlined in this
manual.
• Keep unit out of reach of children.
• Never operate with a power cord that is not properly rated for use with your
unit.
• Remove and/or disconnect main power cord before attempting any
maintenance or fuse replacement.
• Do not connect and/or operate this unit to a non-grounded, non-polarized
outlet or power source.
For models with wireless transmitter option
• No co-location with other radio transmitters is allowed. By definition, co-
location is when another radio device or it’s antenna is located within 20 cm
of your unit and can transmit simultaneously with your unit.
• Never operate a wireless unit within 20 cm or less from each other.
• Never install and/or continuously operate your wireless unit closer than 20 cm
to nearby persons.
There are no user serviceable parts inside your device.
Attempting to repair or service your unit may void your
warranty.
1-1
Introduction
1
NOTE:
1.2 Safety Warnings and IEC Symbols
This device is marked with international safety and hazard symbols in
accordance with EN61010-1. It is important to read and follow all precautions
and instructions in this manual before operating or commissioning this device as
it contains important information relating to safety and EMC. Failure to follow
all safety precautions may result in injury and/or damage to your calibrator. Use
of this device in a manner not specified by the manufacturer may impair
protection devices and safety features provided by the unit.
IEC symbols Description
Caution, risk of electric shock
Caution, refer to accompanying documentation
Figure 1-1. IEC Symbols
All electrical connections and wiring should be performed by
suitably trained personnel only.
1.3 General Description
OMEGA’s new MDS-DTM-RTD Series Benchtop Meter has the functions of a
digital temperature meter, enclosed in a benchtop case. It is ideal for laboratory
use and applications requiring portable temperature measurement. There is one
basic model, a single-channel unit that features a terminal, M8, or M12 input that
is configured for use with a RTD signal. This meter is factory configured and
calibrated. Standard features include: internal battery or external DC power
supply operation, analog output, and user programmable alarms. The optional
built-in wireless transmitter allows for remote monitoring, chart recording and
data logging. A variety of user configurable options and settings include: update
rate, dampening, units, backlight level, alarm setting, analog output scaling, and
auto-power-off.
Introduction
1
1-2
CAUTION:
Omega offers six different versions of the MDS-DTM-RTD Series Benchtop
Meter.
Table 1: MDS-DTM-RTD Series Benchtop Meter Versions
Version Terminal M8 Connector M12 Connector Analog Alarm Wireless
Input Input Output Output
MDS-DTM-RTD ✔✔
MDS-DTM-RTD-W ✔✔
MDS-DTM-RTD-M8 ✔✔
MDS-DTM-RTD-M8-W ✔✔
MDS-DTM-RTD-M12 ✔✔
MDS-DTM-RTD-M12-W ✔✔
Introduction
1
1-3
Section 2 – Hardware
It is important that you read this manual completely and follow all safety
precautions before operating this instrument.
2.1 Unpacking & Inspection
Remove the packing list and verify that you have received all your equipment. If
you have any questions about the shipment, please call our Customer Service
Department at 1-800-622-2378 or 203-359-1660. We can also be reached on the
Internet at www.omega.com, e-mail: [email protected]. When you receive the
shipment, inspect the container and equipment for any signs of damage. Note
any evidence of rough handling in transit. Immediately report any damage to
the shipping agent.
The carrier will not honor any damage claims unless all
shipping material is saved for inspection. After examining
and removing contents, save packing material and carton in
the event reshipment is necessary.
2.2 Included Items
The following items are supplied in the box.
• 1 MDS-DTM-RTD Series Benchtop Meter
• 1 User’s Guide
• 1 USB Programming Cable
• 1 Setup Utility Software Disk
• 2 D Size Alkaline Batteries
• Mating Connector (M8 and M12 modles only)
• Universal DC Power Adapter
2.3 DC Power and Battery Connection
2.3.1 Operation
Your Benchtop Meter will operate from 12 Vdc to 24 Vdc.
2.3.2 Power Adaptor
A universal power Adaptor has been included with your unit.
DC Power Input Cord
Universal Adaptor 100-240 Vac
2-1
Hardware
2
NOTE:
Hardware
2
2-2
All electrical connections and wiring should be performed by
suitably trained personnel only.
2.3.3 Battery Connection
Your benchtop meter will also operate on 2 D cell Alkaline batteries. Follow
instructions in section 3.9 for details on how to replace the batteries.
NOTE:
3-1
Installation, Mounting & Wiring
3
Section 3 – Installation & Wiring
3.1 General Meter Dimensions
Figure 3-1. General Meter Dimensions
207
(8.13)
80
(3.13)
DIMENSIONS mm (in)
93
(3.68)
Installation, Mounting & Wiring
3
3-2
3.2 Front Panel With Overlay
The front panels of all MDS-DTM-RTD versions are the same. The panels include
the Overlay, LED Screen, and Keypad.
Figure 3-2. Front Panel Controls, Indicators
3.3 Rear Panel (Terminal Input, Analog Output, Alarm Output, Wireless)
Figure 3-3. Rear Panel Connections (Terminal Input, Analog Output, Alarm Output,
Wireless)
°F
0% 100%
MIN MAX
AVG
PEAK
CAL
BAT HAL LAL
LOG
SET
TX
OMEGA ENGINEERING, INC.
STAMFORD, CT. 06907-0047
MDS-DTM-RTD SERIES METER
CAUTION: DISPOSE OF BATTERY PROPERLY
SEE MANUAL FOR INSTRUCTIONS
BATTERY: 2x D-CELL, 1.8 Vdc MAX
12 - 24 Vdc
FUSE: F1A, 250V
WIRELESS ANTENNA
www.omega.com
e-mail:
1 2
3
INPUT
1 2
3
ANALOG OUTPUT
1 2
3
ALARM OUTPUT
USB PORT
INSTALLATION CATEGORY II
Installation, Mounting & Wiring
3
3-3
3.4 Rear Panel (M8 Input, Analog Output, Alarm Output, Wireless)
Figure 3-4. Rear Panel Connections (M8 Input, Analog Output, Alarm Output, Wireless
3.5 Rear Panel (M12 Input, Analog Output, Alarm Output, Wireless)
Figure 3-5. Rear Panel Connections (M12 Input, Analog Output, Alarm Output,
Wireless)
OMEGA ENGINEERING, INC.
STAMFORD, CT. 06907-0047
MDS-DTM-RTD SERIES METER
CAUTION: DISPOSE OF BATTERY PROPERLY
SEE MANUAL FOR INSTRUCTIONS
BATTERY: 2x D-CELL, 1.8 Vdc MAX
12 - 24 Vdc
FUSE: F1A, 250V
WIRELESS ANTENNA
www.omega.com
e-mail:
INPUT
1 2
3
ANALOG OUTPUT
1 2
3
ALARM OUTPUT
USB PORT
INSTALLATION CATEGORY II
OMEGA ENGINEERING, INC.
STAMFORD, CT. 06907-0047
MDS-DTM-RTD SERIES METER
CAUTION: DISPOSE OF BATTERY PROPERLY
SEE MANUAL FOR INSTRUCTIONS
BATTERY: 2x D-CELL, 1.8 Vdc MAX
12 - 24 Vdc
FUSE: F1A, 250V
WIRELESS ANTENNA
www.omega.com
e-mail:
INPUT
1 2
3
ANALOG OUTPUT
1 2
3
ALARM OUTPUT
USB PORT
INSTALLATION CATEGORY II
Installation, Mounting & Wiring
3
3-4
3.6 Rear Panel (Terminal Input, Analog Output, Alarm Output)
Figure 3-6. Rear Panel Connections (Terminal Input, Analog Output, Alarm Output)
3.7 Rear Panel (M8 Input, Analog Output, Alarm Output)
Figure 3-7. Rear Panel Connections (M8 Input, Analog Output, Alarm Output)
OMEGA ENGINEERING, INC.
STAMFORD, CT. 06907-0047
MDS-DTM-RTD SERIES METER
CAUTION: DISPOSE OF BATTERY PROPERLY
SEE MANUAL FOR INSTRUCTIONS
BATTERY: 2x D-CELL, 1.8 Vdc MAX
12 - 24 Vdc
FUSE: F1A, 250V
ANTENNA
www.omega.com
e-mail:
1 2
3
INPUT
1 2
3
ANALOG OUTPUT
1 2
3
ALARM OUTPUT
USB PORT
INSTALLATION CATEGORY II
OMEGA ENGINEERING, INC.
STAMFORD, CT. 06907-0047
MDS-DTM-RTD SERIES METER
CAUTION: DISPOSE OF BATTERY PROPERLY
SEE MANUAL FOR INSTRUCTIONS
BATTERY: 2x D-CELL, 1.8 Vdc MAX
12 - 24 Vdc
FUSE: F1A, 250V
ANTENNA
www.omega.com
e-mail:
INPUT
1 2
3
ANALOG OUTPUT
1 2
3
ALARM OUTPUT
USB PORT
INSTALLATION CATEGORY II
Installation, Mounting & Wiring
3
3-5
3.8 Rear Panel (M12 Input, Analog Output, Alarm Output)
Figure 3-8. Rear Panel Connections (M12 Input, Analog Output, Alarm Output)
3.9 Battery Installation/Replacement
To install or replace the battery in your End Device you must first remove the
cap on the Battery Holder located on the Rear Panel. This will allow you access
to the batteries.
Figure 3-9. Battery Installation/ Replacement
Lithium batteries may get hot, explode or ignite and cause serious injury if
exposed to abusive conditions. Be sure to follow the safety warnings listed below:
• Do not use a different battery other than what is specified in this manual or
product data sheet.
• Do not discharge the battery using any device except your meter.
• Do not place the battery in fire or heat the battery.
• Do not store batteries with other hazardous or combustible materials.
• Do not install the battery backwards so the polarity is reversed.
OMEGA ENGINEERING, INC.
STAMFORD, CT. 06907-0047
MDS-DTM-RTD SERIES METER
CAUTION: DISPOSE OF BATTERY PROPERLY
SEE MANUAL FOR INSTRUCTIONS
BATTERY: 2x D-CELL, 1.8 Vdc MAX
12 - 24 Vdc
FUSE: F1A, 250V
ANTENNA
www.omega.com
e-mail:
INPUT
1 2
3
ANALOG OUTPUT
1 2
3
ALARM OUTPUT
USB PORT
INSTALLATION CATEGORY II
+
+
Installation, Mounting & Wiring
3
3-6
• Do not connect the positive terminal and negative terminal of the battery to
each other with any metal object (such as wire).
• Do not carry or store the battery together with metal objects.
• Do not pierce the battery with nails, strike the battery with a hammer, step on
the battery or otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery.
• Do not expose battery to water or salt water, or allow the battery to get wet.
• Do not disassemble or modify the battery.
Always insulate the terminals with adhesive tape or similar materials before
disposal.
• Immediately discontinue use of the battery if the battery emits an unusual
smell, feels hot, changes color or shape, leaks or appears abnormal in any
other way.
• Do not place the battery in microwave ovens or high-pressure containers.
3.10 Installing Wireless Antenna
To install or replace the wireless antenna, screw the threaded portion of the
antenna on the mounted wireless jack located on the rear panel of the End
Device.
Figure 3-10. Wireless Antenna Installation
WIRELESS
ANTENNA
WIRELESS
JACK
Installation, Mounting & Wiring
3
3-7
3.11 Wiring (Sensor, Analog Output, Alarm Output)
Temperature Sensor
Model MDS-DTM-RTD is designed to operate with a 3-wire, PT100 external
sensor or integral probe assembly. Wires are connected to TB1 located on the rear
panel.
Figure 3-11. Wiring - Temperature Sensor
Figure 3-12. Wiring - M8 Connector Figure 3-13. Wiring - M12 Connector
Front View Front View
TB1
RED WIRE
BLACK WIRES
PT100
SENSOR
132
M12 CONNECTOR
PT100
SENSOR
RED
WIRE
BLACK
WIRES
1
2
3
4
Installation, Mounting & Wiring
3
3-8
Analog Output Wiring Example
Figure 3-14. Wiring - Analog Output
Alarm Wiring Example
Driving a relay or low impedance input (Open Drain)
Figure 3-15. Wiring - Alarm
+
+
_
GROUND
SHIELD WIRE
ENCLOSURE
CHART RECORDER
J2
1
2
3
TB2
* 1N4004 DIODE
ALARM RELAY
200 mA MAX
24 VDC
POWER
SUPPLY
+
+
1
2
3
Section 4 – Setup & Configuration
4.1 Getting Started
This section outlines how to setup and configure your MDS-DTM-RTD Benchtop
Meter before installation and use. All configuration settings are set and saved
into your meter by connecting the included USB programming cable and
running the software utility that was included with your unit on your computer.
4.2 Software Utility
Your computer should meet the following minimum requirements:
• Pentium Class processor
• Hard Drive Space: 210 meg
• Ram: 256 meg or higher
• 1 Available USB Port
• 1 CD-ROM Drive
• Windows 2000, XP, Vista (32bit) Operating System or Windows 7.
4.3 Software Installation
Insert the software CD that was included with your unit into the CD-ROM drive
on your PC. Your system should begin the installation process automatically.
Figure 4-1. Software - Welcome Screen
This welcome screen will be visible on your computer. To continue installing the
program click the “Next >” button.
4-1
Setup & Configuration
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Omega MDS-DTM-RTD Owner's manual

Category
Measuring, testing & control
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI