Omega LVU2700 Series Owner's manual

Category
Measuring, testing & control
Type
Owner's manual
2
3
INTRODUCTION/TABLEOFCONTENTS StepOne
The LVU2700 Seriesis a generalpurpose ultrasonic level transmitter that provides a loop powered 420 mA
output.The420mAoutputcanbeusedtoprovidetheproportional levelofliquidinanytankorvessel.The
signalcanbeconnectedtoanydevicethatacceptslooppowered420mAsignals,suchasa PLC,SCADA,DCS,
display,controller,etc.
NewFeatures
Easilychangeoutputfromdistancetovolume
Selectfrom6standardtankshapes
16pointstrappingtableforcustomer/oddsizetanks
AllwithinthesimpleconfigurationPCSoftwareProgram(LVCN414SW)
TableofContents
Specifications/Dimensions..............................................................................................................................4
SafetyPrecautions............................................................................................................................................5
Components ...................................................................................................................................................6
GettingStarted..................................................................................................................................................7
USB®FobInterface...............................................................................................................................7
LVCN414SWSoftware..........................................................................................................................8
1.Configuration........................................................................................................................9

2.TankShapeSelection..........................................................................................................11
DimensionalEntryVerticalCylinderExample.........................................................12
DimensionalEntryHorizontal
CylinderwithEndcapsExample...............................14
3.LevelConfiguration.............................................................................................................16
4.WritetoUnit.......................................................................................................................16
Wiring .................................................................................................................................................17
WiringDiagram&WireConnections.................................................................................................17
WiringtoDisplays,Controller’s&PLC’s............................................................................................19
Installation .................................................................................................................................................20
MountingGuide..................................................................................................................................20
FittingSelection..................................................................................................................................21
TankAdapters&Risers:..........................................................................................................21
Flanges&SideMountFittings................................................................................................22
StandPipe...............................................................................................................................23
AdvancedFeature...........................................................................................................................................24
Appendix .................................................................................................................................................25
SampleProgram.................................................................................................................................25
UpdatingSoftware..............................................................................................................................26
UpdatingTransmitterFirmware.........................................................................................................27
StrappingTable...................................................................................................................................28
Linervs.NonLinear...........................................................................................................................29
FactoryDefaults..................................................................................................................................31
DemoPage.........................................................................................................................................32
Troubleshooting..................................................................................................................................33
UserSettings
.......................................................................................................................................34

4
SPECIFICATIONS/DIMENSIONS StepTwo
Range:
Accuracy: ±0.2%ofrange
Resolution: LVU2710:0.019”(0.5mm)
LVU2718:0.039”(1mm)
LVU2726:0.079”(2mm)
LVU2726:0.079”(2mm)
Deadband: LVU2710:4”(10cm)
LVU2718/26/32:8”(20cm)
Beamwidth: LVU2710:2”(5cm)
LVU2718/26/32:3”(7.6cm)
Configuration: LVCN414SW(software)PC
Windows®USB2.0
Memory: Nonvolatile
Supplyvoltage: 24VDC(loop)
Consumption: 0.5W
Loopresistance: 500Ohms@24VDC
Signaloutput: 420mA,twowire
Signalinvert: 420mAor204mA
Signalfailsafe: 4mA,20mA,21mA,
22mAorholdlast
Processtemp.: F:‐to140°
C:‐20°to60°
Temp.comp.: Automatic
Ambienttemp.: F:‐31°to140°
C:‐35°to60°
Pressure: MWP=30PSI
Enclosuretype: Type6Pencapsulated,corrosion
resistance&submersible
Encl.material: Polycarbonate
Trans.material: PVDF
Cablejacketmat.:Polyurethane
Cabletype: 4conductorshielded
Cablelength: 10’(3m)
Processmount: LVU2710:1”NPT(1”G)
LVU2718/26/32:2”NPT(2”G)
Mount.gasket: FKM
Classification: Generalpurpose
Compliance: CE,RoHS
Dimensions:
SideView/LVU2710Series
SideView/LVU2718,LVU2726andLVU2732Series

LVU2710:
4"to8'
(10cmto3m)
LVU2718:
8"to9.8'
(20cmto5.5m)
LVU2726:
8"to26.2'
(20cmto8m)
LVU2732:
8"to32.8'
(20cmto10m)
5
SAFETYPRECAUTIONS StepThree
AboutthisManual:PLEASEREADTHE ENTIREQUICKSTARTPRIORTOINSTALLINGORUSINGTHISPRODUCT.
This manual includes information on the LVU2700 Series Ultrasonic Level Transmitter from OMEGA
ENGINEERING. Please refer to the part number located on the switch label to verify the exact model
configuration,whichyouhavepurchased.
User’s Responsibility for Safety:OMEGA ENGINEERING manufactures a broad range of level sensing
technologies. While each of these sensors is designed to operate in a wide variety of applications, it is the
user’sresponsibilitytoselectasensormodelthatisappropriatefortheapplication,installitproperly,perform
tests of the installed system, and maintain all components. The failure to do so could result in property
damageorseriousinjury.
ProperInstallationandHandling:Onlyprofessionalstaffshouldinstalland/orrepairthisproduct.Install the
transmitter with the included FKM gasket andnever over tighten the transmitter within the fitting.Always
checkforleakspriortosystemstartup.
WiringandElectrical:Asupplyvoltageof12to28VDCisusedtopowertheLVU2700Series.Electricalwiring
ofthetransmittershouldbeperformedinaccordancewithallapplicablenational,state,andlocalcodes.
Material Compatibility:The enclosure is made of Polycarbonate (PC).The transducer is made of
PolyvinylideneFluoride(PVDF).Ma kesurethatthemodel,whichyouhaveselected,ischemicallycompatible
withtheapplicationmedia.
Enclosure:While the transmitterhousing is encapsulated,corrosionresistance & submersible, the LVU2700
Series is not designed to be operational when immersed.It should be mounted in such a way that the
enclosure and transducer do not come into contact with the application media under normal operational
conditions.
Safety
Installationshouldbedonebyproperlytrainedstaff
Supplyvoltageshouldneverexceedamaximumof28VDC
Makesurethesensorischemicallycompatiblewithyourapplication
Designafailsafesystemthataccommodatesthepossibilityofsensorand/orpowerfailure.
Thissensorshouldnotbeusedinclassifiedhazardousenvironments
MakeaFailSafeSystem:Designafailsafe system thataccommodatesthepossibilityoftransmitterand/or
power failure.OMEGA ENGINEERING recommends the use of redundant backup systems and alarms in
additiontotheprimarysystem.
Flammable,Explosive
orHazardousApplications:LVU2700Seriesshouldnotbeusedwithinclassified
hazardousenvironments.
Warning: Always use the FKM gasket when installing the LVU2700 Series, and make sure that all electrical
wiring
oftheswitchisinaccordancewithapplicablecodes.

6
Components StepFour
LVU2700Seriesisofferedinfourdifferentmodels.Dependingonthe modelpurchased,youmayormaynot
have been shipped all the components shown below.You do however, need an LVU2700 Series, USB® Fob
andFKMgaskettoconfigure,installandoperateLVU2700Series.
LVU2700Series
PartNumber Range Enclosure MountingThread USB®Fob
LVU2710
LVU2710B
9.8’
(3m)
Type6P
enclosure
1”NPT
Included
NoFob
LVU2710G
LVU2710GB
1”G
Included
NoFob
LVU2718
LVU2718B
18.0’
(5.5m)
2”NPT
Included
NoFob
LVU2718G
LVU2718GB
2”G
Included
NoFob
LVU2726
LVU2726B
26.2’
(8m)
2”NPT
Included
NoFob
LVU2726G
LVU2726GB
2”G
Included
NoFob
LVU2732
LVU2732B
32.8’
(10m)
2”NPT
Included
NoFob
LVU2732G
LVU2732GB
2”G
Included
NoFob
FKMGasket
o Part#200128forLVU2710series
o Part#200129forLVU2718,LVU2726orLVU2732series
USB®Fob
o Part#LVCN414USB
Manual

7
GETTINGSTARTED StepFive
LVU2700 Series is configured through a PC software program (LVCN414SW).The LVCN414SW is a free
download from Omega Engineering’s website.You must download and install the LVCN414SW prior to
pluggingintheUSB®Fob.
Pleasegotohttp://www.omega.com/ftp.
ClickonFlow,Level,pH,Environmental,andPressureSectionandpressonProducts
SelecttheLVCN414folder
Selecttheinstaller‐LVCN414InstallerverXpXX.zip
o Thiswilldownloadtheinstallerontoyourcomputer.
o Oncecompleted,runtheinstaller.
LVCN414SWSoftwareSystemRequirements
Windows®2000,XP,Vista,7,8
32or64bitsystem
1USB®2.0port
10mBharddrivespace
256mBRAM
Internetconnection
USB®FobInterface
LVU2700 Series communicates with the LVCN414SW PC software through a USB® interface called a Fob.
Before plugging your Fob into your computer’s USB® port, be sure that you have installed LVCN414SW on
yourcomputer.
Connect the red, green, white and black wires from LVU2700 Series into the correct terminals on the Fob.
TightenthescrewsontheterminalsandplugyourFobintotheUSB®portofyourcomputer.
Themaximumcabledistancebetweenthecomputerandsen
soris15’.Thisonlyapplieswhenconfiguring
theLVU2700Series.
Once the sensor is configured and prior to installation, isolate the white and green wires from active
powertopreventashortoftheconfigurationcircuit.
Note: When using the USB® Fob, do not add VDC or VAC power.The USB® Fob, when connected to the
computer,willprovidethereq
uiredpowertotheLVU2700Series.

8
GETTINGSTARTED(continued) StepFive
LVCN414SWPCSoftware
WithLVU2700Seriesconnectedtoyourcomputer,openthesoftwarebyclickingontheLVCN414SWicon.
Followsteps13toconfigurethetransmitter.Click“Help”inthelowerrighthandcornerandopenthehelp
menuofthesoftwareforadditionalinstructions.IfyouneedadditionalassistanceusingtheLVCN414SW
software,pleasecontactanOmegaEngineeringApplicationsengineer.
TabsforConfiguration,
UpdatesandDemomode
ModelSelector
(SampleProgramOnly)
ConfigurationSelector
SensorDetails
LevelConfiguration
ActionButtons
TankSelector
AboveScreenCaptureisfortheLVU2726series.
ConfiguringLVU2700SerieswithLVCN414SWSoftware
1. Configuration
a. ConfigurestheLoopFailSafe,OutputatEmpty(420mAor204mA)andStartupCondition.
2. TankShapeSelection
a. Definestheshapeofthetankaswellasthedimensionalinformationforthetankwithrespect
tothesensor’slocationonthetank.
3. LevelConfiguration
a. Entersthedist
ancevaluesfortheoperationalrangeofthesensor.
4. WritetoUnit
a. Uploadstheconfigurationintothesensor.
b. Providesacustomwiringdiagram.

9
GETTINGSTARTED(continued) StepFive
1.Configuration
Thissectionofthesoftwareiswhereyouselecttheapplication’sconfigurationsettings.Startfromthetop
andworktothebottom,choosingtheselectionsthatareapplicabletoyourconfiguration.NotApplicable
willautomaticallyshowwhenaselectiondoesn’tapplytoyourconfigurationsettings,andyoumaymoveon.
AllconfigurationsettingsmustbeselectedorhaveNotApplicablebeforeyoucancontinue.Note:Pressing
theClearScreenbuttonwillresettheconfigurationtableandallowaccesstoallofthefeatures.
LoopFailSafe
Thisfeatureallowsyoutoselectthefailsafecurrentoutputifthe
sensorfailstodetectareturnsignal(LOST).Whenthesensorregains
signal,theoutputcurrentwillrevertbacktothecurrentlevel
condition.
o HoldLastValue‐Theoutputwillremaininthesamestateas
thelastechodetected.Example:Iftheoutputwas6.7mAjust
priortotheLOSTsignal,thedevicewillcontinuetooutput6.7
mA.Whenthesensorregainssignal,theoutputwillindicate
thelevelwhenthesignalwasregain.
o Empty‐TheoutputwillreverttothecurrentvalueofanEmpty
tank.TheemptystateisdependentupontheOutputatEmpty
setting.When4mAatBottomisselected,thesensorwill
output4mAwhenafailsafeconditionoccurs.If20mAat
Bottomisselected,thesensorwilloutput20mAwhenafail
safeconditionoccurs
o Full‐TheoutputwillreverttothecurrentvalueofaFulltank.
ThefullstateisdependentupontheOutputatEmptysetting.
When4mAatBottomisselected,thesensorwilloutput20mA
whenafailsafeconditionoccurs.If20mAatBottomis
selected,thesensorwilloutput4mAwhenafailsafecondition
occurs
o Overfill(21mA)‐Theoutputcurrentwillgoto21mAwhenthe
returnsignalislost.
o Overfill(22mA)‐Theoutputcurrentwillgoto22mAwhenthe
returnsignalislost.
Note:Rightclickonanymenuthatyoumayhavequestionsontoopenthehelpmenu.
Note:Toreset,presstheClear
Screenbutton.

10
GETTINGSTARTED(continued) StepFive
OutputatEmpty
Thisfeatureallowsyoutoselecttheorientationofthe4to20mA
output(4to20mAor20to4mA).Choosewhichoutputsettingbest
fitstheapplication.Typicalinstallationsaresetwith4mAatBottom.
Thiswillnotaffecttheperformanceofthesensorotherthanthe
outputoftheLVU2700Series.Thesoftware’sfactorydefaultis4mAat
bottomand20mAattop.Whenconnectingyoursensortoadisplay,
youmustaccountforyouroutputsettings.
o 4mAatBottom‐Theoutputcurrentwillbe4mAwhenthe
sensormeasuresanemptytankand20mAwhenthesensor
measuresafulltank.
o 20mAatBottom‐Theoutputcurrentwillbe20mAwhenthe
sensormeasuresanemptytankand4mAwhenthesensor
measuresafulltank
StartupCondition
Thisfeatureallowstheoperatortoselecttheoutputcurrenton
initialstartuppriortoacquiringatruereturnsignal(level
measurement).Thisonlyoccursduringtheinitialpoweringof
LVU2700Seriesandthetransmitterwillreverttothecorrectlevel
readingwhenthelevelisacquired.
o Empty‐SelectsthestartupcurrentestablishedinOutputat
Empty.Example:Select4mAatBottom,theoutputwill
remainat4mAuntiltheunitacquiresatruereturnecho.
Select20mAatBottom,theoutputwillremainat20mA
untiltheunitacquiresatruereturnecho.
o MidTank‐Whenselected,thestartupcurrentwillread12
mAuntiltheunitacquiresatruereturnecho.
o
FullTank‐Usestheoppositecurrentthatwasselectedin
OutputatEmpty.Example:Ifyouselect4mAatBottomthen
thestartupcurrentwouldbe20mA.Ifyouselect20mAat
Bottomthenthestartupcurrentwouldbe4mA.
o
Overfill(22mA)‐Theoutputatstartupwouldbe22mA.This
conditionwillremainuntiltheunitacquiresatruereturn
echo.
Note:Rightclickonanymenuthatyoumayhavequestionsontoopenthehelpmenu.
Note:Toreset,presstheClear
Screenbutton.

11
GETTINGSTARTED(continued) StepFive
2.TankShapeSelection
The sensor may be configured in volumetric units (Gallons or Liters) or Distance (Height of Liquid) units
(inches,cm,feetormeters).TheLVCN414SWsoftwarewilldefaultinDistance(HeightofLiquid)withunits
of Inches.To change the units or to change from Distance to Volume, press the Select Tank Shape button
locatednearthecenterofthewindow.
ShapeSelectionWindow:ThiswindowwillshowsthedifferenttankshapeoptionsavailableinWebCal™.
VerticalCylindrical
VerticalCylindricalwithConeBottom
HorizontalCylindricalwithEndcaps
HorizontalCylindricalwithSphericalEnds
Spherical
Rectangular
Strapping Table Use this feature for manual entry
ofmeasuredtankdistancesandvolumes.
Select any of the above tank shapes and press OK to
confirm.

12
GETTINGSTARTED(continued) StepFive
Dimensional Entry Vertical Cylindrical Example:Choose the Sensor Output Units as Distance or Volume.
AfterchoosingtheSensorOutputUnits,selecttheunitsofmeasurementinthepulldowntotheleft.
UnitsofMeasurement
Distance Volume
Inches
Cm
Feet
Meters
Gallons
Liters
DistanceSensorOutputUnits:
Enter the dimensions of the tank.You must
enterdatainallfieldsshown.
SensorHeight:Distancefromthebottomof
thetanktothebottomofthetransducer.
FillHeight:Distancefromthebottomofthe
tanktothemaximumliquidheight.
RiserHeight:Distancethesensorisrecessed
within a riser, measured from the bottom of
thesensortotheinsideofthetank.
VolumeSensorOutputUnits:
Enter the dimensions of the tank.You must
enterdatainallfieldsshown.
SensorHeight:Distancefromthebottomof
thetanktothebottomofthetransducer.
FillHeight:Distancefromthebottomofthe
tanktothemaximumliquidheight.
RiserHeight:Distancethesensorisrecessed
within a riser, measured from the bottom of
thesensortotheinsideofthetank.
Tank Height:Distance from the bottom of
thetanktothetopofthestraightsidewall.
Diameter:Distance of the inside tank
diameter.

13
GETTINGSTARTED(continued) StepFive
Volume Tank Capacity:After entering the dimensions, press the Capacity button to show the Calculated
Capacity of the tank.If the Calculated Capacity is slightly different than the expected capacity, click on the
AdjustCapacityboxandentertheexpectedcapacityofthetank.IftheAdjustedCapacityismorethan10%of
theCalculatedCapacity,recheckthedimensionsinformationenteredabove.
Whenalldimensionsareentered,presstheApplybuttontoreturntothepreviousConfigurationwindow.
ApplyTransfersthedimensionstotheoriginalConfigurationwindow.
TanksReturnstothepreviousShapeSelectionwindow.
CancelReturnstotheConfigurationwindowwithoutsavinganyinformation.
HelpJumpstotheHelpmenu.

14
GETTINGSTARTED(continued) StepFive
Dimensional Entry Horizontal Cylindrical with Endcaps Example:Choose the Sensor Output Units as
Distance or Volume.After choosing the Sensor Output Units, select the units of measurement in the pull
downtotheleft.
UnitsofMeasurement
Distance Volume
Inches
Cm
Feet
Meters
Gallons
Liters
DistanceSensorOutputUnits:
Enter the dimensions of the tank.You must
enterdatainallfieldsshown.
SensorHeight:Distancefromthebottomof
thetanktothebottomofthetransducer.
FillHeight:Distancefromthebottomofthe
tanktothemaximumliquidheight.
RiserHeight:Distancethesensorisrecessed
within a riser, measured from the bottom of
thesensortotheinsideofthetank.
VolumeSensorOutputUnits:
Enter the dimensions of the tank.You must
enterdatainallfieldsshown.
SensorHeight:Distancefromthebottomof
thetanktothebottomofthetransducer.
FillHeight:Distancefrom
thebottomofthe
tanktothemaximumliquidheight.
RiserHeight:Distancethesensorisrecessed
within a riser, measured from the bottom of
thesensortotheinsideofthetank.
TankHeight:Distancefromthebottomofthetanktothetopofthestraightsidewall.
CylinderLength:Distanceofthestraightlengthofthetank.
EndCapLength:Distanceofoneendcap.Bothendcapswillbeusedinthevolumecalculation.

15
GETTINGSTARTED(continued) StepFive
Volume Tank Capacity:Upon entering the dimensions, press the Capacity button to show the Calculated
Capacity of the tank.If the Calculated Capacity is slightly different than the expected capacity, click on the
AdjustCapacityboxandentertheexpectedcapacityofthetank.IftheAdjustedCapacityismorethan10%of
theCalculatedCapacity,recheckthedimensionsenteredabove.
Whenalldimensionsareenterediscompleted,presstheApplybuttontoreturntothepreviousConfiguration
window.
ApplyTransfersthedimensionsbacktotheoriginalConfigurationwindow.
TanksReturnstothepreviousShapeSelectionwindow.
CancelReturnstotheConfigurationwindowwithoutsavinganyinformation.
HelpJumpstotheHelpmenu.

16
GETTINGSTARTED(continued) StepFive
3.LevelConfiguration
Thissectionofthesoftwareis whereyouenterapplicationmeasurementvalues.Allvaluesmustbe filledin
beforemovingtothenextstep.
Sensor Height: Distance from
thebottomofthe tanktothe
bottomofthetransducer.
Fill Height: Distance from the
bottom of the tank to the
maximumliquidheight.
Note: If Volume is selected,
Sensor Height and Fill Height
are grayed out and can only
be changed on the
DimensionalEntryPage.Also,
the Capacity of the tank will
be shown in the lower left
corner.
4.WritetoUnit
Afteryouha ve enteredconfiguration,tankshape informationandlevelvalues,c lick WritetoUnittoload
theconfigurationintothe memoryofthesensor.Whencompleted,thisconfigurationwill remaininsidethe
sensor’smemory and willnotchange unless the sensor is connectedto LVCN414SW software anda new
configurationiswrittentothesensor.Lossofpowerwillnotchangeorlosetheconfigurationwithinsensor
memory.
Next, use the file management features to save your
configurationbyclickingSaveConfigFileandprintyourwiring
diagrambyclickingWiringDiagram.”
SaveConfigFilewillsavethisconfigurationasatextfilewhich
can be loaded back into the LVCN414SW
software by pressing
the Open Config File button.It is good practice to save the
configuration file for each different configuration with a unique
nameforeasyidentification.Ifusingmultiplesensorsinidentical
applications, then use of a single configuration file is
recommended.
Wiring Diagram will display a PDF file showing the unique
wiring for the specific configuration created.The PDF can be
printedorEmailed.Itisgoodpracticetosavethewiringdiagram
asabackup.
WritetoUnit
Wiringdiagram
SaveConfigFile

17
WIRING StepSix
WiringDiagram
WiringLVU2700Series
After you have finished positioning and mounting LVU2700 Series, follow the software’s wiring diagram to
wireLVU2700Series.OmegaEngineeringrecommendsusingaqualified licensedelectriciantowireLVU2700
Seriesandyourapplication’scomponents.
WireConnections:
Red&Black
RedandBlackleadsareforconnectiontoa24
VDCpowersupplyortoa420mAlooppowersource.Thered
andblackwirescanbeextendedupto1,000feetusinga22gaugeorlargerwire;howeverdonotextendthe
greenandwhitewires.
White&Green
WhiteandGreenleadsarereservedforusewiththesoftwareandshouldnot be connected during usage in
theapplication.Thesewiresshouldnotbeconnectedto the LVCN414SW whilepowerissupplied from any
sourceotherthantheLVCN414USBseriesFob.
Note: Once the LVU2700 Series is configured, isolate the white and green wires from active power to
preventashortoftheconfigurationcircuit.
Note:DonotextendtheWhite&Greenwiresbeyond15’.

18
WIRING(continued) StepSix
Generalnotesforelectricalconnections,usageandsafety:
Where personal safety or significant property damage can occur due to a spill, the installation must
havearedundantbackupsafetysysteminstalled.
Wiringshouldalwaysbecompletedbyalicensedelectrician.
Supplyvoltageshouldneverexceed28VDC.
Thesensormaterialsmustbechemicallycompatiblewiththeliquidstobemeasured.
Designafailsafesystemforpossiblesensorand/orpowerfailure.
NeverusethesensorinenvironmentsclassifiedasHazardous.
VoltageOutput
LVU2700Seriescanbeusedasa0to5or0to10VDCoutputdevice.Aresistorwillneedtobeaddedtothe
circuittoenableavoltageoutput(refertothewiringdiagrambelow).
05VDCoutput
o Adda250Ohmresistor
o Actualoutputwillbe0.8to5VDC
010VDCoutput
o Adda500Ohmresistor
o Actualoutputwillbe2to10VDC

19
WIRING(continued) StepSix
WiringtoDisplay,Controllers&PLC’s(continued)
ProportionalLevelController
LVCN51Series
JWAmode(FactorySetting)
ProportionalLevelController
LVCN51Series
JWBmode
GenericLoop
PoweredDisplay
GenericPLC

20
INSTALLATION StepSeven
The LVU2700 Series should always be mounted perpendicular to the liquid surface and installed using the
providedFKMmountinggasket.Makesurethatthefittingandtransmitterthreadsarenotdamagedorworn.
Always handtighten the transmitter within the fitting.Perform an installed leak test under normal process
conditionspriortosystemstartup.Note:ThepreferredmountingfittingfortheLVU2710seriesisaplastic(2”
threadx1”thread)reducerbushing.
MountingGuide
1. Donotmountatanangle
2. Liquidshouldneverenterthedeadband
3. SideWall:
a. ForLVU2710Series‐mountatleast2”fromtheside
wall
b. ForLVU2718,LVU2726&LVU2732Series‐mountat
least3”fromthesidewall
4. Donotmountwhereobstacleswillintrudeonsensor’s
beamwidth
a. LVU2710Series‐mountatleast2”fromobstacles
b. ForLVU2718,LVU2726&LVU2732Series‐mountat
least3”fromobstacles
5. Donotmountinavacuum
6. Avoidmountinginthecenterofadometoptank.
7. Inconebottomtank,positionthesensoroverthe
deepestpartofthetank.
Installationinexistingfittings:Iftheexistingfittingislarger
than the threads of the sensor, select a reducer bushing
suchastheLVU8002N40(2”threadx1”thread)orLVU800
3N40(3”threadx2”thread).
LVU8002N40
LVU8003N40
Donotinstallat
anglerelativeto
theliquid.
Donotinstall
within3”oftank
sidewall.
Donotinstallwith
objectsinthe
beam.
Donotinstallin
applicationswith
vacuum.
MetalTanks(LVU2710series)
OmegaEngineeringultrasonictransmittershavebeenoptimizedforuseinnonmetallicfittings.
1. Forbestperformance,avoidtheuseofmetallicfittings.
a. Useaplastic2”x1”reducerbushing(suchasLVU8002N40)oraplastic1”tankadapter(such
asLVU8001B).
2. While installations directly into a 1” metal fitting are not recommend
ed, acceptable results may be
obtained if the 1” fitting is a half coupling in form and the outer diameter of the coupling is tightly
wrappedinvinyltapetodampenvibrations.

  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36