Audioplex RCLL-1L Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Audioplex RCLL-1L Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
RCLL-1L
TheRCLL-1L linelevelremotevolumecontrolisaversatilemeansof
controllingthevolumeofalinelevelsource.Ittypicallyconnectsbetween
asourceandanamplifier. Thelevelmaybecontrolledthreeways:Using
theincludedIReye,fromaremotelocationusinganinfraredrepeating
system,ormanuallywithaknobatthefrontoftheunit.Ithastheabilityto
learncommandsforvolumeup,down,andmutefrommostconsumer
remotecontrols(notincluded).Itispoweredbyasupplied12voltpower
adaptor.
INSTALLATION
Followthewiringdiagramonthebackofthissheet,usingRCA cables(not
included)fr theRCLL-1tothesourceandamplifier. Tousearemote
controlinthesameroomastheRCLL-1,plugtheincludedIReyeintothe
jackonthebackoftheunit,andmountitinalocation hereitcansee
theremote. Toconnectanoptionalinfraredrepeatingsystem,connectthesignalandgroundwiresofthesystemto
thebindingposts,payingattentiontopolarity:signaltored,groundtoblack.Setthevolumecontrolonthefront
toaboutmidrange,thenconnecttheincludedpowersupplytothejackontherearandplugitintoan ACoutlet.
om
EYE w
TECHNOLOGY
INSTALLATIONMANUAL
404GWHP.O.BOX440
MELVINVILLAGE,N.H.03850
1-800-257-2077603-544-8601FAX:603-544-8901
www.audioplex.com
AUDIOPLEXTECHNOLOGY
20139/11/13
LearningRemoteControlled
LineLevelVolumeControl
OPERATION
Whentheunitispoweredup,thevolumewillbeat .
TheRCLL-1willrespond volumeup,volumedown,andmutecommands .
Holdingeithervolumebuttonontheremotewillcausetheunittocontinuouslychangevolume.
knob to themaximumvolume
areducedvolume,thenincreasetomaximumafter5seconds
to programmedintotheRCLL-1L
Thefront maybeused limit .Itisnotcontrolledbytheremote.
PROGRAMMING
TheRCLL-1L ispreprogrammedtoworkwithProscanamplifiercommands.Ifyouhavearemotethatcansend
thesecommands,skiptothesectiononOPERATION.
ToprogramtheRCLL-1L forspecificremotecommands,firstdecidewhatkeysonyourremoteyouwanttouse
for VolumeUp, VolumeDown,andMute. Theyprobablyshouldn’tbebuttonsyouuseforanotherdevicesothat
commandsmeantforthatdevicewon’tcontroltheRCLL-1L andviceversa.
ToplacetheRCLL-1L inlearningmode,disconnectthepowerfromthebackoftheunit,getyourremoteready,
andplugthepowerbackin. Within5secondspressthekeyforvolumeup,volumedown,mute,volumeup
(again),volumedown(again),andMute(again).
Learnmodeisindicatedbyaloweredvolumelevel,andwillcancelif:
Youtakelongerthan5secondstopressthenextkey
Thekeysequenceiswrong,suchasakeyhelddowntoolongandregisteredtwice
Thevolumeup,volumedown,andmutesequenceisn’trepeated
Ifyouhaveproblemsafterseveraltriesatprogramming,yourremote(orfunctionkeys)maybeincompatible.
Tryadifferentkey,mode,orremote.
Learnedcommands(includingfactoryprogrammedProscancommands)aresaveduntilnewcommandsare
programmed.
Formorehelporinformation,contact Audioplextechnicalsupportat800-257-2077or[email protected].
Testyourkeysforproperfunction.Iftheydon’tworkasdesired,repeatthelearnprocess.
AUDIOPLEXTECHNOLOGY
404GWHP.O.BOX440
MELVINVILLAGE,N.H.03850
1-800-257-2077603-544-8601FAX:866-257-2103
www.audioplex.com
WARRANTY
Your AUDIOPLEX TECHNOLOGY RCLL-1iscoveredbyaLIFETIME WARRANTY againstany
defectsinworkmanshipandmaterials. Anydefectswillberemediedwithoutchargeforlabororparts.
Damageincurredbyshippingoraccidentisnotconsideredtobeadefect,andnotcoveredbythis
warranty. AUDIOPLEX TECHNOLOGY isnotresponsiblefordefectiveoperationcausedbyabuseorby
modificationorservicebyanyunauthorizedpersonoragency.
Theunitmustbeproperlyinstalledandoperatedaccordingtoinstructionsforthewarrantytoapply. Any
necessaryservicingmustbedoneby AUDIOPLEX TECHNOLOGY. Theproductsmustbereturnedexpenses
prepaid,withwrittenauthorizationfromthecompany. Theproductmustbeshippedwiththeproofofpurchase
andintheoriginalcartonandpackingmaterialtoavoiddamage.
2013-9/11/13
WIRINGDIAGRAM
12VDC
FROMIR
REPEATING
SYSTEM
12VPOWER
SUPPLY
IREYE
IR
EYE
LINE
IN
LINE
OUT
FROM
SOURCE
LINEOUT
TO AMP
LINEIN
APPLICATIONNOTE
Manymodern TVshaveafixedaudiolevelfromtheirlineleveloutputs.Usingthese TVswithan
externalampmeansthatthe TV’sremotenolongerworks.
InstalltheRCLL-1L betweenthe TV andtheamp,andprogramittorespondtothe TV’s Volume
andMuteremotecommandstorestorethisfunction.
/