Carrier 38QUS012DS Installation guide

Type
Installation guide

This manual is also suitable for

WALL MOUNTED AIR CONDITIONER
BEIJER RET AB
Stortorget 8
Malmö
Sweden
INSTALLATION MANUAL
G B
ENGLISH
INSTALLATION MANUAL
I T
ITALIANO
MANUALE DI INSTALLAZIONE
F R
MANUEL D'INSTALLATION
D E
INSTALLATIONSHANDBUCH
DEUTSCH
E S
MANUAL DE INSTALACIÓN
N L
INSTALLATIEHANDLEIDING
NEDERLANDS
FRANÇAIS
ESPAÑOL
P L
POLSKI
INSTRUKCJA MONTAŻU
02
01
This product has been det ermined t o be in compliance wit h t he Low Voltage Directive (2006/95/EC),
and t he Electromagnetic Compat ibilit y Directive (2004/108/EC) of t he European Union.
Correct Disposal o f This Product
(Waste Electrical & Electronic Eq uipment)
(When using this air conditioner in European countries, the following guidance must be followed)
- This marking shown on the product or its literature, indicates that waste electrical and eletrical equipment (WEEE as in
directive 2002/96/EC) should not be mixed with general household waste.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
1. The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to
the user.
2. When buying a new product, the retailer will take back the old product at least free of charge.
3. The manufacture will take back the old appliance for disposal at least free of charge to the user.
4. As old products contain valuable resources, they can be sold to scrap metal dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the
ground-water and find their way into the food chain.
CONTENT
1.1 Safety Precautions
1.2 Installation Diagram
2.1 Indoor Installation
2.2 Outdoor Installation
2.3 Wiring Work
2.4 Air Evacuation And Test Operation
02
04
05
06
07
08
1. READ BEFORE OPERATING
2. OPERATION
READ BEFORE INSTALLATION
1.1 Safety Precautions
WARNING
This symbol indicates the possibility of
personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of
property damage or serious onsequences.
42QHF012DS*
Indoor Unit Outdoor Unit Rated Voltage & Hz
38QUS012DS*
42QHF018DS*
42QHF022DS*
38QUS018DS*
38QUS022DS*
220-240V ~ 50Hz
42QHF009DS* 38QUS009DS*
810x310x558
845x320x700
780x320x700
Dimension(IDU)
800x188x275
800x188x275
940x205x275
1045x235x315
Dimension(ODU)
810x310x558
Installing, starting up, and servicing air-conditioning equipment can be hazardous due to system ressures,
electrical components, and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should install, start-up, and serve this equipment.
When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached
to the equipment.
Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher
nearby when brazing. Use care in handing, rigging, and setting bulky equipment.
Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the
unit. Consult local building codes and National Electrical Code for special requirement.
IMPORTANT
READ BEFORE INSTALLATION
04
03
This product contains fluorinated gases covered by the Kyoto Protocol
Chemical Name of Gas
Global Warming Potential (GWP) of Gas
R410A
2088
CAUTION
1. Paste the enclosed refrigerant label adjacent to the charging
and/or recovering location.
2. Clearly write the charged refrigerant quantity on the
refrigerant label using indelible ink.
3. Prevent emission of the contained fluorinated gas. Ensure
that the fluorinated gas is never vented to the atmosphere
during installation, service or disposal. When any leakage
of the contained fluorinated gas is detected, the leak shall
be stopped and repaired as soon as possible.
4. Only qualified service personnel are allowed to access and
service this product.
5. Any handling of the fluorinated gas in this product, such as
when moving the product or recharging the gas, shall comply
under (EC) Regulation No. 842/2006 on certain fluorinated
greenhouse gases and any relevant local legislation.
6. Contact dealers, installers, etc., for any questions.
1.1 Safety Precautions
Note: Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
15cm or more
2.3m or more
60cm or more
30cm or more
12cm or more
12cm or more
30cm or more
60cm or more
200cm or more
1.2 Installation Diagram of Indoor and Outdoor Units
The refrigerant lines may be routed
in any of the four directions.
Left
tubing
Right tubing
Right-rear
tubing
Left-rear tubing
If drain cap exist, the drain hose
can be exchanged.
Drain cap
Put a cushioning material to have
installation space for rear tubing.
Cushioning
material
Drain outlet (1)
1
2
3
Installation plate (1)
Anchor (5 or 8)
Gasket (1)
Battery (2)
Screw B (2)
Optional (Model Specific)NoNo Name (Qty)
Screw A (5 or 8) Remote controller holder (1)
Remote controller (1)
4
5
6
INSTALLATION
06
05
2.1 Indoor Installation 2.2 Outdoor Installation
INSTALLATION
08
07
2.3 Wiring Work 2.4 Air Evacuation and Test Operation
60mm
40mm10mm
Power input cord
GND
60mm
40mm10mm
GND
Connective Cable
W1(L) 2(N) S L N
Power Input
To Indoor
W1(L) 2(N) S L N
Power Input
To Indoor
W 1(L) 2(N) S
To outdoor
W 1(L) 2(N) S
To outdoor