  • Hello! I am an AI chatbot trained to assist you with the Dean Dean Millivolt Gas Fryers CE User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Price: $8.00
Service Hotline 1-318-865-1711
819-5894
MAY 2007
Dean Millivolt Gas Fryers (CE)
Installation & Operation Manual
Models SM20, SM35, SM40, SM50, SM60, SM80, SR42, SR52 & SR62
CE ONLY
i
Please read all sections of this manual and retain for future reference.
NOTICE
This appliance is intended for professional use only and is to be operated by qualified
personnel only. A Dean Factory Authorized Service Center (FASC) or other qualified
professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
NOTICE
This equipment must be installed in accordance with the appropriate national and local codes of
the country and/or region in which the appliance is installed.
NOTICE
Drawings and photos used in this manual are intended to illustrate operational, cleaning and
technical procedures and may not conform to onsite management operational procedures.
NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful interference, and 2) This device must accept
any interference received, including interference that may cause undesired operation. While
this device is a verified Class A device, it has been shown to meet Class B limits.
Canada
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set
out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A
et B prescrites dans la norme NMB-003 edictee par le Ministre des Communications du Canada.
DANGER
Improper installation, adjustment, maintenance or service, and unauthorized alterations or
modifications can cause property damage, injury, or death. Read the installation, operating and
service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was
originally configured. See Chapter 1 of this manual for definition of qualified service personnel.
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing
anchor straps. All fryers equipped with casters must be stabilized by installing restraining
chains. If a flexible gas line is used, an additional restraining cable must be connected at all
times when the fryer is in use.
ii
DANGER
The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result
from slips or contact with the hot oil.
CAUTION
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
CAUTION
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak
must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.
DANGER
The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container
at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.
WARNING
No structural material on the fryer should be altered or removed to accommodate placement of
the fryer under a hood. Questions? Call the Dean Service Hotline at 1-800-551-8633.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal
the joint between the frypot. Banging fry baskets on the strip to dislodge shortening will distort
the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for
cleaning.
IMPORTANT
Safe and satisfactory operation of Dean equipment depends upon its proper installation.
Installation MUST conform with local codes, or in the absence of local codes, to European
Community (CE) Standards.
NOTICE
The Commonwealth of Massachusetts requires any and all gas products to be installed by a
licensed plumber or pipe fitter.
i
Dean Millivolt Gas Fryers (CE)
Installation & Operation Manual
TABLE OF CONTENTS
Page #
1. INTRODUCTION 1-1
1.1 Applicability and Validity 1-1
1.2 Ordering Parts 1-1
1.3 Service Information 1-1
1.4 Safety Information 1-2
1.5 Service Personnel 1-2
2. IMPORTANT INFORMATION 2-1
2.1 Receiving and Unpacking Equipment 2-1
2.2 General 2-1
2.3 Principles of Operation 2-2
2.4 Rating Plate 2-3
2.5 Pre-Installation 2-3
2.6 Equipment Installed at High Altitudes 2-4
2.7 Air Supply and Ventilation 2-4
2.8 Conversion of Units 2-5
3. INSTALLATION 3-1
3.1 Installing the Fryer 3-1
3.2 Installing Casters and Legs 3-1
3.3 Leveling the Fryer 3-2
3.4 Gas Connections 3-4
3.5 Adjustments/Adaptation to Different Gases 3-8
3.6 Gas Inputs 3-9
3.7 Gas Conversion Procedures 3-11
3.8 Gas Conversion Components 3-13
3.9 Electrical Connections 3-13
ii
Dean Millivolt Gas Fryers (CE)
Installation & Operation Manual
TABLE OF CONTENTS (CONT.)
Page #
4. FRYER OPERATIONS 4-1
4.1 Initial Start-up 4-1
4.2 Boil-Out Procedure 4-3
4.3 Final Preparation 4-5
5........ PREVENTATIVE MAINTENANCE 5-1
5.1 General 5-1
6........ TROUBLESHOOTING 6-1
6.1 General 6-1
6.2 Pilot Burner Malfunctions 6-1
6.3 Main Burner Malfunction 6-2
6.4 Millivolt Wiring Diagram 6-3
6.5 Recommended Spare Parts 6-4
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 1: INTRODUCTION
1-1
1.1 Applicability and Validity
Dean Super Marathon and Super Runner Series gas model families have been approved by the
European Union (EU) for sale and installation in the following EU countries: AT, BE, KE, KD,
ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE.
This manual is applicable to and valid for all Dean Super Marathon and Super Runner gas
units sold in English-speaking countries, including those in the European Union. Where
conflicts exist between instructions and information in this manual and local or national codes
of the country in which the equipment is installed, installation and operation shall comply with
those codes.
This appliance is only for professional use and shall be used by qualified personnel as defined
in Section 1.5.
1.2 Ordering Parts
Customers may order parts directly from their local Authorized Parts Distributor. For this address
and phone number, contact your maintenance and repair center or call the factory. The factory
address and phone numbers are on the back cover of this manual.
To speed up your order, the following information is required:
Model Number
Type
Serial Number
Optional Equipment
Item Part Number
Quantity Needed
1.3 Service Information
Call the 1-800-551-8633 or (318) 865-1711 Service Hotline number for the location of your nearest
maintenance and repair center. Always give the model and serial numbers of your fryer.
To assist you more efficiently, the following information will be needed:
Model Number
Type
Serial Number
Optional
Equipment
Nature of Problem
Additional information (i.e. cooking environment, time of day, and other pertinent
information) may be helpful in solving your service problem.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 1: INTRODUCTION
1-2
1.4 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the
ones below.
CAUTION boxes contain information about actions or conditions that may cause or result in a
malfunction of your system.
CAUTION
Example of a CAUTION box.
WARNING boxes contain information about actions or conditions that may cause or result in
damage to your system, and which may cause your system to malfunction.
WARNING
Example of a WARNING box.
DANGER boxes contain information about actions or conditions that may cause or result in injury
to personnel, and which may cause damage to your system and/or cause your system to malfunction.
DANGER
Hot cooking oil causes severe burns. Never attempt to move a fryer containing hot
cooking oil or to transfer hot cooking oil from one container to another.
1.5 Service Personnel
1.5.1 Definitions
A. Qualified and/or Authorized Operating Personnel
1. Qualified/authorized operating personnel are those who have carefully read the information
in this manual and have familiarized themselves with the equipment functions, or have had
previous experience with the operation of equipment covered in this manual.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 1: INTRODUCTION
1-3
1.5.1 Definitions (cont.)
B. Qualified Installation Personnel
1. Qualified/authorized personnel are those who have carefully read the information in this
manual and have familiarized themselves with the equipment functions, or who have had
previous experience with the operation of the equipment covered in this manual.
C. Qualified Service Personnel
1. Qualified service personnel are those who are familiar with Dean equipment and have been
authorized by Dean to perform service on Dean equipment. All authorized service
personnel are required to be equipped with a complete set of service parts manuals and stock
a minimum amount of parts for Dean equipment. A list of Dean Factory Authorized Service
Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use
qualified service personnel will void the Dean warranty on your equipment.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
2-1
2.1 Receiving and Unpacking Equipment
A. Check that the container is upright. Use an outward prying motion - no hammering - to remove
the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard
or misplace accessories. They will be needed.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact
the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
1. File claim for damages immediately, regardless of extent of damage.
2. Visible loss or damage: Be sure this is noted on the freight bill or express receipt and is
signed by the person making the delivery.
3. Concealed loss or damage: If damage is unnoticed until equipment is unpacked, notify
freight company or carrier immediately, and file a concealed damage claim. The claim
should be filed within 15 days of date of delivery. Be sure to retain container for inspection.
NOTE: Dean Does Not Assume Responsibility for Damage or Loss Incurred in Transit.
C. Move the fryer to the location of installation and install legs and/or casters as described in
Chapter 3.2.
D. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to
initial fryer operation will make it very difficult to remove later.
2.2 General
Qualified, licensed, and/or authorized installation or service personnel only (as defined in
Section 1.5) should perform the following:
Installation and service on Dean equipment.
Conversion of this appliance from one gas type to another.
Failure to use qualified, licensed, and/or authorized installation or service personnel to install,
convert to another gas type or otherwise service this equipment will void the Dean warranty
and may result in damage to the equipment or injury to personnel.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
2-2
2.2 General (cont.)
Where conflicts exist between instructions and information in this manual and local code or
national codes, or regulations, installation and operation shall comply with the codes or
regulations in force in the country in which the equipment is installed.
DANGER
Building codes prohibit a fryer with its open tank of hot oil/shortening from being installed
beside an open flame of any type, including those of broilers and ranges.
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Receiving and
Unpacking Equipment in Section 2.7.)
CAUTION
Dean appliances equipped with legs are for stationary installations. Appliances fitted with
legs must be lifted during movement to avoid damage to the appliance and bodily injury.
For moveable installations, optional equipment casters must be used. Questions? Call 1-
800-551-8633
Dean Super Marathon and Super Runner Series gas fryers are energy efficient, tube-style, gas-fired
units. All units are shipped completely assembled with accessories packed inside the frypot. All
units are adjusted, tested and inspected at the factory before shipment. Sizes and input rates of all
models are listed in this manual.
WARNING
The on-site supervisor is responsible for ensuring that operators are made aware of
the inherent dangers of operating a hot-oil fryer/filter system, particularly the
aspects of fryer operation, oil filtration, and draining/cleaning procedures.
2.3 Principles of Operation
The incoming gas flows through orifices and is mixed with air in the burners to create the correct
ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot
light. Internal diffusers slow the flame as it goes through the burner tube. This slower and more
turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil more
efficiently.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
2-3
2.4 Rating Plate
DANGER
Fryers MUST be connected ONLY to the gas-type identified on the attached rating
plate.
The rating plate can be found on the inside panel of the fryer door. Information on this plate
includes the model and serial numbers, kW/hr (BTU/hr) of the burners, outlet gas pressure in mbars
(inches W.C.), and configuration: natural or propane gas. Rating plate data is essential for proper
unit identification, communicating with the factory or requesting special parts and/or information.
2.5 Pre-Installation
DANGER
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service
Hotline at 1-800-551-8633.
DANGER
Do not connect this appliance to the gas supply before reviewing all information in
this chapter.
A. General: Only licensed personnel should install any gas-fired equipment.
1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for
safety and ease of future service.
2. Dean Super Marathon and Super Runner Series gas fryers operate on millivolt, and do not
require an external electric power supply.
B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
certified for the following installations:
1. Commercial installation only (not for household use).
2. Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable
legs or 5-inch (13-cm) casters;
3. Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches
(15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch
(13-cm) casters.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
2-4
2.5 Pre-Installation (cont.)
C. Installation Standards
1. CE/EXPORT STANDARDS: Fryer installation must conform with local codes, or in the
absence of local codes, to the appropriate national or European Community (CE) standards.
2.6 Equipment Installed at High Altitudes
A. The fryer input rating (kW/hr) is for elevations up to 2,000 feet (610-m). For elevations above
2,000 feet (610-m), the rating should be reduced four-percent for each additional 1,000 feet (305-
m) above sea level.
B. The correct orifices are installed at the factory if the operating altitude is known at the time of the
customer’s order.
2.7 Air Supply and Ventilation
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the building.
A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be
provided in the wall above the unit, as exhaust gas temperatures are approximately 427-538°C
(800-1000°F). Check air movement during installation. Strong exhaust fans in the exhaust hood
or in the overall air conditioning system can produce slight air drafts in the room.
D. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the gas
combustion of the fryer.
E. Never
use the interior of the fryer cabinet for storage or store items on shelving over or behind
the fryer. Exhaust temperatures can exceed 427ºC (800°F) and may damage or melt items stored
in or near the fryer.
F. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge of the
filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained
between the flue(s) and the lower edge of the exhaust hood filter.
G. Filters and drip troughs should be part of any industrial hood, but consult local codes before
constructing and installing any hood. The duct system, the exhaust hood and the filter bank must
be cleaned on a regular basis and kept free of grease.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
2-5
2.8 Conversion of Units
Pressure:
1 mbar = 10,2 mm W.C. = 0,4-inch W.C.
20 mbar = 204 mm W.C. = 8-inch W.C.
1-inch W.C. = 25,4 mm W.C. = 2,5 mbar
Heat Input:
1 kW = 3410 BTU/hr
100 BTU/hr = 0,0293 kW
Temperature:
0° Celsius = 32° Fahrenheit
Temperature in degrees Celsius = (Temperature in degrees Fahrenheit (F) – 32) x 0,555
100° Celsius = (212° Fahrenheit – 32) x 0,555
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-1
3.1 Installing the Fryer
A. Initial Installation: If installed with legs, do not push against the fryer’s side to adjust its
position. Use a pallet or lift jack to lift the fryer slightly and place it where it is to be installed.
B. Relocating the Fryer: If relocating a fryer installed with legs, remove all weight from each leg
before moving.
Note: If a leg becomes damaged during movement, contact your service agent for immediate
repair/replacement.
CAUTION
Fryers may not function properly if curb mounted.
DANGER
This fryer may tip and cause personal injury if not secured correctly in a stationary
position. Drain all oil/shortening from fryer before moving. Hot oil will splash and
cause severe burns upon contact.
3.2 Leg and Caster Installation
A. General
1. Install legs and rear rigid casters near where the fryer is to be used, as neither are secure for
long transit. Unit cannot be curb mounted and must be equipped with the legs and casters
provided.
2. When positioning the fryer, gently lower the fryer into position to prevent undue strain to
the legs and internal mounting hardware. Use a pallet or lift jack to lift and position the
fryer if possible. Tilting the fryer may damage the legs.
3. The rigid casters must be installed on the fryer rear channel assembly only.
4. Proceed to Step 3.3, Leveling the Fryer, after legs and rear rigid casters are installed to
ensure the fryer is level before using.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-2
3.2 Leg and Caster Installation (cont.)
B. Leg and Rigid Caster Installation
1. Remove unit from pallet.
2. Carefully raise unit with forklift, pallet jack, or other steady means.
3. Place one lock washer on each hex head screw.
4. Insert hex head screws with lock washers [1/4-20 threads by 19 mm (¾") long] through bolt
holes of leg mounting plates and mount to the front channel. Mount rigid casters to the rear
channel following the same procedure. A locknut has been attached to the topside of the
base mounting plates at the factory to capture the hex head screw as it is screwed in.
5. Tighten the bolts to 5.65 Nm (50 inch-lbs.) torque.
CAUTION
For caster retrofit, the unit must be at room temperature and drained of shortening
before installing the casters.
3.3 Leveling the Fryer
A. Place a carpenter’s spirit level across the top of the fryer and level the unit front to back. If the
fryer is off level side to side, a platform or other surface adjustment is needed; there is no side-
to-side level adjustments on a fryer equipped with caster/leg combinations. (If a fryer is
equipped with legs only, side-to-side level adjustments can be made. If a fryer is equipped with
casters only, no level adjustments to the fryer can be made.). If the fryer is not level, the unit
may not function efficiently, the oil may not drain properly for filtering and in a multi-fryer
battery, it may not match adjacent units.
Legs (Only)
1. Adjust leg height with an adjustable or 27 mm (1-1/16-inch) open-end wrench by turning
the hex bullet on the bottom of the leg.
2. The hex bullet is for minor leg height adjustment only. Do not adjust more than 22 mm.
3. When leveling the unit, the leg body should be held firmly to keep the leg from bending or
rotating while turning the hex bullet foot to the required height.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-3
3.3 Leveling the Fryer (cont.)
Rigid Casters (Only)
1. Install the rigid casters on the fryer rear channel only. Legs must be installed on the front
channel.
2. There are no level adjustments for the rigid casters.
B. If the floor is uneven or has a decided slope, place the fryer on a smooth, level platform.
C. If the fryer is moved, re-level the fryer following the instructions given in Steps 3.3.A-C.
D. An installed fryer must be restrained to prevent tipping, which could splash hot oil. Restraints
can be straps or chains anchored to an immovable object (wall, floor anchor), or be the manner
of installation (installing the fryer in an alcove, battering to other appliances, etc.).
E. Installing Optional Swivel Casters:
1. Install non-locking casters only at the rear of the unit.
2. Locking casters must be installed at the front of the unit. Locking casters allow the fryer to
be "locked" in position for safe operations.
3. Follow the same instructions for leg installations as given above in steps 3.2, B1-5.
1/4-20 x 3/4 Hex Bolt
1/4-20 Hex Head Locknut
Washer
Leg Support Assembly
Front Channel or
Rear Channel
1/4-20 x 3/4 Hex Bolt
Front Channel
or Rear Channel
Front or Rear Leg with
Mounting Plate
Adjust as needed
Front View
Rear Side View
Rear Caster—5" Rigid
Optional Caster-
Rear Only
Front Caster—5" Swivel
w/Brake
Optional Caster-
Front Only
Leg and Caster (Optional) Mounting Installation
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-4
3.3 Leveling the Fryer (cont.)
NOTE: The installation must be inspected after it is complete to ensure it meets the intent of
these instructions. The on-site supervisor and/or operator(s) should be informed that the
appliance is installed with restraints. If restraints are removed to move fryer (cleaning
beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned
to its permanently installed position.
CAUTION
The fryer MUST be connected to the gas supply specified on the rating and serial number
plate located on the back of the fryer door.
WARNING
If gas odors are detected, the gas supply MUST be shut off at the main shut-off valve. The
local gas company or FASC should be contacted immediately to rectify the problem.
3.4 Gas Connections
Dean Super Marathon and Super Runner Series gas fryers have obtained CE markings for countries
and gas categories shown below:
Countries
Supply Pressures and Gas
(mbar)
Appliance Categories
G20 20/25
BE Belgium
G31 37
IIE(R)B3P
G20 20 I2E
DE Germany
G31 50 I3P
DK Denmark G20 20 I2H
G20 20
ES Spain
G31 37 and 50
II2H3P
G20/G25 20/25
FR France
G31 37 and 50
II2ESI3P
G20 20
GB Great Britain
G31 37
II2H3P
G20 20
GR Greece
G31 37 and 50
II2H3P
G20 20
IR Ireland
G31 37
II2H3P
IT Italy G20 20 I2H
G20/G25 20/25
LU Luxembourg
G31 50
II2E3P
G25 25
NL The Netherlands
G31 50
II2L3P
G20 20
PT Portugal
G31 37
II2H3P
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-5
3.4 Gas Connections (cont.)
NATIONAL CODE REQUIREMENTS
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation
Manual of the U.S. Food and Drug Administration.
This equipment is manufactured to use the type of gas specified on the rating plate attached to the
door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP
(Propane) gas.
DANGER
Before connecting new pipe to this appliance the pipe must be blown out thoroughly
to remove all foreign material. Foreign material in the burner and gas controls will
cause improper and dangerous operation.
The gas supply (service) line must be the same size or greater than the fryer inlet line. Dean Super
Marathon and Super Runner gas fryers are equipped with 22 mm male ISO 7.1 inlet. The gas supply
line must be sized to accommodate all gas-fired equipment connected to that gas supply. Consult
local gas companies or suppliers, or your local contractor for minimum supply line requirements.
Supply Line Specifications
The gas supply lines must be sized as indicated in the chart below, based on the total number of
fryers connected to the main gas supply.
Recommended Gas Supply Line Sizes
Gas Types Number of Fryers
1 2 to 3 4 or more (*)
Natural Gas 22 mm 28 mm 35 mm
Propane Gas 15 mm 22 mm 28 mm
(*) When exceeding 6 meters for a configuration of more than four fryers, it is necessary to
provide a 33 mm rigid gas connection.
DANGER
All connections must be sealed with a joint compound suitable for the gas being
used and all connections must be tested with a solution of soapy water before
lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-6
3.4 Gas Connections (cont.)
DANGER
"Dry-firing" your unit will cause damage to the frypot and can cause a fire. Always
ensure that melted shortening, cooking oil or water is in the frypot before firing the
unit.
Rigid Connections
Check any installer-supplied intake pipe(s) visually and clean metal particles or other foreign matter
from the threads before installing into a service line. If the intake pipes are not clear of all foreign
matter, the orifices will clog when gas pressure is applied. When using thread compound on gas
piping, use very small amounts and only on male threads. Use a pipe thread compound that is not
affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe
threads – doing so will cause clogging of the burner orifices and control valve.
Manual shut-off valve
This gas service supplier-installed valve must be installed in the gas service line ahead of the fryers
in the gas stream and in a position where it can be reached quickly in the event of an emergency.
Regulating Gas Pressure
The fryer and shut-off valve must be disconnected from the gas supply during any pressure testing of
the system.
External gas regulators are not normally required on this fryer. A safety control valve protects the
fryer against pressure fluctuations. If the incoming pressure is in excess of 3.45 kPa/35 mbar, a
step-down regulator will be required.
DANGER
When pressure-testing incoming gas supply lines, disconnect the fryer from the gas
line if the test pressure is 3,45 kPa (½" PSI, 13,84 inches W.C.) or greater to avoid
damage to the fryer’s gas piping and gas valve(s).
A. Manifold Pressure
: Your local service technician should check the manifold pressure with a
manometer.
1. Check the rating plate for manifold gas pressures. Natural gas units normally require 10
mbar, and propane units normally require 27 mbar gas pressure.
2. Confirm that the arrow forged into the bottom of the regulator body, which indicates gas
flow direction, is pointed downstream towards the fryers. The air vent cap is also part
of the regulator and should not be removed.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-7
3.4 Gas Connections (cont.)
3. If a vent line from the gas pressure regulator is used, it should be installed in accordance
with local codes or in the absence of local codes, with the appropriate national or
European Community (CE) standards.
WARNING
Use a diluted soap solution to find potentially dangerous gas leaks when making
new connections.
B. Regulators: Gas regulators can be adjusted in the field, but no adjustments should be made
unless the regulator is out of adjustment, or serious pressure fluctuations are observed.
C. Only qualified service personnel should make adjustments to the regulators.
D. Orifices: The fryer can be configured to operate on any available gas. The correct safety
control valve, appropriate gas orifices, and pilot burner are installed at the factory. While
the valve can be adjusted in the field, only qualified service personnel should make any
adjustments with the proper test equipment.
1. The following color codes indicate the type of gas to be used for each fryer and
associated components.
Gas Type CE Color Code
Natural Blue
Propane Red
E. Flexible Couplings, Connectors and Casters
1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the
installer must use a heavy-duty certified commercial flexible connector of at least 22 mm
NPT (with suitable strain-relief attachments), in compliance with local codes or in the
absence of local codes, with the appropriate national or European Community (CE)
standards. Quick-disconnect devices must comply with local codes or in the absence of
local codes, with the appropriate national or European Community (CE) standards.
2. For an appliance equipped with casters, the installation shall be made with a connector
that complies with local codes or in the absence of local codes, with the appropriate
national or European Community (CE) standards.
3. Under no circumstances are the connector and the quick-disconnect device, or its
associated piping to be used to limit fryer movement. A restraining bracket is provided on
the appliance back to prevent the unit from moving from its installed position.
/