DP6070 Temperature Meter Instruction Manual
2
DP6070 Temperature Meter Instruction Manual
3
W
ARRANTY/DISCLAIME
R
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 37 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace
period to the normal three (3) year product warranty to cover handling and shipping time. This ensures
that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be
returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized
Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is
found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to
defects resulting from any action of the purchaser, including but not limited to mishandling, improper
interfacing, operation outside of design limits, improper repair, or unauthorized modification. This
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having
been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions outside of OMEGA’s control.
Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company
will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY:
The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with
respect to this order, whether based on contract, warranty, negligence, indemnification, strict
liability or otherwise, shall not exceed the purchase price of the component upon which liability is
based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as
set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUEST/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance
and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting OMEGA:
1. Purchase Order number under which the
product was PURCHASED,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
FOR NON-WARRANTY REPAIRS, consult
OMEGA for current repair charges. Have the
following information available BEFORE contacting
OMEGA:
1. Purchase Order number to cover the COST of
the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible.
This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2012 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,
photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in
whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
DP6070 Temperature Meter Instruction Manual
4
!
CAUTION: Read complete
instructions prior to
installation and operation
of the meter.
WARNING: Risk of
electric shock or
personal injury.
Warning!
This product is not recommended for life support applications
or applications where malfunctioning could result in personal
injury or property loss. Anyone using this product for such
applications does so at his/her own risk. OMEGA shall not be
held liable for damages resulting from such improper use.
DP6070 Temperature Meter Instruction Manual
5
Table of Contents
INTRODUCTION ------------------------------------------------------------ 8
ORDERING INFORMATION --------------------------------------------- 9
SPECIFICATIONS --------------------------------------------------------- 10
General ----------------------------------------------------------------------------- 10
Temperature Input -------------------------------------------------------------- 11
Relays ------------------------------------------------------------------------------ 12
Isolated 4-20 mA Transmitter Output ------------------------------------ 13
Modbus
®
RTU Serial Communications ---------------------------------- 14
DPA1044 Digital Input & Output Expansion Module ---------------- 14
COMPLIANCE INFORMATION ---------------------------------------- 15
Safety ------------------------------------------------------------------------------- 15
Electromagnetic Compatibility --------------------------------------------- 15
SAFETY INFORMATION ------------------------------------------------ 16
INSTALLATION ------------------------------------------------------------ 17
Unpacking ------------------------------------------------------------------------- 17
Panel Mounting Instructions ------------------------------------------------ 17
Mounting Dimensions ------------------------------------------------------- 18
Configuration for 12 or 24 VDC Power Option ------------------------ 19
Connections ---------------------------------------------------------------------- 20
Connectors Labeling --------------------------------------------------------- 21
Power Connections ---------------------------------------------------------- 21
Signal Connections ---------------------------------------------------------- 22
Connections for Averaging RTD Sensors ------------------------------ 24
Modbus RTU Serial Communications ----------------------------------- 25
Relay Connections ----------------------------------------------------------- 25
Switching Inductive Loads -------------------------------------------------- 26
F4 Digital Input Connections ----------------------------------------------- 27
4-20 mA Output Connections ---------------------------------------------- 27
Analog Output Transmitter Power Supply ------------------------------ 27
External Relays & Digital I/O Connections ----------------------------- 28
Interlock Relay Feature ----------------------------------------------------- 29
SETUP AND PROGRAMMING ---------------------------------------- 30
Front Panel Buttons and Status LED Indicators --------------------- 31
Display Functions & Messages -------------------------------------------- 32
Main Menu ------------------------------------------------------------------------ 35
Setting Numeric Values ------------------------------------------------------ 36
DP6070 Temperature Meter Instruction Manual
6
Setting Up the Meter (setup) ------------------------------------------------ 37
Setting the Input Signal (Input) ------------------------------------------ 39
Selecting the Temperature Scale (F or C) ---------------------------- 39
Setting the Decimal Point (dEc pt) -------------------------------------- 39
Setting the Display Parameter & Intensity (dsplay) ----------------- 39
Display Setup Menu --------------------------------------------------------- 40
Setting the Input Units or Custom Tags (units) ---------------------- 41
Setting the Relay Operation (relay) ------------------------------------ 42
Setting the Relay Action ----------------------------------------------------- 44
Programming Set and Reset Points ------------------------------------- 45
Setting Fail-Safe Operation ------------------------------------------------ 45
Programming Time Delay -------------------------------------------------- 45
Relay Action for Loss of Input (Input Break) --------------------------- 45
DP6000-SOFT Software ---------------------------------------------------- 46
Relay and Alarm Operation Diagrams ----------------------------------- 47
High Alarm Operation (Set > Reset) ------------------------------------- 47
Low Alarm Operation (Set < Reset) -------------------------------------- 48
High Alarm with Fail-Safe Operation (Set > Reset) ------------------ 49
Low Alarm with Fail-Safe Operation (Set < Reset) ------------------- 50
Relay Alternation Control Operation ------------------------------------- 51
Relay Sampling Operation ------------------------------------------------- 52
Signal Loss or Input Break Relay Operation --------------------------- 53
Time Delay Operation ------------------------------------------------------- 54
Relay Operation Details ------------------------------------------------------ 55
Overview ------------------------------------------------------------------------ 55
Relays Auto Initialization ---------------------------------------------------- 55
Fail-Safe Operation ---------------------------------------------------------- 55
Front Panel LEDs ------------------------------------------------------------- 56
Latching and Non-Latching Relay Operation -------------------------- 56
Non-Latching Relay (Auto) ------------------------------------------------- 57
Non-Latching Relay (A-nman) --------------------------------------------- 57
Latching Relay (LatcH) ----------------------------------------------------- 57
Latching Relay (Lt-Clr) ---------------------------------------------------- 58
Acknowledging Relays ------------------------------------------------------ 58
Setting Up the Interlock Relay (Force On) Feature ------------------ 59
Scaling the 4-20 mA Analog Output (Aout) ---------------------------- 60
Reset Menu (reset) ------------------------------------------------------------ 61
Control Menu (Contrl) -------------------------------------------------------- 61
Setting Up the Password (pass) ------------------------------------------- 62
Protecting or Locking the Meter ------------------------------------------- 62
Making Changes to a Password Protected Meter -------------------- 63
Disabling Password Protection -------------------------------------------- 63
DP6070 Temperature Meter Instruction Manual
7
Advanced Features Menu ---------------------------------------------------- 64
Advanced Features Menu & Display Messages ---------------------- 65
Offset Adjust (Adjust) ------------------------------------------------------ 68
Recalibration of the Meter (t CAL) --------------------------------------- 68
Noise Filter (filter) -------------------------------------------------------- 70
Noise Filter Bypass (bypass) ---------------------------------------------- 70
Rounding Feature (round) ------------------------------------------------- 70
Modbus RTU Serial Communications (serial) ---------------------- 71
Select Menu (SElect) ------------------------------------------------------- 72
Analog Output Programming (AoutPr) ---------------------------------- 73
Programmable Function Keys User Menu (user) -------------------- 74
Internal Temperature Calibration (ICAL) -------------------------------- 75
Meter Copy Function (Copy) ----------------------------------------------- 78
METER OPERATION ----------------------------------------------------- 80
Front Panel Buttons Operation -------------------------------------------- 80
Function Keys Operation ---------------------------------------------------- 80
F4 Operation --------------------------------------------------------------------- 81
Maximum/Minimum Readings ---------------------------------------------- 81
TROUBLESHOOTING ---------------------------------------------------- 82
Diagnostics Menu (diag) ----------------------------------------------------- 82
Determining Software Version -------------------------------------------- 82
Reset Meter to Factory Defaults ------------------------------------------- 83
Factory Defaults & User Settings ----------------------------------------- 84
Troubleshooting Tips --------------------------------------------------------- 87
Alphabetical List of Display Functions & Messages --------------- 88
DP6070 Temperature Meter Instruction Manual
8
Table of Figures
Figure 1. 1/8 DIN Panel Cutout Dimensions ....................................... 17
Figure 2. Meter Dimensions - Side View ............................................. 18
Figure 3. Meter Dimensions - Top View .............................................. 18
Figure 4. Panel Mounting Details ........................................................ 19
Figure 5. Jumper Configuration for 12/24 VDC Power ...................... 19
Figure 6. Connector Labeling for Fully Loaded DP6070 ................... 21
Figure 7. Power Connections .............................................................. 21
Figure 8. Thermocouple Input Connections ...................................... 22
Figure 9. Three-Wire RTD Input Connections .................................... 23
Figure 10. Two-Wire RTD Input Connections ..................................... 23
Figure 11. Four-Wire RTD Input Connections .................................... 24
Figure 12. Average Temperature RTD Input Connections ................ 24
Figure 13. Relay Connections ............................................................. 25
Figure 14. AC and DC Loads Protection ............................................. 26
Figure 15. Low Voltage DC Loads Protection .................................... 26
Figure 16. F4 Digital Input Connections ............................................. 27
Figure 17. 4-20 mA Output Connections ............................................ 27
Figure 18. Expansion Modules & DIN Rail Mounting Kit ................... 28
Figure 19. External Relays Module Connections ............................... 28
Figure 20. Digital I/O Module Connections ......................................... 29
Figure 21. Interlock Connections ........................................................ 29
Figure 22. Acknowledge Relays w/Function Key or Digital Input .... 58
Figure 23. Meter Copy Connection ..................................................... 78
INTRODUCTION
The DP6070 meter boasts specifications and functionality that clearly makes it one
of the most advanced temperature meters available. Its dual-line 6-character
display, function keys, and optional expansion modules are only a few of the
features you will find on the DP6070.
A fully loaded DP6070 meter has the following: four SPDT relays, 4-20 mA output,
and one 24 VDC power supply to power the 4-20 mA output. The DP6070
capabilities may be enhanced by adding the following external expansion modules:
four SPST relays (creating an eight-relay temperature meter), two digital I/O modules
with four inputs and four outputs each, and USB, RS-232 or RS-485 communication
adapters.
The eight relays can be used for alarm indication or temperature control applications.
The 4-20 mA isolated output, Modbus RTU serial communications, and digital I/O
options make the DP6070 an excellent addition to any system.
DP6070 Temperature Meter Instruction Manual
9
ORDERING INFORMATION
Standard Display Models
85-265 VAC
Model
12/24 VDC
Model
Options Installed
DP6070-6R0 DP6070-7R0 No options
DP6070-6R2 DP6070-7R2 2 relays
DP6070-6R3 DP6070-7R3 4-20 mA output
DP6070-6R4 4 relays
DP6070-6R5 2 relays & 4-20 mA output
DP6070-6R7 4 relays & 4-20 mA output
Sunlight Readable Display Models
85-265 VAC
Model
12/24 VDC
Model
Options Installed
DP6070-6H0 DP6070-7H0 No options
DP6070-6H2 DP6070-7H2 2 relays
DP6070-6H3 DP6070-7H3 4-20 mA output
Accessories
Model Description
DPA1002 DIN rail mounting kit for two expansion modules
DPA1004 4 SPST (Form A) relays
DPA1044 4 digital inputs & 4 digital outputs (2 may be connected)
DPA1200 Meter copy cable
DPA1232 RS-232 serial adapter
DPA1485 RS-485 serial adapter
DPA7485-I RS-232 to RS-422/485 isolated converter
DPA7485-N RS-232 to RS-422/485 non-isolated converter
DPA8008 USB serial adapter
DPA8232-N USB to RS-232 non-isolated converter
DPA8485-I USB to RS-422/485 isolated converter
DPA8485-N USB to RS-422/485 non-isolated converter
DP6070 Temperature Meter Instruction Manual
10
SPECIFICATIONS
Except where noted all specifications apply to operation at +25°C.
General
DISPLAY
Main display: 0.60" (15 mm) high red LEDs;
Second display: 0.46" (12 mm) high red LEDs.
Both displays have six characters with leading zero
blanking. Temperature value is four or five-digit F/C, based
on configuration.
RESOLUTION
1 or 0.1 for all thermocouples and RTD inputs
DISPLAY
INTENSITY
Eight user selectable intensity levels
DISPLAY
UPDATE RATE
5/second (200 ms)
OVERRANGE
Display flashes
99999
UNDERRANGE
Display flashes
-9999
PROGRAMMING
METHODS
Four front panel buttons, digital inputs, PC and DP6000-SOFT
software, Modbus registers, or cloning using Copy function.
NOISE FILTER Programmable from 2 to 199 (0 will disable filter)
FILTER BYPASS Programmable from 0.1 to 99.9% of calibrated span
RECALIBRATION All ranges are calibrated at the factory. Recalibration is
recommended at least every 12 months.
MAX/MIN
DISPLAY
Max/min readings reached by the process are stored until
reset by the user or until power to the meter is turned off.
PASSWORD
Three programmable passwords restrict modification of
programmed settings.
Pass 1: Allows use of function keys and digital inputs
Pass 2: Allows use of function keys, digital inputs and editing set/reset points
Pass 3: Restricts all programming, function keys, and digital inputs.
NON-VOLATILE
MEMORY
All programmed settings are stored in non-volatile memory
for a minimum of ten years if power is lost.
POWER
OPTIONS
85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max
or jumper selectable 12/24 VDC 10%, 15 W max
FUSE Required external fuse: UL Recognized, 5 A max, slow
blow; up to 6 meters may share one 5 A fuse
NORMAL MODE
REJECTION
Greater than 60 dB at 50/60 Hz
ISOLATION 4 kV input/output-to-power line
500 V input-to-output
DP6070 Temperature Meter Instruction Manual
11
OVERVOLTAGE
CATEGORY
Installation Overvoltage Category II:
Local level with smaller transient overvoltages than
Installation Overvoltage Category III.
ENVIRONMENTAL Operating temperature range: -40 to 65°C
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing
CONNECTIONS Removable screw terminal blocks accept 12 to 22 AWG
wire, RJ45 for external relays, digital I/O, and serial
communication adapters.
ENCLOSURE 1/8 DIN, high impact plastic, UL 94V-0, color: black
MOUNTING 1/8 DIN panel cutout required:
3.622" x 1.772" (92 mm x 45 mm)
Two panel mounting bracket assemblies are provided.
TIGHTENING
TORQUE
Screw terminal connectors: 5 lb-in (0.56 Nm)
OVERALL
DIMENSIONS
4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm)
(W x H x D)
WEIGHT 9.5 oz (269 g)
WARRANTY 3 years parts & labor
Temperature Input
INPUTS Thermocouple: J, K, T, E, R, S, B, N, C;
RTD: 100 platinum (0.00385 & 0.00392 coefficients),
10 copper, 120 nickel, 1000 platinum (0.00385 &
0.00392 coefficients)
COLD
JUNCTION
REFERENCE
Automatic, fixed, no user calibration needed
TEMPERATURE
DRIFT
2C maximum from 0 to 65C ambient temperature
4C maximum from -20 to 0C ambient temperature
OFFSET
ADJUSTMENT
User programmable offset adjust ±50.0 degrees. This
parameter allows the user to apply an offset value to the
temperature being displayed.
INPUT
IMPEDANCE
Greater than 100 k
SENSOR BREAK
DETECTION
Open TC or RTD sensor indicated by display flashing oPEn,
relays can be programmed to go “On”, “Off”, or to “Ignore”
(Note: Ignore is detected as an upscale condition).
Analog output goes to the programmed sensor break value.
RTD
AVERAGING
Up to 10 RTDs connected in parallel can be averaged.
DP6070 Temperature Meter Instruction Manual
12
F4 DIGITAL INPUT
CONTACTS
3.3 VDC on contact. Connect normally open contacts
across F4 to COM.
F4 DIGITAL INPUT
LOGIC LEVELS
Logic High: 3 to 5 VDC
Logic Low: 0 to 1.25 VDC
Relays
RATING 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A)
external; rated 3 A @ 30 VDC and 125/250 VAC resistive
load; 1/14 HP ( 50 W) @ 125/250 VAC for inductive loads
NOISE
SUPPRESSION
Noise suppression is recommended for each relay contact
switching inductive loads; see page 26 for details.
DEADBAND 0-100% of span, user programmable
HIGH OR LOW
ALARM
User may program any alarm for high or low trip point.
Unused alarm LEDs and relays may be disabled (turn off).
RELAY
OPERATION
Automatic (non-latching)
Latching (requires manual acknowledge)
Sampling (based on time)
Relay alternation control (2 to 8 relays)
ACCURACY & RANGES
Type Range (°F) Accuracy Range (°C) Accuracy
J -200 to 2000 ±1.8°F -129 to 1093 ±1°C
K -200 to 2400 ±1.8°F -129 to 1316 ±1°C
T -200 to 752 ±1.8°F -129 to 400 ±1°C
E -200 to 1800 ±1.8°F -129 to 982 ±1°C
R -50 to 3000 ±3.6°F -46 to 1649 ±2°C
S -50 to 3000 ±3.6°F -46 to 1649 ±2°C
B 752 to 3300 ±3.6°F 400 to 1816 ±2°C
N -100 to 2300 ±3.6°F -73 to 1260 ±2°C
C 32 to 4100 ±3.6°F 0 to 2260 ±2°C
10
-328 to 500 ±0.2°F -200 to 260 ±0.1°C
100
-328 to 1562 ±0.7°F -200 to 850 ±0.4°C
120
-110 to 500 ±0.2°F -79 to 260 ±0.1°C
1000
-328 to 900 ±0.7°F -200 to 482 ±0.4°C
DP6070 Temperature Meter Instruction Manual
13
Off (disable unused relays and enable Interlock feature)
Manual on/off control mode
RELAY RESET User selectable via front panel buttons or digital inputs
1. Automatic reset only (non-latching), when the input
passes the reset point.
2. Automatic + manual reset at any time (non-latching)
3. Manual reset only, at any time (latching)
4. Manual reset only after alarm condition has cleared (L)
Note: Front panel button or digital input may be assigned to
acknowledge relays programmed for manual reset.
TIME DELAY 0 to 999.9 seconds, on & off relay time delays
Programmable and independent for each relay
FAIL-SAFE
OPERATION
Programmable and independent for each relay.
Note: Relay coil is energized in non-alarm condition.
In case of power failure, relay will go to alarm state.
AUTO
INITIALIZATION
When power is applied to the meter, relays will reflect the
state of the input to the meter.
Isolated 4-20 mA Transmitter Output
OUTPUT
SOURCE
PV (temperature), max, min, set points 1-8, Modbus PV
input, or manual control mode
SCALING RANGE 1.000 to 23.000 mA for any display range
CALIBRATION Factory calibrated 0.0 to 2000.0 = 4-20 mA output
ANALOG OUT
PROGRAMMING
23.000 mA maximum for all parameters:
Overrange, underrange, max, min, and break
ACCURACY ± 0.1% of span ± 0.004 mA
TEMPERATURE
DRIFT
0.4 µA/C max from 0 to 65C ambient,
0.8 µA/C max from -20 to 0C ambient
Note: Analog output drift is separate from input drift.
ISOLATED
TRANSMITTER
POWER SUPPLY
Terminals I+ & R: 24 VDC 10%. May be used to power the
4-20 mA output or other devices.Refer to Figure 6 on page
21 and Figure 17 on page 27.
All models rated @ 40 mA max.
EXTERNAL LOOP
POWER SUPPLY
35 VDC maximum
OUTPUT LOOP
RESISTANCE
Power supply Minimum Maximum
24 VDC
10 700
35 VDC (external)
100 1200
DP6070 Temperature Meter Instruction Manual
14
Modbus
®
RTU Serial Communications
SLAVE ID 1 – 247 (Meter address)
BAUD RATE 300 – 19,200 bps
TRANSMIT
TIME DELAY
Programmable between 0 and 199 ms
DATA 8 bit (1 start bit, 1 or 2 stop bits)
PARITY Even, Odd, or None with 1 or 2 stop bits
BYTE-TO-BYTE
TIMEOUT
0.01 to 2.54 sec
TURN AROUND
DELAY
Less than 2 ms (fixed)
Note: Refer to the Modbus Register Tables located at www.omega.com for
details.
DPA1044 Digital Input & Output Expansion Module
CHANNELS 4 digital inputs & 4 digital outputs per module
SYSTEM Up to 2 modules for a total of 8 inputs & 8 outputs
DIGITAL INPUT
LOGIC HIGH
3 to 5 VDC
DIGITAL INPUT
LOGIC LOW
0 to 1.25 VDC
DIGITAL OUTPUT
LOGIC HIGH
3.1 to 3.3 VDC
DIGITAL OUTPUT
LOGIC LOW
0 to 0.4 VDC
SOURCE
CURRENT
10 mA maximum output current
SINK
CURRENT
1.5 mA minimum input current
+5 V
TERMINAL
To be used as pull-up for digital inputs only.
Connect normally open contacts across +5 V & DI 1-4
DP6070 Temperature Meter Instruction Manual
15
COMPLIANCE INFORMATION
Safety
UL & c-UL LISTED USA & Canada
UL 508 Industrial Control Equipment
UL FILE NUMBER E356479
FRONT PANEL UL Type 4X, NEMA 4X, IP65; panel gasket provided
LOW VOLTAGE
DIRECTIVE
EN 61010-1:2001
Safety requirements for measurement, control, and
laboratory use
Electromagnetic Compatibility
EMISSIONS
EN 55022:2006/A1:2007
Class A ITE emissions requirements
Radiated
Emissions
Class A
AC Mains
Conducted
Emissions
Class A
IMMUNITY
EN 61326-1:2006
Measurement, control, and laboratory equipment
EN 61000-6-2:2005
EMC heavy industrial generic immunity standard
RFI - Amplitude
Modulated
80 -1000 MHz 10 V/m 80% AM (1 kHz)
1.4 - 2.0 GHz 3 V/m 80% AM (1 kHz)
2.0 - 2.7 GHz 1 V/m 80% AM (1 kHz)
Electrical Fast
Transients
±2kV AC mains, ±1kV other
Electrostatic
Discharge
±4kV contact, ±8kV air
RFI - Conducted
10V, 0.15-80 MHz, 1kHz 80% AM
AC Surge
±2kV Common, ±1kV Differential
Surge
1KV (CM)
Power-Frequency
Magnetic Field
3 A/m 70%V for 0.5 period
Voltage Dips
40%V for 5 & 50 periods
70%V for 25 periods
Voltage
Interruptions
<5%V for 250 periods
DP6070 Temperature Meter Instruction Manual
16
Note:
Testing was conducted on DP6070 meters installed through the
covers of grounded metal enclosures with cable shields grounded at
the point of entry representing installations designed to optimize EMC
performance.
Declaration of Conformity available at www.omega.com
SAFETY INFORMATION
!
CAUTION: Read complete
instructions prior to
installation and operation
of the meter.
WARNING: Risk of
electric shock or
personal injury.
WARNING!
Hazardous voltages exist within enclosure. Installation
and service should be performed only by trained
service personnel.
DP6070 Temperature Meter Instruction Manual
17
INSTALLATION
There is no need to remove the meter from its case to
complete the installation, wiring, and setup. Instructions
are provided for setting up a 12/24 VDC powered meter
to operate from 12 VDC power, see page 19.
Unpacking
Remove the meter from box. Inspect the packaging and
contents for damage. Report damages, if any, to the carrier.
If any part is missing or the meter malfunctions, please contact
your supplier or the factory for assistance.
Panel Mounting Instructions
Prepare a standard 1/8 DIN panel cutout – 3.622" x 1.772" (92 mm x 45 mm).
Refer to Figure 1 below, for more details.
Clearance: allow at least 6.0" (152 mm) behind the panel for wiring.
Panel thickness: 0.04" - 0.25" (1.0 mm - 6.4 mm).
Recommended minimum panel thickness to maintain Type 4X
rating: 0.06" (1.5 mm) steel panel, 0.16" (4.1 mm) plastic panel.
Remove the two mounting brackets provided with the meter (back-off the two
screws so that there is ¼" (6.4 mm) or less through the bracket. Slide the
bracket toward the front of the case and remove).
Insert meter into the panel cutout.
Install mounting brackets and tighten the screws against the panel. To
achieve a proper seal, tighten the mounting bracket screws evenly until meter
is snug to the panel along its short side. DO NOT OVER TIGHTEN, as the
rear of the panel may be damaged.
Figure 1. 1/8 DIN Panel Cutout Dimensions
3.622" (92mm)
1.772"
(45mm)
Panel Cutout
to DIN 43700
Square Corners to 0.060"
(1.5mm) Max Radius
A
B
Tolerances:
A
: +0.032 (+0.8mm)
-0.000 (-0.0mm)
B: +0.024 (+0.6mm)
-0.000 (-0.0mm)
Refer to page
18 for mounting
dimensions
DP6070 Temperature Meter Instruction Manual
18
Mounting Dimensions
Figure 2. Meter Dimensions - Side View
N
O
N
C
N
C
C
N
O
C
N
O
N
C
N
C
C
N
O
C
+
-
R
Figure 3. Meter Dimensions - Top View
DP6070 Temperature Meter Instruction Manual
19
Panel
Gasket
Mounting
Bracket
Mounting
Screw
Removable
Connectors
Figure 4. Panel Mounting Details
Configuration for 12 or 24 VDC Power Option
Warning!
Do not exceed voltage rating of the selected configuration.
Meters equipped with the 12/24 VDC power option are shipped from
the factory ready to operate from 24 VDC.
To configure the meter for 12 VDC power:
1. Remove all the connectors.
2. Unscrew the back cover.
3. Slide the back cover about 1 inch.
4. Configure the J9 jumper, located behind the power
connector, for 12 V as shown below.
MAIN BOARD
24 VDC
12 VDC
POWER
J9
12 V
24 V
J9 CONFIGURATION
Factory
Default
M-LINK
+
_
Figure 5. Jumper Configuration for 12/24 VDC Power
DP6070 Temperature Meter Instruction Manual
20
Connections
All connections are made to removable screw terminal connectors
located at the rear of the meter.
!
Use copper wire with 60°C or 60/75°C insulation
for all line voltage connections. Observe all safety
regulations. Electrical wiring should be performed
in accordance with all applicable national, state,
and local codes to prevent damage to the meter
and ensure personnel safety.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Omega DP6070 Owner's manual

Category
Motor vehicle accessories & components
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI