White Rodgers 1F95-0671 Catalog Page

Category
Thermostats
Type
Catalog Page
THERMOSTATS
BLUE 6
THERMOSTATS
BLUE 6 - UNIVERSAL COMMERCIAL AND
EASY READER THERMOSTATS - 6 SQ. IN. DISPLAY
Blue 6Models Offer More Premium Features than Higher Priced
Competitive Touchscreen Models
FEATURES
• Universalmodelsquicklycongureforsinglestage,multi-stageorheatpumpand
heatpumpduelfuelsystems-programmableornon-programmable
• Easy Reader model is easy to read and easy to use.
• Commercial offersoccupieddamperoreconomizercontrolandlockingcoverand
subbase
• Stagingcontrolfornearlyallconventionalandheatpumpsystems
• Single stage modelcompatiblewithallsinglestagesystemslowvoltage,750mV
and3-wirezonesystems.1F97-0671notpictured.
• HeatPumpdualfueloptioneliminatestheneedforafossilfuelkit.
• Automaticchangeoveroption.
• Programfanoptions.
• Keypadlockoutandsetpointtemperaturelimitoptions.
• Indoorremotesensorforaveragingoption.
• OutdoorremotesensoroptiononselectUniversalmodelsforoutdoortemperature
readinganddualfuelbalancepointoroutdoorthermostatfunction(selectmodels)
• Dualpower-hardwireand/orbatteryorTripower-hardwireand/orbatterywith
systemassist.
SPECIFICATIONS
Electrical Rating:
Hardwire ........................ 20-30VAC,NECClassII50/60Hz
BatteryPower.................... mVto30VAC,NECClassII,50/60HzorDC
Terminal Load .................... 1.5Aperterminal,
2.5Amaximumallterminalscombined
Setpoint Range................... 45to99°F(7to37°C)
RatedDifferentials,UniversalModels: Fast Slow
Heat(SingleStage/Multi-Stage) ..... 0.6°F 1.2°F
Cool(SingleStage/Multi-Stage).... 1.2°F 1.7°F
Pump ......................... 1.2°F 1.7°F
Emer.Heat..................... 1.2°F 1.7°F
RatedDifferentials-SingleStageModels:Fast Slow
Heat .......................... 0.6°F 1.2°F
Cool .......................... 1.2°F 1.7°F
OperatingAmbient................ 32to+105°F(0to+41°C)
OperatingHumidity................ 90%non-condensingmax.
Shipping Temperature Range........ -4to+150°F(-20to65°C)
Dimension....................... 4
3
/
16
Hx6
1
/
2
Wx1
5
/
8
D
(1
7
/
8
D–Commercialmodel)
PARTS AND ACCESSORIES See end of thermostats section for additional parts and accessories
• F145-1328—IndoorRemoteSensor
• F145-1378—OutdoorRemoteSensor
• F61-2600—Wallplate8
1
/
8
WX5
3
/
8
H
• F61-2634—Wallplate6
1
/
2
Wx5H(ororderF61-2648–6packofF61-2634)
• F29-0198—LockingThermostatGuard-ClearPlastic
• F29-0220—LockingThermostatGuard-Metal,SolidBase
• AdditionalThermostatGuards—seepages34–35forquickselectionoptions
F145-1328
Indoor Remote Sensor
F145-1378
Outdoor Remote Sensor
1F95EZ-0671
1F95-0671
1F95-0680
R-4425-15E
www.white-rodgers.com
14
24 VOLT
THERMOSTATS
BLUE 6
THERMOSTATS
UNIVERSAL STAGING/HEAT PUMP THERMOSTATS – BLUE 6 THERMOSTATS
Single
Stage
Multi-
Stage
Heat
Pump
Programs Model Applications
Thermostat Power Source*
Selectable Performance Features
Comfort and
Convenience
Features Terminals
Stages Heat/Cool
by System
Program
Options
Periods
Per Day
Options
Model
Number
Gas / Oil / Electric
3 Wire Zone Valve
Millivolt Compatible
Humidity Control
(H)-Humidity / (D)-Dehumidify
Auto Changeover
Programmable Fan
Energy Mgt. Recovery
Dual Fuel Heat Pump Control
(L)-Logic / (O)-Outdoor Sensor
Keypad Lockout
(T)-Total / (P)-Partial
Set-Point Temperature Limits
Adjustable Max/Min
Indoor Remote Sensors
Max. Number + Thermostat
Average and/or Weighted
Outdoor Remote Sensor
Display Size
(Square inches)
Lighted Display
Cool Savings
Memory Back-Up
(P)-Permanent / (B)-Battery
1/1 2/2 4/2 7,5+1+1,
Ø
4,2,
Ø
1F95-0680
Universal
Commercial
3 3 3
B,H,
PA
3 3 3
O
T,P
3
1+1
1t
6.0
3*** 3
P RC,RH,C,W/E,W2,
Y,Y2,O/B,G,L,6,+,
S,-,A1
1/1 2/2 4/2 7,5+1+1,
Ø
4,2,
Ø
1F95-0671
Universal
3 3 3
B,H,
PA
3 3 3
O
T,P
3
1+1
1t
6.0
3*** 3
P RC,RH,C,G,Y,Y2,
W/E,W2,O/B,L,6,
+,S,-
1/1 2/2 4/2
Ø
,7 4,2,
Ø
1F95EZ-0671
EasyReader
3 3 3
B,H,
PA
3
L
3
6.0
3*** 3
P RC,RH,C,W/E,W2,
Y,Y2,O/B,G,L,6,
* H=Hardwired(RequiresCommon)
IfF145-1378outdoorremotesensorisnotused,installmanufacturers
B,H=BatteryPoweredorHardwired fossilfuelkitforDualFuelapplications
B=BatteryPowered ***OptionalContinuousDisplayLightw/Hardwireconnection
PA=PowerSavingBatteryAssist t Onlyone(1)remotesensormaybeused–eitherIndoororOutdoor
?
PAGES
139–146
TECHNICAL HELP
1F95EZ-0671................ WiringDiagrams/Conguration..............Seepages139–140
1F95-0671.................... WiringDiagrams/Conguration..............Seepages141–143
1F95-0680.................... WiringDiagrams/Conguration.............. Seepages144–146
R-4425-15E
www.white-rodgers.com
15
24 VOLT
  • Page 1 1
  • Page 2 2

White Rodgers 1F95-0671 Catalog Page

Category
Thermostats
Type
Catalog Page

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI