6 RBE SPLIT
GB
X2 X1
X3
Connection
RBE SPLIT is installed according to the outline diagram at
the bottom of the page:
The modular cables supplied are not dependent on a
special modular connection but can be moved to the
desired location of the T-connector.
1. Open the plastic cover and connect the modular
cable between X1 on the T-connection and the free
modular connection in SPLIT (shown in the image
on the next page).
2. Connect the next modular cable between X2 on
the T-connector and any of the modular connectors
on RBE 1 SPLIT (see image to right). The modular
cable can be connected either from underneath or
straight behind.
To simplify the connection, the cover of the display
unit can be unscrewed according to ”Alternative
sensor positioning” in the next entry.
3. Connect the battery eliminator to X3 on the T-con-
nection and close the plastic cover.
4. Connect the battery eliminator to the power socket.
SPLIT
RBE SPLIT (rear side)
Outline Diagram
All electrical connections behind covers
secured by screws must be carried out by
an authorised electrician.
Electrical installation and wiring must be
carried out in accordance with the stipula-
tions in force.
Note!
T-connection
RBE SPLIT
Check that the heat pump/electric boiler/
control module is unpowered before work
is carried out behind covers secured by
screws.
Note!
15 or 3 m
3 or 15 m
1.5 m