Alpha innotec heating element control Owner's manual

Type
Owner's manual
83034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
Operating Manual
MLRH 1/3
HEATING ELEMENT CONTROL
UK
2
Contents
INFORMATION FOR USERS AND QUALIFIED
PERSONNEL
PLEASE READ FIRST .................................................................... 2
SYMBOLS .......................................................................................2
INSTALLATION OF HEATING ELEMENT LIMITER OPTIONAL ... 3
HEATING ELEMENT LIMITER .......................................................4
HEAT PUMP FUSE ......................................................................... 4
TERMINAL DIAGRAM .................................................................... 5
83034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
Information for users.
Information or instructions for qualied personnel.
DANGER!
Risk of fatal electric shock!
DANGER!
Indicates imminent danger resulting in serious injuries or death.
WARNING!
Indicates a potentially dangerous situation, which could result in serious
injuries or death.
CAUTION!
Indicates a potentially dangerous situation, which could result in
moderate or slight injuries.
ATTENTION
Indicates a potentially dangerous situation, which could result in
property damage.
NOTE
Emphasised information.
Reference to other sections of the operating manual.
Reference to other documents of the manufacturer.
Please read rst
This operating manual provides important information on handling the
unit. It is an integral part of the product and must be kept ready to hand
in the immediate vicinity of the unit. It must remain available throughout
the entire service life of the unit. It must be handed over to subsequent
owners or users of the unit.
Read this operating manual before starting any work on or with the
unit. Especially the chapter on safety. Follow all instructions in full and
unreservedly.
This operating manual may contain descriptions, which seem
incomprehensible or unclear. If you have any questions or if any details
are unclear, contact the factory customer service department or the
manufacturer's local partner.
As this operating manual has been written for several unit models,
always comply with the parameters for the respective model.
This operating manual is intended only for persons assigned to work
on or with the unit. Treat all its constituent parts condentially. They
are protected by copyright. They may not be reproduced, transmitted,
copied, stored in electronic systems or translated into another language,
either wholly or in part, without the express written permission of the
manufacturer.
Symbols
383034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
Installation of heating element limiter optional
The following applies to all work to be done:
DANGER!
Risk of fatal electric shock!
All electrical connection work must be carried out by qualied
electricians only.
Before opening the unit, disconnect the system from the
power supply and prevent it from being switched back on
again!
WARNING!
Note and follow the relevant EN, VDE and/or local safety
regulations during installation and when carrying out
electrical work.
Comply with technical connection requirements of the
responsible power supply company (if required by the latter)!
Switch cabinet
- Disconnect the load cable from the heating element at the plug-
in connections and remove the intermediate cable (is no longer
required).
- Install the limiter box so that the side of the box with the two
white plug-in connectors points upwards. Fixing material in the
separate pack. Then connect the box with the two cables (plug-
in connection):
- Plug the heating element board onto the master board I/O max
- Make the cable connection (wires 1–6) with terminal block as
described in the relevant installation instructions
4 83034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
Heating element limiter
Used optionally if the heat pump cannot be protected with the
maximum fuse
MLRH 1/3
for units 3~ 400V, 1~ 230V and 3~ 230V
Heat pump fuse
The fuses below apply to the as-delivered condition only. If
additional loads are connected to the controller the maximum fuse
must always be used. Details of the maximum fuse are given in the
technical data of the heat pump.
The heating element control setting is made in the controller, under
System Settings.
3~ 400V:
WP output C 10 C 16 C 20 C 25
4 kW 3500 W 7500 W 9000 W 9000 W
6 kW 3500 W 7500 W 9000 W 9000 W
8 kW 3000 W 7000 W 8000 W 9000 W
10 kW 2500 W 6000 W 7500 W 9000 W
12 kW x 6000 W 6500 W 9000 W
3~ 230V:
WP output C 20 C 25 C32 C 40 C 50
4 kW 2500 W 4000 W 6000 W 9000 W 9000 W
6 kW 1500 W 3000 W 5000 W 8000 W 9000 W
8 kW x 2000 W 4000 W 6500 W 9000 W
10 kW x x 2500 W 4500 W 9000 W
13 kW x x x 3000 W 7000 W
1~ 230V:
B20 B25 B32 B40 B50
3500 W 4500 W 6000 W 7500 W 9000 W
583034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
Terminal diagram
MLHR
-
-A9
-X300
-X400
-K10 -K11 -K12
Legend:
Equipement
A9
K70
X300
X400
X500
-X500
-K70
UK
Function
Heating element control
Additional heating control board
Additional heating output connector, input
Additional heating output connector, output
Additional heating control connector
831197
123 45678
12 8
A
B
C
D
E
F
A
B
C
D
E
F
Blatt
Bl.
1
1
3 4567
AIT
831197
Klemmenplan
ait-deutschland GmbH
22
44
66
99
1
1
3
3
5
5
6
5
4
3
2
1
K10 GND
2
K10 12V
1
K11 GND
4
K11 12V
3
K12 GND
6
K12 12V
5
Änderung Datum
Datum
Bearbeiter
Geprüft
NormName
04.03.2015
Pfleger
R.
12
-4 +3
12
-4 +3
12
-4 +3
6 83034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
783034500aUK– Translation into English of the original German operating manual – Subject to technical change without notice. © ait-deutschland GmbH
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Alpha innotec heating element control Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI