Generac 50kW RD05033GDAS User manual

  • Hello! I am an AI chatbot trained to assist you with the Generac 50kW RD05033GDAS User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
4 3 2 1
4 3 1
A
B
A
B
182 TYP
[7.2]
1322 TYP
[52.0]
146 [5.7]
EXHAUST
OUTLET
173 [6.8]
888 [35.0]
OVERALL WIDTH
302 [11.9]
TYP
1954 [76.9]
OVERALL LENGTH
1414 [55.7]
OVERALL
HEIGHT
897 [35.3]
DOOR WIDTH
TYP
892
[35.1]
CENTER OF GRAVITY
SEE NOTE 5
SERVICE ITEM 3.3L
OIL FILL CAP LEFT
OIL DIP STICK LEFT
OIL FILTER LEFT
OIL DRAIN HOSE RIGHT
RADIATOR DRAIN HOSE RIGHT
COOLANT RECOVERY BOTTLE RIGHT
RADIATOR FILL CAP ACCESS ROOF
AIR CLEANER ELEMENT RIGHT
MUFFLER FRONT
FAN BELT EITHER
BATTERY RIGHT
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN 894 [1971]
WITH WOODEN SHIPPING SKID 933 [2057]
TITLE
INSTALL PROTECTOR D3.3L G2
SINGLE WALL TANK
ISSUE DATE: 07/2017
SIZE CAGE NO DWG NO
10000018867
REV
B
N/A
B
SCALE
0.050
WT-KG
SEE ABOVE
SHEET
1 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
SH
1/2
REV
B
WINDCHILL VERSION
B.4
RADIATOR/EXHAUST
DISCHARGE AIR
AIR INTAKE
(BOTH SIDES)
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
REFERENCE OWNERS MANUAL FOR
PERIODIC REPLACEMENT PART LISTINGS
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
OIL DRAIN: 3/8" NPT
EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
9. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
WEIGHT: KG [LBS]
DIMENSIONS: MM [INCH]
REAR VIEW
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
REMOVABLE
STUB-UP COVER
SEE NOTE 4
RIGHT SIDE VIEW
LIFTING PROVISION (4 PLACES)
SEE NOTE 5, 8 AND CENTER
OF GRAVITY DIMENSIONS
VISE ACTION LATCH, ONE PER
DOOR, ONE LIFT-OFF DOOR
PER SIDE OF GENERATOR
LEFT SIDE VIEW
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
OPEN PUNCHED LOUVERS
TYPICAL ON BOTH SIDES
OF FUEL TANK
VENTILATION DUCT TO
PROVIDE ADEQUATE
CROSS-FLOW OF AIR
VENTILATION
TOP VIEW
BATTERY 12 VOLT
NEGATIVE GROUND
REMOVE COVER FOR
ACCESS TO RADIATOR
FILL CAP
4 3 2 1
4 3 1
A
B
A
B
850 [33.5]
125 [4.9]
*STUB-UP
AREA
125 [4.9]
*STUB-UP
AREA
786 [30.9]
38
[1.5]
51
[2.0]
253
[10.0]
62 [2.5]
1690 [66.5]
1044 [41.1]
757 [29.8]
TYP
181 [7.1]
TYP
1433 [56.4]
1556 [61.3]
112 [4.4]
TYP
19 [.7]
TYP
851 [33.5]
MOUNTING CENTERS
TYP
888 [35.0]
353 [13.9]
250 [9.9]
FUEL TANK
HEIGHT
712 [28.0]
TYP
1242 [48.9]
TYP
1842 [72.5]
TYP
1954 [76.9]
267 [10.5]
TYP
844 [33.2]
TYP
926 [36.5]
TYP
1196
[47.1]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
TITLE
INSTALL PROTECTOR D3.3L G2
SINGLE WALL TANK
ISSUE DATE: 07/2017
SIZE CAGE NO DWG NO
10000018867
REV
B
N/A
B
SCALE
0.075
WT-KG SEE ABOVE SHEET
2 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
SH
2/2
REV
B
WINDCHILL VERSION
B.4
FUEL TANK
TOTAL CAPACITY 253.6 [67]
USABLE CAPACITY 230.9 [61]
REMOVABLE
STUB-UP
COVER
SEE NOTE 4
CAPACITY: LITER [GALLONS]
DIMENSIONS: MM [INCH]
*NOTE: STUB-UP AREA FOR HIGH
AND LOW VOLTAGE CONNECTIONS,
CIRCUIT BREAKER, NEUTRAL AND
CUSTOMER CONNECTION OPENING.
REAR VIEW
16.7 [0.66]
MOUNTING HOLES
(8 PLACES) SEE
NOTE 9
LEFT SIDE VIEW
REMOVABLE COVER
TOP VIEW
HIGH AND LOW
VOLTAGE
STUB-UP AREA
EMERGENCY VENT
(2" NPT FEMALE)
NORMAL VENT
(2" NPT FEMALE)
FUEL LEVEL
GAUGE/SENDER
FUEL FILL
(2" NPT FEMALE)
FUEL SUPPLY
FUEL RETURN
/