M-system 18KBXC-K5 User manual

Type
User manual

M-system 18KBXC-K5 is a standard rack with a PI connector compatible with Yamatake DCS. It has 16 channels, each with a positive and negative terminal, and can be used for a variety of applications, including industrial automation, data acquisition, and process control. The device is designed to be used in harsh environments, with a wide operating temperature range of -5 to +55°C (23 to 131°F) and a relative humidity of 30 to 90%. It also has several built-in safety features, such as protection against overvoltage, overcurrent, and short circuits.

M-system 18KBXC-K5 is a standard rack with a PI connector compatible with Yamatake DCS. It has 16 channels, each with a positive and negative terminal, and can be used for a variety of applications, including industrial automation, data acquisition, and process control. The device is designed to be used in harsh environments, with a wide operating temperature range of -5 to +55°C (23 to 131°F) and a relative humidity of 30 to 90%. It also has several built-in safety features, such as protection against overvoltage, overcurrent, and short circuits.

P. 1 / 3
EM-0492-K5
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
18KBXC-K5
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
n PACKAGE INCLUDES:
Standard rack ...........................................................(1)
n MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
n INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
POINTS OF CAUTION
n POWER INPUT RATING & OPERATIONAL RANGE
24 V DC ±10%, 2.5 A minimum
n ENVIRONMENT
When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
Be sure that the ventilation slits are not covered with
cables, etc.
n WIRING
Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
n AND ....
The unit is designed to function as soon as power is supplied,
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
Specifications
Side
Body
MOUNTING REQUIREMENTS mm (inch)
101.6
(4.00)
*
450 (17.72)
465 (18.31)
4–M5 SCREW
ANGLE BRACKET
Observe an appropriate wiring space over and below.
*
100 (3.94)
for JIS standard
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across terminals 1
(+) – 2 (–). Use a power source of ripple level 10% p-p or
less.
3) Installation & environment: Check ambient temperature.
Also check that there are no excessive dust particles around.
Check that there is no vibration.
STANDARD RACK
(Yamatake DCS PI connector)
MODEL
18KBXC-K
5
INSTRUCTION MANUAL
P. 2 / 3
EM-0492-K5
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
18KBXC-K5
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
n EXTERNAL DIMENSIONS mm (inch)
n CONNECTION DIAGRAM
1
2
FG
3
CN1
CN2
+
POWER
FIELD TERMINALS
13 1521416 1514 16
2
1
3
+
+
96 (3.78)
38 (1.50)
2 (.08)
435 (17.13)
134 (5.28)
2 (.08)
RACK (standard) SURFACE (option /W)
465 (18.31)
480 (18.90)
CN2
CN1
1357911 13 15246810 12 14 16
150 (5.91)
101.6 (4.00)
8.5 (.33)
3-M4 POWER TERMINAL
8.2 (.32)
64−M3.5
FIELD TERMINAL*
121 2 12
343 4 34
1ch 15ch 16ch
*Field I/O Terminal Block
P. 3 / 3
EM-0492-K5
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
18KBXC-K5
n CONNECTOR PIN ASSIGNMENT
Location
Output connector: 57LE-40500-7300
CN1, CN2: PI use
18K-RACK LOCATION NO.
123456789
10 11 12 13 14 15 16
1234567812345678
YAMATAKE DCS PI CARD
(J-PIM00) INPUT
Connector Pin Assignment (CN1, CN2)
PIN NO.
(CN1)
ASSIGNMENT
PIN NO.
(CN2)
ASSIGNMENT
3ch. 1 + 3 ch. 9 +
4 ch. 1 – 4 ch. 9 –
5ch. 2 + 5 ch.10 +
6 ch. 2 – 6 ch.10 –
7ch. 3 + 7 ch.11 +
8 ch. 3 – 8 ch.11 –
9ch. 4 + 9 ch.12 +
10 ch. 4 – 10 ch.12 –
27 ch. 5 + 27 ch.13 +
26 ch. 5 – 26 ch.13 –
29 ch. 6 + 29 ch.14 +
28 ch. 6 – 28 ch.14 –
31 ch. 7 + 31 ch.15 +
30 ch. 7 – 30 ch.15 –
33 ch. 8 + 33 ch.16 +
32 ch. 8 – 32 ch.16 –
11 – 25 and 50 (CN1, CN2): Unused
1, 36, 38, 39, 41, 42, 43 and 45 in CN1 and CN2 are connected.
The output 1 is connected to the connector.
YAMATAKE DCS PI CARD
(J-PIM00) INPUT
CN1
CN2
2, 34, 35, 37, 40, 44, 46 and 47 in CN1 and CN2 are connected.
48 and 49 in CN1 and CN2 are connected.
  • Page 1 1
  • Page 2 2
  • Page 3 3

M-system 18KBXC-K5 User manual

Type
User manual

M-system 18KBXC-K5 is a standard rack with a PI connector compatible with Yamatake DCS. It has 16 channels, each with a positive and negative terminal, and can be used for a variety of applications, including industrial automation, data acquisition, and process control. The device is designed to be used in harsh environments, with a wide operating temperature range of -5 to +55°C (23 to 131°F) and a relative humidity of 30 to 90%. It also has several built-in safety features, such as protection against overvoltage, overcurrent, and short circuits.