www.desatech.com
119315-01C4
SAFETY INFORMATION
Continued
17. Operating replace above elevations of
4,500 feet could cause pilot outage.
18. Do not operate fireplace if any log is
broken. Do not operate replace if a log
is chipped (dime-sized or larger).
19. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lbs. capacity.
20. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use replace with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installa-
tion must be made by a licensed plumber
or gas tter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters
shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in
the Commonwealth of Massachusetts.
UNPACKING
CAUTION: Do not remove data
-
1. Remove replace and hood from carton.
Log is wrapped and inside replace. Do
not remove at this time.
2. Remove all protective packaging applied
to replace for shipment.
3. Make sure replace includes one hard-
ware packet.
4. Check replace for any shipping damage.
If replace is damaged, promptly inform
dealer where you bought replace.
4. This replace shall not be installed in a
bathroom.
5. Do not use this replace as a wood-burn-
ing replace. Use only the logs provided
with the replace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite or rock wool.
Using these added items can cause soot-
ing. Do not add lava rock around base.
Rock and debris could fall into the control
area of replace.
7. This replace is designed to be smokeless.
If logs ever appear to smoke, turn off re-
place and call a qualied service person.
Note: During initial operation, slight smok-
ing could occur due to log curing and re-
place burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 24.
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn replace
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
10. This replace needs fresh air ventilation to
run properly. This replace has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the re-
place if not enough fresh air is available.
See Air for Combustion and Ventilation,
page 6. If replace keeps shutting off, see
Troubleshooting, page 25.
11. Keep all air openings in front and at bottom
of heater clear and free of debris. This will
insure enough air for proper combustion.
12. Do not run replace
• where ammable liquids or vapors are
used or stored.
• under dusty conditions.
13. Do not use this replace to cook food or
burn paper or other objects.
14. Never place any objects in the replace
or on logs.
15. Do not use replace if any part has been
under water. Immediately call a qualied
service technician to inspect the room
replace and to replace any part of the
control system and any gas control which
has been under water.
16. Turn off fireplace and let cool before
servicing. Only a qualied service person
should service and repair replace.