Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
1
1. Introdution ..........................................................................2
2.
Cautions.............................................................................3
3. Overview ............................................................................4
4. Package contents...............................................................6
5. Wiring and Installation ........................................................7
6. Specification ......................................................................9
Contents
2
1. Introduction
The model number is located on the bottom. Please record the serial number in the space provided below.
Refer to these numbers whenever you call upon your COMMAX dealer regarding this product.
Model No. Serial No.
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
This symbol is intended to alert the use of uninsulated “dangerous Voltage” within the product that may cause the insufficient
magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the use to the presence of important operating and maintenance(servicing) instructions in the
literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock, do not remove cover (or back cover) no user-
serviceable part inside. Refer service to the service personnel
caution
Risk of electric shock
do not open
3
2.
Cautions
Do not install it to extremely
hot or cold places.
Do not install it under humid
environment.
Do not install it to the
flickering place.
Do not install it to the place
where it will be exposed to oil
and gas.
If used at a place where the
temperature is higher than
40 or lower than -10 ,
it may cause deterioration of
image quality or failure.
Pay attention to the
ventilation, especially when
installing in a hot place.
Installing in a humid place will
cause deterioration of the lens
and cause low quality image.
Malfunctions may occur in high
illumination changing areas,
such as unstably flickering
lightings.
Malfunctions may occur
when oil or gas permeate
to the products.
4
3. Overview
5
Microphone : Deliver voice signal from a visitor
* Make sure the lens is always kept clean
Speaker : Deliver voice signal to a visitor
Call Button : Pressed to call to a household
Angle Adjustment Lever : Adjust lens angle
Volume Adjuster : Adjust speaker volume
Monitor Connection Terminal (Polarity with care)
Door Release Connection Line
White LED & Illumination Sensor : Offer clear image at night
Camera Lens : Transfer image
Button Lighting : When you call the household, the lights turn on.
6
4.
Package contents
Entrance Camera
(DRC-40YFD)
Mounting Bracket
Manual
GH1T 4x18(2EA)
Bracket Fixing Screw
PHM 3x8(1EA)
Camera Fixing Screw
Connector
(4Px200)
Volume Sheet
(Used to prevent holes after adjusting the volume.)
5. Wiring and Installation
7
1. Match the fix the whole in the wall and the fixing bracket [FIG.1]
2. Match and connect monitor line as shown below [FIG.2]
(#1: Audio, #2: GND, #3: DC12V, #4: Video)
3. Adjust camera location on the wall by checking the image on monitor screen and
fix its location
4. Connect the Door Release Connection Line as shown below [FIG.2]
5. Tighten a screw at the bottom side of the camera [FIG.1]
2nd DOOR
RELEASE
[FIG.1]
[FIG.2]
SCREW PHM 3x8 (1EA)
SCREW GH1T 4x18 (2EA)
8
UU
Installation place
Do not install the product where direct lays of the sun reach the camera lens.
Adjust the position by using the angle adjustor (in the back).
Install a separate lighting at night for better picture quality.
Cautions at a time of installation
1. Do not install where there is much dust, waste or humidity.
2. Make sure to connect accurately.
3. Make sure to fix it tightly so that it does not come off due to vibration.
4. Avoid places where there are direct lays of the sun or where it rains a lot.
5. Take good care of it to prevent dust or cracks on the window of the door camera lens.
Position of camera
6. Specification
DRC-40YFD
DC 12V (Supplied from monitor)
4 wires to a monitor (polarity)
2 wires to the DOOR1 release (non-polarity)
3 wires to the 2nd DOOR release
(YEL:COM, BLUE:N/O, RED:N/C)
CMOS 2.0 megapixel (AHD)
NTSC or PAL STANDARD.
Simultaneous communication
0.1 Lux (within 300mm)
13
Up, down 12 Degrees
-10°C(tested up to -40°C) ~ +40°C
400g
Diameter (pie)
Diameter (meter)
Model No.
Rated Voltage / Power Consumption
Sensor Type
Video Transmission Standard
Communication
Minimum Illumination
LED
Angle Adjustment
Operating Temperature
Weight (g)
Dimension (mm)
Distance between a door
camera and monitor
Wiring (Main Unit / Door Release)
0.5 0.65 0.8
28m 50m 70m
9
106.8(W) x 165.0(H) x 50.4(D)
(Rain Shield Integrated Type)
Embedded night LED (activated at night)
Effective Viewing Angle
Printed In Korea / 2014.03.105
PM1040KR2010
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133
Web site : www.commax.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Commax DRC-40YFD · 40YHD·40YV Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

Other documents