GROHE 31055ZB0 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

D
.....1
NL
.....6
PL
.....11
P
.....16
BG
.....21
CN
.....26
GB
.....2
S
.....7
UAE
.....12
TR
.....17
EST
.....22
UA
.....27
F
.....3
DK
.....8
GR
.....13
SK
.....18
LV
.....23
RUS
.....28
E
.....4
N
.....9
CZ
.....14
SLO
.....19
LT
.....24
I
.....5
FIN
...10
H
.....15
HR
.....20
RO
.....25
DESIGN + ENGINEERING
GROHE GERMANY
www.grohe.com
31 055
BRIDGEFORD
96.309.131/ÄM 230463/07.14
D
.....1
NL
.....2
PL
.....4
P
.....6
BG
.....7
CN
.....9
GB
.....1
S
.....3
UAE
.....4
TR
.....6
EST
.....8
UA
.....9
F
.....1
DK
.....3
GR
.....5
SK
.....6
LV
.....8
RUS
...10
E
.....2
N
.....3
CZ
.....5
SLO
.....7
LT
.....8
I
.....2
FIN
.....4
H
.....5
HR
.....7
RO
.....9
English .....1
Français .....2
Español .....3
I
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Entregue estas instrucciones al usario final de la grifería!
Please pass these instructions on to the end user of the fitting!
1
English
Application
Operation is possible in conjunction with:
Pressurized storage heaters
Operation is not possible with:
Low-pressure storage heaters (displacement water heaters)
Specifications
Max. flow 6.6 L/min or 1.75 gpm/60psi
Flow pressure
- min. 7.25 psi
- recommended 14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure reducing valve
Max. operating pressure 145 psi
Test pressure 232 psi
Temperature
- max. (hot water inlet) 158 °F
- thermal desinfection possible max. 194 °F
Water connection cold on right side
hot on left side
Deck thickness max. 2 3/8“
Notes:
- Major pressure differences between cold and hot water
supply should be avoided.
- To be installed according to local codes and regulations.
Installation
Flush piping system prior and after installation of faucet
thoroughly!
Prepare sink faucet
Refer to the dimensional drawing on fold-out page I.
Mount sink faucet
1.Fit swivel spout. Swivel range can be adjusted by means of
stop (A), see fold-out page III, Fig. [1].
2.Slide on escutcheon (B), see Fig. [2].
3.Fit O-ring (C) and insert faucet into sink.
4.Fit brace (D), if necessary, with seal (E), flange (F) and
connect nut (G).
Note:
If brace (D) is omitted, deck thickness can be increased
by 9/16" to a total of 2 3/8".
Connect sink faucet, see Figs. [2] and [3].
For this purpose the supply must be connected to the angle
stops (or other supply points).
The cold water supply should be connected on the right, the
hot water supply on the left side.
Mount lever (18 244) or handle (18 733), sold separately, see
Fig. [4].
1.Insert O-ring (I1) into escutcheon (I).
2.Screw the ring (H) into the escutcheon (I) until tight.
Hand tighten only!
3.Push on lever (J) or handle (K).
4.Tighten with screw (L) and screw in cover cap (M).
Open cold and hot water supply and check connections
for leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off cold and hot water supply!
I. Replacing the ceramic cartridge, see Fig. [5].
1.Unscrew cover cap (M) and remove screw (L).
2.Pull off lever (J) or handle (K) and unscrew ring (H) .
3.Unscrew escutcheon (I) with O-ring (I1).
4.Unscrew ceramic cartridge (N) using a 17mm socket
wrench.
5.Change complete ceramic cartridge (N) or O-ring (O).
Observe the different replacement part numbers of the
ceramic cartridges, see fold-out page II.
Observe the correct installation position!
Assemble in reverse order.
II. Unscrew and clean flow straightener (13 931), see fold-out
page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( ° = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
2014/03/21
www.grohe.com
D
&
+49 571 3989 333
impressum@grohe.de
A
&
+43 1 68060
info-at@grohe.com
AUS
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
B
&
+32 16 230660
info.be@grohe.com
BG
&
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
&
+99 412 497 09 74
CDN
&
+1 888 6447643
CH
&
+41 448777300
CN
&
+86 21 63758878
CY
&
+357 22 465200
CZ
&
+420 277 004 190
grohe-cz@grohe.com
DK
&
+45 44 656800
E
&
+34 93 3368850
EST
&
+372 6616354
F
&
+33 1 49972900
marketing-fr@grohe.com
FIN
&
+358 10 8201100
teknocalor@teknocalor.fi
GB
&
+44 871 200 3414
GR
&
+30 210 2712908
nsapountzis@ath.forthnet.gr
H
&
+36 1 2388045
HK
&
+852 2969 7067
I
&
+39 2 959401
IND
&
+91 124 4933000
IS
&
+354 515 4000
J
&
+81 3 32989730
KZ
&
+7 727 311 07 39
LT
&
+372 6616354
LV
&
+372 6616354
grohe@grohe.ee
MAL
&
+1 800 80 6570
info-singapore@grohe.com
N
&
+47 22 072070
grohe@grohe.no
NL
&
+31 79 3680133
NZ
&
+09/373 4324
P
&
+351 234 529620
PL
&
+48 22 5432640
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
info-ro@grohe.com
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
SGP
&
+65 6 7385585
info-singapore@grohe.com
SK
&
+420 277 004 190
T
&
+66 2610 3685
info-singapore@grohe.com
TR
&
+90 216 441 23 70
UA
&
+38 44 5375273
info-ua@grohe.com
USA
&
+1 800 4447643
us-customerservice@grohe.com
VN
&
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL
HR
KS
ME
MK
SLO
SRB
&
+385 1 2911470
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
&
+357 22 465200
IR
OM
UAE YEM
&
+971 4 3318070
grohedubai@grome.com
Far East Area Sales Office:
&
+65 6311 3600
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GROHE 31055ZB0 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI