Chauvet Professional Nexus 2x2 Reference guide

Category
Floodlights
Type
Reference guide

This manual is also suitable for

Nexus™ 2x2 QRG EN
2
About this
Guide
The Nexus™ 2x2 Quick Reference Guide (QRG) has basic product
information such as connection, mounting, menu options, and DMX values
.
Download the User Manual from www.chauvetlighting.com for more
details.
Disclaimer
The information and specifications contained in this QRG are subject to
change without notice.
Safety Notes
DO NOT open this product. It contains no user-serviceable parts.
DO NOT look at the light source when the product is on.
CAUTION: This product’s housing may be hot when lights are
operating.
Mount this product in a location with adequate ventilation, at least 20
in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product
while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT hang product using only the coffin locks.
DO NOT operate this product outdoors or in any location where dust,
excessive heat, water, or humidity may affect it.
DO NOT operate this product if the housing, lenses, or cables appear
damaged.
DO NOT connect this product to a dimmer or rheostat.
ONLY connect this product to a grounded and protected circuit.
ONLY use the hanging/mounting bracket to carry this product.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperature is 104 °F (40 °C). Do not operate
this product at higher temperatures.
Contact
Outside the U.S., United Kingdom, or Ireland, contact your distributor to
request support or return a product. Visit www.chauvetlighting.com
for
contact information.
What Is
Included
Nexus™ 2x2
Power Input Cord
5 mm Allen Key
Floor Bracket
Warranty Card
Quick Reference Guide
EN Nexus™ 2x2 QRG
3
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100 to 240 VAC, 50/60 Hz.
Power Linking
You can link up to 15 Nexus™ 2x2 products at 120 VAC or
28 at 230 VAC. Never exceed this number. Power linking cords can be
purchased separately.
Power Linking
Diagram
AC Plug
Connection
Wire (Europe)
Screw Color
AC Live
Brown
Yellow/Brass
AC Neutral
Blue
Silver
AC Ground
Green/Yellow
Green
Replacing the
Fuse
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from
the housing. (T2A 250V)
3. Remove blown fuse and replace with a good fuse of the same type
and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Nexus™ 2x2 will work with a DMX controller using a regular DMX
serial connection. A DMX Primer is available from www.chauvetpro.com.
DMX Connection
The Nexus™ 2x2 uses a regular DMX data for its DMX personalities:
3, 5, 9, 12, and 17. See the User Manual to connect and
configure for DMX
operation.
Master/Slave
Connection
The Nexus™ 2x2 uses the DMX data connection for its Master/Slave
mode. See the User Manual to connect and configure for Master/Slave
operation.
Nexus™ 2x2 QRG EN
4
Art-Net™
Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP to transfer large
amounts of DMX512 data over a large network. Art-Net™
uses the
Neutrik® etherCON® connection. An Art-Net™ protocol document
is
available from www.chauvetpro.com. Art-
Net™ is Designed by and
Copyright Artistic Licence Holdings Ltd.
Kling-Net
Connection
Kling-Net is a network protocol to allow auto configuration of display
devices over Ethernet. Kling-Net uses the Neutrik® etherCON®
connection.
Refer to the ArKaos MediaMaster™ software manual for
detailed instructions on programming this product using this protocol.
Art-Net™/Kling-
Net
Connection Diagram
Factory Reset
This procedure allows you to reset the product to its original factory
settings.
1. Unplug the Nexus™ 2x2 from power.
2. Press and hold the <MENU/ESC> and <ENTER> buttons
simultaneously while plugging the Nexus™ 2x2 back into power.
3. Release the <MENU/ESC> and <ENTER> buttons.
NOTE: Do not use WAN port!
Computer/Controller
(running Kling-Net
or Art-Net protocol)
Router
To other
Kling-Net or
Art-Net™
Devices
EN Nexus™ 2x2 QRG
5
Mounting
The Nexus™ 2x2 may be mounted in almost any orientation provided each
individual product is secured through the mounting bracket. The coffin
locks are for product alignment only and are not
weight bearing. DO NOT
hang product using only the coffin locks.
Product
Mounting
Diagram
Control Panel
Description
Button
Function
<MENU/ESC>
Scrolls through the main menu or exits from the current
menu or function
<ENTER>
Enables the currently displayed menu or sets the currently
selected value into the selected function
<UP>
Navigates upwards through the menu list and increases the
numeric value when in a function
<DOWN>
Navigates downwards through the menu list and decreases
the numeric value when in a function
Coffin Lock
Overhead Mounting
Floor Mounting
Nexus™ 2x2 QRG EN
6
Menu Options
Main Level
Programming Levels
Description
Auto Show
Auto 1~11
Show Speed
000~100
11 automatic programs
Fade
Cross-fading color scroll
Static
Fixture Color
R
7 preset colors
G
B
GB
RB
RG
RGB
Manual Color
R
000~255
Combine Red, Green, and Blue, to
generate a custom color (0~100%)
G
B
Dimmer Mode
Off
Dimming curve
Dimmer 1~3
Back Lite
On
Sets the amount of time control panel
backlight stays on
10S
20S
30S
Info
Fixture Hours
Shows the amount of time the product
has been in use
Version
Shows the software version installed
IP Address
Shows the products IP address
Device ID
Shows the products Kling-Net ID number
DMX Address 001~512
Sets products DMX Address/Art-Net™
start channel
DMX Channel
3Ch
3-Channel mode
5Ch
5-Channel mode
9Ch
9-Channel mode
12Ch
12-Channel mode
17Ch
17-Channel mode
Master/Slave
Master
Selects Master mode
Slave
Selects Slave mode
White
R
125~255
Defines the color temperature used when
RGB faders are at 100%
G
B
Fan Speed
Auto
Product determines fan speed
High
Fan speed is set to highest setting
Temperature
Shows the product internal temperature
Ethernet Settings Protocol
Kling-Net
Product uses Kling-Net protocols
Art-Net
IP Mode
DHCP
Router provides the IP address
Static
Uses the products pre-configured IP
address
Net 000~127
For use with consoles running
Art-Net™ 3
Subnet
00~15
For use when addressing Art-Net™
Universe
EN Nexus™ 2x2 QRG
7
DMX Values
17 Ch
Channel
Function
Value
Percent/Setting
1
Red 1
000 ó 255
0~100%
WW 1
When values 011-020 in CH. 17 are
activated
2
Green 1
000 ó 255
0~100%
CW 1
When values 011-020 in CH. 17 are
activated
3
Blue 1
000 ó 255
0~100%
4
Red 2
000 ó 255
0~100%
WW 2
When values 011-020 in CH. 17 are
activated
5
Green 2
000 ó 255
0~100%
CW 2
When values 011-020 in CH. 17 are
activated
6
Blue 2
000 ó 255
0~100%
7
Red 3
000 ó 255
0~100%
WW 3
When values 011-020 in CH. 17 are
activated
8
Green 3
000 ó 255
0~100%
CW 3
When values 011-020 in CH. 17 are
activated
9
Blue 3
000 ó 255
0~100%
10
Red 4
000 ó 255
0~100%
WW 4
When values 011-020 in CH. 17 are
activated
11
Green 4
000 ó 255
0~100%
CW 4
When values 011-020 in CH. 17 are
activated
12
Blue 4
000 ó 255
0~100%
13 Auto Programs
000
ó
010
011 ó 029
030 ó 048
049 ó 067
068 ó 086
087 ó 104
105 ó 123
124 ó 142
162 ó 161
180 ó 179
199 ó 198
199 ó 217
218 ó 236
237 ó 255
No Function
Auto 1
Auto 2
Auto 3
Auto 4
Auto 5
Auto 6
Auto 7
Auto 8
Auto 9
Auto 10
Auto 11
Fade
Auto 1~11
14 Auto Speed
000 ó 255
Only when values 011~255 in CH. 13
are activated
15
Dimmer
000 ó 255
0~100%
16 Strobe
000 ó 010
011 ó 255
No Function
0~30 Hz
Nexus™ 2x2 QRG EN
8
DMX Values (Cont.)
17 Ch
(Cont.)
Channel
Function
Value
Percent/Setting
17 Dimmer Speed
000 ó 010
011 ó 020
021 ó 030
031 ó 051
052 ó 101
102 ó 152
153 ó 203
204 ó 255
Preset dimmer speed from display menu
WW/CW Mode On (hold for 5 sec.)
WW/CW Mode Off (hold for 5 sec.)
No Function
Linear dimmer
Nonlinear dimming curve 1 (fastest)
Nonlinear dimming curve 2
Nonlinear dimming curve 3 (slowest)
12 Ch
Channel
Function
Value
Percent/Setting
1
Red 1
000 ó 255
0~100%
2
Green 1
000 ó 255
0~100%
3
Blue 1
000 ó 255
0~100%
4
Red 2
000 ó 255
0~100%
5
Green 2
000 ó 255
0~100%
6
Blue 2
000 ó 255
0~100%
7
Red 3
000 ó 255
0~100%
8
Green 3
000 ó 255
0~100%
9
Blue 3
000 ó 255
0~100%
10
Red 4
000 ó 255
0~100%
11
Green 4
000 ó 255
0~100%
12
Blue 4
000 ó 255
0~100%
9 CH
Channel
Function
Value
Percent/Setting
1
Dimmer
000 ó 255
0~100%
2
Red
000 ó 255
0~100%
WW
When values 011-020 in CH. 9 are activated
3
Green
000 ó 255
0~100%
CW 1
When values 011-020 in CH. 9 are activated
4
Blue
000 ó 255
0~100%
5 Strobe
000 ó 009
010 ó 255
No Function
0~30 Hz
6
Color Macro +
White Balance
000 ó 010
011 ó 030
031 ó 050
051 ó 070
071 ó 090
091 ó 110
111 ó 130
131 ó 150
151 ó 170
171 ó 200
201 ó 205
206 ó 210
211 ó 215
216 ó 220
221 ó 225
226 ó 230
231 ó 235
236 ó 240
241 ó 245
246 ó 250
251 ó 255
No Function
R: 100% G: 0~100% B: 0
R: 100%~0 G: 100% B: 0
R: 0 G: 100% B: 0~100%
R: 0 G: 100%~0 B: 100%
R: 0~100% G: 0 B: 100%
R: 100% G: 0 B: 100%~0
R: 100% G: 0~100% B: 0~100%
R: 100%~0 G: 100%~0 B: 100%
R: 100% G: 100% B: 100%
White 1
White 2
White 3
White 4
White 5
White 6
White 7
White 8
White 9
White 10
White 11
EN Nexus™ 2x2 QRG
9
DMX Values (Cont.)
9 CH
(Cont.)
Channel
Function
Value
Percent/Setting
7 Auto Programs
000 ó 010
011 ó 029
030 ó 048
049 ó 067
068 ó 086
087 ó 104
105 ó 123
124 ó 142
162 ó 161
180 ó 179
199 ó 198
199 ó 217
218 ó 236
237
ó
255
No Function
Auto 1
Auto 2
Auto 3
Auto 4
Auto 5
Auto 6
Auto 7
Auto 8
Auto 9
Auto 10
Auto 11
Fade
Auto 1~11
8 Auto Speed
000 ó 255
Only when values 011~255 in CH. 7 are
activated
9 Dimmer Speed
000 ó 010
011 ó 020
021 ó 030
031 ó 051
052 ó 101
102 ó 152
153 ó 203
204 ó 255
Preset dimmer speed from display menu
WW/CW Mode On (hold for 5 sec.)
WW/CW Mode Off (hold for 5 sec.)
No Function
Linear dimmer
Nonlinear dimming curve 1 (fastest)
Nonlinear dimming curve 2
Nonlinear dimming curve 3 (slowest)
5 CH
Channel
Function
Value
Percent/Setting
1
Dimmer
000 ó 255
0~100%
2
Red
000 ó 255
0~100%
3
Green
000 ó 255
0~100%
4
Blue
000 ó 255
0~100%
5
Strobe
000 ó 010
011 ó 255
No Function
0~30 Hz
3 CH
Channel
Function
Value
Percent/Setting
1
Red
000 ó 255
0~100%
2
Green
000 ó 255
0~100%
3
Blue
000 ó 255
0~100%
Nexus™ 2x2 QRG Multi-Language
Nexus2X2 QRG, Rev. 2 ML│ © Copyright 2013 CHAUVET® │All rights reserved. Printed in P. R. C.
Contact Us
World Headquarters
CHAUVE
General Information
Address: 5200 NW 108th Avenue
Sunrise, FL 33351
Voice: (954) 577-4455
Fax: (954) 741-5571
Toll free: (800) 762-1084
United Kingdom and Ireland
CHAUVET® Europe Ltd.
General Information
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0)1773 511115
Fax: +44 (0)1773 511110
Technical Support
Voice: (954) 577-4455 (Press 4)
Fax: (954) 756-8015
Email: tech@chauvetlighting.com
Technical Support
Email: uktech@chauvetlighting.com
World Wide Web
www.chauvetlighting.com
World Wide Web
www.chauvetlighting.co.uk
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Chauvet Professional Nexus 2x2 Reference guide

Category
Floodlights
Type
Reference guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI