InstructionManual
Pleasereadtheseinstructionscarefullybeforeusingthe
instrumentandkeeptheminasafeplace.
TheMicrolifeEarThermometerisahighqualityproductincorporating
thelatesttechnologyandtestedinaccordancewithinternational
standards.Withitsuniquetechnology,thisthermometercanprovide
astable,heat-interference-freereadingwitheachmeasurement.The
instrumentperformsaself-testeverytimeitisswitchedontoalways
guaranteethespecifiedaccuracyofmeasurements.
TheMicrolifeEarThermometerisintendedfortheperiodicmeasure-
mentandmonitoringofhumanbodytemperature.Itisintendedfor
useonpeopleofallages.
Pleasereadthroughtheseinstructionscarefullysothatyouunder-
standallfunctionsandsafetyinformation.
Table of Contents
1. The Advantages of this Ear Thermometer
2. Important Safety Instructions
3. Product Description
4. How this Thermometer Measures Ear Temperature
5. Control Displays and Symbols
6. How to Reload a New Probe Cover
7. Directions for Use
8. Changing from Fahrenheit to Celsius and vice-versa
9. How to recall 12 readings in Memory Mode
10. Cleaning and Storage
11. Error Messages
12. Replacing the Battery
13. Guarantee
14. Technical Specifications
15. www.microlife.com
EN
EN
2
1. The Advantages of this Ear Thermometer
Multiple Use (Wide Range Measurement)
Thisthermometeroffersawidemeasurementrangefeaturefrom
0°Cto100.0°C/32.0°Fto212.0°F,meaningtheunitcanbeused
asanearthermometertomeasurebodytemperatureoritcanbe
usedtomeasuresurfacetemperatureofthefollowing:
• Milksurfacetemperatureinababy’sbottle
• Surfacetemperatureofababy’sbath
• Ambienttemperature
Measurement in 1 second
Theinnovativeinfraredtechnologyallowsmeasurementofeartempe-
ratureinonly1second.
Accurate and reliable
Theuniqueprobeassemblyconstruction,incorporatinganadvanced
infraredsensor,ensuresthateachmeasurementisaccurateand
reliable.
Gentle and Easy to Use
• Theergonomicdesignenablessimpleandeasyuseofthe
thermometer.
• Thisthermometercanevenbeusedonasleepingchild,thereby
causingnodisruption.
• Thisthermometerisquick,thereforechild-friendly.
Auto-Display Memory
Thelastreadingisautomaticallydisplayedfor2secondswhenthe
unitisswitchedON.
Multiple Reading Recalls
Userswillbeabletorecallthelast12readingswhenenteringtherecall
mode,enablingefficienttrackingoftemperaturevariations.
Safe and Hygienic
• Noriskofbrokenglassormercuryingestion.
• Completelysafeforuseonchildren.
• Disposableprobecoversmakethisthermometercompletely
hygienicforusebythewholefamily.
Fever Alarm
10shortbeepsandaredLCDbacklightalertthepatientthathe/she
mayhaveatemperatureequaltoorhigherthan37.5°C.
3
2. Important Safety Instructions
• Thisinstrumentmayonlybeusedforthepurposesdescribedin
thisbooklet.Themanufacturercannotbeheldliablefordamage
causedbyincorrectapplication.
• AlwaysusethethermometerwithanewundamagedProbeCover
foreachmeasurementtopreventinfection.OnlyMicrolifebranded
probecoverscanensurethatyougetanaccuratemeasurement.
Never immerse this instrument in water or other liquids.
For cleaning please follow the instructions in the «Cleaning
and Disinfecting» section.
• Donotusetheinstrumentifyouthinkitisdamagedornotice
anythingunusual.
• Neveropentheinstrument.
• Earwaxintheearcanalmaycause alowertemperature reading.
Thereforeitisimportanttoensurethesubject’searcanalisclean.
• Thisinstrumentcomprisessensitivecomponentsandmustbe
treatedwithcaution.Observethestorageandoperatingcondi-
tionsdescribedinthe«TechnicalSpecifications»section.
• Protectitaswellastheprobecoversfrom:
-extremetemperatures
-impactanddropping
-contaminationanddust
-directsunlight
-heatandcold
• Iftheinstrumentisnotgoingtobeusedforaprolongedperiod
thebatteriesshouldberemoved.
• Ensurethatchildrendonotusetheinstrumentunsupervised;
somepartsaresmallenoughtobeswallowed.
WARNING:
Useofthisinstrumentisnotintendedasasubstituteforconsultation
with your physician. This instrument is NOT waterproof so do not
immerseinliquids.
EN
4
3. Product Description
(1) Probe Cover
(2) Probe
(3) Start button
(4) LCD Display
(5) O/I button
(6) Battery Cover
4. How this Ear Thermometer Measures Ear Temperature
Thisthermometermeasuresinfraredenergyradiatedfromtheeardrum
andthesurroundingtissue.Thisenergyiscollectedthroughthelens
andconvertedtoatemperaturevalue.Themeasuredreadingobtained
directlyfromtheeardrum(TympanicMembrane)ensuresthemost
accurateeartemperature.
Measurementstakenfromthesurroundingtissueoftheearcanalgene-
ratelowerreadingsandmayresultinmisdiagnosisoffever.
To avoid an inaccurate measurement:
• Firstsliponaprobecover.
• SwitchonthethermometerbypressingtheO/Ibutton.
• Afteronebeepisheard(andthetemperaturescaleiconisflashing),
straightentheearcanalbygentlypullingthemiddleoftheearback
andup.
• Placetheprobefirmlyintotheearcanal,presstheSTARTbutton
and keep the probe in the ear until the thermometer beeps to
signalthecompletionofthemeasurement.
This thermometer has been clinically tested and proven to be
safe and accurate when used in accordance with its opera-
ting instruction manual.
(2)
(3)
(4)
(5)
(6)
(1)
5
5. Control Displays and Symbols
LCD Display Display
Meaning
Description
Allsegments
displayed
PresstheO/Ibuttontoturn
ontheunit,allsegments
willbeshownfor2seconds.
Memory Thelastreadingwillbe
shownonthedisplayauto-
maticallyfor2seconds.
Ready Theunitisreadyformea-
surement,the«°C»or «°F»
iconwillkeepflashing.
Measurement
complete
Thereadingwillbeshown
onthedisplaywiththe
«°C»or«°F»iconsteady,
theunitisreadyforthe
nextmeasurement,when
the «°C»or«°F»iconis
flashingagain.
Out-of-ear
temperature
indication
Acrossed-ear-iconisshown
ontheLCDifthereading
fallsoutsidetherange32.0
~42.2°C(89.6~108.0°F).
Lowbattery
indication
Whentheunitisturnedon,
thebatteryiconwillkeep
flashingtoremindtheuser
toreplacethebattery.
EN
6. How to Reload a New Probe Cover
NOTE:
• Inordertoavoidcross-contamination,pleasereloadanewprobe
coverforeachmeasurement.
• Pleasecheckiftheprobecoverisfittedonfirmlybeforeuse
(please see the diagrams below);Iftheprobecoverisbroken,
discardtheprobecoverandreloadanewoneimmediately.
(X) Incorrect (O) Correct
6
(3) Completelypushthe
probeintotheprobe
coverholderhole.
(4) Takeouttheprobewith
coverattachedtightly.
(1) Placeaprobecoveronto
thestoragecasehole
withpapersideupwards.
(2) Taketheunit,vertically
penetratetheprobeinto
the centerpartofthe
probecover.
7
7. Directions for Use
Important: Prior to every measurement, fit a new undamaged Probe
Coveronthe measuringprobe.Failure todosomay resultinincorrect
temperaturemeasurement.
1. PresstheO/Ibutton.Thedisplayisactivated
toshowallsegmentsfor2seconds.
2. Thelastmeasurementreadingwillautomati-
callybeshownonthedisplayfor2seconds
withthe«M»icon.
3. Whenthe «°C»or«°F»iconisflashing,a
beepsoundisheardandthethermometeris
readyformeasurement.
4. Straightentheearcanalbypullingtheearupandbacktogivea
clearviewoftheeardrum.
• Forchildrenunder1year;pulltheearstraight
back.
• Forchildrenof1yeartoadult;pulltheearup
andback.
Alsorefertotheshortinstructionsatthefront.
5. Whilegentlypullingtheear,insertthe
probesnuglyintotheearcanal(max. 1 sec.)
andimmediatelypresstheSTARTbutton.
Releasethebuttonandwaitforthebeep
sound.Thisistheindicationthatconfirms
theendofmeasurement.
6. Removethethermometerfromtheearcanal.
Thedisplayshowsthemeasuredtemperature.
NOTE:
To ensure accurate readings, wait at least 30 sec. after 3-5
continuous measurements.
EN
8
Replacetheprobecoveraftereachmeasurement.Todothis,please
followtheinstructioninpoint6«HowtoReloadaNewProbeCover».
• 10shortbeepsandaredLCDbacklightalertthepatientthathe/
shemayhaveatemperatureequaltoorhigherthan37.5°C.
• Foraninfant,itisbesttohavethechildlyingflatwithhis/herhead
sidewayssotheearisfacingupwards.Foranolderchildoradult,
itisbesttostandbehindandslightlytothesideofthepatient.
• Alwaystakethetemperatureinthesameear,sincethetempera-
turereadingsmaybedifferentfromeartoear.
• Waitforafewminutestotaketheeartemperatureaftersleeping.
• Inthefollowingsituationsitisrecommendedthatthreetempera-
turesinthesameearbetakenandthehighestonetakenasthe
reading:
1) Newborninfantsinthefirst100days.
2) Children underthreeyearsofage with a compromisedimmune
systemandforwhomthepresenceorabsenceoffeveriscritical.
3) When the user is learninghowtousethethermometerforthe
firsttimeuntil he/she has familiarized himself/herself with the
instrumentandobtainsconsistentreadings.
4) Ifthemeasurementissurprisinglylow.
8. Changing from Fahrenheit to Celsius and vice-versa
Thethermometercandisplaytemperaturemeasurementsineither
FahrenheitorCelsius.Toswitchthedisplaybetween°Cand°F,simp-
lyturnOFFtheunit,press and holdtheSTARTbuttonfor5seconds
until«---»andtheflashing«°C»or«°F»iconisshownontheLCD.
Switchthemeasurementscalebetween°Cand°Fbypressingthe
STARTbuttonagain.Whenthemeasurementscalehasbeenchosen,
waitfor5secondsandtheunitwillenterthereadyformeasuring
modeautomatically.
9. How to recall 12 readings in Memory Mode
Thisthermometercanrecallthelast12readings.Torecallplease
followsequence.
PressingandreleasingtheSTARTbuttonafterthelast12readings
havebeenrecalledwillresumetheabovesequencefromreading1.
10. Cleaning and Storage
Useanalcoholswaborcottontissue
moistenedwithalcohol(70%Isopropyl)
tocleanthethermometercasingandthe
measuringprobe.Ensurethatnoliquid
enterstheinteriorofthethermometer.
Neveruseabrasivecleaningagents,thin-
nersorbenzeneforcleaningandnever immerse the instrument in
water or other cleaning liquids.Takecarenottoscratchthesur-
faceoftheprobelensandthedisplay.Removethebatteryfromthe
instrumentifitisnotrequiredforextendedperiodsoftimeinorderto
avoiddamagetothethermometerresultingfromaleakingbattery.
9
LCD Display Display
Meaning
Description
RecallMode PresstheSTARTbuttonto
enterRecallModewhen
powerisoff.Thememory
icon«M»flashes.
Reading1
(thelastrea-
ding)
Pressandreleasethe
STARTbuttontorecall
thelastreading.Display1
alonewithmemoryicon.
Reading2
(thesecond
latestreading)
Pressandreleasethe
STARTbuttontorecallthe
secondlatestreading.
Reading12
(thelast
reading)
Pressandreleasethe
STARTbuttonconsecu-
tivelytorecallreadingsin
succession,uptothelast
12readings.
EN
11. Error messages
10
Display / Problem Display
Meaning
Possible cause and
fault remedy
Measured
Temperaturetoo
high
Displays«H»when
measuredtemperature
higherthan100.0°C
or212.0°F.
Measuredtempe-
raturetoolow
Displays«L»when
measuredtemperature
lowerthan0°Cor
32.0°F.
Ambienttempera-
turetoohigh
Displays«H» in
conjunctionwiththe
«»whenambient
temperatureishigher
than40.0°Cor
104.0°F.
Ambienttempera-
turetoolow
Display«L»incon-
junctionwiththe«»
whenambienttempe-
ratureislowerthan
5.0°Cor41.0°F.
Errorfunction
display
Whensystemhas
malfunction.
Blankdisplay Pleasecheckifthe
batteryhasbeen
loadedcorrectly.Also
checkpolarity(<+>
and<->)ofbattery.
Deadbattery
indication
Ifthesteadybattery
iconistheonly
symbolshownonthe
display,thebattery
shouldbereplaced
immediately.
11
12. Replacing the battery
Thisinstrumentissuppliedwithonelithiumbattery,typeCR2032.
ReplacewithanewCR2032batterywhentheflashingbatterysymbol
appearsonthedisplay.Removethebatterycoverbyslidingitinthe
directionshown.Removethebatteryandreplacewithanewone.
13. Guarantee
Subjecttothefollowingconditionsthishigh-qualitymeasuringinstru-
mentiscoveredbya2 year guaranteefromthedateofpurchase.
Warrantyclaimsmustbelodgedwithintheguaranteeperiod.
Thisproductwasmanufacturedwiththeutmostofcareaccording
tointernationalqualitystandards.Shouldyouhavereasonforcom-
plaintsdespitethis,pleasesendtheinstrument,accompaniedbythe
completedGuaranteeCardwithdealer’sstampaswellasoriginal
proofofpurchasedirectlyorthroughyourmedicalsuppliertoyour
closestMicrolifeDistributor.
Damageresultingfromincorrectuseisnotcoveredbytheguarantee.
Batteryandpackagingareexcludedfromtheguarantee.Claims
beyondthis,includingclaimsfordamages,areexcluded.
Nameandadressofresponsibledealer:
Batteriesandelectronicinstrumentsmustbedisposedofin
accordancewiththelocallyapplicableregulations,notwith
domesticwaste.
EN
12
14. Technical Specifications
Type: DigitalInfraredEarThermometerIR1DE1
Measuring Range:0°Cto100.0°C/32.0°Fto212.0°F
Accuracy: Laboratory:
±0.2°C,32.0~42.2°C/±0.4°F,89.6~108.0°F
±1°C,0~31.9°C,42.3~100.0°C/
±2°F,32.0~89.5°F,108.1~212.0°F
Display: LiquidCristalDisplay,withindicatingunit0.1°C/°F
Accoustic: a.TheunitisturnedONandreadyforthe
measurement:1short«bi»sound.
b. Completethemeasurement:1longbeep(1sec.),
ifthereadingislessthan37.5°C/99.5°F,10
short«beep»sounds,ifthereadingisequalto
orgreaterthan37.5°C/99.5°F.
c. Systemerrorormalfunction:3short«bi»sounds.
Memory: a.Auto-Displaythelastmeasuredtemperature
whenswitchedon.
b. 12readingsrecallintheMemoryMode.
Backlight: • ThedisplaywillbelightedGREENfor4sec.,
whentheunitisturnedON.
• ThedisplaylightwillbeGREENfor5seconds,
whenameasurementiscompletedwitha
readinglessthan37.5°C/99.5°F.
• ThedisplaylightwillbeREDfor5seconds,
whenameasurementiscompletedwitha
readingequaltoorhigherthan37.5°C/99.5°F.
Operating temp.: 10°Cto40°C/50.0°Fto104°F;
15-95%relativemaximumhumidity
Storage temp.: -25°Cto+55°C/-13°Fto131°F;
15-95%relativemaximumhumidity
Automatic Approx.1minuteafterlastmeasurement.
Switch-off: Auto-offifSTARTbuttonispressed.
Battery: CR2032battery(X1)-atleast1000measurements
Dimensions: 153mm(L)x31mm(W)x20mm(H)
Weight: 53g(w/battery),50g(w/obattery)
Standards: EN12470-5;ASTME1965;IEC60601-1
IEC60601-1-2(EMC)
ThisdevicecomplieswiththerequirementsoftheMedicalDevice
Directive93/42/EECClassIIa.Technicalalterationsreserved.
15. www.microlife.com
Detaileduserinformationaboutourthermometersandbloodpressure
monitorsaswellasservicescanbefoundatwww.microlife.com.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Microlife IR 1DE1 Navigation Manual

Category
Digital body thermometers
Type
Navigation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages