UPS 1000 VA
Quick Installation Guide
17680
Protect
?
FAQ trust.com/17680/faq
20110308R1 © Trust International B.V.
?
6
1
4
53
a
b
c
2
OXXTRON 1000VA UPS – User’s Manual
2
Package contents (Package contents)
On/Off button
Status LEDs:
Red
Yellow
Green
AC input port
Fuse holder
Output
Loop through cables (2x)
Installation (Installation)
-
T
urn off your compu
t
er.
- Disconnect the AC input cables from your computer and from its monitor.
-
Connect your computer’s AC input cable to the UPS’ AC input port ( ).
-
Use loop through cables ( ) to connect the computer and its monitor to the UPS backup outputs
( ).
-
T
urn on the UPS.
- Charge the UPS for 8 hours.
-
T
he equipment connected to the UPS can be switched on.
Replacing the fuse (Replacing the fuse)
- Make sure the UPS is completely off, (disconnect mains power).
- Use a spare fuse of same rating (250V, 5A)!
-
Open the fuse holder ( ).
- Replace the fuse and close the fuse holder.
OXXTRON 1000VA UPS – User’s Manual
3
Safety & proper usage reminders (Safety & proper usage reminders)
- When connected to mains power, the UPS needs to be On for its battery to charge.
- Do not open or repair this device, and keep it away from liquids.
- If the battery is opened or damaged, the substances released may be flammable and harmful to
skin, eyes.
- Always connect the UPS to an earthed wall socket.
- Do not connect a multiple socket to the UPS.
- The output ports may still be powered, even when the device is turned off.
- Make sure the device is not placed on a heat-sensitive surface and that the UPS has sufficient
ventilation.
Troubleshooting (Troubleshooting)
Indication Reason and Action
Y
ellow LED steady
No beeps
Reason: The battery is charging.
Action: No action required.
Y
ellow and green LEDS steady
No beeps
Reason: The battery is fully charged, and the UPS is functioning
normally.
Action: No action required
Red LED flashing
1 beep every 5 seconds
Reason: The UPS is not powered (power outage)
T
he UPS is powering the connected devices with its battery.
Action: Save your documents and shut down the computer.
Red LED steady
2 beeps every second
Reason: The UPS is not powered (power outage).
he battery will be empty within 2 minutes.
Action: Save your documents and shut down the computer urgently.
Red LED steady
4 beeps every 2 seconds
Reason: The UPS is overloaded.
Action: Disconnect some devices from the UPS output ports.
Red LED steady
Continuous beeping
Reason: The UPS is in short circuit.
Action: Check each of the connected devices to identify the faulty one.
No LEDs
No beeps
Reason: The battery is discharged, or the fuse needs replacing.
Action: Connect the UPS to a power source, or replace the fuse.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Trust Oxxtron Installation guide

Category
Uninterruptible power supplies (UPSs)
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI