1. SPECIFICATIONS
MODEL
GUARD 230V~ GUARD 115V~ GUARD 24V GUARD 12V
Power supply 230 V~ (+6% -10%) 115 V~ (+6% -10%) 24V 12 V
Absorbed power 40 W 15 W 40 W
Steady light NO YES
Flashing light YES NO
Lamp 230V~ 40W Max. E27 115V~ 40W Max. E27 24V 15W Max. E14 12V 15W Max. BA15S
Antenna OPTIONAL
Operating temperature
-20°C +55°C
Degree of protection IP55
Insulation class Class II Class III
2. DESCRIPTION (Fig. 1)
Pos Description
a
Cap
b
Lamp-holder board
c
Cap base
d
Right slide
e
Left slide
f
Flashing lamp support
g
Wire sleeve
h
Antenna support
i
Optional antenna
3. INSTALLATION AND CONNECTIONS
The GUARD ashing lamp was designed for installation in different posi-
tions, according to the installer’s needs (Fig. 2).
Securingtheashinglampinbothhorizontalandupside-down
position(Fig.2ref.d, eandf)isallowedonlyinprotected
places,e.g.inundergroundgarages.Theashinglampcan-
notbesecuredinthesepositionsiftheapplicationislocated
outdoors.
TomaintaintheIP55degreeofprotection,theashinglampmust
absolutely be installed on a at surface. The ashing-lamp
supportmustrestinauniformway.
As shown in Fig. 2, holes are provided on the ashing lamp support, for
securing it in the different positions.
Flashing lamp installation procedure:
Select the installation position for the ashing lamp, respecting the
following points:
the ashing lamp must always be installed vertically, with the exception
of covered places, where it may be installed horizontally (Fig. 2).
the ashing lamp is a signalling device and, as such, it signals leaf
movement. It must therefore be installed in a position where it can
be seen from all directions, and must not be unsighted by trees,
signs or any other object.
the ashing lamp must be positioned close to the automated sy-
stem.
Ifpointscandbcannotbeadheredtosimultaneously,weadvise
youtoinstalltwoashinglamps,oneinapositionvisiblefrom
alldirectionsandtheotherclosetotheautomatedsystem.
If necessary, free, on the ashing lamp support, the securing holes for
the selected position.
Secure the support in the desired position using expansion plugs size
Ø5 ( Fig. 3).
Fig. 4 shows the cable routing zones.
We advise you to separate the power cable from the antenna cable,
to avoid bringing electrical noise into the control unit. Positions “A”
and “B” refer to two pre-drilled holes on the support, which, if used,
must be opened.
Free a pre-drilled hole on the cap base and the wire sleeve holes too.
The wire sleeve is designed for routing wires only - an entire cable
cannot be routed through it.
Position the wire sleeve in the freed hole.
Fit the cable in the ashing lamp support, according to the selected
route, and then in the cap support as shown in Fig. 5.
Connect the cable to the terminals of the lamp-holder board, Fig.6.
Secure the lamp-holder to the cap base, exerting light pressure on the
board until is anchored (Fig. 6).
Secure the cap base to the ashing lamp support, using the two supplied
screws (Fig. 7).
1.
a–
b–
c–
2.
3.
4.
5.
6.
7.
8.
9.
10.
Position the antenna support as in Fig. 8.
Cap installation procedure:
the cap can be oriented with the “GENIUS” logo in four different po-
sitions, every 90° (Fig. 9).
t the cap with logo in the desired position, and gently turn it anti-
clockwise until it is inserted into its seat.
turn clockwise until the cap is fully locked.
Alockingtabisprovidedonthecapbase(Fig.10ref.a)-itmust
snapintotherecessonthecap(Fig.10ref.b).
Fit the two front slides as shown in Fig. 11.
4. ANTENNA INSTALLATION (optional)
The GUARD ashing lamp is designed for installation of an antenna. Ob-
serve the following antenna installation procedure:
Open the pre-drilled Ø 9 hole on the antenna support (Fig. 12 ref. a).
Fit the antenna with the supplied accessories as shown in Fig. 12.
Insert the cable in the ashing lamp (Fig. 12 rif. b).
Position the entire assembly on the ashing lamp support as in Fig.
13.
Keep the power cables separate from the antenna cable, using
separate sheaths for the cable route from the ashing lamp to the
control unit.
Theantennasupportwasdesignedforttingaheadofthecap,
whichactsasananti-extractiondevice.
5. MAINTENANCE
The ashing lamp does not require scheduled maintenance.
Bulb replacement procedure:
Unscrew the locking system with a screwdriver as shown in Fig. 14,
while turning the cap anti-clockwise.
Remove the cap and replace the bulb.
Forthecorrecttypeofbulb,consultthe“specications”table
accordingtotheinstalledashinglampmodel.
Re-t the cap as described in paragraph 3 in point 12.
CE DECLARATION OF CONFORMITY
Manufacturer: GENIUS S.p.A.
Address: Via Padre Elzi, 32 - 24050 - Grassobbio- Bergamo - ITALY
Declares that: The ashing lamp mod. GUARD
conforms to the essential safety requirements of the following EEC di-
rectives:
2006/95/EC Low Voltage directive.
2004/108/EC Electromagnetic Compatibility directive.
Additional information:
This product underwent a test in a typical uniform conguration (all products
manufactured by GENIUS S.p.A.).
Grassobbio, December 30, 2009
Managing Director
D. Gianantoni
11.
12.
a–
b–
c–
13.
1.
2.
3.
4.
1.
2.
3.
•
•