Installation and Maintenance Instructions
Solenoid for potentially explosive atmospheres Type of protection “n” (WPZN/WSZN-M12-I)
GENERAL
This installation and maintenance
instruction sheet of the solenoid is a
general supplement to the particular
I&M sheet for the valve. The identi-
cation is made by prex ZN to the cat-
alogue number. Always use both I&M
sheets for installing and maintaining
the solenoid valve.
DESCRIPTION
The solenoid valves are designed
in accordance with Annex II of the
European Directive 94/9/EC and
CENELEC standards EN 13463-1,
EN 50281-1-1, EN-IEC-60079-0 and
EN-IEC-60079-15. Classification II
3G/D EExnAII IP67.
INSTALLATION
ASCO Numatics components are
intended to be used only within the
technical characteristics as specied
on the nameplate. Changes to the
equipment are only allowed after
consulting the manufacturer or its rep-
resentative. These solenoid valves are
intended for installation in potentially
explosive atmospheres, Group II gas-
es, vapors, mists or dusts (Group G/D,
category 3). The surface temperature
classication depends on wattage and
ambient temperature and is stated
on the nameplate. Depending on the
ambient temperature/wattage, a heat
resistant cable, suitable for tempera-
ture as indicated on the nameplate,
must be used.
ELECTRICAL INSTALLATION
Wiring must comply with local and
national regulations of explosion
proof equipment. To make connection
to the coil terminals, remove solenoid
cover. Strip the outer insulation of the
cable over approx. 30 mm and the
insulation from the leads over 8 mm.
Insert wires through the cable gland
or conduit hub and connect wires
to the terminals of the coil. Connect
cable ground wire to the internal
ground terminal. Keep some slack
in the leads between cable entry and
coil to avoid excessive strain on the
leads. Assemble the cable gland and
tighten the elastomer compression
seal so that it ts tightly around the
cable. When the retaining clip/nut is
unscrewed, the solenoid can be rotat-
ed 360° to select the most favorable
position for the cable entry. Tighten
retaining clip/nut securely and close
the enclosure. The solenoid housing
is provided with an external connec-
tion facility for an earthing or bonding
conductor.
NOTE: THE STANDARD CABLE
GLAND ACCEPTS CABLES WITH
OVERALL O.D. from 7 to 12 mm.
CAUTION
Electrical load must be within the
range stated on the nameplate. Fail-
ure to stay within the electrical range
of the coil rating results in damage to
or premature failure of the coil. It will
also invalidate the approval.
SERVICE
To prevent the possibility of personal
or property damage, do not touch the
solenoid. It can become hot under
normal operation conditions. If the
solenoid valve is easily accessible,
the installer must provide protection
preventing accidental contact.
MAINTENANCE
Maintenance depends on service
conditions. Periodic cleaning is rec-
ommended, the timing of which will
depend on the media and service con-
ditions. During servicing, components
should be examined for excessive
wear. A complete set of internal parts
is available as a spare parts kit. If a
problem occurs during installation/
maintenance or in case of doubt please
contact ASCO Numatics or authorized
representative. CAUTION: Before
servicing the solenoid valve, turn off
electrical power, depressurize valve
and vent uid to a safe area. Solenoid
must be fully reassembled as the
housing and internal parts complete
the magnetic circuit. In case of any
replacement of parts by the user, the
traceability of the nal product can not
be guaranteed by ASCO Numatics.
Wrong assembly will invalidate the
approval.
DECLARATION
For additional information visit our inter-
net site: www.asconumatics.eu
IM1047-33A-X / pg. 1
123620-224X
1. Cover assembly
2. Retaining clip
3. Washer
4. Washer, ux
5. Sleeve
6. Yoke
7. Coil
8. Housing assembly
9. Gasket, housing assembly
10. Sol. base sub-assembly
11. Spacer, push type
1. Montage du couvercle
2. Clip de maintien
3. Rondelle élastique
4. Rondelle, ux
5. Gaine isolante
6. Culasse
7. Bobine
8. Montage du boîtier
9. Joint d’étanchétié, montage
du boîtier
10. Sous-ensemble de la base
du sol.
11. Bague d’espacement, type
poussoir
1. Deckelbaugruppe
2. Klammerhalterung
3. Scheibe
4. Scheibe, Fluß-
5. Hülse
6. Joch
7. Magnetspule
8. Gehäuse
9. Dichtung, Gehäusebau-
gruppe
10. Haltemutter
11. Distanzstück, Druckaus-
führung
1. Gruppo custodia
2. Clip di ssaggio
3. Rondella
4. Rondella, usso
5. Manicotto
6. Giogo
7. Bobina
8. Gruppo sede
9. Guarnizione, gruppo involucro
10. Gruppo cannotto solenoide
11. Distanziatore, tipo a
pressione
1. Deksel
2. Bevestigingsclip
3. Ring
4. Kortsluitring
5. Huls
6. Juk
7. Spoel
8. Spoelhuis
9. Afdichting, spoelhuis
10. Kopstuk/deksel-combinatie
11. Opvulring, duwmagneetkop
TORQUE CHART
A 1,5 ± 0,2 12 ± 2
B 0,5 ± 0,1 4 ± 1
C 2 ± 0,2 17 ± 2
D 20 ± 3 175 ± 25
ITEMS NEWTON.METRES INCH.POUNDS
GB
FR
DE
IT
NL
Supplied in spare part kit
Livrées en pochette de rechange
Enthalten im Ersatzteilsatz
Disponibile nel Kit parti di ricambio
Geleverd in vervangingsset
2/2 PULL TYPE
TYPE EXTRACTION 2/2
2/2-ZUGAUSFÜHRUNG
TIPO AD ESTRAZIONE 2/2
2/2 TREK
2/2 PULL TYPE
TYPE EXTRACTION 2/2
2/2-ZUGAUSFÜHRUNG
TIPO AD ESTRAZIONE 2/2
2/2 TREK
2/2 PUSH TYPE
TYPE POUSSOIR 2/2
2/2-DRUCKAUSFÜHRUNG
TIPO A PRESSIONE 2/2
2/2 DUW
PREFIX ‘T’, 1/2” NPT
PREFIXE ‘T’, 1/2” NPT
VORSATZ ‘T’, 1/2” NPT
PREFISSO ‘T’, 1/2” NPT
VOORVOEGSEL ‘T’, 1/2” NPT
PREFIX ‘ET’, M20 x 1,5
PREFIXE ‘ET’, M20 x 1,5
VORSATZ ‘ET’, M20 x 1,5
PREFISSO ‘ET’, M20 x 1,5
VOORVOEGSEL ‘ET’, M20 x 1,5
2/2 PUSH TYPE
TYPE POUSSOIR 2/2
2/2-DRUCKAUSFÜHRUNG
TIPO A PRESSIONE 2/2
2/2 DUW
SERIES
WPZN/WSZN - M12-I
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Asco Series WPZN/WSZN-M12-I Solenoid Explosive Atmosphere Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI