SUNCO T8 Installation guide

Type
Installation guide

SUNCO T8 LED tube is a direct replacement for fluorescent lamps. It's designed for use with electronic ballasts and operates on 120-277 volts. The tube features a plug-and-play design for easy installation and is suitable for damp locations. It provides bright, energy-efficient lighting while lasting up to 50,000 hours, making it an ideal choice for commercial and industrial applications.

SUNCO T8 LED tube is a direct replacement for fluorescent lamps. It's designed for use with electronic ballasts and operates on 120-277 volts. The tube features a plug-and-play design for easy installation and is suitable for damp locations. It provides bright, energy-efficient lighting while lasting up to 50,000 hours, making it an ideal choice for commercial and industrial applications.

LED T8 PLUG & GO™
INSTALL INSTRUCTIONS • ELECTRONIC BALLAST REQUIRED (UL TYPE A)
DO NOT INSTALL THIS LAMP IN A PRE - HEAT LUMINAIRE.
THIS LAMP ONLY OPERATES ON ELECTRONIC BALLASTS. IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM
LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIAN.
CAUTION RISK OF FIRE - IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER,
REMOVE LAMP FROM LUMINAIRE AND CONTACT MANUFACTURER.
SAFETY INFORMATION:
• Check the lamp before installation, if there is any damage caused during transportation, do not install.
• Maintenance should be carried out by technical personnel only.
• Do not stare at the light source with bare eyes for a long time, or beam into another persons eyes.
• Do not place any objects on the lamp.
• Keep the lamp away from flame or high temperature objects.
• Risk of electrical shock. Only replace with same type of LED tube.
• If the glass lamp tube is broken, the lamp must be disposed of immediately.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Please completely comply with these instructions and notes to ensure that the product is operated in a safe condition.
WARNING: Risk of shock. Disconnect power before installation.
WARNING: RISK OF FIRE. USE ONLY IN PLACE OF FLUORESCENT LAMPS SPECIFIED ON LABEL RISK OF ELECTRIC SHOCK.
LED T8 lamp for use only with products described and installed in accordance with product specifications. LED T8 lamp to be operated with fluorescent
electronic ballast.
SUITABLE FOR DAMP LOCATIONS.
NOT FOR USE WITH EMERGENCY LIGHTING.
!WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
MAINTENANCE NOTES
1. Disconnect lamp from power supply before any maintenance.
2. Clean luminaire with dry cloth.
3. Do not clean the lamp with corrosive chemicals.
1. Make sure power is OFF.
2. Remove lens or diuser
(if applicable).
4. Bring LED lamp to luminaire
and insert lamp pins into
luminaire lamp holders.
5. Rotate LED lamp until lamp
locks in place. Ensure that the
LED lamp front points away from
the back of the luminaire.
3. Remove existing fluorescent
lamps from the luminaire.
6. Place lens or diuser back in place (if applicable).
7. Power On.
Note: Install LED T8 replacement lamp one for each fluorescent lamp removed.
LED T8 PLUG & GO™
INSTALL INSTRUCTIONS • ELECTRONIC BALLAST REQUIRED (UL TYPE A)
INSTANT START BALLAST WIRING DIAGRAMS • CORRECT
• TWO LAMP BALLAST WIRING • CORRECT
• THREE LAMP BALLAST WIRING • CORRECT
• FOUR LAMP BALLAST WIRING • CORRECT
BALLAST
LAMP
WHITE
BLACK
LINE
BLUE
BLUE
RED
CAP
BALLAST
LAMP
WHITE
BLACK
LINE
BLUE
BLUE
RED
LAMP
BALLAST
LAMP
WHITE
BLACK
LINE
BLUE
BLUE
RED
CAP
BLUE
LAMP
BALLAST
LAMP
WHITE
BLACK
LINE
BLUE
BLUE
RED
BLUE
LAMP
LAMP
RED
BLUE
BLUE
RED
WHITE
BLACK
YELLOW
YELLOW
BALLAST
LAMP
LINE
CAP
LAMP
LAMP
RED
BLUE
BLUE
RED
WHITE
BLACK
YELLOW
YELLOW BALLAST
LAMP
LINE
LAMP
LAMP
LAMP
LED T8 PLUG & GO™
INSTALL INSTRUCTIONS • ELECTRONIC BALLAST REQUIRED (UL TYPE A)
INSTANT START BALLAST WIRING DIAGRAMS • INCORRECT
• TWO LAMP BALLAST WIRING • INCORRECT
• THREE LAMP BALLAST WIRING • INCORRECT
• FOUR LAMP BALLAST WIRING • INCORRECT
BLUE
BLUE
RED
WHITE
BLACK BALLAST
LAMP
LINE
RED
BLUE
BLUE
WHITE
BLACK BALLAST
LINE
LAMP
BLUE
WHITE
BLACK BALLAST
LINE
LAMP
RED
BLUE
BLUE
BLUE
CAP
CAP
WHITE
BLACK BALLAST
LINE
LAMP
RED
BLUE
BLUE
BLUE
CAP
WHITE
BLACK BALLAST
LINE
LAMP
RED
BLUE
BLUE
BLUE
LAMP
WHITE
BLACK BALLAST
LINE
LAMP
RED
BLUE
BLUE
YELLOW
CAP
RED
YELLOW
WHITE
BLACK BALLAST
LINE
LAMP
RED
BLUE
BLUE
YELLOW
CAP
RED
YELLOW
CAP
CAP
CAP
WHITE
BLACK BALLAST
LINE
RED
BLUE
BLUE
YELLOW RED
YELLOW
LAMP
LAMP
WHITE
BLACK BALLAST
LINE
RED
BLUE
BLUE
YELLOW RED
YELLOW
LAMP
LAMP
WHITE
BLACK BALLAST
LINE
LAMP
RED
BLUE
BLUE
YELLOW
CAP
RED
YELLOW
CAP
CAP
WHITE
BLACK BALLAST
LINE
RED
BLUE
BLUE
YELLOW RED
YELLOW
LAMP
WHITE
BLACK BALLAST
LINE
RED
BLUE
BLUE
YELLOW RED
YELLOW
LAMP
LAMP
LAMP
  • Page 1 1
  • Page 2 2
  • Page 3 3

SUNCO T8 Installation guide

Type
Installation guide

SUNCO T8 LED tube is a direct replacement for fluorescent lamps. It's designed for use with electronic ballasts and operates on 120-277 volts. The tube features a plug-and-play design for easy installation and is suitable for damp locations. It provides bright, energy-efficient lighting while lasting up to 50,000 hours, making it an ideal choice for commercial and industrial applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI