Tools and Materials
Before You Begin
IMPORTANT! To ensure a successful installation, install the bath on a level finished floor.
IMPORTANT! This product requires a K-7219 drain for proper installation.
Observe all local plumbing and building codes.
Unpack and inspect the bath for damage. Return the bath to the carton until installation.
Make sure all plumbing connections around the bath are easily accessible for future maintenance.
We strongly recommend that this installation be performed by a professional plumber or contractor.
Provide access for making the final drain connection from below.
A minimum of two people are needed to perform this installation.
This bath is designed for a freestanding installation only.
Select fasteners and a drilling method based on the type of floor the bath will be attached to.
This bath conforms to CSA B45.5/IAPMO Z124. All dimensions are nominal.
1. Prepare the Site
NOTICE: Provide adequate floor support.
NOTICE: Measure your product for site preparation. Note the model number located on the back of the
bath, then visit the product page at www.kohler.com for more information.
Ensure the subfloor is level.
Determine the location of the bath. Provide a minimum clearance of 24 (610 mm) around the
perimeter of the bath. Additional space is recommended to ease installation.
Use the cut-out template provided with the bath to properly mark the water supply and drain
locations in relation to the chosen location of the bath.
Cut the marked water supply and drain locations on the subfloor with a saw and hole saw.
Install the finished flooring material prior to installing the bath.
Ensure the finished floor is level before proceeding with the bath installation.
Sealant
Plus:
Conventional tools and materials
• Drop cloth
• Fasteners (as necessary)
• Rags
• Saw horses
• Hole saw
1207307-2-B 2 Kohler Co.
2. Prepare the Location For the Drain
IMPORTANT! For installation on a concrete floor, clearance for the drain assembly must be provided.
Refer to the template provided with the bath.
Provide access for making the final drain connection from below.
Verify adequate drain clearance so the bath will install properly.
1-1/2"
(38 mm)
Finished Floor
Gasket
Frame
Bath
Kohler Co. 3 1207307-2-B
3. Prepare the Bath
IMPORTANT! Do not remove the bath feet or levelers from the bath.
Position the bath upside down on saw horses.
Remove and retain the screw from each corner of the bath shell.
Lift the shroud off the bath shell and set it aside.
IMPORTANT! For installation on a concrete floor, clearance for the drain assembly must be provided.
Refer to the template provided with the bath.
Install the bath drain to the bath according to the instructions included with the drain.
Remove the tape from the four foot clips. Make sure the locking plates are in the locked position
and are oriented toward the outside of the bath as illustrated.
Screw
x4
Shroud
Saw Horse
Bath
Locked
Position
Foot Clip
Tape
1207307-2-B 4 Kohler Co.
4. Position Two Foot Clips (Without Shroud)
Turn the bath shell over and set it in position on the finished floor. Make sure the drain lines up
with the drain pipe and there is no drain interference with the floor.
Position each locking plate with the hole to the outside of the bath.
Trace around the edges of the two foot clips located at the front of the bath, opposite the overflow.
Lift the bath and turn it upside down on saw horses.
Finished Floor
Drain Pipe
Overflow
Bath
Front
Locking Plate
with Hole
Drain
Kohler Co. 5 1207307-2-B
5. Secure Two Foot Clips (Without Shroud)
Pull out the locking plates on the two foot clips that were traced on the floor and remove the foot
clips.
Position these foot clips on the traced lines and mark the four screw holes.
IMPORTANT! Make sure the foot clips will be flush with the finished floor after installation. If you use
anchors that protrude above the finished floor, recess the finished floor material around the holes or recess
the anchors so the foot clips are flat against the finished floor.
Carefully drill the four screw hole locations in the finished floor, and secure the foot clips to the
floor using fasteners suitable for the floor material.
Unlocked
Position
Finished Floor
Subfloor
Foot Clip
1207307-2-B 6 Kohler Co.
6. Secure Remaining Foot Clips (Without Shroud)
Reposition the bath so the two posts located on the bath frame fit into the installed foot clips. Do
not move the locking plates into the locked position on the two foot clips mounted to the floor.
Make sure the locking plate screw hole faces the outside of the bath on each of the two remaining
foot clips.
Trace the outline of the two remaining foot clips.
Lift the bath and set it aside.
Repeat the previous steps to remove, mark, drill, and secure the two remaining foot clips.
Unlocked
Position
Bath
Front
Kohler Co. 7 1207307-2-B
7. Secure the Bath
Turn the bath shell upside down on the saw horses.
Make sure all the drain connections are secure.
Position the shroud on the bath so the edges of the shroud rest inside the bath shell.
Secure the shroud to the bath with a screw at each corner. Do not overtighten.
Make sure the foot clips are not in the locked position.
Carefully lift the bath into position so the posts on the bath frame fit into the four foot clips, and the
drain tailpiece fits into the drain pipe.
Check for solid fit (no rocking) and a 24-1/8 (613 mm) rim corner height to the finished floor.
Lift and move the bath if needed, and adjust the four posts as needed to ensure a distance of
24-1/8 (613 mm) from the finished floor to the top of each bath rim corner. Adjust the bath levelers
as needed. Make sure the bath levelers and bath feet are tight.
Press down on the bath corners with your hand to make sure the bath does not move up and down,
or side to side. If the bath moves check that all four posts are inside the foot clips, and check that
the floor is level.
Use a flat-bladed screwdriver to push in the four locking plates to lock the bath feet in place.
8. Complete the Installation
Secure the drain tailpiece to the drain pipe.
Install the bath faucet according to the instructions included with the faucet.
Run water into the bath and check the drain connections for leakage.
24-1/8"
(613 mm)
x4
x4
x4
x2
Post
Bath
Leveler
1207307-2-B 8 Kohler Co.
Care and Cleaning
For best results, keep the following in mind when caring for your KOHLER product:
Always test your cleaning solution on an inconspicuous area before applying to the entire surface.
Wipe surfaces clean and rinse completely with water immediately after applying cleaner. Rinse and
dry any overspray that lands on nearby surfaces.
Do not allow cleaners to soak on surfaces.
Use a soft, dampened sponge or cloth. Never use an abrasive material such as a brush or scouring
pad to clean surfaces.
For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care &
Cleaning information, call 1-800-456-4537.
Warranty
ONE-YEAR LIMITED WARRANTY
KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year
from date of installation.
Kohler Co. will, at its election, repair, replace or make appropriate adjustment where Kohler Co. inspection
discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not
responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home
Center or E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI
53044, USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and
001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from
within Canada, or www.mx.kohler.com in Mexico.
IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS
WARRANTY. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how
long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages,
so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You
may also have other rights which vary from state/province to state/province.
This is Kohler Co.’s exclusive written warranty.
Kohler Co. 9 1207307-2-B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Kohler K-11344-47 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI