Omega Engineering OS-PP User manual

Type
User manual

This manual is also suitable for

Omegaette Pocket PP™
OS-PP
Non-Contact Infrared Thermometer
INSTRUCTION
SHEET
M3846/0902
3. Emission factor: The physical quantity known as the emission factor
describes to what extent the infrared heat radiation that is emitted from an
object is determined by Its own temperature. Accordingly, a value of 1 tells
us that the infrared heat radiation from the object is based only on its own
temperature. A value of less than 1 means that the radiation emitted from
the object is not only deter mined by its own temperature but also by
reflections from neighboring bodies or due to the transmission, i.e. the
diathermancy, of the object. The emission factor thus has an effect on the
result of the measurement. The Infra-Red Thermometer works with an
emission factor of 0.95, i.e. the measuring unit assumes that the object
being monitored has a factor of 0.95. If this is not the case, there will be
inaccuracies in the measurement (see Section 2.5 “Measuring
inaccuracies").
2. Operation
2.1. Display and operator controls
All the functions of the measuring unit are
controlled and monitored using the
operating button 7 and the back-lit display.
1 Temperature display - currently
measured value
2 Hold indicator
3 Temperature display - minimum value
4 Temperature display - maximum value
5 Battery symbol - (low battery indicator)
6 Temperature units - °C or °F
7 Operating button
8 Lens
2.2. Making a measurement
The unit is switched on by pressing the operating button. The display will
show horizontal bars until the first measurement is available. The current
temperature will then be displayed in the upper main part of the display.
The button must be pressed for the duration of the measurement, where by
the display of the measured value will be continuously updated. The lens
must be focussed on the object while the measurement is being made. At
the same time, the object being measured must be larger than the area
monitored by the Infra-Red Thermometer (see 2.5. “Measuring
inaccuracies”). The measurement will be finished by releasing the button.
The “Hold” indication signals that measuring has stopped. The last
measurement will be shown in the upper main part of the display. The
display back light will go out 8 seconds after the button has been released.
The unit will switch itself off automatically 30 seconds after the last
measurement. It will be necessary to replace the batteries as soon as the
battery symbol appears in the display.
2.3. Minimum and maximum temperature indication
The minimum and maximum value memories are cleared at the start of a
measurement by pressing the operating button. The temperature will be
measured and the minimum and maximum temperatures will be determined
for as long as the button is pressed. The minimum temperature is shown in
the lower left hand part of the display and the maximum temperature can be
seen in the lower right hand part. These values each apply to the current
measuring cycle and are cleared as soon as the button is pressed again.
2.4. Changeover °C/°F
The units for the temperature display can be switched between degrees
Centigrade (°C) and degrees Fahrenheit (°F) by pressing the button briefly
twice (double click).
2.5. Back-light
The LCD back-light is constantly switched ON when the Operating button is
pressed. When releasing the Operating button, the back-light will be ON for
approximately 8 seconds before automatically switching OFF.
1. General
1.1. Equipment supplied
• Infra-Red Thermometer base unit
• 4 button cells (already fitted in unit)
1.2. Additional note for newly purchased thermometer
The newly purchased thermometer comes with 4 x LR44 alkaline cells already
inserted inside the battery compartment. For the first time using the
thermometer, gently remove the insulated piece by slowly pulling it out from the
battery compartment.
Test the thermometer by pressing the operating button, the LCD display and
back light will light up briefly. If it is not the case, remove the cells. Wait for 30
seconds, and reinsert the cells again. Make sure the cells are at the positive (+)
pole up into the battery compartment.
Your thermometer is now operational!
1.3. Description of measuring principle
When making a temperature measurement, the surface radiation of the object to
be measured is evaluated using the principle of radiation thermometry. This is a
purely passive process, i.e. no radiation is transmitted, but instead, use is only
made of the natural electromagnetic radiation energy (heat radiation) that every
body above a temperature of absolute zero (-273°C) has. The temperature can
be determined very accurately from this radiation energy if the emission factor of
the object being measured is known.
1.4. Technical information
1.4.1.Technical data
The important technical data are summarized in the adjacent table.
1.4.2.Notes on technical data
1. Accuracy: The larger of the two values given is applicable in each case.
2. Distance to measuring spot size: The parameter D:S characterizes the size of
the measuring spot in proportion to the distance between the object to be
measured and the Infra-Red Thermometer. For example, with a ratio of 6:1 and a
distance of 60 cm, the monitoring area will have a diameter of 10 cm.
Range -20°C to 300°C
Resolution 0.1°C
Accuracy ±2% or ±2°C
Unit °C or °F
Distance to measuring spot size D:S 6:1
Ambient temperature range 0°C to 40°C
Emission factor 0.95
Power supply 4 x LR44 button cells
Baftery life approx. 2000 measurements (depending on the usage)
Dimensions (L x W x H) 56 x 23 x 102 mm
Contents
1. General
1.1. Equipment supplied
1.2. Additional note for newly
purchased thermometer
1.3 Description of measuring
principle
1.4 Technical information
1.4.1 Technical data
1.4.2.Notes on technical data
2. Operation
2.1. Display and operator controls
2.2. Making a measurement
2.3. Minimum and maximum
temperature indication
2.4. Changeover °C/°F
2.5. Back-light
2.6. Measurement inaccuracies
2.7. Fault finding
3. Maintenance
3.1. Changing the batteries
3.2. Cleaning
4. Fastening the Infra-Red
Thermometer
2.6. Measurement inaccuracies
The following points should be observed in order to avoid measurement errors:
1. It must be ensured that the object to be measured completely fills the Infra-
Red Thermometer monitoring area. Errors can occur when measuring small
objects, as the non-contact thermometer also monitors the temperature of the
surroundings as well as the object to be measured. The temperature of the
whole of the monitoring area is determined.
2. The principle of measurement requires the ambient temperature to be
determined. This takes place at 1-minute intervals or each time the unit is
switched on. Changes in the ambient temperature, which can occur when the
user holds the unit in his hand, are not monitored within this time period and
therefore neither of them are taken into account when determining the
indicated temperature. A gradual warming of the unit (the lens) between
ambient temperature measurements can, for example, lead to the indicated
temperature slowly falling.
3. If the emission factor for the object does not correspond to the preset value of
0.95, the temperature will not be calculated correctly. Most surfaces have an
emission factor in the range of 0.8 to 0.99. In general, the darker and more
matt the surface is, the larger its emission factor. If the factor is greater than
0.95, the temperature indicated will be greater than the actual temperature of
the object being measured. If the factor is less than 0.95, the temperature
indicated will be less than the surface temperature.
Polished metals have a very low emission factor and are therefore not
suitable for measuring with a non-contact thermometer. On the other hand,
affixing adhesive tape to or painting the surface will increase the emission
factor and reduce the inaccuracy of the measurement.
4. It is not possible to take measurements through transparent materials (glass,
plexiglass etc.).
5. It is not possible to measure air temperatures.
6. Measurement errors can occur due to air contaminated with dust, steam,
smoke, etc.
2.7. Fault finding
Display shows -.-
The operating button has not been pressed for long enough. This must be
pressed for at least the duration of one measurement, i.e. for at least 1.5
seconds.
Display shows Err.1
The ambient temperature is outside the permitted range.
Display shows 1.
The measured value is outside the permitted range.
Battery symbol illuminates.
The batteries are flat. See 3.1 Changing the batteries.
3. Maintenance
3.1. Changing the batteries
If the battery symbol appears in the display, the batteries must be changed. The
four button cells are accessible after opening the battery compartment at the
rear of the unit. The used batteries must be removed from the battery holders
and replaced by new button cells of the same type. Only LR44 type batteries
may be used. Care must be taken to ensure that the polarity is correct when
inserting. The plus terminal of all four batteries should point upwards. The
batteries must be checked to see that they are properly seated before closing
the battery compartment.
Note: Used batteries should not be disposed of in the household
waste. Old batteries and batteries that no longer work can be
handed in to the local collection point free of charge.
3.2. Cleaning
Clean the unit using only a dry cloth. If the unit is very dirty, the cloth may be
slightly dampened. Do not use cleaners containing solvents. Make sure that no
moisture enters the interior of the unit.
When cleaning the lens, loose particles must be removed using
compressed air. Any remaining dirt can then be removed with a soft
brush or with a cotton-wool bud moistened with water. CAUTION!
Do not use cleaners containing solvents.
4. Fastening the lnfra-Red Thermometer
The carry necklace is supplied with the thermometer.
To fasten, simply insert the clip of the necklace into the buckle end
of the thermometer until it clicks into place.
To unfasten, simply press both sides of the clip and pull until it can
be removed from the buckle.
Servicing North America:
USA: One Omega Drive, Box 4047
ISO 9001 Certified Stamford CT 06907-0047
Tel: (203) 359-1660 FAX: (203) 359-7700
Canada: 976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928 FAX: (514) 856-6886
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: En Espan˜ol: (001) 203-359-7803
FAX: (001) 203-359-7807 [email protected]
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
Czech Republic: Rudé armády 1868, 733 01 Karviná 8
Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342 e-mail: [email protected]
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27
Toll Free in France: 0800 466 342
Germany/Austria:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel:+ 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom
Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
OMEGAnet
®
On-Line Service Internet e-mail
www.omega.com [email protected]
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its
products to the European New Approach Directives. OMEGA will add the CE
mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but
OMEGA Engineering, Inc. accepts no liability for any errors it contains, and
reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be
used for, patient-connected applications.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials
and workmanship for a period of 13 months from date of purchase. OMEGAs
WARRANTY adds an additional one (1) month grace period to the normal one
(1) year product warranty to cover handling and shipping time. This ensures
that OMEGAs customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGAs Customer Service Department will issue an Authorized Return (AR)
number immediately upon phone or written request. Upon examination by
OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGAs WARRANTY does not apply to defects resulting from any
action of the purchaser, including but not limited to mishandling, improper inter-
facing, operation outside of design limits, improper repair, or unauthorized mod-
ification. This WARRANTY is VOID if the unit shows evidence of having been
tampered with or shows evidence of having been damaged as a result of exces-
sive corrosion; or current, heat, moisture or vibration; improper specification;
misapplication; misuse or other operating conditions outside of OMEGAs con-
trol. Components which wear are not warranted, including but not limited to con-
tact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However, OMEGA neither assumes responsibility for any omissions or errors
nor assumes liability for any damages that result from the use of its products
in accordance with information provided by OMEGA, either verbal or written.
OMEGA warrants only that the parts manufactured by it will be as specified
and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRE-
SENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT
THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WAR-
RANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of pur-
chaser set forth herein are exclusive, and the total liability of OMEGA with
respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase
price of the component upon which liability is based. In no event shall
OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it
be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any
nuclear installation or activity; or (2) in medical applications or used on humans.
Should any Product(s) be used in or with any nuclear installation or activity,
medical application, used on humans, or misused in any way, OMEGA assumes
no responsibility as set forth in our basic WARRANTY / DISCLAIMER language,
and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless
from any liability or damage whatsoever arising out of the use of the Product(s) in
such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,
PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM
OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on
the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper
packaging to prevent breakage in transit.
FOR W
ARRANTY RETURNS, please
have the following information
available BEFORE contacting OMEGA:
1. Purchase Order number under
which the product was
PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair
charges. Have the following information
available BEFORE contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2. Model and serial number of the
product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGAs policy is to make running changes, not model changes, whenever an
improvement is possible. This affords our customers the latest in technology
and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This docu-
ment may not be copied, photocopied, reproduced, translated, or reduced to
any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at www.omega.com
TEMPERATURE
Thermocouple, RTD & Thermistor Probes,
Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M03846/0902
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Omega Engineering OS-PP User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI