BUNN
®
practices continuous product research and improvement. We reserve the right to change specifications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
All dimensions shown in centimeters. Bunn-O-Matic Corporation owns all copyrights relating to materials in this publication. Please contact BUNN to request permission to reproduce any portion of this publication.
Dimensions & Specifications
Bunn-O-Matic
®
Corporation - 1400 Stevenson Drive Springfield, Illinois 62703 • USA • +1-217-529-6601 • Fax +1-217-529-2827 • www.bunn.com
Model Product # Volts Amps Tank Heater Total Brewing Shipping Cord Agency
Watts Watts Capacity Weight Attached
CWA-TC 23001.0067 230 9.1 1850 2100 5.2 gal./hr. 28 lbs. Yes
(19.7 L./hr.) (12.7 kg) UK Plug
CWTFA–TC 12950.0362 230 9 1850 2100 5.2 gal./hr. 31 lbs. No
Power cord 27728.0001 (19.7 L/hr.) (14.1 kg)
CWTFB-TC 12950.0361 100 13 1250 1300 3.5 gal./hr. 28 lbs. Yes
(13.3 L/hr.) (12.7 kg)
CWTFA-TC 12950.0415 220 8.6 1850 1900 5.2 gal./hr. 31 lbs. No
Power cord 27728.0001 (19.7 L/hr.) (14.1 kg)
CWTFA-TC 12950.0416 230 9 2022 2070 5.7 gal./hr. 31 lbs. Yes
(21.6 L/hr.) (14.1 kg) UK Plug
Thermal carafe sold separately.
Brewing capacity: based on incoming water temp of 60˚F/15˚C (140˚C/60˚C rise) per 1.9 litre brew time of 4 minutes.
Electrical: 230V model requires 2-wires plus ground service rated 220-240V, single phase, 50/60 Hz.
100V model requires 2-wires plus ground service, single phase, 50 Hz.
220V model requires 2-wires plus ground service rated 220-240V, single phase, 60 Hz.
Plumbing: 20-90 psi (138-621 kPa). M
achine supplied with
1
⁄
4