MicroMod Modcell 2050R-98400-189 Reference guide

Type
Reference guide
98400-189.fh11.FH11 Fri Jan 14 09:58:49 2005 Page 1
Composite
C M Y CM MY CY CMY K
Reference Card
MODCELL TM 2050R
Indicating Process
Controller
MicroMod Automation, Inc.
75 Town Centre Dr.
Rochester, NY 14623 USA
Tel: (585) 321-9200
Fax: (585) 321-9291
928 Jaymor Road, Suite B-120
Southampton, PA 18966 USA
Tel: (215) 355-4377
Fax: (215) 355-4378
MicroMod Automation S. de R.L.
Mexico
Tel: (55) 57373402
Fax: (55) 57373402
WWW.MICROMODAUTOMATION.COM
Top/Middle Display Bottom Display/Entry
LATCHING, NO LATCH
Entry
NONE, PROC HI, PROC LO,
DEV HI, DEV LO, INP2 HI, INP2 LO,
OUT HI, OUT LO
NO (Trip-point in cooling band),
YES (trip-point in heating band)
XXXX (in eng. units). Range:
PROC HI (-2995 to 3000),
PROC LO (-3000 to 2995),
DEV HI, DEV LO (1 to 30000),
INP2 HI (-2995 to 30000),
INP2 LO (-3000 to 30000),
OUT HI, OUT LO (MA OUTP
output limits)
2 (Lowest Priority),
1 (Highest Priority)
XXXX (0 to 1000 in eng. units)
Same steps as Alarm 1.
Repeat for Alarms 3-4.
P2 RELAY ACTION
ALARM 1 SETUP
ALARM 1 TYPE
AL1 TRIP IN HEAT
ALARM 1 TRIP
ALARM 1 PRIORITY
ALARM 1 HYST
ALARM 2 SETUP
The Company's policy is one of continuous
improvement and the right is reserved to modify
specifications without notice.
© 2004, MicroMod Automation Printed in USA
98400-189 Issue 2
10/2004
TAG NAME XXXXXXXX (X = A thru Z, 0 thru
9, space, and special characters
listed in IB-23C650)
ON/OFF DIFF GAP XXXX (0 to span value)
GAIN HEAT XXX.X (0.1 to 3000.0)
GAIN COOL XXX.X (0.1 to 3000.0)
GAIN XXX.X (0.1 to 3000.0)
RESET ENABLE YES, NO
RESET HEAT XXX.X (0.1 to 120 repeats/min.)
RESET COOL XXX.X (0.1 to 120 repeats/min.)
RESET XXX.X (0.1 to 120 repeats/min.)
FIXED MAN RESET NO, YES
MANUAL RESET XXX.X (0.0 to 100%)
PREACT XXX.X (0.0 to 3000.0 seconds)
REM SETP RATIO XX.XX (0.01 to 300.0)
REM SETP BIAS XXXX (-3000 to 30000)
A/M R-B RATIO XX.XX (0.01 to 300.0)
A/M R-B BIAS XXXX (-3000 to 30000)
POS PROP DEADBAND XX.X (0.0 to 50.0%)
POS PROP PREACT XX.X (0.0 to 50.0%)
CYCLE TIME XXX.X (1.0 to 300.0 seconds)
CROSSOVER VALUE XX.X (0.1 to 300.0%)
CROSSOPVER BANDWIDTH XX.X (0 to crossover value in %
output)
OUTPUT HYST XX.X (0 to 25.0, in % output
centered on crossover value)
HEAT CYC TIME XXX.X (1.0 to 300.0 seconds)
HEAT CYC TIME XXX.X (1.0 to 300.0 seconds)
TUNE ** MENU**
Middle Bottom Description
Display Display
[OPEN TC X] Filed thermocouple (upscale
burnout)
[HIGH TCx] Overtemperature TC
[LOW TCx] Undertemperature TC
[RTDx LO] Failed RTD, low (active lead
shorted against another lead)
[RTDx HI] Failed RTD, high (any one lead
open
[CJCx BAD] Failed cold junction RTD
[MAx LOW] Out of range low for mA
[MAx HIGH] Out of range high for mA
[Vx LOW] Out of range low for V
[Vx HIGH] Out of range high for V
Middle Bottom Description
Display Display
[POWER] [FAILED] Power has been off due either
to a normal shutdown or an
acidental power failure
[MAIN CAL] [OPTNCAL] Factory calibration constants
missing or bad
[DB] [CHKSUM] Database checksum error.
Instrument could be operating
on bad data.
[ADCx TIM] Failure on the primary (1) or
remote setpoint input (2)
analog input ASIC
[ADCx INI] Initialization failure in the
primary (1) or remote setpoint
input (2) analog input ASIC
[ADCx UND] Underrange condition in the
primary (1) or remote set-point
input (2) analog input ASIC
Diagnostic Messages
Input Failure Messages
Optional FailureMessages
Relationship of Setup Functions
TAG
DISPLAYS **MENU**
Displays Menu
BASE CFG **MENU**
Base Configuration
Menu
INPUTS **MENU**
Inputs Menu
DIG INPT **MENU**
Digital Input Menu
MA. OUTP **MENU**
Milliamp Output
RELAYS **MENU**
Output Relays Menu
SETPTS **MENU**
Set-Points Menu
RS-485 **MENU**
RAT BIAS **MENU**
Auto/Manual Ratio
Bios Menu
RAMPSOAK **MENU**
Ramp/Soak Profile
Menu
TOTALIZE **MENU**
Integrator/Totalizer
Menu
ALARMS **MENU**
Alarm Setting Menu
TUNE **MENU**
Tune MEnu
See IB-23C650M
NOTE:
Press UP or DOWN
Key to move from
menu to menu
Press SCROLL key to
enter seelcted menu
Press TAG key from
any top level menu to
return to the process
display.
Password, Mode key:
Configure,
Manual
Configure,
A/M, Hold
Tune, A/M
operator accesses 12 menus through the setup keys
summarized in the chart on the reverse side. For
Moves through the basic
Scroll: • Advancestostepl. * BRD CALIBRAT
Enters a YES response. ARE YOU SURE? YES, NO
(
If YES, all confi
g
ura- or SKIP LOCKOUT RAT BIAS TYPE RATIO, BIAS, RAT BIAS SEG 1 SOAK TIM XXX.
X
(
0 to 3000.0 hours o
r
Down: • Moves down through tion data is written over with TOTALIZE DI1 FUNC RUN/STOP, RUN/RSET, RATIO SOURCE LOCAL, REMOTE minutes)
menus. factory default values) RUN/HOLD
(
See IB-23C650
)
BIAS SOURCE LOCAL, REMOTE SEG 1 RMP RATE XXX.
X
(
Chan
g
e
p
er unit time in
Decreases values. CONFIG CHANGED For information only R/H, RSET LOCKOUT YES, NO
(
See IB-23C650 fo
r
RATIO BALANCE STANDARD
(
Ma
y
bum
p
when en
g
ineerin
g
units
)
Enters a NO response. SOFTWARE VERSION For information only or RESET LOCKOUT ex
p
lanation
)
switchin
manual to auto
,SEG 1 RELAY A ON, OFF
DISPLAY VERSION For information only or RUN/HOLD LOCKOU
T
AUTO
(
Bum
p
less Transfer
)
SEG 1 RELAY B ON, OFF
Top/Middle Display Bottom Display/Entry R/L KEY LOCKOUT YES, NO Not valid if source is remote. SEG 1 RELAY C ON, OFF
BASE CFG **MENU** INPUTS **NENU* LOC-REM ALLOWED NO, YES BIAS BALANCE Same entries as Ratio SEG 1 GUARANTD NO, YES
MAIN PWR FREQ 60 HERTZ, 50 HERTZ DECIMAL POINT 0., 0.0, 0.00, 0.000 DIG IN 1 ACTION REVERSE, DIRECT Balance SEG 2 SETUP Entry point for Segment 2.
PROC INP TYPE MILLIAMP
(
0 to 54 mA dc
)
,PROC INP SETUP Entr
y
p
oint for in
p
ut setu
p
DIGITAL INPUT 2 Entr
y
p
oint for Di
g
ital In
p
ut 1. RATIO SOURCE LOCAL, REMOTE. For ratio and Same ste
p
s as for Se
g
ment 1.
VOLT
(
0 to 6V dc
)
,PRC TEMP UNITS CELSIUS, FAHRENHT Same ste
p
s as Di
g
ital In
p
u 1. Bias t
yp
e. Onl
y
one remote Re
p
eat for Se
g
ments 3-10.
THERMCPL
(
Thermocou
p
le
)
,PROC INP MA. HI
X
X. XX
(
1.00 to 54.00 mA dc
)
,DI SETPT SEL LIST
(
15 combinations available, source allowed.
RTD
(
RTD In
p
ut
)
, or MV. HI XX. X
(
0 to 120 mV dc
)
,see IB-23C650 for listin
g)
BIAS SOURCE LOCAL, REMOTE. For ratio and TOTALIZE **MENU*
*
MILLIVLT
(
-10 to 120 mV dc
)
or VOLTS. HI X.XX
(
0.00 to 5.OOV dc
)
Bias t
yp
e. Onl
y
one remote WRAP AT PRED CNT NO
(
Counts until turned off or
SLIDEWIR
(
0 to 100% slide- PROC HI POSITION - X .XXX
(
0.000 to 1.000
)
MA. OUTP **NENU
*
source allowed. max. count reached
)
,
wire wiper position) PROC INP MA. LO OUTPUT MA. HIGH XX.X
(
01.0 to 54.0 mA dc
)
RATIO BALANCE For Ratio and Bias t
yp
e. Same YES
Counts to
redetermine
PROC INP IC TYPE TYPE *
(
J, K, E, R, 5, T, B, N
)
o
r
MV. LO XX. XX
(
0.00 to 53.00 mA do
)
. OUTPUT MA. LOW XX.X
(
0 to mA Hi
g
h less 1 mA dc
)
entries as Ratio Balance. count & wra
p
s to
p
reset value
)
PROCESS TEMP CAL Entry point tor temperature or VOLTS LO XX.X
(
-10.0 to llOmVdc
)
. HEAT OUT HI LIMIT XX.
X
(
0.1 to 110.00/0 of heat BIAS BALANCE For Ratio and Bias t
yp
e. Same INPUT THRSHOLD XXX
X
(
0 to En
g
ineerin
g
Unit
s
correction PROC LO POSITION XXX (0.00 to 4.90 V dc) output span) entries as Ratio Balance. High Value, in eng. units)
PR TEMP= XXX.X XX.
X
(
XXX.X = Process tem- XXXX
(
0.000 to 0.900
)
COOL OUT HI LIMIT XX.X
(
0.1 tO 110.0% of cool TOTALIZE IS OFF For information onl
y
perature, XX.X = Temperature PROCESS LIN TYPE NONE, SQR ROOT output span) SETPTS **MENU** or IS ON
correction [+15 to -15]) PROC ENG UNITS HI XXXX (-3000 to 30000) OUTPUT HI LIMIT XX.X
(
10.0 to 110% of mA LOC SETP Entr
y
p
oint for set-
p
oint setu
p
TOTALIZE DIRECT UP, DOWN
INPUT 2 ENABLE NO, YES PROC ENG UNITS LO XXXX (-3000 to 30000) output span, 10.0 to 100% of LOC SETP FIXED NO, YES TOTALIZE RATE PER SEC, PER MIN, PER HOUR
INPUT 2 TYPE Same steps as Input1 type PR FAULT OUTPUT - XX (0 to 100%) relay output span) LOC SETP HI LIMIT XXXX (Low limit to 30000) SCALE DEC PT 0., 0.0, 0.00, 0.000
PR FAULT LEVL PCI XX (0 to 100%). See OUTPUT LO LIMIT XX.X
(
-8% or 0% rela
y
to LOC SETP LO LIMIT XXXX
(
-3000 to hi
g
h limit
)
SCALE FACTOR XXX
X
(
0.001 TO 30000
)
OUTPUT TYPE CUR PROP
(
Current
p
ro
p
.
)
,IB-23C650 for limits hi
g
h limit less 1.0%
)
LOC SETP INIT VAL XXX X
(
Low limit to hi
g
h limit
)
PRESET VALUE XXXXXX
X
(
.000 to 9999999
)
POS PROP
(
Position
p
ro
p
.
)
,RECOVERY OPTION MANUAL, LAST LIMIT IN MANUAL NO, YES=Limits a
pp
l
y
in Manual SETPT 2 Entr
y
p
oint for set-
p
oint 2 FREDETRD COUN
T
XXXXXX
X
(
.000 to 9999999
)
HC/R
R
(
Heat/Coo/, dual rela
y)
,POWER UP OUTP SRC LAST, FIXED SETPT 2 ENABLE NO, YES
HC/CR
(
HeatiCool, mA/rela
y)
,INPUT 2 SETUP Same ste
p
s as Process In
p
ut1 FIXED PWR UP OUTPT
X
X.X
(
-8.0 to 110.0, within Out- ALARMS **MENU*
*
HC/CC
(
Heat/Cool, dual mA
)
, Setu
p
thru En
g
. Units Low
p
ut hi
g
h and low limits
)
SETPT 2 FIXED Same ste
p
s as Set-
p
oint 1 BEEP ON OCCUR OF NONE, or an
y
combination of:
ON/OFF
(
On,Off
)
,I2 FAULT ACTION NONE, LOCAL
(
Controller
p
ut in Fixed thru Initial Value. DG, P1, P2
TIM PROP
(
Time
p
ro
p
ort.
)
auto mode with fault value
)
RETRANS VARIABLE PROCESS, SETPOINT, Re
p
eat for Set-
p
oints 3 and 4 ALARM ACK REQD ON NONE, or an
y
combination of:
POS PROP has position choice NONE
(
Fix out
p
ut 2 at 0 mA
)
POWER UP SETP SRC LAST, LOC SETPT. SETPT 2, DG, P1, P2
CONTROL ACTION DIRECT, REVERSE I2 FAULT VALUE XXXX (-3000 to 30000) RETRANS PROC HI XXX
X
(
-3000 to 30000
)
Decima
l
SETPT 3, SETPT 4, REM SETP OVERCFGD DIAG ON YES , NO
MA. OUTP ACTION DIRECT, REVERSE I2 FAULT LEVL PCI XX (0 to 100%) or SETPT HI placed per "Inputs" Menu. INPUT 2 MISSING Warning message. times out in P1 RELAY ACTION LATCHING
(
rela
y
release
s
HEAT OUT ACTION DIRECT, REVERSE RETRANS PROC LO XXX
X
(
-3000 to 30000
)
Decma
l
1 second. when alarm acknowled
g
ed
)
,
COOL OUT ACTION DIRECT, REVERSE ENG UNIT LABEL XXXX
(
X=an
y
character in Ta
g
or SETPT LO
p
laced
p
er "In
p
uts" Menu. FIXD PWR UP SETPT XXXX
(
-3000 to 30000, within NO LATCH
(
rela
y
release
s
VALVE CALIB See IB-23C650. Name field in Tune menu) local set-point limits) when alarm condition not
HOLD PWR UP MSG NO, YES
(
Hold ‘POWE
R
RIGHT BAR OUTPUT
(
Out
p
ut dis
p
la
y
ed
)
OUTPUT 2 MA. HIGH XX. X
(
01.0 to 54.0 mA dc
)
SETPOINT TRACKING NO, YES
(
Note: Remote se
t
p
resent
)
FAILED’ message at startup) DEVIATN
(
Deviation dis
p
la
y
ed
)
OUTPUT 2 MA. LOW XX. X
(
0 to 53.0 m
A
p
oint cannot track
)
POWER UP MODE LAST, AUTO, MANUAL 0EV BAR FULL SCL XX
(
1 to 100% of s
p
an
)
DISPLAYS AND ENTRIES Top/Middle Display Bottom Display/Entry Top/Middle Display Bottom Display/Entry Top/Middle Display Bottom Display/Entry Top/Middle Display Bottom Display/Entry
RAT BIAS ENABLE NO, YES DIG INPT **MENU** RELAYS **MENU** RAMPSOAK **MENU*
The MODCELL 2050 generates display prompts to AUTOTUNE ENABLE NO, YES DIGITAL INPUT 1 Entry point for Digital Input 1. RELAY A SETUP Entry point for Relay A setup RAMPSOAK REPEAT NO, YES
make setup and operation fast and easy. The RAMPSOAK ENABLE NO, YES DIG IN 1 FUNCTION NONE, AUTO/MAN, ALRM ACK, RELAY A FUNCTION NONE, ALARMS, TOTALIZE, SOAK HYST XXX
X
(
0 to 30000
)
TOTALIZE ENABLE NO, YES TOTALIZE, RAMPSOAK, RAMPSOAK, REM/LOC, RAMP HYST XXX
X
(
0 to 30000
)
described below. The sequence of menus is RS-485 ENABLE YES, NO SETP SEL AUTO/MAN RAMPSOAK IS OFF For information only
TUNE PASSWORD XXXX (Enter this value [0 to DIG A-M OUT ENAB NO, YES RELAY A TRIP ACT On alarm
s
1, 2, 3, 4, 12, 13 o
r
IS ON
more detailed information, see IB-23C650. 30000] in ‘Displays’ menu) DIG A-M OUT VAL XX.
X
(
0 TO 54.0 mA
)
14, 23, 24, 34, 123, 124, 134, RAMPSOAK UNIT TIM MINUTES, HOURS
CONFIG PASSWORD XXX
X
(
Enter this value
[
0 to A/M KEY LOCKOUT YES, NO 234, 1234 RAMPSOAK SEGMENTS XX
(
0 to 10
)
30000] in Displays menu) MAN-AUTO ALLOWED NO, YES RELAY B SETUP Same steps as Relay A Setup. SEG 1 SETUP Entry point for Segment 1
setup steps. CHK SUM DATABASE YES (ARE YOU SURE?), NO RAMPSOAK DI1 FUNC RUN/STOP, RUN/HOLD, RELAY C SETUP Same steps as Relay A Setup. SEG 1 START SP XXXX
(
Local Set-
p
oint Low Limit
See IB-23C650. RUN/SKIP
(
See IB-23C650
)
to Local Set-
p
oint Hi
g
h Limit
)
Up: Moves up through menus. DEFAULT DATABASE Up key requests default R/H, RSET LOCKOUT YES, NO
(
See IB-23C650 fo
r
RS-485 **MENU* See IB-23C650M SEG 1 END SP
X
XXX
(
Local Set-
p
oint Low Limit
Increases values. LOCK CFG MENUS NO=Reaci access, YES or RUN/HOLD LOCKOU
T
ex
p
lanation. RAT BIAS **MENU*
*
to Local Set-
p
oint Hi
g
h Limit
)
  • Page 1 1
  • Page 2 2