Lightolier 8605 User manual

Type
User manual

Lightolier 8605:

This fixture is designed to be installed in accordance with the National Electrical Code and local or Federal code specifications. You should check with your local electrical inspector before installation to ensure full compliance with codes and regulations. Additionally, turn off the electricity at the fuse box before proceeding to prevent electric shock.

The Lightolier 8605 is a point power jack for 8600 Lytejack fixtures. It is intended to be mounted directly to the ceiling or wall if the material is dense enough (such as 1/2” plywood or 3/4” plasterboard) and firmly attached to a substantial structure. If the ceiling or wall does not meet these requirements, you will need to use the T-bar accessory No.8618.

Lightolier 8605:

This fixture is designed to be installed in accordance with the National Electrical Code and local or Federal code specifications. You should check with your local electrical inspector before installation to ensure full compliance with codes and regulations. Additionally, turn off the electricity at the fuse box before proceeding to prevent electric shock.

The Lightolier 8605 is a point power jack for 8600 Lytejack fixtures. It is intended to be mounted directly to the ceiling or wall if the material is dense enough (such as 1/2” plywood or 3/4” plasterboard) and firmly attached to a substantial structure. If the ceiling or wall does not meet these requirements, you will need to use the T-bar accessory No.8618.

2000
INSTRUCTION SHEET NO.
A0300 Page 1of 1
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal
code specifications. To assure full compliance with codes and regulations, check with your local electrical
inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
631 Airport Road, Fall River, MA 02720
LIGHTOLIER a GENLYTE THOMAS company.
IS:8605
POINT POWER JACK FOR 8600 LYTEJACK FIXTURES
NOTE: ACCESS ABOVE CEILING OR BEHIND WALL REQUIRED DURING INSTALLATION.
POINT
POWER
JACK
LEADS (2)
SPRING TAB
LABEL ON BOTTOM
OF FLANGE
MAXIMUM WATTAGE LABELS
ATTACH AT INSTALLATION
ATTACH AT INSTALLATION
GAP
CAPS
FLANGE
IF THE CEILING OR WALL IS MADE FROM A DENSE MATERIAL SUCH
AS 1/2” PLYWOOD OR 3/4” PLASTERBOARD AND IS FIRMLY
ATTACHED TO SUBSTANTIAL STRUCTURE THEN THE POINT POWER
JACK CAN BE MOUNTED DIRECTLY TO THE CEILING OR WALL AS
SHOWN BELOW.
(* IF THE CEILING OR WALL DOES NOT MEET THESE
REQUIREMENTS, USE T-BAR ACCESSORY NO.8618).
NOTE: THE MAXIMUM WATTAGE LABEL SELECTED FOR THIS
POWER JACK MUST CORRESPOND TO THE MARKINGS ON THE
TRANSFORMER LABEL.
1. Peel the appropriate MAXIMUM WATTAGE LABEL from its backing
and adhere it to the gap in the LABEL on the FLANGE of the
POINT POWER JACK (Fig. 1).
2. Select the CAP with the same MAXIMUM WATTAGE marking and
snap it over the FLANGE (Fig. 2).
NOTE: Use the 35W MAXIMUM WATTAGE LABEL and CAP for
fixtures that have screw-in adapters (Fig. 2).
FIG. 1
FIG. 2
2
INSTRUCTION SHEET NO.
A0300 Page 2of 2
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal
code specifications. To assure full compliance with codes and regulations, check with your local electrical
inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
3. DRILL a 1 1/8”diameter hole in the ceiling or wall. Locate the
hole at least 12” from any flammable objects and 3” from any
structure.
4. Insert the POWER JACK POINT into the hole in the ceiling or
wall until the FLANGE is seated against the ceiling or wall and
held in place by the SPRING TABS.
NOTE: The SPRING TABS are to Temporarily retain the POINT
casting until it has been permmanently fastened in place.
DO NOT ATTEMPT TO CONNECT OR USE THE POWER JACK UNTIL THEN.
5. Slip the WASHER and LOCK NUT past the leads and onto the
POINT casting as shown. Thread the LOCK NUT onto the casting
until the FLANGE is snug to the ceiling or wall.
6. Thread the leads through FLEXIBLE CONDUIT (not included) and
splice to the remote transformer Cat. No. 8608 or No 8609 (Fig 3).
NOTE: The leads must go directly to the transformer and not to
another POWER POINT. Otherwise excessive voltage drop
will affect the brightness and color of the light.
CAUTION: USE ONLY WITH JACKS MANUFACTURED BY LIGHTOLIER.
USE OF OTHER EQUIPMENT VOIDS THE WARRANTY AND
MAY CREATE A HAZARD.
IS:8605
Fig. 3
POINT POWER JACK
SPRING TAB
FLEXIBLE CONDUIT
(NOT INCLUDED)
FITTING FOR
TRANSFORMER BOX
(NOT INCLUDED)
FLANGE
CEILING OR WALL
LOCK NUT
WASHER
90˚ CONNECTOR
  • Page 1 1
  • Page 2 2

Lightolier 8605 User manual

Type
User manual

Lightolier 8605:

This fixture is designed to be installed in accordance with the National Electrical Code and local or Federal code specifications. You should check with your local electrical inspector before installation to ensure full compliance with codes and regulations. Additionally, turn off the electricity at the fuse box before proceeding to prevent electric shock.

The Lightolier 8605 is a point power jack for 8600 Lytejack fixtures. It is intended to be mounted directly to the ceiling or wall if the material is dense enough (such as 1/2” plywood or 3/4” plasterboard) and firmly attached to a substantial structure. If the ceiling or wall does not meet these requirements, you will need to use the T-bar accessory No.8618.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI