-INSTRUCTION MANUAL-
IB(NA)-0600110E-A (0203) MEE
VECTOR INVERTER
Printed in Japan Specifications subject to change without notice.
HEAD OFFICE:MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310
FR-V5AH
16-BIT DIGITAL INPUT
A-1
Thank you for choosing the Mitsubishi vector inverter option unit.
This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling
might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment
to its optimum.
Please forward this manual to the end user.
1. Electric Shock Prevention
This section is specifically about safety matters
Do not attempt to install, operate, maintain or inspect this product until you have read through this instruction man-
ual and appended documents carefully and can use the equipment correctly. Do not use this product until you have
a full knowledge of the equipment, safety information and instructions.
In this instruction manual, the safety instruction levels are classified into "WARNING" and "CAUTION".
Assumes that incorrect handling may cause hazardous conditions, resulting in
death or severe injury.
Assumes that incorrect handling may cause hazardous conditions, resulting in
medium or slight injury, or may cause physical damage only.
Note that the CAUTION level may lead to a serious consequence according to conditions. Please follow the instruc-
tions of both levels because they are important to personnel safety.
SAFETY INSTRUCTIONS
!
While power is on or when the inverter is running, do not open the front cover. You may get an electric shock.
!
Do not run the inverter with the front cover removed. Otherwise, you may access the exposed high-voltage termi-
nals and charging part and get an electric shock.
!
If power is off, do not remove the front cover except for wiring or periodic inspection. You may access the
charged inverter circuits and get an electric shock.
!
Before starting wiring or inspection, switch power off, wait for more than 10 minutes, and check for no residual
voltage with a tester or the like.
WARNING
CAUTION
WARNING
A-2
2. Injury Prevention
3. Additional instructions
Also note the following points to prevent an accidental failure, injury, electric shock, etc.:
(1) Transportation and mounting
(2) Test operation and adjustment
!
Any person who is involved in the wiring or inspection of this equipment should be fully competent to do the work.
!
Always install the option unit before wiring. Otherwise, you may get an electric shock or be injured.
!
Handle this option unit with dry hands to prevent an electric shock.
!
Do not subject the cables to scratches, excessive stress, heavy loads or pinching. Otherwise, you may get an electric shock.
!
Apply only the voltage specified in the instruction manual to each terminal to prevent burst, damage, etc.
!
Ensure that the cables are connected to the correct terminals. Otherwise, burst, damage, etc. may occur.
!
Always make sure that polarity is correct to prevent burst, damage, etc.
!
While power is on or for some time after power-off, do not touch the inverter as it is hot and you may get burnt.
!
Do not install or operate the option unit if it is damaged or has parts missing.
!
Do not stand or rest heavy objects on the product.
!
Check that the mounting orientation is correct.
!
Prevent screws, metal fragments or other conductive bodies or oil or other flammable substance from entering the inverter.
!
Before starting operation, confirm and adjust the parameters. A failure to do so may cause some machines to
make unexpected motions.
WARNING
CAUTION
CAUTION
CAUTION
A-3
(3) Usage
(4) Maintenance, inspection and parts replacement
(5) Disposal
(6) General instruction
!
Do not modify the equipment.
!
When parameter clear or all parameter clear is performed, each parameter returns to the factory setting. Re-set
the required parameters before starting operation.
!
For prevention of damage due to static electricity, touch nearby metal before touching this product to eliminate
static electricity from your body.
!
Do not test the equipment with a megger (measure insulation resistance).
!
Treat as industrial waste.
All illustrations given in this manual may have been drawn with covers or safety guards removed to provide in-
depth description. Before starting operation of the product, always return the covers and guards into original posi-
tions as specified and operate the equipment in accordance with the manual.
WARNING
CAUTION
CAUTION
CAUTION
CONTENTS
1.PRE-OPERATION INSTRUCTIONS 1
1.1 Unpacking and Product Confirmation..................................................................................................1
1.2 Packing Confirmation...........................................................................................................................1
1.3 Structure ..............................................................................................................................................2
2.INSTALLATION 3
2.1 Pre-Installation Instructions..................................................................................................................3
2.2 Installation Procedure..........................................................................................................................3
2.3 Wiring...................................................................................................................................................5
3.16-BIT DIGITAL INPUT 8
3.1 Wiring Examples..................................................................................................................................8
3.2 Terminals...........................................................................................................................................10
3.3 Code Input .........................................................................................................................................11
4.DIGITAL SPEED COMMAND 12
4.1 Digital Speed Command Parameter..................................................................................................12
4.2 Parameter Setting..............................................................................................................................13
4.3 Instructions.........................................................................................................................................17
5.DIGITAL TORQUE COMMAND 18
5.1 Digital Torque Command Parameters ...............................................................................................18
5.2 Parameter Setting..............................................................................................................................18
5.3 Instructions.........................................................................................................................................20
6.ORIENTATION POSITION COMMAND 21
6.1 Orientation Position Command Parameter........................................................................................21
6.2 Parameter Setting..............................................................................................................................21
7.SPECIFICATIONS 23
7.1 Specifications.....................................................................................................................................23
1
1.PRE-OPERATION INSTRUCTIONS
1.1 Unpacking and Product Confirmation
Take the option unit out of the package, check the unit name, and confirm that the product is as you
ordered and intact.
This product is an option unit designed for exclusive use in the Mitsubishi FR-V500 series vector inverter.
" SERIAL number check
This product may be used with the FR-V500 series manufactured in and after March 2002. Any of the
models may be used with this unit if its SERIAL number indicated on the rating plate and package has
"#23######" or later version. For details of the SERIAL number, please contact your sales repre-
sentative.
SERIAL is made up of 1 version symbol, 1 alphabet letter or numeric character indicating month, and 7
numeric characters indicating the year and control number as shown below. (Only the first three digits
of the control number are printed on the package.)
SERIAL number
1.2 Packing Confirmation
Make sure that the package includes the following
" Instruction manual.........................................................................1
" Mounting screws M3 × 10 .............................................................2
#
2 3 ######
Symbol Year Month Control number
2
PRE-OPERATION INSTRUCTIONS
1.3 Structure
FR-V5AH
SD
SD
SD
X0
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
DY
X15
Connector
Mounting
hole
Terminal
Terminal
symbol
Front view
Mounting holes
Option fixing holes
Rear view
Mounting
hole
3
2.INSTALLATION
2.1 Pre-Installation Instructions
Make sure that the input power of the inverter is off.
2.2 Installation Procedure
(1) Securely insert the connector of the option unit far into the connector of the inverter. At this time, fit the
option fixing holes snugly.For the position of slot, refer to the next page.
Also be sure to fit the unit into the option fixing hook.
(2) Securely fix the option unit to the inverter on both sides with the accessory mounting screws. If the
screw holes do not match, the connector may not have been plugged snugly. Check for loose plugging.
With input power on, do not install or remove the option unit. Otherwise, the inverter and
option unit may be damaged.
CAUTION
4
INSTALLATION
CAUTION
1. Only one type of option per inverter may be used. When two or more options are mounted, pri-
ority is in order of slots 1, 2 and 3, the options having lower priority are inoperative.
2. When the inverter cannot recognize that the option is
mounted, it displays the option error. The errors shown
differ according to the mounting slots 1, 2, 3.
Option unit
Accessory screw
(2 pcs.)
Option side
connector
Inverter
(without cover)
Slot 1
Inverter side connector
Slot 2
Slot 3
Option fixing hook
The slots 1, 2, and 3 are provided
with an option fixing hook.
Mounting Position Error Display
Slot 1 E.OP1
Slot 2 E.OP2
Slot 3 E.OP3
5
INSTALLATION
2.3 Wiring
Wiring method
1) For wiring the control circuit, use cables after stripping their sheaths.
Strip the sheaths to the following dimensions. If the sheath is stripped too much, its cable may be shorted
with the adjoining cable. If the sheath is stripped too little, the cable may come off.
*Information on bar terminals
Introduced products (as of Mar., 2002): Phoenix Contact Co.,Ltd.
Bar terminal crimping terminal: CRIMPFOX ZA3 (Phoenix Contact Co., Ltd.)
Wire the stripped cable after twisting
it to prevent it from becoming loose.
In addition, do not solder it.*
Terminal Screw Size
Bar Terminal Model
(With Insulation Sleeve)
Bar Terminal Model
(Without Insulation Sleeve)
Wire Size (mm
2
)
M2 Al 0.5-6WH A 0.5-6 0.3 to 0.5
CAUTION
When using the bar terminal (without insulation sleeve), use care so that the twisted wires do not
come out.
Cable stripping size
5
6
INSTALLATION
2) Loosen the terminal screw and insert the cable into the terminal.
Screw size: M2
Tightening torque: 0.22N·m to 0.25N·m
Cable size: 0.3mm
2
to 0.75mm
2
Screwdriver: Small flat-blade screwdriver
(Tip thickness: 0.4mm (0.02inches)/tip width: 2.5mm (0.10inches))
CAUTION
Undertightening can cause cable disconnection or malfunction. Overtightening can cause a short
circuit or malfunction due to damage to the screw or unit.
7
INSTALLATION
Route the wires so that they do not take up a lot of space in the control circuit terminal block of the option unit.
During wiring, do not leave wire off-cuts in the inverter. They may cause a fault, failure or malfunction.
Use the space on the left side of the control circuit terminal unit to route the wires.
REMARKS
The wires with large gaze may not be connected to the terminal block. When connected in parallel, all wires may not
fit in the wiring space due to the increased number of wires. In such cases, perform wiring by using a junction termi-
nal block.
When installing the inverter front cover, the cables to the inverter's control circuit terminals
and option terminals should be routed properly in the wiring space to prevent them from
being caught between the inverter and its cover.
Cable routing
CAUTION
8
3.16-BIT DIGITAL INPUT
3.1 Wiring Examples
*1 Use the terminal PC on the inverter.
*2 AY41 type unit requires 24VDC power.
A wiring example of Mitsubishi PLC output module (AY41 type). For details of the output module, refer
to the instruction manual of the output module.
(1)Relay contact signal input (2)Open collector signal input
(For sink logic)
8
DY
FR-V5AH
SD
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
X0
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
Inverter
Y41 type transistor
utput module *2
X0
DY
FR-V5AH
PC
18
19
35
36
17
5
7
8
10
12
14
16
15
13
11
9
6
4
3
2
1
X1
X2
X3
X4
X5
X6
X7
X9
X10
X11
X12
X13
X14
X15
X8
*1
Read command
9
16-BIT DIGITAL INPUT
REMARKS
1. As the input signals are at low level, use two parallel micro signal contacts or a twin contact for relay contact
inputs to prevent a contact fault.
2. A transistor of the following specifications should be selected for the open collector signal: Electrical characteris-
tics of the transistor used
I
c
10mA
Leakage current: 100µ
µµ
µA maximum
V
CE
30V
If I
c
10mA, V
CE (sat)
voltage is 3V maximum
3. The control logic is the same as that of the inverter (factory-set to sink). When the logic of the inverter is
changed to source, the option logic also switches to source. For details on changing the control logic, refer to the
inverter instruction manual (basic).
Micro signal contancts Twin contancts
10
16-BIT DIGITAL INPUT
3.2 Terminals
Terminal
Location
Terminal Symbol Description
Option unit
X0 to X15
Digital signal input terminals (speed setting signal terminals)
Used to input a 4-digit BCD (9999 maximum) or 16-bit binary (FFFF
H maxi-
mum) relay contact or open collector signal. (refer to page 11)
DY
Data read timing input signal
Used when a digital signal read timing signal is necessary.
Data is only read while the DY signal is on.
By switching the DY signal off, the X0 to X15 data before signal-off is retained.
(Refer to page 13.)
SD
Common terminal (sink)
Common terminal for digital and data read timing signals.
This terminal is the SD terminal of the inverter. Common terminal for the SD
terminal of the inverter.
Inverter PC
External transistor common terminal (source)
When connecting the transistor output (open collector output) of a programma-
ble controller (PC), etc., connect the external power common (+) to this termi-
nal to prevent a fault occurring due to leakage current. When you have selected
the source logic, this terminal is used as a common terminal. This terminal is
the PC terminal of the inverter.
11
16-BIT DIGITAL INPUT
3.3 Code Input
The following lists examples of terminal input state and input value for BCD code and binary code input.
In the case where BCD code is "6325" In the case where Binary code is "AB65
H
"
BCD Code Input Binary code input
Digit Terminal
Terminal input
state
Input value Terminal
Terminal input
state
Input value
(hexadecimal)
Input value
(decimal)
1
X0 ON
5
X0 ON
5
43877
X1 OFF X1 OFF
X2 ON X2 ON
X3 OFF X3 OFF
10
X4 OFF
2
X4 OFF
6
X5 ON X5 ON
X6 OFF X6 ON
X7 OFF X7 OFF
100
X8 ON
3
X8 ON
B
X9 ON X9 ON
X10 OFF X10 OFF
X11 OFF X11 ON
1000
X12 OFF
6
X12 OFF
A
X13 ON X13 ON
X14 ON X14 OFF
X15 OFF X15 ON
CAUTION
Range of each digit is from 0 to 9. If the value of a digit is greater than 9, the value is invalid and
the previous value is kept.
12
4.DIGITAL SPEED COMMAND
4.1 Digital Speed Command Parameter
Use the following parameters to give a speed command using the FR-V5AH. The following parameters can
be set when the FR-V5AH is fitted.
This option unit does not function if the parameter values are factory setting values. When Pr.304
"9999",
a speed command by the 16-bit digital input is made valid.
Set the following parameter values according to the application:
Parameter
Number
Function name
Setting
Range
Setting
Increments
Factory
Setting
300
BCD code input
Bias 0 to 3600r/min 0.1r/min 0r/min
301 Gain 0 to 3600r/min, 9999 1r/min 1500r/min
302
Binary input
Bias 0 to 3600r/min 0.1r/min 0r/min
303 Gain 0 to 3600r/min, 9999 1r/min 1500r/min
304
Selection of digital input type and analog
compensation input enable/disable
0, 1, 2, 3, 9999 1 9999
305 Data read timing signal on-off selection 0, 1 1 0
329 Digital input unit selection 0, 1, 2 1 1
REMAKS
• For Pr.329, write is disabled during operation even when "2" is set in Pr.77. When changing the parameter setting,
stop the operation.
• Binary input. . . . . . . load input data in hexadecimal
BCD code input . . . load input data in decimal
13
DIGITAL SPEED COMMAND
4.2 Parameter Setting
(1) Input selection (Pr.304 "selection of digital input type and analog compensation input enable / disable." )
You can select the digital input signal type and whether compensation for digital input by analog input
is enabled or not. When the setting is "9999" (factory setting), the 1
6-bit digital input speed command
is invalid.
[Relationship between the Pr. 304 setting and analog compensation input enable/disable]
*: The analog compensation input signal is entered across inverter 1-5. For the setting of "0"
or "1", the analog compensation input is not accepted.
Digital Input
Signal Type
Analog Compensation Input*
Compensation
disable
Compensation
enable
BCD code input 0 2
Binary input 1 3
14
DIGITAL SPEED COMMAND
(2) Data read timing signal on-off selection (Pr.305)
! How to use DY signal
Pr.305 setting Description
0
The set speed data entered from the digital signal input terminals is always imported independently
of whether the DY signal is on or off.
1
The set speed data entered from the digital signal input terminals is imported only when the DY sig-
nal is on. The set speed data is not imported when the DY signal is off. Therefore, if the input status
of the X0-X15 signal changes, the set speed data before off of the DY signal is valid.
REMARKS
When Pr. 305 = "1", all the X0 to X15 terminals are regarded as off if the inverter is switched on with the DY terminal
off. For example, when bias is set to 500r/min, powering on the inverter with the DY signal off and turning the start
signal on makes the speed command valid, starting the inverter to operate at 500r/min.
OFF ON
50ms or longer necessary
Digital signal input
(terminals X0 to X15)
Data read timing signal
(across terminals DY-SD)
1ms or longer 1ms or longer
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Mitsubishi Electric FR-A5AX User manual

Category
Power adapters & inverters
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI