D 3 GTWechselrichter
Bedienungsanleitung
GB 7 CInverter
Instruction Manual
E 11 Convertidor de ondas seno
Instrucciones de uso
F15Onduleur
Notice d’emploi
I 19 Invertitore
Istruzioni per l’uso
NL 23 GInverter
Gebruiksaanwijzingen
DK 27 SVekselretter
Betjeningsanvisning
S 31 TVäxelriktare
Bruksanvisning
N 35 SVekselretter
Bruksanvisning
FIN 39 Tahdistettu vaihtomuunnin
Käyttöohjeet
titelseite_neu_a5.fm Seite 1 Donnerstag, 29. September 2005 3:50 15
2
Collected_MB-840.qxd 24/06/03 13:03 Page 2
6
Collected_MB-840.qxd 24/06/03 13:03 Page 6
7
Read these instructions before you start with the commissioning of the inverter.
Failure in observing these warnings may result in injuries to persons or damage to
materials.
General safety and installation instructions
Warning! The following fundamental safety
measures must be observed when using
electrical equipment to avoid danger of:
- electric shocks
- danger of fire
- injuries
About the unit itself
- Do not connect the 230 volts output from the
inverter with another 230 volts source.
- The inverter must only be used for the purpose
specified by the manufacturer!
- When working on the inverter, always
disconnect it from the mains!
- Even after triggering the safety device (fuse),
parts of the inverter still carry voltage!
- Do not operate the inverter if the housing or
cables are damaged!
- Maintenance and repair must only be carried
out by a qualified specialist who is familiar
with the dangers involved and aware of the
relevant regulations!
- The inverter must not be exposed to heat
sources (solar radiation, heating etc.) for to
avoid additional heating-up.
- The inverter must be kept in a safe place out of
the reach of children!
- Air inlet and outlets must not be covered.
- Ensure proper ventilation!
- The inverter may not be operated in a damp or
wet environment!
- The inverter must be positioned and secured
safely in order to avoid it being knocked over or
it falling down!
Caution when installing on boats!
- Wrong installation of electrical units on boats will
lead to corrosion of the boat. Therefore, please
let a (boat) electrician carry out the installation
of the inverter.
Electrical wires:
- If cables have to be led through metal walls or
other sharp-edged walls, use a cable duct or
cable bushes!
- Do not lay cables loose or in sharp bends on
electricity conducting materials (metal)!
- Do not pull on cables!
- Do not lay 230 V mains cable and 12/24 V DC
cable together into the same cable conduit
(cable duct)!
- Secure cables properly!
- When laying the cable, make sure there is no
danger of tripping over and of the cable being
damaged!
Intended use of the inverter
The inverters can be operated everywhere that a 12 V DC battery (for 840-012PP) or a 24 V DC
battery (for 840-024PP) is present. An increase in heat can develop at some units due to the non-sine-
shaped voltage. The maximum continuous rating amounts to 400 watts at the inverters 840-012PP and
840-024PP. Units with a higher power demand must not be connected.
Reference! It must be observed when installing units with electrical drive (e.g. power drill, refrigerator
etc.) that they often need higher capacity than indicated on the type plate.
Scope of delivery
1. Inverter
2. connecting cable with battery terminals
3. operating instructions
Collected_MB-840.qxd 24/06/03 13:03 Page 7
8
The start-up can be done with the “ON/OFF”
switch. The green control light-emitting diode
“POWER” lights up in the switch position “ON”.
Should the battery voltage falls below 10.7/21.4 V
during operation, an audible signal is emitted and
the red control light-emitting diode illuminates.
The inverter switches off if the battery voltage
drops further. When the heating is too strong, the
inverter switches off — the red control light-
emitting diode illuminates. Switch off the inverter
by means of the “ON/OFF“-switch. The inverter
can be switched on again after it has cooled
down. When operating the inverter during
longer period of time and with the largest load, it
is recommendable to start the motor in order to
recharge the battery of the vehicle. The inverter
can be operated with the motor running or
switched off. However, the motor should not be
started if the inverter is switched on.
Preparation and connection of the inverter
Commissioning of the inverter
Unscrew red knurl nut (6) and fasten the ring
eye (10) of the red connecting cable.
Unscrew black knurl nut (7) and fasten the
ring eye (11) of the black connecting cable.
To start-up the inverter, connect the red
terminal (+) with the positive pole (+) of the
battery and the black terminal (-) with the
negative pole (-) of the battery.
Make sure that the poles are clean when
connecting the battery.
1 230 V AC output
2 ”ON/OFF” control light-emitting diode
green
3 ON/OFF Switch
4 control light-emitting diode red
(overload- and undervoltage display)
5 Ventilator
6 Positive contact (red knurl nut)
7 Negative contact (black knurl nut)
8 Positive contact (red terminal)
9 Negative contact (black terminal)
10 Red ring eye
11 Black ring eye
Caution! Length and cross-section of the
connecting cable are synchronized to each
other! Do not modify without authorisation.
Make sure that the polarity will not be
exchanged! Reverse polarity connection will
blow the internal fuses. Exchange of fuses by
experts only!
1 2 3 4
5 6 7
8 9 10 11
Collected_MB-840.qxd 24/06/03 13:03 Page 8
9
Error detection
Error
No output voltage
Alarm tone during the operation
Unit switches On/Off cyclically
The inverter switches off when
the power consuming unit is
switched on.
Cause
Battery voltage is smaller than
10 V (840-012PP)
or 20 V (840-024PP)
Thermal overload
Fuse is defective (in the inverter
or in the vehicle)
Battery voltage is under
10.7 V (840-012PP)
or 21.4 V (840-024PP)
Poor contact at the battery with
load
Permanent load is too high
Switch-on current is too high
Troubleshooting
Load battery (start motor)
Switch off power consuming unit
let inverter cool down and
provide for better ventilation
Fuse to be replaced by a
qualified electrician
Charge battery
Cleaning the contacts
Reduce load
Comparison of the unit capacity
with the maximum capacity of
the inverter
Technical data
Article No. 840-012PP 840-024PP
Input nominal voltage: 10V~15V+/-0.3V 20V~30V+/-0.6V
Permanent output capacity (>4 hrs.): 400 W 400 W
Permanent output capacity (30 min.): 500 W 500 W
Peak output capacity (0.1 sec.): 1000 W 1000 W
Output voltage 210-230 V AC 210-230 V AC
Output frequency: 50 Hz 50 Hz
Efficiency with nominal output: 90 % 90 %
No-load current consumption: <0.15 A <0.15 A
Maximum ambient temperature: 40°C 40°C
Dimensions W x H x D: 105 x 57 x 225 mm 105 x 57 x 225 mm
Weight 1.2 kg 1.2 kg
Subject to changes due to technical progress and availability.
vorbehalten.
Reference! The output voltage of this rectangle inverter can be measured only correctly with an analog
indicator (pointer instrument).
If you have further questions about the inverter, please contact:
Collected_MB-840.qxd 24/06/03 13:03 Page 9
10
Collected_MB-840.qxd 24/06/03 13:03 Page 10
14
Collected_MB-840.qxd 24/06/03 13:03 Page 14
18
Collected_MB-840.qxd 24/06/03 13:03 Page 18
22
Collected_MB-840.qxd 24/06/03 13:03 Page 22
26
Collected_MB-840.qxd 24/06/03 13:03 Page 26
30
Collected_MB-840.qxd 24/06/03 13:03 Page 30
34
Collected_MB-840.qxd 24/06/03 13:03 Page 34
38
Collected_MB-840.qxd 24/06/03 13:03 Page 38
42
Collected_MB-840.qxd 24/06/03 13:03 Page 42
43
Collected_MB-840.qxd 24/06/03 13:03 Page 43
Europe
WAECO Schweiz AG
Riedackerstrasse 7a
CH-8153 Rümlang (Zürich)
+41 44 8187171
+41 44 8187191
Mail: info@waeco.ch
WAECO Danmark A/S
Tværvej 2
DK-6640 Lunderskov
+45 75585966
+45 75586307
Mail: waeco@waeco.dk
WAECO Ibérica S.A.
Camí del Mig, 106
Poligono Industrial Les Corts
E-08349 Cabrera de Mar
(Barcelona)
+34 93 7502277
+34 93 7500552
Mail: info@waeco.es
WAECO Distribution SARL
ZAC 2 · Les Portes de L‘Oise
Rue Isaac Newton – BP 59
F-60230 Chambly (Paris)
+33 1 30282020
+33 1 30282010
Mail: info@waeco.fr
WAECO Finland OY
Mestarintie 4
FIN-01730 Vantaa
+358 20 7413220
+358 9 7593700
Mail: waeco@waeco.fi
WAECO Italcold SRL
Via dell’Industria 4/0
I-40012 Calderara di Reno (BO)
+39 051 727094
+39 051 727687
WAECO Norge AS
Leif Weldingsvei 16
N-3208 Sandefjord
+47 33428450
+47 33428459
Mail: firmapost@waeco.no
WAECO Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
+31 76 5029000
+31 76 5029090
WAECO Svenska AB
Gustaf Melins gata 7
S-42131 Västra Frölunda
(Göteborg)
+46 31 7341100
+46 31 7341101
WAECO UK Ltd.
Dorset DT2 8LY · Unit G
Roman Hill Business Park
UK-Broadmayne
+44 1305 854000
+44 1305 854288
CH
DK
E
F
FIN
I
N
NL
S
UK
Overseas + Middle East
WAECO Pacific Pty. Ltd.
1 John Duncan Court
Varsity Lakes QLD 4227
+61 7 55076000
+61 7 55076001
WAECO Impex Ltd.
Suites 3210-12 · 32/F · Tower 2
The Gateway · 25 Canton Road
Tsim Sha Tsui · Kowloon
Hong Kong
+852 24632750
+852 24639067
WAECO Impex Ltd.
Taipei Office
2 FL-3 · No. 56 Tunhua South Rd, Sec 2
Taipei 106, Taiwan
+886 2 27014090
+886 2 27060119
Mail: marketing@waeco.com.tw
WAECO Middle East FZCO
R/A 8, SD 6
Jebel Ali, Dubai
+971 4 8833858
+971 4 8833868
Mail: waeco@emirates.net.ae
WAECO USA, Inc.
8 Heritage Park Road
Clinton, CT 06413
+1 860 6644911
+1 860 6644912
AUS
HK
ROC
UAE
USA
Headquarters
WAECO International GmbH · Hollefeldstraße 63 · D-48282 Emsdetten
+49 2572 879-195 · +49 2572 879-322 · Mail: [email protected] · Internet: www.waeco.de
D
www.waeco.com
3.03.18.01435 05/2007
adresse_A5_09.fm Seite 2 Freitag, 21. Juli 2006 2:51 14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Waeco PP500 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI