akira AC-S10CLG1 User manual

Category
Split-system air conditioners
Type
User manual

akira AC-S10CLG1 is an air conditioner with a cooling capacity of 9600 Btu/h and a power consumption of 1000 W. It has an air flow of 400 m³/h and a dehumidifying volume of 1.0 L/h. The unit has a compact design and is easy to install. The Swing Motor’s MP is 28 VA with a three amp fuse for the PCB and a 0.2 amp fuse for the transformer. It uses an aluminum fin evaporator with a copper tube and has a row-fin distance of 2-1.5 mm. It uses a hermetic motor compressor with a working temperature of less than 43º C and an aluminum fin condenser with a copper tube with a row-fin distance of 1-1.

akira AC-S10CLG1 is an air conditioner with a cooling capacity of 9600 Btu/h and a power consumption of 1000 W. It has an air flow of 400 m³/h and a dehumidifying volume of 1.0 L/h. The unit has a compact design and is easy to install. The Swing Motor’s MP is 28 VA with a three amp fuse for the PCB and a 0.2 amp fuse for the transformer. It uses an aluminum fin evaporator with a copper tube and has a row-fin distance of 2-1.5 mm. It uses a hermetic motor compressor with a working temperature of less than 43º C and an aluminum fin condenser with a copper tube with a row-fin distance of 1-1.

Air Conditioner
Service Manual
2
Model No.: AC-S10CLG1.doc
Version: 1.0
MODEL:AC-S10CLG1
3
Model No.: AC-S10CLG1.doc
Version: 1.0
CONTENTS
TECHNICAL SPECIFICATION………………………………………………………………………..4
PARTS NAME…………………………………………………………………………………………..5
SYSTEM DAIGRAM…………………………………………………………………………………...6
CIRCUIT DIAGRAM………………………………………………………………………...................8
DISASSEMBLY PROCEDURES……………………………………………………………………….9
EXPLODED VIEW AND PARTS LIST……………………………………………………………….18
GUIDE FOR INSTALLATION……………………………………………………………………….. 22
CARE AND MAINTENANCE…………………………………………………………………….…..29
MULFUNCTION ANALYSIS…………………………………………………………………………30
4
Model No.: AC-S10CLG1.doc
Version: 1.0
TECHNICAL SPECIFICATION
Model
AC-S10CLG1
Function Cooling /
Power Supply
1Ph 230V / 50Hz
Capacity (Btu/h) 9600 /
Rated Input (W) 1000 /
Rated Current (A) 5.7 /
Air Flow (m³/h) 400
Dehumidifying Volume (L/h) 1.0 /
EER ( W / W) 2.8 /
Model
AC-S10CLG1
Motor Fan Speed (rpm) 980
Output Fan Power (W) 13
Fan Type / Piece Cross Flow Fan – 1
Diameter – Length Φ 97mm – 583mm
Evaporator Aluminum Fin – Copper Tube
Row-Fin Distance (mm) 2 – 1.5
Swing Motor MP 28 VA
Fuse (A) PCB 3.15A Transformer 0.2A
Noise (db / (A)) < 37
Dimension (w x h x d)(mm) 770 x 190 x 250
Indoor Unit
Net Weight (kg) 8.0
Model
AC-S10CLG1
Input Power (W) 960 /
LRA (A) 4.5
Throtting Method Capillary
Compressor Hermetic Motor Compressor
Working Temp. < 43º C
Condenser Aluminum Fin-Copper Tube
Pipe-Diameter (mm) 9.52
Row-Fin Distance (mm) 1 – 1.6
Working Area /
Fan Motor Power (W) Speed
(rpm)
20 / 950
Fan Type-Piece Axial Flow Fan – 1
Diameter (mm) 320
Defrosting Method Auto Defrosting
Noise (db/ (A)) < 52
Dimension (w x h x d) (mm) 720x 260 x 430
Net Weight (kg) 25
Outdoor Unit
Refrigerant Charge R22 / 0.65
Liquid (mm) Φ 6
Outer Diameter
Gas pipe (mm) Φ 9.52
Height (m) 10
Connecting Pipe
Max. Distance
Length (m) 20
The technical data are subject to change without notice. Please refer to the nameplate of the unit.
5
PARTS NAME
Model No.: AC-S10CLG1.doc
Version: 1.0
6
SYSTEM DIAGRAM
When the power is on, the unit start to work. The compressor sucks low-pressure
refrigerant gas from the evaporator and discharges high-temperature and high-pressure
gas into condenser. Then air exchanges the heat with outdoor air and becomes
refrigerant liquid. The liquid is throttled by the capillary and changes into low-pressure
liquid and low-pressure liquid and then flows into indoor evaporator. The liquid
exchanges the heat and changes into low-temperature and low-pressure refrigerant gas,
the cycle introduced above goes on and on, and the demanded low temperature
environment is maintained.
Model No.: AC-S10CLG1.doc
Version: 1.0
7
When the power is on, indoor and outdoor units will start to run. When the system
operates in cool mode, the compressor sucks low-temperature refrigerant gas from the
evaporator an sucked by compressor, compressor into high-temperature, high-pressure
Gas, and then discharges into condenser, heat exchanges with the outdoor air becomes into
refrigerant liquid, the liquid is throttled by the capillary and the temperature and
pressure lower down, enter into the evaporator, heat exchanges with the indoor air which
need to be adjusted, then changes into low-temperature, low-pressure refrigerant gas, the
cycle introduced above goes on and on, the demanded low temperature environment is
maintained. (when in heat mode, the 4way valve changes its way and the refrigerant flows
in the reversible cycle, to make the condenser sucks heat, evaporator discharges heat, and
the demanded high temperature environment is maintained.
Model No.: AC-S10CLG1.doc
Version: 1.0
8
CIRCUIT DIAGRAM
Model No.: AC-S10CLG1.doc
Version: 1.0
9
DISASSEMBLY PROCEDURES
Model No.: AC-S10CLG1.doc
Version: 1.0
10
Model No.: AC-S10CLG1.doc
Version: 1.0
11
Model No.: AC-S10CLG1.doc
Version: 1.0
12
Model No.: AC-S10CLG1.doc
Version: 1.0
13
Model No.: AC-S10CLG1.doc
Version: 1.0
14
Model No.: AC-S10CLG1.doc
Version: 1.0
15
Model No.: AC-S10CLG1.doc
Version: 1.0
16
Model No.: AC-S10CLG1.doc
Version: 1.0
17
Model No.: AC-S10CLG1.doc
Version: 1.0
18
EXPLODED VIEW – Indoor Unit
Model No.: AC-S10CLG1.doc
Version: 1.0
19
Model No.: AC-S10CLG1.doc
Version: 1.0
PART LIST – Indoor Unit
NO. Part Code Part Description Qty
1 01252220 Wall Mounting Frame 1
2 222020012 Rear Case 1
3 01002072 Evaporator Assy 1
4 10352001 Cross Flow Fan 1
5 76512203 O-Gasket of Cross Fan Bearing 1
6 05232411 Drain Pipe 1
7 20182027 Water Tray 1
8 10512032 Air Louver 12
9 10582002 Swing Lever 1
10 10582003 Swing Lever 1
11 20002210 Front Case 1
12 24252006 Screw Cap 3
13 11122002 Filter 2
14 30512506 Remote Control Y512 1
15 68012019 Magic Mirror 1
16 30545702 Display Board 1
17 20002209 Front Panel 1
18 10512034 Guide Louver 1
19 10512033 Guide Louver 1
20 15212110 Stepping Motor 1
21 26112014 Motor Press Plate 1
22 15012064 Fan Motor 1
23 22242030 Electric Box Cover 1
24 42011240 4-bit Terminal Board 1
25 201220061 Electric Box Cover 1
26 20102178 Electric Box 1
27 30055787 Main Board 1
28 43110204 Transformer 1
29 71010103 Fixed Clamp 1
30 24242001 Pipe Clamp 1
31 40020540 Connecting Cable 1
32 Signal Cable
33 400202802 Power Cord 1
34 10582409 Press Plate of Swing Link 1
35 10582408 Swing Louver 1
36 10542004 Swing Louver(up) 1
37 10542005 Swing Louver(down) 1
The data are subject to change without prior notice
20
Model No.: AC-S10CLG1.doc
Version: 1.0
EXPLODED VIEW – Outdoor Unit
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

akira AC-S10CLG1 User manual

Category
Split-system air conditioners
Type
User manual

akira AC-S10CLG1 is an air conditioner with a cooling capacity of 9600 Btu/h and a power consumption of 1000 W. It has an air flow of 400 m³/h and a dehumidifying volume of 1.0 L/h. The unit has a compact design and is easy to install. The Swing Motor’s MP is 28 VA with a three amp fuse for the PCB and a 0.2 amp fuse for the transformer. It uses an aluminum fin evaporator with a copper tube and has a row-fin distance of 2-1.5 mm. It uses a hermetic motor compressor with a working temperature of less than 43º C and an aluminum fin condenser with a copper tube with a row-fin distance of 1-1.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI